Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Determine Optimal Stimulus Amplitude for Using Vestibular Stochastic Stimulation to Improve Balance Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface [1]. This technique to improve detection of vestibular signals uses a stimulus delivery system that provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for sensorimotor adaptability (SA) training applications customized to each crewmember. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds [2]. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s long sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower. In the balance task, subjects stood on an unstable surface and had to maintain balance, and the stimulation was administered from 20-400% of subjects' vestibular threshold. Optimal stimulation amplitude was determined at which the balance performance was best compared to control (no stimulation). Preliminary results show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold significantly improved the balance performance. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination may help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

Goel, R.↗

GMI Instrument Spin Balance Method, Optimization, Calibration and Test

The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3-year mission life. Therefore, GMI must be very precisely balanced about the spin axis and center of gravity (CG) to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

Ayari, Laoucet↗

Compact Sensitive Piezoelectric Mass Balance for Measurement of Unconsolidated Materials in Space

In many in-situ instruments information about the mass of the sample could aid in the interpretation of the data and portioning instruments might require an accurate sizing of the sample mass before dispensing the sample. In addition, on potential sample return missions a method to directly assess the captured sample size would be required to determine if the sampler could return or needs to continue attempting to acquire sample. In an effort to meet these requirements piezoelectric balances were developed using flextensional actuators which are capable of monitoring the mass using two methods. A piezoelectric balance could be used to measure mass directly by monitoring the voltage developed across the piezoelectric which is linear with force, or it could be used in resonance to produce a frequency change proportional to the mass change. In this case of the latter, the piezoelectric actuator/balance would be swept in frequency through its fundamental resonance. If a mass is added to the balance the resonance frequency would shift down proportionally to the mass. By monitoring the frequency shift the mass could be determined. This design would allow for two independent measurements of the mass. In microgravity environments spacecraft thrusters could be used to provide acceleration in order to produce the required force for the first technique or to bring the mass into contact with the balance in the second approach. In addition, the measuring actuators, if driven at higher voltages, could be used to fluidize the powder to aid sample movement. In this paper, we outline some of our design considerations and present the results of a few prototype balances that we have developed.

resonance↗

Hybrid Glacier Inventory, Gravimetry and Altimetry (HIGA) Mass Balance Product for Greenland and the Canadian Arctic

We present a novel inversion algorithm that generates a mass balance field that is simultaneously consistent with independent observations of glacier inventory derived from optical imagery, cryosphere-attributed mass trends derived from satellite gravimetry, and ice surface elevation trends derived from airborne and satellite altimetry. We use this algorithm to assess mass balance across Greenland and the Canadian Arctic over the Sep-2003 to Oct- 2009 period at 26 kilometers resolution. We evaluate local algorithm-inferred mass balance against forty in situ point observations. This evaluation yields a root mean squared error (RMSE) of 0.15 mWE/a ( 0.15 meters (water equivalent) per annum), and highlights a paucity of in situ observations from regions of high dynamic mass loss and peripheral glaciers. We assess mass losses of 212 plus or minus 67 Gigatons per annum to the Greenland ice sheet proper, 38 Gigatons per annum to peripheral glaciers in Greenland, and 42 Gigatons per annum to glaciers in the Canadian Arctic. These magnitudes of mass loss are dependent on the gravimetry-derived spherical harmonic mass trend we invert. We spatially partition the transient glacier continuity equation by differencing algorithm inferred mass balance from modeled surface mass balance, in order to solve the horizontal divergence of ice flux as a residual. This residual ice dynamic field infers flux divergence (or submergent flow) in the ice sheet accumulation area and at tidewater margins, and flux convergence (or emergent flow) in land-terminating ablation areas, which is consistent with continuum mechanics theory.

Altimetry↗

Spacecraft Charging Current Balance Model Applied to High Voltage Solar Array Operations

Spacecraft charging induced by high voltage solar arrays can result in power losses and degradation of spacecraft surfaces. In some cases, it can even present safety issues for astronauts performing extravehicular activities. An understanding of the dominant processes contributing to spacecraft charging induced by solar arrays is important to current space missions, such as the International Space Station, and to any future space missions that may employ high voltage solar arrays. A common method of analyzing the factors contributing to spacecraft charging is the current balance model. Current balance models are based on the simple idea that the spacecraft will float to a potential such that the current collecting to the surfaces equals the current lost from the surfaces. However, when solar arrays are involved, these currents are dependent on so many factors that the equation becomes quite complicated. In order for a current balance model to be applied to solar array operations, it must incorporate the time dependent nature of the charging of dielectric surfaces in the vicinity of conductors1-3. This poster will present the factors which must be considered when developing a current balance model for high voltage solar array operations and will compare results of a current balance model with data from the Floating Potential Measurement Unit4 on board the International Space Station.

