Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “assets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of variable renewable energy on wholesale markets and generating assets in the United States: A review of expectations and evidence

Here, we synthesize available literature, data, and analysis on the degree to which growth in variable renewable energy (VRE) has impacted or might in the future impact bulk power system assets, pricing, and costs in the United States. Most studies of future scenarios indicate that VRE reduces wholesale energy prices and capacity factors of thermal generators. Traditional baseload generators are more exposed to these changing market conditions than low-capital cost and more flexible intermediate and peak-load generators. From analysis of historical data we find that VRE is already influencing the bulk power market through changes in temporal and geographic patterns areas with higher levels of VRE. The most significant observed impacts have concentrated in areas with significant VRE and/or nuclear generation along with limited transmission, with negative pricing also often occurring during periods with lower system-wide load. So far, however, VRE, has had a relatively modest impact on historical average annual wholesale prices across entire market regions, at least in comparison to other drivers. The reduction of natural gas prices is the primary contributor to the decline in wholesale prices since 2008. Similarly, VRE impacts on thermal plant retirements have been limited and there is little relationship between the location of recent retirements and VRE penetration levels. Finally, although impacts on wholesale prices have been modest so far, impacts of VRE on the electricity market will be more significant under higher VRE penetrations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Complementarity Analysis of Potential Floating Solar Co-Located With Existing Hydropower Assets Across the Contiguous United States

The U.S. is expected to double its rate of renewable capacity from 2024 to 2030. However, the stochastic nature of renewable energy poses challenges to the operation and reliability of our power grid. The combined generation from renewable energy sources, with dispatchable sources (such as hydropower) operating as a hybrid energy plant, could mitigate this variability. In this paper, the complementarity analysis of selected U.S. reservoirs with existing hydropower assets (EHAs) and potential floating photovoltaics (FPVs) is conducted for the continuous U.S. (CONUS). The optimal FPV capacity for each site is determined by minimizing the variability of the combined output, while adhering to the FPV potential. Our results indicate that over 50% of the analyzed reservoirs achieve a stability coefficient exceeding 0.5, leading to a less-variable output after optimization. Finally, we analyze the complementary hydro-FPV hybrid reservoirs by considering both the Pearson correlation coefficient and the stability coefficient on daily, monthly, and yearly scales. Summaries are included of locations of theoretical FPVs co-located with hydropower plants that exhibit high complementarity based on the selected metrics.

13 - HYDRO ENERGY↗

Towards More Transmission Asset Utilization through Real-time Path Rating

Ratings of transmission paths, typically determined in an offline environment, are static and tend to be conservative, leading to underutilization of transmission assets, higher costs of system operation and renewable energy integration, and lower efficiency and savings. With the ever-increasing transmission congestion costs and new challenges from renewable integration, increasing transfer capacity of existing transmission lines is essential. Real-time path rating provides a promising approach to enabling additional power transfer capability and fully utilizing transfer capability. In this paper, the feasibility of real-time path rating is investigated. Several promising technologies to achieve real-time path rating are discussed. Various benefits that can be expected from real-time path rating, such as increased transfer capability and reduced total generation cost, are demonstrated through simulations conducted on the Western Electricity Coordinating Council system model.

Diao, Ruisheng↗

Assessing the Reliability Benefits of Energy Storage as a Transmission Asset

Utilizing energy storage solutions to reduce the need for traditional transmission investments has been recognized by system planners and supported by federal policies in recent years. This work demonstrates the need for detailed reliability assessment for quantitative comparison of the reliability benefits of energy storage and traditional transmission investments. First, a mixed-integer linear programming expansion planning model considering candidate transmission lines and storage technologies is solved to find the least-cost investment decisions. Next, operations under the resulting system configuration are simulated in a probabilistic reliability assessment which accounts for weather-dependent forced outages. The outcome of this work, when applied to TPPs, is to further equalize the consideration of energy storage compared to traditional transmission assets by capturing the value of storage for system reliability.

co-optimization↗

Chemical Asset Tracker (CAT)

The Chemical Asset Tracker, CAT, is a web-based (browser) application for tracking chemical inventories. The application records information about stored chemicals from user input (via the keyboard, barcode readers, or mobile device) and stores that information into a database. A tiered user login controls access to functions in the application. A user interface is provided that allows users to search the database and update data in the database. SAND2019-7525 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bolles, Jason↗

ASSET (Automated Systemwide Strength Evaluation Tool) [SWR-24-03]

ASSET is a free and open-source tool built with Python and PSS®E, designed to automatically assess and analyze grid strength across large-scale power systems. It supports multiple system operating conditions and contingencies, and outputs results in a tabular format for easy interpretation.

