Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Spectral-Modulation Characteristics of Vertical-Cavity Surface-Emitting Lasers

The requirements imposed on vertical-cavity surface-emitting lasers in a number of metrological problems in which optical pumping of alkali atoms is used are considered. For lasers produced by different manufacturers, these requirements are compared with the experimentally observed spectral characteristics at a constant pump current and in the microwave modulation mode. It is shown that a comparatively small number of lasers in the microwave modulation mode make it possible to obtain the spectrum required for atomic clocks based on the coherent population-trapping effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gravitizing the quantum

We discuss a new approach to the problem of quantum gravity in which the quantum mechanical structures that are traditionally fixed, such as the Fubini–Study metric in the Hilbert space of states, become dynamical and so implement the idea of gravitizing the quantum. In particular, in this formulation of quantum gravity the quantum geometry is still consistent with the principles of unitarity and also captures fundamental aspects of (quantum) gravity, such as topology change. As a result, we address specific ways of testing this new approach to quantum gravity by utilizing multipath interference and optical lattice atomic clocks.

Quantum gravity↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

Constraining the Evolution of ZZ Ceti

We report our analysis of the stability of pulsation periods in the DAV star (pulsating hydrogen atmosphere white dwarf) ZZ Ceti, also called R548. On the basis of observations that span 31 years, we conclude that the period 213.13 s observed in ZZ Ceti drifts at a rate dP/dt 5 (5.5 plus or minus 1.9) x 10(exp -15) ss(sup -1), after correcting for proper motion. Our results are consistent with previous P values for this mode and an improvement over them because of the larger time base. The characteristic stability timescale implied for the pulsation period is |P||P(raised dot)|greater than or equal to 1.2 Gyr, comparable to the theoretical cooling timescale for the star. Our current stability limit for the period 213.13 s is only slightly less than the present measurement for another DAV, G117-B15A, for the period 215.2 s, establishing this mode in ZZ Ceti as the second most stable optical clock known, comparable to atomic clocks and more stable than most pulsars. Constraining the cooling rate of ZZ Ceti aids theoretical evolutionary models and white dwarf cosmochronology. The drift rate of this clock is small enough that we can set interesting limits on reflex motion due to planetary companions.

Mukadam, Anjum S.↗

Long-lived Bell states in an array of optical clock qubits

The generation of long-lived entanglement in optical atomic clocks is one of the main goals of quantum metrology. Arrays of neutral atoms, where Rydberg-based interactions may generate entanglement between individually controlled and resolved atoms, constitute a promising quantum platform to achieve this. Here we leverage the programmable state preparation afforded by optical tweezers and the efficient strong confinement of a three-dimensional optical lattice to prepare an ensemble of strontium-atom pairs in their motional ground state. We engineer global single-qubit gates on the optical clock transition and two-qubit entangling gates via adiabatic Rydberg dressing, enabling the generation of Bell states with a state-preparation-and-measurement-corrected fidelity of 92.8(2.0)% (87.1(1.6)% without state-preparation-and-measurement correction). For use in quantum metrology, it is furthermore critical that the resulting entanglement be long lived; we find that the coherence of the Bell state has a lifetime of 4.2(6) s via parity correlations and simultaneous comparisons between entangled and unentangled ensembles. Such long-lived Bell states can be useful for enhancing metrological stability and bandwidth. In the future, atomic rearrangement will enable the implementation of many-qubit gates and cluster state generation, as well as explorations of the transverse field Ising model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clock Synchronization

Experimental goals are: (1) synchronize 1 pulse per second outputs derived from two different crystal oscillator sources, (2) generate near atomic clock accuracy for other experimental needs.

atomic clock↗

Millisecond pulsar observation system at CRL

Millisecond pulsars have attracted attention as future reference clocks in place of present atomic clocks. The Communications Research Laboratory (CRL) has been developing an observation system to measure the pulse timing of a millisecond pulsar precisely, and has recently completed the basic part of the task. We observed PSR1937+21 at 1.5GHz band and got a pulse timing with a precision of 16 micro sec/tau by five days of observation.