Willis, Emily M.↗

Assessment of Temperature-Dependent Regression Model Terms of a RUAG Six-Component Block-Type Balance

A metric called the percent contribution was applied to regression models of temperature-dependent calibration data of a RUAG six-component block-type balance in order to assess the influence of temperature-dependent regression model terms on the balance load prediction. Regression models were examined that are needed if either the Iterative or the Non-Iterative Method is used for the load prediction. Computed values of the percent contribution confirmed that the cross-product term defined by a primary load and the temperature difference is the most influential temperature-dependent term of the regression model of a primary output that the Iterative Method needs. Similarly, the analysis showed that the cross-product term defined by a primary output and the temperature difference is the most influential temperature-dependent term of the regression model of a primary load that the Non-Iterative Method needs. Computed results support conclusions that were reported in an earlier theoretical study. This study asserted that the cross-product term defined by a primary load or output and the temperature difference models the temperature-dependent shift of the gage sensitivity. The influence of other temperature-dependent terms used in the regression models of the calibration data of RUAG's balance was negligible. This observation may be explained by the fact that RUAG's block-type balances have highly linear characteristics. Overall, the percent contribution has proven itself to be a reliable and easy-to-implement metric that may also be used for the assessment of the influence of temperature-dependent regression model terms on the load prediction of a six-component strain-gage balance.

Ulbrich, N.↗

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗

Evaluation of Regional Water and Energy Balance in Contemporary Reanalyses

Regional to continental water and energy balance in reanalyses provide crucial information on the climate and climate variations in that region and can contrast other regions. Reanalyses are a valuable tool in piecing together the complete balance owing to the incorporation of the budgets in the background model and the assimilation of observation. On the other hand, the background model has its own biases and observational assimilation can lead to non-negligible tendencies within the budgets, and these can vary over space and time. Here, we will compare the balance within several reanalyses and how they have evolved over recent decades. Several observational data products will provide reference points in the comparison. In addition, a recent project has integrated observations of the water and energy budgets in an optimization that aims to reduce the imbalance of regional budgets in using observational terms from disparate sources. In evaluating the regional balances, we will incorporate, when available, the water and energy convergence terms as well as their analysis increments (which may be diagnosed as residuals). The reanalyses considered here include: Japanese Reanalyses for Three Quarters Century (JRA3Q), ECMWF Reanalysis version 5 (ERA5), Modern Era Retrospective-analysis for Research and Applications version 2 (MERRA-2) and the NCEP Reanalysis II (NCEPR2). NCEPR2 is representative of the late 90s technology, while the others represent the contemporary climate reanalyses presently available. We will discuss the regional balances over key river basins (e.g. Mississippi and Amazon), and a range of continents including those well observed (North America and Europe) and those with fewer consistent observations (e.g. Africa). These contrasting regions show the degree of advancement in reanalyses and expose areas in need of improvement. The results also demonstrate the usefulness of producing complete atmospheric water and energy budgets as part of the diagnostic output.

Michael G Bosilovich↗

Evaluation of Regional Water and Energy Balance in Contemporary Reanalyses

Regional to continental water and energy balance in reanalyses provide crucial information on the climate and climate variations in that region and can contrast other regions. Reanalyses are a valuable tool in piecing together the complete balance owing to the incorporation of the budgets in the background model and the assimilation of observation. On the other hand, the background model has its own biases and observational assimilation can lead to non-negligible tendencies within the budgets, and these can vary over space and time. Here, we will compare the balance within several reanalyses and how they have evolved over recent decades. Several observational data products will provide reference points in the comparison. In addition, a recent project has integrated observations of the water and energy budgets in an optimization that aims to reduce the imbalance of regional budgets in using observational terms from disparate sources. In evaluating the regional balances, we will incorporate, when available, the water and energy convergence terms as well as their analysis increments (which may be diagnosed as residuals). The reanalyses considered here include: Japanese Reanalyses for Three Quarters Century (JRA3Q), ECMWF Reanalysis version 5 (ERA5), Modern Era Retrospective-analysis for Research and Applications version 2 (MERRA-2) and the NCEP Reanalysis II (NCEPR2). NCEPR2 is representative of the late 90s technology, while the others represent the contemporary climate reanalyses presently available. We will discuss the regional balances over key river basins (e.g. Mississippi and Amazon), and a range of continents including those well observed (North America and Europe) and those with fewer consistent observations (e.g. Africa). These contrasting regions show the degree of advancement in reanalyses and expose areas in need of improvement. The results also demonstrate the usefulness of producing complete atmospheric water and energy budgets as part of the diagnostic output.

