Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “background radiation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Beam Path Toxicities to Non-Target Structures During Intensity-Modulated Radiation Therapy for Head and Neck Cancer

Background: Intensity-modulated radiation therapy (IMRT) beams traverse nontarget normal structures not irradiated during three-dimensional conformal RT (3D-CRT) for head and neck cancer (HNC). This study estimates the doses and toxicities to nontarget structures during IMRT. Materials and Methods: Oropharyngeal cancer IMRT and 3D-CRT cases were reviewed. Dose-volume histograms (DVH) were used to evaluate radiation dose to the lip, cochlea, brainstem, occipital scalp, and segments of the mandible. Toxicity rates were compared for 3D-CRT, IMRT alone, or IMRT with concurrent cisplatin. Descriptive statistics and exploratory recursive partitioning analysis were used to estimate dose 'breakpoints' associated with observed toxicities. Results: A total of 160 patients were evaluated for toxicity; 60 had detailed DVH evaluation and 15 had 3D-CRT plan comparison. Comparing IMRT with 3D-CRT, there was significant (p {<=} 0.002) nonparametric differential dose to all clinically significant structures of interest. Thirty percent of IMRT patients had headaches and 40% had occipital scalp alopecia. A total of 76% and 38% of patients treated with IMRT alone had nausea and vomiting, compared with 99% and 68%, respectively, of those with concurrent cisplatin. IMRT had a markedly distinct toxicity profile than 3D-CRT. In recursive partitioning analysis, National Cancer Institute's Common Toxicity Criteria adverse effects 3.0 nausea and vomiting, scalp alopecia and anterior mucositis were associated with reconstructed mean brainstem dose >36 Gy, occipital scalp dose >30 Gy, and anterior mandible dose >34 Gy, respectively. Conclusions: Dose reduction to specified structures during IMRT implies an increased beam path dose to alternate nontarget structures that may result in clinical toxicities that were uncommon with previous, less conformal approaches. These findings have implications for IMRT treatment planning and research, toxicity assessment, and multidisciplinary patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classification of background suppression profiles for low background RPM data

Suppression of the ambient gamma background radiation by traffic structure and cargo is a well-understood and studied effect for deployed radiation portal monitors (RPM). For effective analysis of measured RPM profiles with the objective of inferring the spatial characteristics of radiation sources, it is important to account for the effects of background suppression. In this report we analyze background suppression for a test dataset from vehicle RPMs at a sample port and estimate the distributions of suppression amplitudes and shapes. Cluster analysis of standardized and normalized profiles is used to obtain the dominant suppression shapes in the sample field data. We determine that a large fraction of non-alarm RPM occupancies are represented by a small number of suppression shapes. This fraction increases when the signal-to-noise ratio of an occupancy profile is improved by the addition of signals for multiple RPM detectors located at the same height. The calculated suppression shapes from RPM data can be used along with source models in the process of spatial profile analysis both in the field or offline. This background suppression analysis is an important step in improving the effectiveness of the RPM profile analysis methodology which is currently being investigated and may lead to methods that reduce the number of secondary inspections as well as to decision support tools that aid operators in evaluating RPM data that do not contain spectral information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of composite bolometers at 0.4 Kelvin

Composite bolometer structures have provided the most sensitive IR detectors for operation at helium-4 temperatures of 1.5K. Below 1.5K the electrical and thermal properties change significantly and the performance characteristics cannot be accurately extrapolated for composite bolometers at helium-3 temperatures of 0.4K. The paper deals with experimentally assessed performance of composite bolometers at 0.4K. It is found that sensitivity estimates derived from electrical or load curve properties can overestimate the responsivity to radiation by several orders of magnitude depending upon a particular material behavior. For many near-millimeter applications background power levels are several nanowatts and the associated photon noise plus Johnson and phonon noise components impose a fundamental detection limit of about 5 x 10 to the -15thW/Hz to the -1/2. We have successfully fabricated composite bolometers which at 0.4 K and millimeter wavelengths achieve a noise equivalent power of 7 x 10 to the -15thW/Hz to the -1/2 coupled with a large absorbing area (0.3 sq cm) and a fast response time (2 msec.).

