Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

TR acking A erosol C onvection Interations E xpe R iment ( TRACER ): Site Selection for the ARM TRACER Campaign

Three AMF Sites are needed: Main Site for the AMF1 Observatory, an 'ancillary site' to the SW of the city for measurement of air before crossing Houston. A radar site for the CSAPR between the main and ancillary sites, ideally no more than 50km from either site. We are making preliminary evaluations of sites for tethered balloon system (TBS) activities.

54 ENVIRONMENTAL SCIENCES↗

IceCube's convex all-sky neutrino spectrum consistent with the magnetically powered corona scenario for active galactic nuclei

High-energy multimessenger background analyses over the past decade have provided evidence for a population of hidden neutrino sources that are opaque to GeV-TeV gamma rays, a picture bolstered by recent observations of the nearby active galaxy NGC 1068. The coronal regions in the hearts of active galactic nuclei (AGNs) have been proposed as the most promising sites for such hidden nonthermal particle production, and NGC 1068 is expected to be the most neutrino-active galaxy for IceCube. We demonstrate that the latest all-sky neutrino spectrum, exhibiting a spectral bend around 3-30 TeV, is consistent with predictions of the magnetically powered corona scenario, and the models for the all-sky neutrino flux can simultaneously explain the multimessenger data from NGC 1068 within observational and modeling uncertainties. We further show, in a largely model-independent way, that the contribution from NGC 1068-like sources does not overshoot the observed medium-energy neutrino flux. Finally, we highlight the key role of the Eddington ratio, which can drive substantial variations in the predicted neutrino fluxes of nearby AGNs, and we encourage systematic multimessenger searches for the neutrino-brightest AGNs.

Murase, Kohta [Penn State U.; Penn State U., Unive↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Actively cooled optical substrates for high average power reflective or diffractive optic

Integrated active cooling of high-power reflective or diffractive optics uses substrates manufactured from low-expansion ceramics to flow coolant between the back surface of the substrate and chambers behind but adjacent a reflective front surface, in a direction transverse to the front surface, to thereby achieve much greater average power handling than known cooling techniques.

Power, Erik P.↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through various methods, two of them being thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine thermal quadrant powers. The N-16 system utilizes a beta detector that outputs Nitrogen activation levels to calculate lobe power through an algorithm called Lobe Power Calculation and Indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. These correct indications are crucial for maintaining safety limits because operators rely on this information for decision making. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have increased the accuracy of power readings by making the system more dynamic. The new proposed coefficient and multiplier method implements a cycle specific and physics-based model intended for changing coefficients during operation. This calibration experiment focused on power splitting, outer shim and neck shim, as well as fuel burning into the reactor digital acquisition system (RDAS) weighting factors. Results demonstrated that the physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hard-to-soft transition-enhanced piezoelectricity in poly(vinylidene fluoride) via relaxor-like secondary crystals activated by high-power ultrasonication

We report although high piezoelectric coefficients have recently been observed in poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)] random copolymers, they have low Curie temperatures, which makes their piezoelectricity thermally unstable. It has been challenging to achieve high piezoelectric performance from the more thermally stable PVDF homopolymer. In this report, we describe how high-power ultrasonic processing was used to induce a hard-to-soft piezoelectric transition and improve the piezoelectric coefficient d 31 in neat PVDF. After high-power ultrasonication for 20 min, a uniaxially stretched and poled PVDF film exhibited a high d 31 of 50.2 ± 1.7 pm V -1 at room temperature. Upon heating to 65 °C, the d 31 increased to a maximum value of 76.2 ± 1.2 pm V -1 , and the high piezoelectric performance persisted up to 110 °C. The enhanced piezoelectricity was attributed to the relaxor-like secondary crystals in the oriented amorphous fraction, broken off from the primary crystals by ultrasonication, as suggested by differential scanning calorimetry and broadband dielectric spectroscopy studies.

relaxor-like secondary crystals↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Factor-Coupled, Ahead-of-Time Aggregation of Power Flexibility Under Forecast Uncertainty

The increasing penetration of distributed energy resources (DERs) is significantly reshaping the role of distribution systems under active energy management. To aggregate the active-reactive power flexibility of DERs dispersed at the feeder and provide capacity support to the transmission system, it is essential to efficiently identify feasible substation power injection trajectories. This paper introduces a novel ahead-of-time flexibility characterization method to address it. First, a polyhedral non-feeder-level power flexibility region (PFR) is constructed, accounting for various time-dependent, power-coupled, and forecast error uncertainties. Then, a polyhedral feeder-level PFR is analytically derived through a coordinate transformation, which can reveal the uncertainty propagation path, i.e., how uncertainty applies to the feeder-level PFR. To facilitate the high-level application, a tractable chance-constrained Chebyshev centering optimization model is further developed to find a ball-shaped inner approximation of the feeder-level PFR. Finally, the proposed method is validated on a modified IEEE 123-bus test system. Here, both theoretical and experimental results show that, with appropriate robustness parameter settings, the proposed method can make the approximated PFR less conservative with abundant robustness against forecast error uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Do Molecular Fingerprints Identify Diverse Active Drugs in Large-Scale Virtual Screening? (No)

