Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Laboratory measurements and a theoretical analysis of the TCT fading channel radio system

This paper documents the laboratory and theoretical performance of a pilot-aided digital radio system. The technique considered transmits a midband pilot tone to improve the receiver data detection performance in a multipath fading channel and is referred to as the tone calibrated technique (TCT). The performance of a 860 MHz prototype system carrying 2.4 kbit/s data under Rician fading conditions is reported. Both experimental and analytical results show that the error floor experienced with nonpilot-aided transmission methods is effectively removed by the TCT scheme, resulting in significant performance gains at high signal-to-noise ratio values. The paper also examines the TCT system performance under typical operating conditions and presents a new analysis of the TCT theoretical error probability.

Rafferty, William↗

A microarray immunoassay for simultaneous detection of proteins and bacteria

We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

Non-NASA Center↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Chemiluminescent measurement of atmospheric acid

The design and construction of a gas phase acid sensitive analyzer are reported. These studies showed that the chemical system was a practical analytical method. A complete instrument was developed and prepared for field testing. A Titan 3-C rocket was scheduled for launching on February 11, 1974. Through preparations made by NASA Langley the instrument was set up to monitor the acid concentration in the rocket exhaust. Due to adverse wind conditions no acid was detected. This entire trip is described in detail.

Stedman, D. H.↗

Lipid Biomarkers for Methanogens in Hypersaline Cyanobacterial Mats for Guerrero Negro, Baja California Sur

Analyses of sediments from the vicinity of active methane seeps have uncovered a particular suite of lipid biomarker patterns that characterize methane consuming archaea and their syntrophic, sulfate reducing partners. These isoprenoid biomarkers, largely identified by their anomalously light carbon isotopic signatures, have been a topic of intense research activity and are recorded in numerous methane-rich environments from Holocene to Cenozoic. This phenomenon has implications for depleted kerogens at 2.7 Ga on early Earth (Hinrichs 2002). In contrast, the lipid biosignatures of methane producing archaea are not readily identified through distinct isotopic labels and have received comparably little attention in analyses of archaea in environmental samples. Indeed, environmental analyses generally detect only free archaeal lipids, not the intact, polar molecules found in the membrane of living organisms. As part of the Ames NAI, the 'Early Microbial Ecosystem Research Group' (EMERG) is working to understand microbial processes in the hypersaline cyanobacterial mats growing in the salt evaporation ponds of the Exportadora de Sal at Guerrero Negro, Baja California Sur, Mexico. The aim of this study was to develop methods by which we could identify the organisms responsible for methane generation in this environment. While the ester-bound fatty acids, hopanoids and wax esters provide a means to identify most of the bacterial components of these mats, the archaea which Ere evidently present through genomic assays and the fact of intense methane production (Hoehler et al. 200l), have not been identified through their corresponding lipid signatures. Archaeal core lipids present a number of analytical challenges. The core lipids of methanogens comprise C20, C40 and sometimes C25 isoprenoid chains, linked through ether bonds to glycerol. As well as archaeal (C20), sn-2- and sn-3-hydroxyarchaeol are associated particularly with methylotrophic methanogens. Recently, we have also identified a dihydroxyarchaeol in a hyperthermophilic methanogen (Summons et al. 2002). Additional structural diversity is encoded into the polar head groups that are attached to the glycerol ether cores. The C20 core lipids are readily analyzed by GC-MS as their volatile trimethylsilyl derivatives while compounds with intact polar head groups can only be detected using LC-MS approaches. Our approach was to utilize the alternative of an ether cleavage reagent (BBr3 vs. HI) and a hydride reducing agent to convert all ether lipids to hydrocarbon in order to provide a vertical profile of quantitative information that might be matched to methane fluxes. We have found that while conventional acid hydrolysis and HI treatment will destroy hydroxyarchaeols, molecular information remains intact through use of BBr3 for ether cleavage. This method revealed the presence of traces of biphytane and various ether alkyls associated with some sulfate reducing bacteria within the mat structure. An interesting, and potentially valuable, byproduct of the method utilizing HI was the identification of abundant homohopanoids after superhydride reduction. Evidently present as sulfur-bound diagenetic products these hopanoids are likely cyanobacterial biomarkers in the early stages of diagenetic preservation.

Jahnke, Linda L.↗

Applications of luminescent systems to infectious disease methodology

The characterization of a clinical sample by a simple, fast, accurate, automatable analytical measurement is important in the management of infectious disease. Luminescence assays offer methods rich with options for these measurements. The instrumentation is common to each assay, and the investment is reasonable. Three general procedures were developed to varying degrees of completeness which measure bacterial levels by measuring their ATP, FMN and iron porphyrins. Bacteriuria detection and antibiograms can be determined within half a day. The characterization of the sample for its soluble ATP, FMN or prophyrins was also performed.