El-Ataway, S.↗

A hydrodynamic approach to cosmology - Methodology

The present study describes an accurate and efficient hydrodynamic code for evolving self-gravitating cosmological systems. The hydrodynamic code is a flux-based mesh code originally designed for engineering hydrodynamical applications. A variety of checks were performed which indicate that the resolution of the code is a few cells, providing accuracy for integral energy quantities in the present simulations of 1-3 percent over the whole runs. Six species (H I, H II, He I, He II, He III) are tracked separately, and relevant ionization and recombination processes, as well as line and continuum heating and cooling, are computed. The background radiation field is simultaneously determined in the range 1 eV to 100 keV, allowing for absorption, emission, and cosmological effects. It is shown how the inevitable numerical inaccuracies can be estimated and to some extent overcome.

Cen, Renyue↗

THE THERMAL PROPERTIES OF SOLAR FLARES OVER THREE SOLAR CYCLES USING GOES X-RAY OBSERVATIONS

Solar flare X-ray emission results from rapidly increasing temperatures and emission measures in flaring active region loops. To date, observations from the X-Ray Sensor (XRS) on board the Geostationary Operational Environmental Satellite (GOES) have been used to derive these properties, but have been limited by a number of factors, including the lack of a consistent background subtraction method capable of being automatically applied to large numbers of flares. In this paper, we describe an automated Temperature and Emission measure-Based Background Subtraction method (TEBBS), that builds on the methods of Bornmann. Our algorithm ensures that the derived temperature is always greater than the instrumental limit and the pre-flare background temperature, and that the temperature and emission measure are increasing during the flare rise phase. Additionally, TEBBS utilizes the improved estimates of GOES temperatures and emission measures from White et al. TEBBS was successfully applied to over 50,000 solar flares occurring over nearly three solar cycles (1980-2007), and used to create an extensive catalog of the solar flare thermal properties. We confirm that the peak emission measure and total radiative losses scale with background subtracted GOES X-ray flux as power laws, while the peak temperature scales logarithmically. As expected, the peak emission measure shows an increasing trend with peak temperature, although the total radiative losses do not. While these results are comparable to previous studies, we find that flares of a given GOES class have lower peak temperatures and higher peak emission measures than previously reported. The TEBBS database of flare thermal plasma properties is publicly available at http://www.SolarMonitor.org/TEBBS/.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of autonomous gamma dose logger for environmental monitoring

Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban Environment

The detection of radioactive sources in an urban setting is greatly complicated by natural background radiation, which emanates from various materials including roadways, sidewalks, soil, and building exteriors. The method presented and demonstrated here represents an effort to characterize the concentration of naturally occurring radioactive material (NORM) in these types of materials. The location surveyed in this work was the Fort Indiantown Gap Combined Arms Collective Training Facility in Lebanon County, Pennsylvania. Over 70 measurements with a high-purity germanium detector were performed to ascertain the NORM concentrations present in the soil, asphalt, gravel, concrete, and walls found throughout the site. Monte Carlo radiation transport calculations were used to obtain detector responses for these various geometries and materials to convert these measurements into NORM concentration estimates. Lastly, synthetic spectra were simulated using the predicted source terms and compared to actual measurements, showing acceptable agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASSESSING THE ROLE OF SPIN NOISE IN THE PRECISION TIMING OF MILLISECOND PULSARS

We investigate rotational spin noise (referred to as timing noise) in non-accreting pulsars: millisecond pulsars, canonical pulsars, and magnetars. Particular attention is placed on quantifying the strength and non-stationarity of timing noise in millisecond pulsars because the long-term stability of these objects is required to detect nanohertz gravitational radiation. We show that a single scaling law is sufficient to characterize timing noise in millisecond and canonical pulsars while the same scaling law underestimates the levels of timing noise in magnetars. The scaling law, along with a detailed study of the millisecond pulsar B1937+21, leads us to conclude that timing noise is latent in most millisecond pulsars and will be measurable in many objects when better arrival time estimates are obtained over long data spans. The sensitivity of a pulsar timing array to gravitational radiation is strongly affected by any timing noise. We conclude that detection of proposed gravitational wave backgrounds will require the analysis of more objects than previously suggested over data spans that depend on the spectra of both the gravitational wave background and of the timing noise. It is imperative to find additional millisecond pulsars in current and future surveys in order to reduce the effects of timing noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Large scale magnetic fields from gravitationally coupled electrodynamics

The generation of primordial magnetic seed fields during inflation is studied in a theory derived from the one-loop vacuum polarization effective action of the photon in a curved background. This includes terms which couple the curvature to the Maxwell tensor. The resulting magnetic field strength is estimated in a model where the inflationary phase is directly matched to the standard radiation dominated era. The allowed parameter region is analyzed and compared with the bounds necessary to seed the galactic magnetic field. It is found that magnetic fields of cosmologically interesting field strengths can be generated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Properties of water vapor relevant to its measurement in the stratosphere and mesosphere