Michael Bosilovich↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

New Approach for the Assessment of Interactions of a Strain-Gage Balance

A new approach was developed to assess interactions of a strain-gage balance. The approach compares interactions observed during a calibration of the balance with interactions observed during the application of check loads. The approach assumes that alignment errors of the calibration loads are negligible. In that case, interactions observed during the calibration can be used as a reference for the assessment of interactions of check loads. The new approach first fits interactions of a single-component load of the calibration data using simple regression models. Then, interactions of the check loads are predicted by using the check load values as inputs for the regression models of the interactions. In the next step, absolute values of differences between predicted and observed interactions of the check loads are computed. Afterwards, the largest differences are compared with empirical thresholds to assess how well the interactions of the check load data agree with the interactions of the calibration data. Recently obtained data sets of a six-component force balance are used to illustrate the application of the new approach. It is also demonstrated how knowledge of balance design characteristics can benefit the assessment of interactions.

wind tunnel test↗

Assessment of New Load Schedules for the Machine Calibration of a Force Balance

New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.

wind tunnel testing↗

Pre-Test Assessment of the Use Envelope of the Normal Force of a Wind Tunnel Strain-Gage Balance

The relationship between the aerodynamic lift force generated by a wind tunnel model, the model weight, and the measured normal force of a strain-gage balance is investigated to better understand the expected use envelope of the normal force during a wind tunnel test. First, the fundamental relationship between normal force, model weight, lift curve slope, model reference area, dynamic pressure, and angle of attack is derived. Then, based on this fundamental relationship, the use envelope of a balance is examined for four typical wind tunnel test cases. The first case looks at the use envelope of the normal force during the test of a light wind tunnel model at high subsonic Mach numbers. The second case examines the use envelope of the normal force during the test of a heavy wind tunnel model in an atmospheric low-speed facility. The third case reviews the use envelope of the normal force during the test of a floor-mounted semi-span model. The fourth case discusses the normal force characteristics during the test of a rotated full-span model. The wind tunnel model's lift-to-weight ratio is introduced as a new parameter that may be used for a quick pre-test assessment of the use envelope of the normal force of a balance. The parameter is derived as a function of the lift coefficient, the dimensionless dynamic pressure, and the dimensionless model weight. Lower and upper bounds of the use envelope of a balance are defined using the model's lift-to-weight ratio. Finally, data from a pressurized wind tunnel is used to illustrate both application and interpretation of the model's lift-to-weight ratio.

strain-gage balance↗

Ka-Band GaN-on-SiC MMIC Balanced High Power Amplifier for NASA's Lunar Missions

The feasibility of Ka-band GaN-on-SiC MMIC based balanced power amplifier for science data downlinks from NASA’s lunar mission assets in space is investigated. The balanced amplifier combines the RF output power from two power amplifiers using a rectangular waveguide based 3-dB hybrid coupler. The investigation includes characterizing the balanced amplifier for the overall RF output power, Gain, power added efficiency, RMS error vector magnitude for offset-QPSK, 8PSK, 16APSK, and 32APSK waveforms, 3rd order intermodulation products, and noise figure. The balanced amplifier has high output RF power and good linearity and can support high data rate downlinks from the surface and vicinity of the Moon to Earth.

Gallium Nitride↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low- load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the gage sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low-load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the bridge sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

An efficient algorithm using matrix methods to solve wind tunnel force-balance equations

An iterative procedure applying matrix methods to accomplish an efficient algorithm for automatic computer reduction of wind-tunnel force-balance data has been developed. Balance equations are expressed in a matrix form that is convenient for storing balance sensitivities and interaction coefficient values for online or offline batch data reduction. The convergence of the iterative values to a unique solution of this system of equations is investigated, and it is shown that for balances which satisfy the criteria discussed, this type of solution does occur. Methods for making sensitivity adjustments and initial load effect considerations in wind-tunnel applications are also discussed, and the logic for determining the convergence accuracy limits for the iterative solution is given. This more efficient data reduction program is compared with the technique presently in use at the NASA Langley Research Center, and computational times on the order of one-third or less are demonstrated by use of this new program.

Smith, D. L.↗