Picciolo, G. L.↗

Certification methodology applied to the NASA experimental radar system

The objective of the research is to apply selected FAA certification techniques to the NASA experimental wind shear radar system. Although there is no intent to certify the NASA system, the procedures developed may prove useful to manufacturers that plan to undergo the certification process. The certification methodology for forward-looking wind shear detection radars will require estimation of system performance in several FAA-specified microburst/clutter scenarios as well as the estimation of probabilities of missed and false hazard alerts under general operational conditions. Because of the near-impossibility of obtaining these results experimentally, analytical and simulation approaches must be used. Hazard detection algorithms were developed that derived predictive estimates of aircraft hazard from basic radar measurements of weather reflectivity and radial wind velocity. These algorithms were designed to prevent false alarms due to ground clutter while providing accurate predictions of hazard to the aircraft due to weather. A method of calculation of the probability of missed and false hazard alerts has been developed that takes into account the effect of the various algorithms used in the system and provides estimates of the probability of missed and false alerts per microburst encounter under weather conditions found at Denver, Kansas City, and Orlando. Simulation techniques have been developed that permit the proper merging of radar ground clutter data (obtained from flight tests) with simulated microburst data (obtained from microburst models) to estimate system performance using the microburst/clutter scenarios defined by the FAA.

Britt, Charles L.↗

Pollution Monitoring: An Engineering Challenge

One purpose in presenting this material is to bring to the attention of engineers background material which they would not normally encounter in the course of routine development work. An excellent and timely reference is as follows: Seminar on Methods of Detection, Measurement and Monitoring of Pollutants in the Marine Environment. The international seminar was organized by FAO with the support of UNESCO, IAEA, SCOR and WMO, and was held in Rome, Italy, 4-10 December 1970. The final report, the title of which was given, is a very thoroughgoing document and certainly a must reference for anyone seriously considering the development of sensors for pollution measurement. Perhaps it would be appropriate to present some exact quotations selected from the referenced document. The quotations follow: 1) "The pressures to develop sensitive and reliable methods come about when those responsible for the management of our environment need an objective evaluation of existing or potential perils." 2) "Nearly all of the Panels concerned with the contaminants identified specific examples of man's waste products which may be leaking to the environment in substantial quantities and for which as yet there are no analytical techniques available ". 3) "Very few analyses for organochlorine pesticides appear to have been carried out on sea water and the panel considered that the present methodology was not capable of detecting, on a routine basis, the quantities of these compounds in open sea waters." and 4) "This corresponds essentially to the ratio of useful data produced to the labour expended, since instrumentation costs in the long run become negligible."

Snodgrass, J. M.↗

An implicit shock-fitting scheme for unsteady transonic flow computations

The alternating-direction implicit scheme developed by NASA Ames for unsteady transonic flows has been modified to include a shock-fitting algorithm as well as an analytically stretched coordinate system. The shock-fitting procedure treats shock waves as discontinuities normal to the free stream. Improvements in shock position and the unsteady pressure distributions are obtained by this modification. The various types of shock motion observed experimentally by Tijdeman are well simulated in calculations using the modified computational scheme. The method of detecting shock wave formation and the procedure for fitting a moving shock wave are illustrated. Results for a pulsating parabolic arc airfoil and for an NACA 64A006 airfoil with oscillating quarter-chord flap are presented and discussed.

Yu, N. J.↗

NIAC Phase I Final Report: On-Orbit, Collision-Free Mapping of Small Orbital Debris

Sub-centimeter orbital debris is currently undetectable using ground-based radar and optical methods. However, the pits in Space Shuttle windows produced by paint chips (e.g. the 3.8mm diameter pit produced by a 0.2mm paint chip on STS-7) demonstrate that small debris can cause serious damage to spacecraft. Recent analytical, computational and experimental work has shown that charged objects moving quickly through a plasma will cause the formation of solitons in the plasma density. Due to their exposure to the solar wind plasma environment, even the smallest space debris will be charged. Depending on the debris size, charge and velocity, the plasma signature of the solitons may be detected by simple instrumentation on spacecraft. We will describe the amplitude and velocity of solitons that may be produced by mm-cm scale orbital debris in LEO. We will discuss the feasibility of mapping sub-cm orbital debris using a fleet of CubeSats equipped with Langmuir probes. The time and fleet size required to map the debris will also be described. Plasma soliton detection would be the first collision-free method of mapping the small debris population.