Hanado, Yuko↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

Cold atoms in space: community workshop summary and proposed road-map

We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfabricated alkali vapor cell with anti-relaxation wall coating

We present a microfabricated alkali vapor cell equipped with an anti-relaxation wall coating. The anti-relaxation coating used is octadecyltrichlorosilane and the cell was sealed by thin-film indium-bonding at a low temperature of 140 °C. The cell body is made of silicon and Pyrex and features a double-chamber design. Depolarizing properties due to liquid Rb droplets are avoided by confining the Rb droplets to one chamber only. Optical and microwave spectroscopy performed on this wall-coated cell are used to evaluate the cell's relaxation properties and a potential gas contamination. Double-resonance signals obtained from the cell show an intrinsic linewidth that is significantly lower than the linewidth that would be expected in case the cell had no wall coating but only contained a buffer-gas contamination on the level measured by optical spectroscopy. Combined with further experimental evidence this proves the presence of a working anti-relaxation wall coating in the cell. Such cells are of interest for applications in miniature atomic clocks, magnetometers, and other quantum sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DARPA looks beyond GPS for positioning, navigating, and timing

Cold-atom interferometry, microelectromechanical systems, signals of opportunity, and atomic clocks are some of the technologies the defense agency is pursuing to provide precise navigation when GPS is unavailable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of Clocks to Space Navigation & "Planetary GPS"

The ability to fly atomic clocks on GPS satellites has profoundly defined the capabilities and limitations of GPS in near-Earth applications. It is likely that future infrastructure for Lunar and Mars applications will be constrained by financial factors. The development of a low cost, small, high performance space clock -- or ultrahigh performance space clocks -- could revolutionize and drive the entire approach to GPS-like systems at the Moon (or Mars), and possibly even change the future of GPS at Earth. Many system trade studies are required. The performance of future GPS-like tracking systems at the Moon or Mars will depend critically on clock performance, availability of inertial sensors, and constellation coverage. Example: present-day GPS carry 10(exp -13) clocks and require several updates per day. With 10(exp -15) clocks, a constellation at Mars could operate autonomously with updates just once per month. Use of GPS tracking at the Moon should be evaluated in a technical study.

Lichten, Stephen M.↗

Coaxial Electric Heaters

Coaxial electric heaters have been conceived for use in highly sensitive instruments in which there are requirements for compact heaters but stray magnetic fields associated with heater electric currents would adversely affect operation. Such instruments include atomic clocks and magnetometers that utilize heated atomic-sample cells, wherein stray magnetic fields at picotesla levels could introduce systematic errors into instrument readings. A coaxial electric heater is essentially an axisymmetric coaxial cable, the outer conductor of which is deliberately made highly electrically resistive so that it can serve as a heating element. As in the cases of other axisymmetric coaxial cables, the equal magnitude electric currents flowing in opposite directions along the inner and outer conductors give rise to zero net magnetic field outside the outer conductor. Hence, a coaxial electric heater can be placed near an atomic-sample cell or other sensitive device. A coaxial electric heater can be fabricated from an insulated copper wire, the copper core of which serves as the inner conductor. For example, in one approach, the insulated wire is dipped in a colloidal graphite emulsion, then the emulsion-coated wire is dried to form a thin, uniform, highly electrically resistive film that serves as the outer conductor. Then the film is coated with a protective layer of high-temperature epoxy except at the end to be electrically connected to the power supply. Next, the insulation is stripped from the wire at that end. Finally, electrical leads from the heater power supply are attached to the exposed portions of the wire and the resistive film. The resistance of the graphite film can be tailored via its thickness. Alternatively, the film can be made from an electrically conductive paint, other than a colloidal graphite emulsion, chosen to impart the desired resistance. Yet another alternative is to tailor the resistance of a graphite film by exploiting the fact that its resistance can be changed permanently within about 10 percent by heating it to a temperature above 300 C. A coaxial heater, with electrical leads attached, that has been bent into an almost full circle for edge heating of a circular window is shown. (In the specific application, there is a requirement for a heated cell window, through which an optical beam enters the cell.)

Strekalov, Dmitry↗

Transient processes under dynamic excitation of a coherent population trapping resonance

It is shown for the first time that under dynamic excitation of a coherent population trapping resonance in Rb vapours at different bichromatic pump modulation frequencies from a few tens of hertz and higher, the resonance is dramatically deformed as a result of emerging intensity oscillations of radiation transmitted through an Rb vapour cell. A significant change in the shape of the resonance under its dynamic excitation is confirmed experimentally and theoretically. A possible impact of the identified changes in the shape of the coherent population trapping resonance on the stability of an atomic clock is qualitatively discussed. (optical traps)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Space qualified photon counting detector for laser time transfer with picosecond precision and stability

The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stability is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of −55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic effects of the rotation of the earth on remote clock synchronization

A treatment is given of relativistic clock synchronization effects due to the rotation of the earth. Unlike other approaches, the point of view of an earth fixed coordinate system is used which offers insight to many problems. An attempt is made to give the reader an intuitive grasp of the subject as well as to provide formulae for his use. Specific applications to global timekeeping, navigation, VLBI, relativistic clock experiments, and satellite clock synchronization are discussed. The question of whether atomic clocks are ideal clocks is also treated.

Reinhardt, V.↗