Shah, Shahil [National Renewable Energy Laboratory↗

Post survey report for AOP Assignable Asset collection of Crested Butte, CO

This report contains details of the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) assignable asset (AA) flight over Crested Butte, Colorado (CO). The report is being prepared for Lawrence Berkeley National Lab (LBNL), the primary clients for the flights who contracted the NEON AOP for flights during June 2018. The report includes a summary of the acquired flight lines over the planned area, results of calibration surveys, and quality assurance (QA) results of the acquired data. Detailed reports on the acquired data and processing results were also delivered with the data. LBNL contracted the AA NEON AOP flights to observe watersheds of interest at Crested Butte with remotely sensed data including high resolution LiDAR, imaging spectroscopy, and high-resolution camera imagery. The remote sensing imagery acquired by the AOP intendeds to support LBNL on an interdisciplinary project on hydrology, biogeochemistry, and ecosystem functioning in the area surrounding the Rocky Mountain Biological Laboratory (RMBL), one of the most prominent ecological study sites in the United States.

2018 NEON and 2025 CHESS Campaigns↗

CHESS 2025: Post-survey report for 2025 NEON AOP Assignable Asset collection of East River and Washington Gulch, Almont and Upper Taylor watersheds at Crested Butte, CO

This report contains details of the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) Research Support Services (RSS) Assignable Asset (AA) flights of the East River, Almont and Upper Taylor watersheds near Crested Butte, CO, June–July 2025. The Rocky Mountain Biological Laboratory (RMBL) contracted the NEON AOP AA flights to observe watersheds of interest near Crested Butte with remotely sensed data including high resolution LiDAR, imaging spectroscopy, and high-resolution camera imagery. The report includes a summary of the acquired flight lines over the planned survey areas, results of calibration flights, and results of the acquired data. The report details how the AOP has met the contracted delivery requirements in terms of the data delivered, quality of the data, and describes issues that resulted in data degradation or data loss. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

plutus: An R package to calculate electricity investments and stranded assets from the Global Change Analysis Model (GCAM)

plutus is an R package that post-processes outputs from the Global Change Analysis Model (GCAM) to calculate the power sector capital investment costs and stranded asset costs associated with GCAM projections of electricity generation by technology. GCAM is a market equilibrium model used to examine the dynamics of the coupled human-Earth system and the response of this system to global change, including socioeconomics, technology, climate, and policy. GCAM tracks electricity generation by technology and vintage over 32 geopolitical regions throughout the lifetime of each generating technology. plutus extends GCAM functionality by (1) estimating the foregone economic value of prematurely retired power plants as a result of economic-induced retirements compared to scheduled lifetimes; and (2) estimating the new installations and capital investments driven by future changes in economic, energy, agriculture, and land-use systems in GCAM.

97 MATHEMATICS AND COMPUTING↗

ADEPT Final Report: Dynamic Control of Grid Assets Using Direct AC Converter Cells

Seedling funding was secured through the ARPA-E program to develop a robust, utility-scale Power Converter Augmented Transformer (PCAT). The project designed, fabricated, and tested two 13 kV, 1 MW PCATs operating at an effective switching frequency of up to 50 kHz and at an efficiency of greater than 99%. Two versions of the PCAT were fabricated – one using an imputed DC link (IDCL) topology and the other using a back-to-back (BTB) topology. The IDCL avoids the use of electrolytic capacitors for bulk energy storage, thus improving the lifetime and decreasing the size of the converter, while the BTB topology uses an industry-proven topology that is more commercially viable in the short term. To give the PCAT a lifetime and maintenance profile compatible with typical existing utility assets, a novel Passive Thermal Management System (PTMS) was designed and integrated into both PCATs. The PTMS uses a thermosiphon to remove heat from the power electronic devices without forced cooling and reject it to the ambient environment. In addition, a fail-normal feature was implemented to ensure that in the event of PCAT failure the functionality of the underlying transformer is retained. Attainment of project objectives was verified through testing at the Georgia Tech National Electrical Energy Testing Research and Applications Center (NEETRAC). The IDCL-based PCAT had an efficiency of more than 99.10% and the BTB-based PCAT had an efficiency of more than 99.75%. During testing, the PTMS exceeded project requirements by rejecting the 5 kW output of the converters to a 40 °C environment while keeping devices junction temperatures within their tolerances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Control and Coordination of Distributed Assets for Ancillary Services

