Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “actuators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

On the role of oxygen in dielectric barrier discharge actuation of aerodynamic flows

Phase-locked particle image velocimetry is used to study the mechanism of induced flow in the near field of a rf dielectric barrier discharge actuator mounted in the separated flow region of a bluff body. Flow actuation is found to be asymmetric, with suction toward the buried downstream electrode when it is biased positively relative to the upstream exposed electrode. Lesser flow is seen on the reverse voltage swing, where the buried electrode should attract positive ions. This phenomenon is enhanced when oxygen is added to the flow, suggesting that oxygen negative ions, possibly O{sub 2}{sup -}, play a dominant role in plasma actuation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Force approximation for a plasma actuator operating in atmospheric air

A plasma actuator has been studied using a self-consistent multibody system of quiescent air, plasma, and dielectric. Equations governing the motion of charged and neutral species have been solved with Poisson's equation. Based on first principles analysis, a functional relationship between electrodynamic force and electrical and physical control parameters has been approximated and numerically tested for air. The magnitude of approximated force increases with the fourth power of the amplitude of rf potential. Thus, the induced fluid velocity also increases. The induced velocity shows momentum injection very close to the actuator surface. There is, however, a very small increase in the induced velocity with the forcing frequency. For the specific range of operational parameters considered, the proposed force relation may help speed up the plasma actuator design process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Force generation due to three-dimensional plasma discharge on a conical forebody using pulsed direct current actuators

Understanding the behavior of three-dimensional plasmas around a pulsed dc actuator can be useful for its efficient operation in many applications. The effect of such actuators is studied using a self-consistent multibody system of neutral oxygen species and its plasma. The equations governing the motion of charged species are solved with the drift diffusion approximation. The electrostatic potential is computed from Poisson's equation. The electric field and ionization level are the highest close to the junction of electrodes and dielectric. The plasma body force thus generated also follows a similar characteristic. Results also show some dc corona instabilities. The temporal average of such force shows mostly acceleration from anode to cathode above the actuator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experimental study of a plasma actuator in absence of free airflow: Ionic wind velocity profile

In this study, we are interested in the direct current electrical corona discharge created between two wire electrodes. The experimental results are related to some electroaerodynamic actuators based on the direct current corona discharge at the surface of a dielectric material. Several geometrical forms are selected for the dielectric surface, such as a plate, a cylinder, and a NACA 0015 aircraft wing. The current density-electric field characteristics are presented for different cases in order to determine the discharge regimes. The corona discharge produces nonthermal plasma, so it is called plasma discharge. Plasma discharge creates a tangential ionic wind above the surface at the vicinity of the wall. The ionic wind induced by the corona discharge is measured in absence of free external airflow. The ionic wind velocity profiles and the maximum induced tangential force are given for different surface forms, so it is possible to compare the actuators effect based on the span of the ionic wind velocity and thrust values. The higher ionic wind velocity is obtained with the NACA profile, which shows the effectiveness of this actuator for the airflow control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Seesaw actuation of atomic force microscope probes for improved imaging bandwidth and displacement range

The authors describe a method of actuation for atomic force microscope (AFM) probes to improve imaging speed and displacement range simultaneously. Unlike conventional piezoelectric tube actuation, the proposed method involves a lever and fulcrum ''seesaw'' like actuation mechanism that uses a small, fast piezoelectric transducer. The lever arm of the seesaw mechanism increases the apparent displacement range by an adjustable gain factor, overcoming the standard tradeoff between imaging speed and displacement range. Experimental characterization of a cantilever holder implementing the method is provided together with comparative line scans obtained with contact mode imaging. An imaging bandwidth of 30 kHz in air with the current setup was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airflow influence on the discharge performance of dielectric barrier discharge plasma actuators