Orbital Debris↗

Differential detection of Gaussian MSK in a mobile radio environment

Minimum shift keying with Gaussian shaped transmit pulses is a strong candidate for a modulation technique that satisfies the stringent out-of-band radiated power requirements of the mobil radio application. Numerous studies and field experiments have been conducted by the Japanese on urban and suburban mobile radio channels with systems employing Gaussian minimum-shift keying (GMSK) transmission and differentially coherent reception. A comprehensive analytical treatment is presented of the performance of such systems emphasizing the important trade-offs among the various system design parameters such as transmit and receiver filter bandwidths and detection threshold level. It is shown that two-bit differential detection of GMSK is capable of offering far superior performance to the more conventional one-bit detection method both in the presence of an additive Gaussian noise background and Rician fading.

Simon, M. K.↗

Detection of faults and software reliability analysis

Multiversion or N-version programming was proposed as a method of providing fault tolerance in software. The approach requires the separate, independent preparation of multiple versions of a piece of software for some application. Specific topics addressed are: failure probabilities in N-version systems, consistent comparison in N-version systems, descriptions of the faults found in the Knight and Leveson experiment, analytic models of comparison testing, characteristics of the input regions that trigger faults, fault tolerance through data diversity, and the relationship between failures caused by automatically seeded faults.

Knight, J. C.↗

Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions

In the robotic search for life on Mars, different proposed missions will analyze the chemical and biological signatures of life using different platforms. The analysis of samples via analytical instrumentation on the surface of Mars has thus far only been attempted by the two Viking missions. Robotic arms scooped relogith material into a pyrolysis oven attached to a GC/MS. No trace of organic material was found on any of the two different samples at either of the two different landing sites. This null result puts an upper limit on the amount of organics that might be present in Martian soil/rocks, although the level of detection for each individual molecular species is still debated. Determining the absolute limit of detection for each analytical instrument is essential so that null results can be understood. This includes investigating the trade off of using pyrolysis versus liquid solvent extraction to release organic materials (in terms of extraction efficiencies and the complexity of the sample extraction process.) Extraction of organics from field samples can be accomplished by a variety of methods such utilizing various solvents including HCl, pure water, supercritical fluid and Soxhelt extraction. Utilizing 6N HCl is one of the most commonly used method and frequently utilized for extraction of organics from meteorites but it is probably infeasible for robotic exploration due to difficulty of storage and transport. Extraction utilizing H2O is promising, but it could be less efficient than 6N HCl. Both supercritical fluid and Soxhelt extraction methods require bulky hardware and require complex steps, inappropriate for inclusion on rover spacecraft. This investigation reports the efficiencies of pyrolysis and solvent extraction methods for amino acids for different terrestrial samples. The samples studied here, initially created in aqueous environments, are sedimentary in nature. These particular samples were chosen because they possibly represent one of the best terrestrial analogs of Mars and they represent one of the absolute best case scenarios for finding organic molecules on the Martian surface.

Beegle, L. W.↗

Annular truncated plug nozzle flowfield and base pressure characteristics.

The flowfield and base pressure characteristics of an internal-external expansion, truncated plug nozzle are described over the pressure ratio range from 'open' wake to 'closed' wake conditions. The effect of plug length on these characteristics, including the process of wake 'closure' is also presented. An existing method for calculating the flowfield and base pressure, for 'closed' wake operation, is modified to include the internal shock wave generated near the shroud exit. The supersonic portion of the flow is calculated using rotational axisymmetric method of characteristics. The technique of Hartree is employed so that the downstream characteristic point locations can be chosen to fit the developing flowfield. An overexpansion technique is used to detect the internal shock wave in the vicinity of the shroud exit so that its effect on the plug base pressure could be determined. Good agreement between the analytical results and experimental data is obtained for 'closed' wake operations.

Sule, W. P.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

Laser↗

Method for detection of selected chemicals in an open environment

The present invention relates to a space-invariant independent component analysis and electronic nose for detection of selective chemicals in an unknown environment, and more specifically, an approach to analysis of sensor responses to mixtures of unknown chemicals by an electronic nose in an open and changing environment. It is intended to fill the gap between an alarm, which has little or no ability to distinguish among chemical compounds causing a response, and an analytical instrument, which can distinguish all compounds present but with no real-time or continuous event monitoring ability.

Duong, Tuan↗

High temperature ion channels and pores

The present invention includes an apparatus, system and method for stochastic sensing of an analyte to a protein pore. The protein pore may be an engineer protein pore, such as an ion channel at temperatures above 55.degree. C. and even as high as near 100.degree. C. The analyte may be any reactive analyte, including chemical weapons, environmental toxins and pharmaceuticals. The analyte covalently bonds to the sensor element to produce a detectable electrical current signal. Possible signals include change in electrical current. Detection of the signal allows identification of the analyte and determination of its concentration in a sample solution. Multiple analytes present in the same solution may also be detected.

Kang, Xiaofeng↗