The literature on the concentrations of water vapor in the stratosphere and mesosphere was studied. It is estimated that the concentrations in these lie in the range from 0.1 ppm to 10 ppm. A survey was made of the scattering and radiative transfer properties of water vapor and the background constituents to determine the physical properties of importance to measurements of concentrations. It was determined that absorption and emission properties provide significant increases in sensitivity compared with the various scattering phenomena considered. Microwave absorption in the region of 22 GHz and 183 GHz and infrared absorption in the vibrational rotational band systems seem to be the most attractive techniques. Various experimental configurations are analyzed and compared.

Longbothum, R. L.↗

TU-C-18A-01: Models of Risk From Low-Dose Radiation Exposures: What Does the Evidence Say?

At dose levels of (approximately) 500 mSv or more, increased cancer incidence and mortality have been clearly demonstrated. However, at the low doses of radiation used in medical imaging, the relationship between dose and cancer risk is not well established. As such, assumptions about the shape of the dose-response curve are made. These assumptions, or risk models, are used to estimate potential long term effects. Common models include 1) the linear non-threshold (LNT) model, 2) threshold models with either a linear or curvilinear dose response above the threshold, and 3) a hormetic model, where the risk is initially decreased below background levels before increasing. The choice of model used when making radiation risk or protection calculations and decisions can have significant implications on public policy and health care decisions. However, the ongoing debate about which risk model best describes the dose-response relationship at low doses of radiation makes informed decision making difficult. This symposium will review the two fundamental approaches to determining the risk associated with low doses of ionizing radiation, namely radiation epidemiology and radiation biology. The strengths and limitations of each approach will be reviewed, the results of recent studies presented, and the appropriateness of different risk models for various real world scenarios discussed. Examples of well-designed and poorly-designed studies will be provided to assist medical physicists in 1) critically evaluating publications in the field and 2) communicating accurate information to medical professionals, patients, and members of the general public. Equipped with the best information that radiation epidemiology and radiation biology can currently provide, and an understanding of the limitations of such information, individuals and organizations will be able to make more informed decisions regarding questions such as 1) how much shielding to install at medical facilities, 2) at what dose level are risk vs. benefit discussions with patients appropriate, 3) at what dose level should we tell a pregnant woman that the baby’s health risk from a prenatal radiation exposure is “significant”, 4) is informed consent needed for patients undergoing medical imaging, and 5) at what dose level is evacuation appropriate after a radiological accident. Examples of the tremendous impact that choosing different risks models can have on the answers to these types of questions will be given.A moderated panel discussion will allow audience members to pose questions to the faculty members, each of whom is an established expert in his respective discipline. Learning Objectives: Understand the fundamental principles, strengths and limitations of radiation epidemiology and radiation biology for determining the risk from exposures to low doses of ionizing radiation Become familiar with common models of risk used to describe the dose-response relationship at low dose levels Learn to identify strengths and weaknesses in studies designed to measure the effect of low doses of ionizing radiation Understand the implications of different risk models on public policy and health care decisions.

60 APPLIED LIFE SCIENCES↗

Gravitational wave background from Standard Model physics: qualitative features

Because of physical processes ranging from microscopic particle collisions to macroscopic hydrodynamic fluctuations, any plasma in thermal equilibrium emits gravitational waves. For the largest wavelengths the emission rate is proportional to the shear viscosity of the plasma. In the Standard Model at T>160 GeV, the shear viscosity is dominated by the most weakly interacting particles, right-handed leptons, and is relatively large. We estimate the order of magnitude of the corresponding spectrum of gravitational waves. Even though at small frequencies (corresponding to the sub-Hz range relevant for planned observatories such as eLISA) this background is tiny compared with that from non-equilibrium sources, the total energy carried by the high-frequency part of the spectrum is non-negligible if the production continues for a long time. We suggest that this may constrain (weakly) the highest temperature of the radiation epoch. Observing the high-frequency part directly sets a very ambitious goal for future generations of GHz-range detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of accretion on primordial black holes in Brans-Dicke theory