The need to diversify energy supplies, the need to mitigate energy-related environmental impact, and the entry of electric vehicles in large numbers present challenges and opportunities to power system professionals. Wind and solar power provide many benefits, and to reap the benefits the resulting increased variability—forecasted as well as unforecasted—should be addressed. A majority of states and the District of Columbia, representing over half of the total load, have passed renewable portfolio standards. California’s plans call for 33% renewable energy by 2020. For grid balancing and for meeting reliability standards, ancillary services are needed. The needs for these services are poised to increase significantly. Demand resources are receiving increasing attention as one means of providing the ancillary services. Control and coordination of a large number (~millions) of distributed smart grid assets requires innovative approaches. One such approach is transactive control and coordination (TC2)—a distributed, hierarchical, agent-based incentive and control system. The TC2 paradigm is to create a market-like control system in which participation is voluntary and the participant sets the price for participation. For transactions that are frequent, automation of bids and responses is necessary. Such an approach has been developed and demonstrated at the Pacific Northwest National Laboratory. The devices, typically thermostatically controlled heating, ventilating, and air conditioning (HVAC) loads, send their bids—the quantity of energy they need and, based on the consumer preferences encoded in a simple user interface, the price they are willing to pay. The typical bid period is 5 minutes. By aggregating all the bids, a demand curve is generated by the aggregating entity, and matched with a supply curve or supply constraint. The aggregator transmits the clearing price to the devices. The winning devices proceed to consume the energy they bid for and won. It is the purpose of this project to develop a similar approach for ancillary services. In this report, the following ancillary services are considered: spinning reserve, ramping, and regulation. These services are to be provided by the following devices: refrigerators, water heaters, clothes dryers, variable speed drives. We will assume that the variable speed drives operate an air handling fan in a commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Smart Grid Asset Control Strategies for Providing Ancillary Services

With large-scale plans to integrate renewable generation driven mainly by state-level renewable portfolio requirements, more resources will be needed to compensate for the uncertainty and variability associated with intermittent generation resources. Distributed assets can be used to mitigate the concerns associated with renewable energy resources and to keep costs down. Under such conditions, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive but also technically difficult. It is therefore important to explore how a sufficient proportion of the loads could assume a routine role in primary frequency control to maintain the stability of the system at an acceptable cost. The main objective of this project is to develop a novel hierarchical distributed framework for frequency based load control. The framework involves two decision layers. The top decision layer determines the optimal gain for aggregated loads for each load bus. The gains are computed using decentralized robust control methods, and will be broadcast to the corresponding participating loads every control period. The second layer consists of a large number of heterogeneous devices, which switch probabilistically during contingencies so that aggregated power change matches the desired amount according to the most recently received gains. The simulation results show great potential to enable systematic design of demand-side primary frequency control with stability guarantees on the overall power system. The proposed design systematically accounts for the interactions between the total load response and bulk power system frequency dynamics. It also guarantees frequency stability under a wide range of time varying operating conditions. The local device-level load response rules fully respect the device constraints (such as temperature setpoint, compressor time delays of HVACs, or arrival and departure of the deferrable loads), which are crucial for implementing real load control programs. The promise of autonomous, Grid Friendly™ response by smart appliances in the form of under-frequency load shedding was demonstrated in the GridWise Olympic Peninsula Demonstration in 2006. Each controller monitored the power grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances responded reliably to each shallow under-frequency event, which was an average of one event per day and shed their loads for the durations of these events. Another objective of this project was to perform extensive simulation studies to investigate the impact of a population of Grid Friendly™ Appliances (GFAs) on the bulk power system frequency stability. The GFAs considered in this report are represented as demonstration units with water heaters individually modeled.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Variable Renewable Energy on Bulk Power System Assets, Pricing, and Costs

We synthesize available literature, data, and analysis on the degree to which growth in variable renewable energy (VRE) has impacted to date or might in the future impact bulk power system assets, pricing, and costs. We do not analyze impacts on specific power plants, instead focusing on national and regional system-level trends. The issues addressed are highly context dependent—affected by the underlying generation mix of the system, the amount of wind and solar penetration, and the design and structure of the bulk power system in each region. Moreover, analyzing the impacts of VRE on the bulk power system is a complex area of research and there is much more to be done to increase understanding of how VRE impacts the dynamics of current and future electricity markets. While more analysis is warranted, including additional location-specific assessments, several high-level findings emerge from this synthesis: -VRE Is Already Impacting the Bulk Power Market -VRE Impacts on Average Wholesale Prices Have Been Modest -VRE Impacts on Power Plant Retirements Have So Far Been Limited -VRE Impacts on the Bulk Power Market will Grow with Penetration -The ’System Value’ of VRE will Decline with Penetration -Power System Flexibility Can Reduce the Rate of VRE Value Decline All generation types are unique in some respect—bringing benefits and challenges to the power system—and wholesale markets, industry investments, and operational procedures have evolved over time to manage the characteristics of a changing generation fleet. With increased VRE penetrations, power system planners, operators, regulators, and policymakers will continue to be challenged to develop methods to smoothly and cost-effectively manage the reliable integration of these new and growing sources of electricity supply.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conventional Generation Asset Management with Renewable Portfolio Standards Using Real Options