In the present work, the effect of the airflow on the performance of dielectric barrier discharge plasma-actuators is investigated experimentally. In order to analyze the actuator's performance, luminosity measurements have been carried out simultaneously with the recording of the relevant electrical parameters. A performance drop of about 10% is observed for the entire measured parameter range at a flow speed of M = 0.145 (U{sub {infinity}}=50 m/s). This insight is of particular importance, since the plasma-actuator control authority is already significantly reduced at this modest speed level. The results at higher Mach numbers (0.4<M<0.8) reveal an even more pronounced reduction of about 30%. From the combined analysis, the conclusion is drawn that the decreasing electrical performance P{sub A} correlates closely with the decreasing luminosity peak intensity G-caret for increasing airflow velocities. Two non-dimensional scaling numbers are proposed to characterize and quantify the airflow influence. It is demonstrated that these numbers span a universal performance drop diagram for the entire range of investigated operating parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficiency of plasma actuator ionization in shock wave modification in a rarefied supersonic flow over a flat plate

This paper describes experimental and numerical investigations focused on the shock wave modification, induced by a dc glow discharge, of a Mach 2 flow under rarefied regime. The model under investigation is a flat plate equipped with a plasma actuator composed of two electrodes. The glow discharge is generated by applying a negative potential to the upstream electrode, enabling the creation of a weakly ionized plasma. The natural flow (i.e. without the plasma) exhibits a thick laminar boundary layer and a shock wave with a hyperbolic shape. Images of the flow obtained with an ICCD camera revealed that the plasma discharge induces an increase in the shock wave angle. Thermal effects (volumetric, and at the surface) and plasma effects (ionization, and thermal non-equilibrium) are the most relevant processes explaining the observed modifications. The effect induced by the heating of the flat plate surface is studied experimentally by replacing the upstream electrode by a heating element, and numerically by modifying the thermal boundary condition of the model surface. The results show that for a similar temperature distribution over the plate surface, modifications induced by the heating element are lower than those produced by the plasma. This difference shows that other effects than purely thermal effects are involved with the plasma actuator. Measurements of the electron density with a Langmuir probe highlight the fact that the ionization degree plays an important role into the modification of the flow. The gas properties, especially the isentropic exponent, are indeed modified by the plasma above the actuator and upstream the flat plate. This leads to a local modification of the flow conditions, inducing an increase in the shock wave angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of static and dynamic behavior of functionally graded piezoelectric actuated Poly-Si micro cantilever probe

In the present paper a novel functionally graded piezoelectric (FGP) actuated Poly-Si micro cantilever probe is proposed for atomic force microscope. The shear piezoelectric coefficient d{sub 15} has much higher value than coupling coefficients d{sub 31} and d{sub 33}, hence in the present work the micro cantilever beam actuated by d{sub 15} effect is utilized. The material properties are graded in the thickness direction of actuator by a simple power law. A three dimensional finite element analysis has been performed using COMSOL Multiphysics® (version 4.2) software. Tip deflection and free vibration analysis for the micro cantilever probe has been done. The results presented in the paper shall be useful in the design of micro cantilever probe and their subsequent utilization in atomic force microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flexible magnetic composites for light-controlled actuation and interfaces

The interaction between light and matter has been long explored, leading to insights based on the modulation and control of electrons and/or photons within a material. An opportunity exists in optomechanics, where the conversion of radiation into material strain and actuation is currently induced at the molecular level in liquid crystal systems, or at the microelectromechanical systems (MEMS) device scale, producing limited potential strain energy (or force) in light-driven systems. We present flexible material composites that, when illuminated, are capable of macroscale motion, through the interplay of optically absorptive elements and low Curie temperature magnetic materials. These composites can be formed into films, sponges, monoliths, and hydrogels, and can be actuated with light at desired locations. Finally, light-actuated elastomeric composites for gripping and releasing, heliotactic motion, light-driven propulsion, and rotation are demonstrated as examples of the versatility of this approach.

42 ENGINEERING↗

Cavity optoelectromechanical system combining strong electrical actuation with ultrasensitive transduction

A cavity optoelectromechanical system is reported which combines the ultrasensitive transduction of cavity optomechanical systems with the electrical actuation of nanoelectromechanical systems. Ultrasensitive mechanical transduction is achieved via optomechanical coupling. Electrical gradient forces as large as 0.40 {mu}N are realized, facilitating strong actuation with ultralow dissipation. A scanning probe microscope is implemented, capable of characterizing the mechanical modes. The integration of electrical actuation into optomechanical devices is an enabling step toward the regime of quantum nonlinear dynamics and provides capabilities for quantum control of mechanical motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric actuator modification on a turbine driven feed pump at Calvert Cliffs nuclear power plant - 296

