Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An experimental investigation of a low Reynolds number turbulent boundary layer subject to an adverse pressure gradient

A very low Reynolds number turbulent boundary layer subject to an adverse pressure gradient is studied. The aim is to obtain highly accurate mean-flow and turbulence measurements under conditions that can be closely related to the numerical simulations of Philippe Spalart for the purposes of CFD validation. Much of the Boundary Layer Wind Tunnel was completely rebuilt with a new wider contraction and working section which will improve compatibility with the simulations. A unique sophisticated high-speed computer controlled 3-D probe traversing mechanism was integrated into the test section. Construction of the tunnel and traverse is discussed in some detail. The hardware is now complete, and measurements are in progress. The mean-flow data indicate that a suitably two-dimensional base flow was established. Automation of the probe positioning and data acquistion have led to a decreased running time for total pressure measurements. However, the most significant benefits are expected to occur when using hot-wire probes. Calibrations can be performed automatically and there is no need to handle fragile probes when moving between measuring stations. Techniques are being developed which require sampling of the signals from moving hot-wire probes on the basis of their position in the flow. Measurements can be made in high intensity turbulence by flying probes upstream at high speed so that the relative magnitude of the turbulent velocity fluctuations are reduced. In regions, where the turbulence intensity is not too large, the probe can also be repetitively scanned across very dense spatial grids in other directions. With this technique, a complete profile can be measured in about 1/3 the time and with a spatial density about 50 times that obtainable using a stationary probe.

Watmuff, Jonathan H.↗

A real time dynamic data acquisition and processing system for velocity, density, and total temperature fluctuation measurements

The real time Dynamic Data Acquisition and Processing System (DDAPS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAPS replaces both a recording mechanism and a separate data processing system. DDAPS receives input from hot wire anemometers. Amplifiers and filters condition the signals with computer controlled modules. The analog signals are simultaneously digitized and digitally recorded on disk. Automatic acquisition collects necessary calibration and environment data. Hot wire sensitivities are generated and applied to the hot wire data to compute fluctuations. The presentation of the raw and processed data is accomplished on demand. The interface to DDAPS is described along with the internal mechanisms of DDAPS. A summary of operations relevant to the use of the DDAPS is also provided.

Clukey, Steven J.↗

An Automated Method for Ozonesonde Calibration: New Insights

An automated method for preparation of the electrochemical concentration cell (ECC) ozonesonde is presented. Development of a computer-controlled system for preparation and calibration of the ECC is an improvement over the manual preparation method, and reduces subjectivity considerably. Preparation measurements in digital form aids analysis of the ECC before release and enhances post-flight data certification. Calibration of ozonesondes over a range of ozone concentrations between 0 mPA and 30 mPA is discussed. This presentation describes the automatic system, gives examples of calibrations. The automated system enables comparison of varying potassium iodide (KI) concentrations that should allow adjustment of earlier ozonesonde data obtained with different KT concentrations used since 1970, i.e., 2, 1.5, 1, and 0.5 percent. Preliminary results indicate ECC accuracy has a strong dependence on the electrolyte concentration and should not be considered linear with altitude.

Schmidlin, F. J.↗

Space environment robot vision system

A prototype twin-camera stereo vision system for autonomous robots has been developed at Goddard Space Flight Center. Standard charge coupled device (CCD) imagers are interfaced with commercial frame buffers and direct memory access to a computer. The overlapping portions of the images are analyzed using photogrammetric techniques to obtain information about the position and orientation of objects in the scene. The camera head consists of two 510 x 492 x 8-bit CCD cameras mounted on individually adjustable mounts. The 16 mm efl lenses are designed for minimum geometric distortion. The cameras can be rotated in the pitch, roll, and yaw (pan angle) directions with respect to their optical axes. Calibration routines have been developed which automatically determine the lens focal lengths and pan angle between the two cameras. The calibration utilizes observations of a calibration structure with known geometry. Test results show the precision attainable is plus or minus 0.8 mm in range at 2 m distance using a camera separation of 171 mm. To demonstrate a task needed on Space Station Freedom, a target structure with a movable I beam was built. The camera head can autonomously direct actuators to dock the I-beam to another one so that they could be bolted together.

Wood, H. John↗

A Dirichlet process mixture model for automatic {sup 18}F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions

Purpose: The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. Methods: The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10–37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Results: Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This “calibration curve” was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. Conclusions: The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.