The transition to a more renewable generation mix under a competitive electricity market will require individual power producers to use sophisticated tools to value conventional generators. Owners will need to understand what market prices signal new investments, temporarily suspending operation, reactivating mothballed generators or permanently abandoning a plant. Net present valuation from a traditional discounted cash flow analysis is limited in capturing the value of generation technologies, and it does not provide an optimal investment criterion. We present and evaluate a closed-form decision support framework using a Spark Spread Real Options approach to value generation assets and to capture optimal market price signals that minimizes financial risks of individual power producers under a transition towards a more renewable energy fleet. We evaluate the Spark Spread options valuation for capital budgeting without capacity payments. As an example, for a fixed heat rate of 10,000 Btu/kWh and a combined electricity and fuel price annual volatility1 of 58%, the Spark Spread option valuation gives a positive value for a unit of installed generating capacity at electricity prices below $\$$40/MWh. Given the same conditions, a traditional net present value (NPV) cash flow has no value for a unit of installed capacity for electricity prices below $\$$40/MWh. Accounting for the inevitable volatility in electricity and fuel prices can allow firms to see more value in fossil plants than does the traditional approach.

17 WIND ENERGY↗

Adaptive RAS/SPS System Settings for Improving Grid Reliability and Asset Utilization through Predictive Simulation and Controls

Remedial Action Schemes (RAS) or Special Protection Schemes (SPS) are used throughout the bulk transmission system as a non-wires method of increasing transmission transfer capability. However, as the population grows within the Western Interconnection, more power needs to be transferred with less ability to build lines. This leads to a greater number of RAS, and the subsequent interaction between these disparate schemes can have unintended consequences. While the large number of RAS within the Western Electricity Coordinating Council (WECC) protect for different things, which can range from the violation of thermal limitations to transient stability issues, they can be described by common methods of operation. In order to understand these methods, a survey was sent out to members of the WECC Modeling & Validation Working Group (MVWG). The response received provides a necessary base in which to understand and build models that can be used within WECC. This report provides information on the survey results regarding RAS/SPS modeling practices for planning and operational studies within the WECC footprint, which is foundational for on-going and future work on RAS. Pacific Northwest National Laboratory (PNNL) and its industry partners are developing innovative methods for adaptively setting RAS parameters based on realistic and near real-time operational conditions to improve power grid reliability and grid asset utilization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storage Enabled Flexibility of Conventional Generation Assets (StorFlex)

The power systems have faced progressively more demanding operational requirements over the last two decades. Several factors contribute to these challenging operating conditions, including load growth, aging infrastructure, increasing penetrations of distributed energy resources (DERs), electrification of the economy, and policy initiatives such as decarbonization. The power system and its components must provide high operational flexibility to mitigate these challenges. For example, the proliferation of intermittent DERs such as wind and solar has increased the need for conventional generation assets like hydropower plants to respond to sudden load-generation imbalances. The higher flexibility requirements for hydropower plants cause more wear and tear, potentially shortening the useful lifespan of hydropower turbines. To reduce the need for hydropower plants to follow sudden changes in the dispatch signal, we investigate their combined operation with the energy storage systems (ESSs; “ESS-based hybridization”). Our analyses focuses on improving the lifespan of hydropower plants through ESS-based hybridization. Wear and tear on hydropower turbines (particularly Francis turbines) is modeled using a loss-of-life concept that is based on damage experienced by the turbine due to various cycles of operation. Then, we show that using ESSs to offset some of the high variation increases the remaining life of the hydropower plants. To demonstrate this, a few modeling tools were developed for this work: (1) a dynamic model for various components of the turbine and its governor; (2) a control strategy that assigns a slow-varying dispatch signal to a hydropower unit versus a fastmoving signal to ESS, such that the overall power request remains the same; and (3) models for the financial analysis to quantify the economic merits of such a framework. We used the models we developed to analyze the dispatch pattern of an actual hydropower plant with a power output of 50 MW and a head height of 152 m. This work showed that ESS-based hybridization could extend the life of the hydropower plant by 5% on average. This extension in life was then used to estimate the economic benefit in terms of cost deferrals associated with hydropower plant maintenance and replacement: on average, $3.6 million. Sensitivity analysis with respect to the size of ESS and cost of turbines was performed to show the variation in benefits over the range of turbine costs and ESS sizes. Crucially, stacking damage reduction and lifetime extension with other ESS value streams such as providing ancillary services could substantially increase the financial benefits of ESS-based hybridization. The higher costs associated with ESS of appropriate size would make more financial sense when multiple value streams are stacked and co-optimized to extract the maximum benefit. This dimension will be explored in future work.

13 HYDRO ENERGY↗