Feedwater systems are a leading contributor to unit SCRAMs as indicated by the 2015 INPO data, where 9 of the 51 SCRAMs recorded were a result of feedwater issues. Digital feedwater control systems and enhanced feed pump control modifications can greatly improve performance and control of the plant feedwater systems and help drive down the potential for reactivity management events and unit SCRAMs. Westinghouse has a strong background in the implementation of digital feedwater control systems, and in planning for a recently completed feedwater control system upgrade at Calvert Cliffs, the Westinghouse team worked with Calvert Cliffs to design a solution to a number of common operational issues. Primarily, improving feedwater control over the entire operating range, eliminating single points of vulnerability (SPV) in the feedwater/feed pump systems and eliminating operational issues with the feed pump steam admission valve hydraulic control oil system. A robust first-of-a-kind design and implementation program was undertaken to split the existing hydraulic valve gear actuator with separate electric actuators. Westinghouse worked with Calvert Cliffs and Emerson Process Management (EPM) to install and commission General Electric (GE) feed pump turbines with separate electric actuators for the high-pressure (HP) and low-pressure (LP) steam admission valves. This successful mechanical and control modification was a first for both the nuclear and non-nuclear power generation industries. Westinghouse is working with a number of other utilities to implement similar modifications for PWR and BWR feed pump applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SELF-HEALING PNEUMATIC ACTUATOR DIAPHRAGMS

In the oil and gas industry, damaged diaphragms in pneumatic actuators can lead to unintended methane leaks, increasing emissions. In this work, replacement self-healing diaphragms are manufactured for a commercial pneumatic actuator. To enable self-healing, hollow microvascular networks are created within the diaphragms using sacrificial 3D printed PLA w/ tin(II) oxalate. These microvascular networks are filled with healing chemistries and, upon damage, rupture. After rupturing, the healing chemistries mix and cure to “heal” the damage and reduce leaks. Separate actuator test stands using nitrogen gas and using natural gas were developed to assess the healing performance of diaphragms. A fatigue stand was also developed to evaluate the effects of the different microvascular network geometries on the fatigue life of diaphragms. Our results demonstrate self-healing in diaphragms subjected to damage and tested for leaks. In fatigue testing, our results indicate that the introduction of microvascular networks does not influence the fatigue life.

Self-healing, pneumatic actuator↗

Buckling Pneumatic Linear Actuators Inspired by Muscle

To being, the mechanical features of biological muscles are difficult to reproduce completely in synthetic systems. A new class of soft pneumatic structures (vacuum-actuated muscle-inspired pneumatic structures) is described that combines actuation by negative pressure (vacuum), with cooperative buckling of beams fabricated in a slab of elastomer, to achieve motion and demonstrate many features that are similar to that of mammalian muscle.

36 MATERIALS SCIENCE↗

A helical actuator driven by biased SMA: design, model, and experiment

A helical actuator driven by biased shape memory alloy (SMA) patterns embedded into a soft composite ribbon base is presented in this work. Instead of common U-shape SMA wires, a single SMA wire is woven into planar patterns, which enable helical deformation of the composite ribbon from an initially flat geometry. An analytical static model is established for accurate and rapid prediction of the helical reconfiguration arising from the shape memory effect of woven SMA patterns, followed by validation of the static model using the finite element method (FEM). The finite element results are compared with the analytical solutions given by this static model, which show a high agreement. Parametric study of the influences of eight independent design variables on the dependent helical parameters, such as combined curvatures, pitches, and helical angles, is completed. It is found that the helically deformed geometry is mainly dominated by diameters, biased positions, inclined angles, and numbers of skewed segments of the SMA wire. Fabrication and in-situ experimental test of a prototype of such helical actuators qualitatively demonstrate its dramatic three-dimensional (3D) spiral reconfiguration from a two-dimensional (2D) flat ribbon. In conclusion, such SMA patterns will allow more diverse designs of soft actuators for a wider range of robotic applications.

