Aerodynamic Performance and Static Stability at Mach Numbers of Up to 5 of Two Airplane Configurations with Favorable LIft interference
Performance and static stability of supersonic aircraft configuration with lift interference
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance and static stability of supersonic aircraft configuration with lift interference
Design of test facility and prototype fan for turbofan acoustic research
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A turbine stator vane was tested in a two-dimensional cascade of 10 vanes and in a single-vane tunnel. The single-vane tunnel was a cold air version of a tunnel which will be used for high temperature heat transfer testing of cooled turbine vanes. The purpose of the investigation was to determine if the flow conditions in the single-vane tunnel were sufficiently similar to those of a 10-vane cascade to permit meaningful heat transfer testing. The vane was tested over a range of ideal exit critical velocity ratios. The principal measurements were vane surface static pressure and cross-channel surveys of exit static pressure, total pressure, and flow angle. A brief description of the test vane and tunnels is included. The results of the exit surveys, the vane surface pressure distributions, and overall performance in terms of flow and loss for the two test configurations are compared.
Explore the source record for details and available documents.
Trailing-edge slot configurations were investigated in a two-dimensional cascade of turbine stator blades. The trailing-edge slots were incorporated into blades with round trailing edges. The five blade configurations investigated included blades with two different trailing-edge thicknesses and four different slot widths. The results of the investigation showed that there was, in general, a significant increase in primary-air efficiency due to the coolant flow, the increase varying with slot configuration. For the five configurations tested, the average percent change in primary-air efficiency per percent coolant flow varied almost linearly from zero to about 1.4 percent over a range of coolant- to primary-air exit-velocity ratios between 0 and 1.2. However, for different configurations there was considerable deviation from the average values in the lower range of exit velocity ratios.
Experimental data have been obtained for two series of bodies at Mach 6 and Reynolds numbers, based on model length, from 1.4 million to 9.5 million. One series consisted of axisymmetric power-law bodies geometrically constrained for constant length and base diameter with values of the exponent n of 0.25, 0.5, 0.6, 0.667, 0.75, and 1.0. The other series consisted of positively and negatively cambered bodies of polygonal cross section, each having a constant longitudinal area distribution conforming to that required for minimizing zero-lift wave drag at hypersonic speeds under the geometric constraints of given length and volume. At the highest Reynolds number, the power-law body for minimum drag is blunter (exponent n lower) than predicted by inviscid theory (n approximately 0.6 instead of n = 0.667); however, the peak value of lift-drag ratio occurs at n = 0.667. Viscous effects were present on the bodies of polygonal cross section but were less pronounced than those on the power-law bodies. The trapezoidal bodies with maximum width at the bottom were found to have the highest maximum lift-drag ratio and the lowest mimimum drag.
Explore the source record for details and available documents.
Experimentally determined efficiencies of turbine stator blades having trailing-edge coolant ejection are compared with efficiencies predicted from two previously published approximate analytical methods. The experimental results were obtained from two-dimensional data with the temperature of the primary and coolant flows both being nearly ambient. Data from five stator blade configurations having different slotted trailing-edge geometries were included in the comparison. The two analytical methods gave results which agreed reasonably well with experimental results. An average of the absolute values of differences between experimental and predicted efficiencies for all five blade configurations showed that one method gave average efficiency differences which were about 1.3 percent different than experimental efficiencies, while the other method gave average efficiency differences that were about 0.7 percent different than experimental. However, in some instances, maximum differences of as much as 4 percent occurred. A comparison between experimental and analytical results indicated that the ratio of trailing-edge slot width to trailing-edge thickness influences the measured efficiencies to a greater extent than is accounted for by either analytical model.
Various analytical approaches to predicting the performance of film cooled turbine blades are reviewed. A two-dimensional cascade flow solution is developed for calculating the effects of the coolant injection on the total flow field. This solution is used with an available analytical performance predicting method to provide an improved method. Comparisons are made with experimental data and other analytical results.
A scale model of the JT8D refan stage was tested with a scale model of the S-duct inlet design for the refanned Boeing 727 center engine. Detailed survey data of pressures, temperatures, and flow angles were obtained over a range of flows at speeds from 70 to 97 percent of design speed. Two S-duct configurations were tested; one with a bellmouth inlet and the other with a flight lip inlet. The results indicated that the overall performance was essentially unaffected by the distortion generated by the S-duct inlet. The stall weight flow increased by less than 0.5 kg/sec (approximately 1.5% of design flow) with the S-duct inlet compared with that obtained with uniform flow. The detailed measurements indicated that the inlet guide vane (IGV) significantly reduced circumferential variations. For example, the flow angles ahead of the IGV were positive in the right half of the inlet and negative in the left half. Behind the IGV, the flow angles tended to be more uniform circumferentially.
Computer program analyzes performance of jet-flap wings. Fast and easy-to-use prediction technique, it generates accurate solutions for wide range of wing geometries and trailing-edge jet momentum distributions. Analysis is based on optimized vortex-lattice approach and results in rapid convergence of both overall and distributed loadings.
Inlets for tilt-nacelle VTOL aircraft must operate over a wide range of incidence angles and engine weight flows without internal flow separation. Wind tunnel tests of scale model inlets were conducted to evaluate the effectiveness of three geometric variables to provide this capability. Increasing the lip contraction ratio increased the separation angle at all engine weight flows. The optimum axial location of the centerbody occurred when its leading edge was located just downstream of the inlet lip. Compared with a short centerbody, the optimum location of the centerbody resulted in an increase in separation angle at all engine weight flows. Decreasing the lip major-to-minor-axis ratio increased the separation angle at the lower engine weight flows.
Volume 1 of a three volume report is presented. Volume 1 contains a description of the acoustic configurations, test facilities, data reduction techniques, test conditions, and detailed test results from the hot, static acoustic tests.
Volume 2 of a three volume report is presented. Volume 2 presents acoustic data comparisons in graphic form.
The performance of a variable pitch fan stage tested over a range of blade setting angles, speeds, and flows is presented. The fan was designed for a tip speed of 289.6 m/sec and a flow of 29.6 kg/sec. The measured performance agreed reasonably well with the design point. The stall margin was only 5 percent. Static thrust values along an operating line ranged from less than 15 to over 115 percent of that at design angle as the blade setting angle was varied from 25 degrees (closed) to -8 degrees (opened). The use of casing treatment increased the stall margin to 20.6 percent but decreased efficiency by 4 percentage points.