An Update of the Ground Testing of the Li-ion Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration (>9 months), both Rovers are equipped with rechargeable Lithium-ion batteries, which have enabled operation for over 854 and 834 Sols of operation, respectively, to date. Given that the batteries were required to support the mission for 90 Sols of operation by design, it is significant that the batteries have demonstrated over a nine fold increase in life over mission objectives. In addition to supporting the surface operations in conjunction with a triple-junction deployable solar arrays, the batteries were designed to aid in the launch and the EDL pyros, and allow for anomalies during cruise. In summary, the requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20 C to +30 C), withstand long storage periods (e.g., cruise period), operate in an inverted orientation, and support high current pulses (e.g., firing pyro events). In order to determine the viability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit (RBAU), consisting of two 8-cell 10 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The testing includes, (a) performing initial characterization tests (discharge capacity at different temperatures), (b) simulating the launch conditions, (c) simulating the cruise phase conditions (including trajectory correction maneuvers), (d) simulating the entry, decent, and landing (EDL) pulse load profile (required to support the pyros) (e) simulating the Mars surface operation mission simulation conditions, as well as, (f) assessing capacity loss and impedance characteristics as a function of temperature and life. This paper provides further detail to previously reported results1 of the RBAU testing program, especially with regard to the life characteristics. To date, the lithium-ion batteries (fabricated by Lithion/Yardney, Inc.) have been demonstrated to far exceed the requirements defined by the mission, both on Mars and on the ground, and are projected to support an extended mission (> 4 years).

Mars Exploration Rovers (MER) Mission↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY↗

Generating AC With Rotating Solar Cells

Rotating solar photovoltaic cells or batteries connected to suitable mechanical and/or electronic commutators produce nearly sinusoidal alternating current. Eliminates need for inverter circuitry and its attendant power-consumption and heat-dissipation problems, but imposes need for low-power-consumption rotary mechanism. Intended for use aboard spacecraft, also useful in special terrestrial situations where solar electric power must be transmitted over powerlines from one remote location to another.

Flanagan, David T.↗

IBR Digital Supply Chain Gap Analysis and Recommendations

The adoption of clean energy technologies, including solar photovoltaics, continues to introduce non-traditional stakeholders to the operations and planning of the electric system. Stakeholders such as manufacturers, vendors, owners, aggregators, and others are enabling the adoption, integration, and optimum operations of solar technologies at accelerated rates. Inverters form the foundation of many digitally controlled energy sources for clean energy technologies, including Solar, Battery Energy Storage Systems, Hybrid Systems, and Hydrogen Fuel Cells. Their supply chain is complex, a series of microchips, electronic switches and other components making up its primary functions. The complexity of this space and the growing digitization associated with these components can create supply chain cyber risks. One measure to mitigate cybersecurity attacks is proper digital supply chain security. The U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), in partnership with the Cybersecurity, Energy, Security, and Emergency Response (CESER) office, is hosting a workshop to bring together solar vendors and services providers to discuss digital supply chain security for solar systems and challenges and opportunities in the transitioning to a fully domestic supply chain for solar energy in the U.S. This workshop will support the Securing Solar for the Grid (S2G) and Energy Cyber Sense program activities. During the workshop, industry experts and researchers from DOE National Laboratories will discuss the current solar supply chain landscape and the transition to domestic manufacturing of solar components in the U.S. Tools and techniques to better manage and secure the digital supply chain of solar devices and systems will be discussed.

cybersecurity↗

Ground testing of the Li-ion batteries in support of JPL's 2003 Mars Exploration Rover Mission

In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(deg)C to +4O(deg)C), withstand long storage periods (e.g., cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the viability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit (RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The testing performed includes, (a) performing initial characterization tests (discharge capacity at different temperatures), (b) simulating the launch conditions, (c) simulating the cruise phase conditions (including trajectory corrections), (d) simulating the entry, decent, and landing pulse load profile (if required to support the pyros) (e) simulating the Mars surface operation mission simulation conditions, as well as, (f) assessing performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by LithiodYardney, Inc.) were demonstrated to far exceed the requirements defined by the mission, and are projected to support an extended mission (> 2 years) with margin to spare.

Li-ion batteries↗

Real-time evaluation of cybersecurity threats to DER inverter grid-support functions

In this project we aim to contribute to the understanding of the type and severity of potential cybersecurity attacks to the grid-support functionalities of DER systems interconnected to the AC distribution grid via inverters. Our preliminary work focused on developing a small-scale testbed allowing to study cybersecurity threats to an isolated photovoltaic-battery system using a real-time simulator (Typhoon HIL602+) with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) system. In this project we propose to expand upon this development by utilizing a) a recently acquired NovaCor RTDS (Real Rime digital Simulator) to emulate the DER-inverter-grid topology including main grid-support functions as defined by IEEE Std. 1547-2018, and b) an industrial control and automation device to enable realistic evaluation of control functions and utilization of communication protocols for real-time data transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Testing of Lithium Li-ion Cells and Batteries in Support of JPL's 2003 Mars Exploration Rover Mission

In early 2004, JPL successfully landed two Rovers, named Spirit and Opportunity, on the surface of Mars after traveling > 300 million miles over a 6-7 month period. In order to operate for extended duration on the surface of Mars, both Rovers are equipped with rechargeable Lithium-ion batteries, which were designed to aid in the launch, correct anomalies during cruise, and support surface operations in conjunction with a triple-junction deployable solar arrays. The requirements of the Lithium-ion battery include the ability to provide power at least 90 sols on the surface of Mars, operate over a wide temperature range (-20(super 0)C to +40(super 0)C), withstand long storage periods (e.g., including pre-launch and cruise period), operate in an inverted position, and support high currents (e.g., firing pyro events). In order to determine the inability of meeting these requirements, ground testing was performed on a Rover Battery Assembly Unit RBAU), consisting of two 8-cell 8 Ah lithium-ion batteries connected in parallel. The RBAU upon which the performance testing was performed is nearly identical to the batteries incorporated into the two Rovers currently on Mars. The primary focus of this paper is to communicate the latest results regarding Mars surface operation mission simulation testing, as well as, the corresponding performance capacity loss and impedance characteristics as a function of temperature and life. As will be discussed, the lithium-ion batteries (fabricated by Yardney Technical Products, Inc.) have been demonstrated to far exceed the requirements defined by the mission, being able to support the operation of the rovers for over three years, and are projected to support an even further extended mission.

low temperature electrolytes↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Integrating System to Edge-of-Network Architecture and Management for SHINES (SEAMS) Technologies of High Penetration Grids

Consistent with the U.S. DOE’s EERE SHINES FOA objectives, the goal of this project was to enable integration from EMS to variable DER in a way that delivered visibility and opportunities for managing and controlling distributed resources using SEAMS technologies. This project implemented several SHINES technologies, which included: (1) three Stem battery systems; (2) six ConnectDER PV collars; (3) two E-Gear PV/Battery storage interfaces; and (4) eight Kitu smart inverter emulators. A Siemens Energy IP DEMS was deployed in a development environment and integrated with the SHINES technologies via OpenADR and IEEE 2030.5 protocols with documented architecture. In the case of IEEE 2030.5, a suite of technologies including a gateway, an API, software and a server from Kitu Systems (the Citadel, Convoy, Kitu Crosslink API, and Kitu Spark) were used to demonstrate that the utility could achieve visibility of distributed energy resources (DER) and control of single and multiple DER systems with a single command. The project also included a LCOE analysis of SHINES technologies compared to traditional system and circuit mitigation measures.

14 SOLAR ENERGY↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