36 MATERIALS SCIENCE↗

Heating and current drive actuators study for FNSF in the ion cyclotron and lower hybrid range of frequency

This paper addresses considerations for the radio frequency (RF) heating and current drive actuators on the Fusion Nuclear Science Facility (FNSF), focusing on the Lower Hybrid Range of Frequency (LHRF) and Ion Cyclotron Range of Frequency (ICRF). FNSF will require long (~months), steady-state pulses to fulfill its mission of high neutron fluence operation for the qualification of fusion nuclear technologies prototypical for a power plant. RF actuators are uniquely capable of sustaining the plasma without requiring large line-of-sight penetrations through the breeding blanket, which mitigates the impact on tritium breeding and neutron shielding. The technology for generation and transmission of RF waves in the LHRF and ICRF are fully mature, however the lifetime of plasma-facing antenna components in the reactor environment remains a significant technology gap. Moving the location of RF actuators from the low field side (LFS) to the high field side (HFS) of the tokamak reduces fluxes of turbulent plasma and energetic particles to the antenna. Compact HFS antenna designs are able to fit within the blanket sectors with minimal impact on overall dimensions. However, material choices for antenna structures represent a significant challenge. Existing materials are unable to simultaneously meet the requirements for high conductivity, high strength, high temperature, and low activation. Pathways forward with respect to materials development are identified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Canister valve and actuator deposition in metered dose inhalers formulated with low-GWP propellants

A challenge in pressurised metered-dose inhaler (pMDI) formulation design is management of adhesion of the drug to the canister wall, valve and actuator internal components and surfaces. Wall-material interactions differ between transparent vials used for visual inspection and metal canister pMDI systems. This is of particular concern for low greenhouse warming potential (GWP) formulations where propellant chemistry and solubility with many drugs are not well understood. In this study, we demonstrate a novel application of X-ray fluorescence spectroscopy using synchrotron radiation to assay the contents of surrogate solution and suspension pMDI formulations of potassium iodide and barium sulphate in propellants HFA134a, HFA152a and HFO1234ze(E) using aluminium canisters and standard components. Preliminary results indicate that through unit life drug distribution in the canister valve closure region and actuator can vary significantly with new propellants. For solution formulations HFO1234ze(E) propellant shows the greatest increase in local deposition inside the canister valve closure region as compared to HFA134a and HFA152a, with correspondingly reduced actuator deposition. This is likely driven by chemistry changes. For suspension formulations HFA152a shows the greatest differences, due to its low specific gravity. These changes must be taken into consideration in the development of products utilising low-GWP propellants.

60 APPLIED LIFE SCIENCES↗

Thermal actuation in $\mathrm{TRPV1}$: Role of embedded lipids and intracellular domains

The transient response potential cation channel TRPV1 responds to high temperature, but many of the mechanisms driving its thermal actuation remain unclear. Its recently resolved structure has enabled a number of molecular dynamics (MD) studies focused on illuminating these mechanisms. Here we add to these efforts by performing the first all-atom MD simulations of its most recently resolved structure at different temperatures. While the complete, thermally induced transition of TRPV1 from its closed to open configuration remains elusive, our analysis of the hydrogen bonding networks, thermodynamics, hydration, and principal components of motion provide a wealth of information on the mechanisms which initiate or influence the thermal opening in TRPV1. In particular, we (i) support the previously proposed mechanism driving thermal actuation in the extracellular pore of TRPV1, (ii) present new hypotheses regarding the thermal actuation in the C-terminal and adjacent linker domains, and (iii) support and build upon the existing hypothesis regarding the role of the vanilloid binding pocket and lipids embedded therein.

59 BASIC BIOLOGICAL SCIENCES↗

Actuator selection and placement for localized feedback flow control

The selection and placement of actuators and sensors to control compressible viscous flows is addressed by developing a novel methodology based upon the eigensystem structural sensitivity of the linearized evolution operator appropriate for linear feedback control. Forward and adjoint global modes are used to construct a space of possible perturbations to the linearized operator, which yields a small optimization problem for selecting the parameters that best achieve the control objective, including where they should be placed. The method is demonstrated by informing actuation to suppress amplification of the instabilities in boundary layer separation in a high-subsonic diffuser. Complete stabilization is observed in the separated shear layer for short downstream distances at modest Reynolds number. Higher Reynolds numbers and longer distances are expected to be more challenging to stabilize; here the control informed by the procedure still substantively suppresses amplification of instabilities. It is also demonstrated that more complex actuator–sensor selections may not yield superior controllers.

Mechanics↗