We consider the effect of accretion of radiation in the early Universe on primordial black holes in Brans-Dicke theory. The rate of growth of a primordial black hole due to accretion of radiation in Brans-Dicke theory is considerably smaller than the rate of growth of the cosmological horizon, thus making available sufficient radiation density for the black hole to accrete causally. We show that accretion of radiation by Brans-Dicke black holes overrides the effect of Hawking evaporation during the radiation dominated era. The subsequent evaporation of the black holes in later eras is further modified due to the variable gravitational 'constant', and they could survive up to longer times compared to the case of standard cosmology. We estimate the impact of accretion on modification of the constraint on their initial mass fraction obtained from the {gamma}-ray background limit from presently evaporating primordial black holes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-energy radiative backgrounds in CCD-based dark-matter detectors

The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles as they pass through detector materials and perform a detailed simulation to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected at Fermilab near the MINOS cavern. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination radiation; photo-absorption in the bulk, backside layer, pitch adapter, and epoxy; the photon reflection and refraction at interfaces; thin-film interference; the roughness of the interfaces; the dynamics of charges produced in the highly doped CCD-backside-layers; and the partial charge collection on the CCD backside. We consider several systematic uncertainties, notably those stemming from the backside modeling, which we estimate with a “fiducial” and an “extreme” charge-diffusion model, with the former model being preferred due to better agreement with partial-charge collection data. We find that Cherenkov photons constitute about 30% of the observed single-electron events for both diffusion models; radiative recombination contributes negligibly to the event rate for the fiducial model, although it can dominate over Cherenkov for the extreme model. We also estimate the fraction of 2-electron events that arise from 1-electron event coincidences in the same pixel, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for both radiative and non-radiative backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNP Estimate of ZLS Lens Sensitivity in an X-Ray Field

The telecentric zoom lens system (ZLS) has proven to be invaluable in flash x-ray field operations and recent successful experiments pertaining to stockpile stewardship. The ZLS contains 11 custom-manufactured lenses, a turning mirror (pellicle), and an x-ray-to-visible-light converting scintillator. Images are recorded on a fully characterized CCD. All hardware is supported by computerized, programmable, electro-mechanical mounts and alignment apparatus. Seven different glass material types varying in chemical stoichiometry comprise the 11 ZLS lenses. All lenses within the ZLS are out of the path of direct x-ray radiation during normal operation. However, any unshielded scattered x-ray radiation can result in energy deposition into the lenses, which may generate some scintillating light that can couple into the CCD. This extra light may contribute to a decrease in signal-to-noise ratio (SNR) and lower the overall fidelity of the radiograph images. An estimate of the scintillation generation and sensitivities for each of the seven types of glass used as lenses in the ZLS is presented. This report also includes estimates of the total observed background decoupling that each of the lens material types contribute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 21-cm Signal from the cosmological epoch of recombination

The redshifted 21-cm emission by neutral hydrogen offers a unique tool for mapping structure formation in the early universe in three dimensions. Here we provide the first detailed calculation of the 21-cm emission signal during and after the epoch of hydrogen recombination in the redshift range of z ∼ 500–1,100, corresponding to observed wavelengths of 100–230 meters. The 21-cm line deviates from thermal equilibrium with the cosmic microwave background (CMB) due to the excess Lyα radiation from hydrogen and helium recombinations. The resulting 21-cm signal reaches a brightness temperature of a milli-Kelvin, orders of magnitude larger than previously estimated. Its detection by a future lunar or space-based observatory could improve dramatically the statistical constraints on the cosmological initial conditions compared to existing two-dimensional maps of the CMB anisotropies.

79 ASTRONOMY AND ASTROPHYSICS↗

Microwave background fluctuations due to the Sunyaev-Zel'dovich effects in pancakes

We calculate distortions in the microwave background radiation from the Sunyaev-Zel'dovich effect, produced by hot gas in large (approximately 100 Mpc) pancakes. The large-scale distribution of the pancakes is taken to be that of a Voronoi foam. Fluctuations for this scenario are estimated to be on the order of delta T/T is approximately 10(exp -5). Using computer simulations, we produce several 32 deg x 32 deg images with 0.25 deg resolution. These images show characteristic linear features produced when a pancake is viewed nearly edge-on. By calculating the two-point and the degenerate three-point correlation functions, we are able to statistically detect such non-Gaussian features even in the presence of a relatively large amount of Gaussian noise. The degenerate three-point correlation function is found to be particularly useful since it is insensitive to correlated Gaussian noise. We also smooth our data over a 7 deg Full Width at Half Maximum (FWHM) Gaussian window to simulate the Cosmic Background Explorer Satellite (COBE) observations. We find that under such low-resolution conditions, the features are highly suppressed.

Subbarao, M. U.↗