60 APPLIED LIFE SCIENCES↗

OpenStudio: A Platform for Ex Ante Incentive Programs

Many utilities operate programs that provide ex ante (up front) incentives for building energy conservation measures (ECMs). A typical incentive program covers two kinds of ECMs. ECMs that deliver similar savings in different contexts are associated with pre-calculated 'deemed' savings values. ECMs that deliver different savings in different contexts are evaluated on a 'custom' per-project basis. Incentive programs often operate at less than peak efficiency because both deemed ECMs and custom projects have lengthy and effort-intensive review processes--deemed ECMs to gain confidence that they are sufficiently context insensitive, custom projects to ensure that savings are claimed appropriately. DOE's OpenStudio platform can be used to automate ex ante processes and help utilities operate programs more efficiently, consistently, and transparently, resulting in greater project throughput and energy savings. A key concept of the platform is the OpenStudio Measure, a script that queries and transforms building energy models. Measures can be simple or surgical, e.g., applying different transformations based on space-type, orientation, etc. Measures represent ECMs explicitly and are easier to review than ECMs that are represented implicitly as the difference between a with-ECM and without-ECM models. Measures can be automatically applied to large numbers of prototype models--and instantiated from uncertainty distributions--facilitating the large scale analysis required to develop deemed savings values. For custom projects, Measures can also be used to calibrate existing building models, to automatically create code baseline models, and to perform quality assurance screening.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Constitutive Models via Automatic Differentiation v.1.0.0

SAND2024-00905O Constitutive Models via Automatic Differentiation (CMAD) provides a software framework for solving constitutive or material model calibration problems. It relies on JAX's automatic differentiation capabilities to compute the derivatives needed for both forward and adjoint sensitivity analyses. The software can be used to implement constitutive models and calibrate the parameters from experimental data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Seidl, Daniel↗

Development of an in situ calibration technique for combustible gas detectors

This paper describes the development of an in situ calibration procedure for combustible gas detectors (CGD). The CGD will be a necessary device for future space vehicles as many subsystems in the Environmental Control/Life Support System utilize or produce hydrogen (H2) gas. Existing calibration techniques are time-consuming and require support equipment such as an environmental chamber and calibration gas supply. The in situ calibration procedure involves utilization of a water vapor electrolysis cell for the automatic in situ generation of a H2/air calibration mixture within the flame arrestor of the CGD. The development effort concluded with the successful demonstration of in situ span calibrations of a CGD.

Shumar, J. W.↗

Automated Radioanalytical System Incorporating Microwave-Assisted Sample Preparation, Chemical Separation, and Online Radiometric Detection for the Monitoring of Total 99Tc in Nuclear Waste Processing Streams

An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-262: Commissioning Varian Portal Dosimetry for EPID-Based Patient Specific QA in a Non-Aria Environment

Purpose: Development of an in-house program facilitates a workflow that allows Electronic Portal Imaging Device (EPID) patient specific quality assurance (QA) measurements to be acquired and analyzed in the Portal Dosimetry Application (Varian Medical Systems, Palo Alto, CA) using a non-Aria Record and Verify (R&V) system (MOSAIQ, Elekta, Crawley, UK) to deliver beams in standard clinical treatment mode. Methods: Initial calibration of an in-house software tool includes characterization of EPID dosimetry parameters by importing DICOM images of varying delivered MUs to determine linear mapping factors in order to convert image pixel values to Varian-defined Calibrated Units (CU). Using this information, the Portal Dose Image Prediction (PDIP) algorithm was commissioned by converting images of various field sizes to output factors using the Eclipse Scripting Application Programming Interface (ESAPI) and converting a delivered configuration fluence to absolute dose units. To verify the algorithm configuration, an integrated image was acquired, exported directly from the R&V client, automatically converted to a compatible, calibrated dosimetric image, and compared to a PDIP calculated image using Varian’s Portal Dosimetry Application. Results: For two C-Series and one TrueBeam Varian linear accelerators, gamma comparisons (global 3% / 3mm) of PDIP algorithm predicted dosimetric images and images converted via the inhouse system demonstrated agreement for ≥99% of all pixels, exceeding vendor-recommended commissioning guidelines. Conclusion: Combinations of a programmatic image conversion tool and ESAPI allow for an efficient and accurate method of patient IMRT QA incorporating a 3rd party R&V system.

60 APPLIED LIFE SCIENCES↗

A direct-adjoint approach for material point model calibration with application to plasticity

Here, this paper proposes a new approach for the calibration of material parameters in local elastoplastic constitutive models. The calibration is posed as a constrained optimization problem, where the constitutive model evolution equations for a single material point serve as constraints. The objective function quantifies the mismatch between the stress predicted by the model and corresponding experimental measurements. To improve calibration efficiency, a novel direct-adjoint approach is presented to compute the Hessian of the objective function, which enables the use of second-order optimization algorithms. Automatic differentiation is used for gradient and Hessian computations. Two numerical examples are employed to validate the Hessian matrices and to demonstrate that the Newton–Raphson algorithm consistently outperforms gradient-based algorithms such as L-BFGS-B.

36 MATERIALS SCIENCE↗

Automated geologic mapping using rock reflectances.

Investigation of the feasibility of preparing geologic maps automatically through computer processing of calibrated narrow-band visible and near IR reflectivity data collected with a 12-channel scanner. Five procedures were followed in the computer analysis of the radiances recorded as voltages on analog magnetic tape. Three recognition maps have been generated iteratively using a progressively more complex classification scheme. The overall accuracy of the first recognition map was 80%, but the discrimination of the limestone and dolomite was only 50-60%. All three maps are very accurate outcrop maps. The results demonstrate the feasibility of automated geologic mapping in this relatively simple setting.

Watson, R. D.↗

A distributed processing high data rate multiport wind-tunnel pressure measurement system

A multiport pressure measurement system has been developed for the high data rates and the in situ calibration of electronically scanned pressure (ESP) sensors. The system employs a stand-alone microcomputer, connected to a host computer, for data acquisition and preprocessing. The host computer provides several operational modes. Before each run the in situ calibration of each sensor is automatically performed. Using up to a maximum of 14 data acquisition and control units (DACU's), the system may be expanded from 16 to 10,752 pressure ports. Each DACU can make 20,000 measurements per second, average data, and perform statistical analyses before transferring data to the central unit. The system may be introduced into existing facilities and requires little user orientation.

Juanarena, D.↗

Triple redundant hydrogen sensor with in situ calibration

To meet sensing and calibration needs, an in situ calibration technique was developed. It is based on electrolytic generation of a hydrogen/air atmosphere within a hydrogen sensor. The hydrogen is generated from water vapor in the air, and being electrical in nature, the in situ calibration can be performed completely automatically in remote locations. Triply redundant sensor elements are integrated within a single, compact housing, and digital logic provides inter-sensor comparisons to warn of and identify malfunctioning sensor elements. An evaluation of this concept is presented.

Lantz, J. B.↗

Study of the structure of turbulent shear flows at supersonic speeds and high Reynolds number

A major effort to improve the accuracies of turbulence measurement techniques is described including the development and testing of constant temperature hot-wire anemometers which automatically compensate for frequency responses. Calibration and data acquisition techniques for normal and inclined wires operated in the constant temperature mode, flow geometries, and physical models to explain the observed behavior of flows are discussed, as well as cooperation with computational groups in the calculation of compression corner flows.

Smits, A. J.↗

Simultaneous and Constrained Calibration of Multiple Hyperspectral Images Through a New Generalized Empirical Line Model

The empirical line (EL) calibration method is commonly used for atmospheric correction of remotely sensed spectral images and recovery of surface reflectance. The current EL-based methods are applicable to calibrate only single images. Therefore, the use of the EL calibration is impractical for imaging campaigns, where many (partially overlapped) images are acquired to cover a large area. In addition, the EL results are unconstrained and an undesired reflectance with negative values or larger than 100% can be obtained. In this paper, we use the standard EL model to formulate a new generalized empirical line (GEL) model. Based on the GEL, we present a novel method for simultaneous and constrained calibration of multiple images. This new method allows for calibration through multiple image constrained empirical line (MIcEL) and three additional calibration modes. Given a set of images, we use the available ground targets and automatically extracted tie points between overlapping images to calibrate all the images in the set simultaneously. Quantitative and visual assessments of the proposed method were carried out relatively to the off-the-shelf method quick atmospheric correction (QUAC), using real hyperspectral images and field measurements. The results clearly show the superiority of MIcEL with respect to the minimization of the difference between the reflectance values of the same object in different overlapping images. An assessment of the absolute accuracy, with respect to 11 field measurement points, shows that the accuracy of MIcEL, with an average mean absolute error (MAE) of ~11%, is comparable with respect to the QUAC.

47 OTHER INSTRUMENTATION↗