Computational approaches for small-molecule drug discovery now regularly scale to the consideration of libraries containing billions of candidate small molecules. One promising approach to increased the speed of evaluating billion-molecule libraries is to develop succinct representations of each molecule that enable the rapid identification of molecules with similar properties. Molecular fingerprints are thought to provide a mechanism for producing such representations. Here, we explore the utility of commonly used fingerprints in the context of predicting similar molecular activity. We show that fingerprint similarity provides little discriminative power between active and inactive molecules for a target protein based on a known active—while they may sometimes provide some enrichment for active molecules in a drug screen, a screened data set will still be dominated by inactive molecules. We also demonstrate that high-similarity actives appear to share a scaffold with the query active, meaning that they could more easily be identified by structural enumeration. Furthermore, even when limited to only active molecules, fingerprint similarity values do not correlate with compound potency. In sum, these results highlight the need for a new wave of molecular representations that will improve the capacity to detect biologically active molecules based on their similarity to other such molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Control, Operation, and Stability Characteristics of Grid-Forming Type III Wind Turbines: Preprint

This paper explores the control, operation, and stability characteristics of grid-forming Type III wind turbines. The paper shows that the grid-forming operation mode requires redesign of only the slower control loops for active and reactive power control, whereas the faster current control implementation can stay the same as grid-following turbines. The paper also shows that grid-forming wind turbines face higher mechanical stress than grid-following wind turbines because of the slower speed of the active power control. This stress, however, can be mitigated using advanced pitch control. The paper compares the stability characteristics of the grid-forming and grid-following operation modes of Type III turbines by comparing sequence impedance responses for both operation modes. It is found that, unlike standard Type III wind turbines, the grid-forming mode substantially reduces the risks of subsynchronous oscillations during operation with series-compensated transmission lines. Moreover, the grid-forming Type III turbines can operate stably with extremely weak grids. The findings of this paper are validated using EMT-PSCAD simulations of a 2.5-MW turbine operating in both grid-forming and grid-following modes.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Multi-physics Preconditioning for Thermally Activated Batteries

Thermal batteries, also known as molten-salt batteries, are single-use reserve power systems activated by pyrotechnic heat generation, which transitions the solid electrolyte into a molten state. The simulation of these batteries relies on multiphysics modeling to evaluate performance and behavior under various conditions. This paper presents advancements in scalable preconditioning strategies for the Thermally Activated Battery Simulator (TABS) tool, enabling efficient solutions to the coupled electrochemical systems that dominate computational costs in thermal battery simulations. We propose a hierarchical block Gauss-Seidel preconditioner implemented through the Teko package in Trilinos, which effectively addresses the challenges posed by tightly coupled physics, including charge transport, porous flow, and species diffusion. The preconditioner leverages scalable subblock solvers, including smoothed aggregation algebraic multigrid (SA-AMG) methods and domain-decomposition techniques, to achieve robust convergence and parallel scalability. Strong and weak scaling studies demonstrate the solver’s ability to handle problem sizes up to 51.3 million degrees of freedom on 2048 processors, achieving near sub-second setup and solve times for the end-to-end electrochemical solve. These advancements significantly improve the computational efficiency and turnaround time of thermal battery simulations, paving the way for higher-resolution models and enabling the transition from 2D axisymmetric to full 3D simulations.

25 ENERGY STORAGE↗

Deep Active Learning for Solvability Prediction in Power Systems

Traditional methods for solvability region analysis can only have inner approximations with inconclusive conservatism and handle limited types of power flow models. In this letter, we propose a deep active learning framework for solvability prediction in power systems. Compared with passive learning where the training is performed after all instances are labeled, active learning selects most informative instances to be labeled and therefore significantly reduces the size of the labeled dataset for training. In the active learning framework, the acquisition functions, which correspond to different sampling strategies, are defined in terms of the on-the-fly posterior probability from the classifier. First, the IEEE 39-bus system is employed to validate the proposed framework, where a two-dimensional case is illustrated to visualize the effectiveness of the sampling method followed by the high-dimensional numerical experiments. Then, the Northeast Power Coordinating Council (NPCC) 140-bus system is used to validate the performance on large-scale power systems.

42 ENGINEERING↗

Medium Voltage Energy Hub Based on Multilevel Cascaded H Bridge-Dual Active Bridge Back-to-Back Converter for Power Distribution Feeders Interconnection and Multiple Simultaneous Grid Services

This paper presents a medium voltage energy hub based on a modular design of a multilevel cascaded H bridge (CHB)-dual active bridge (DAB) converter. The energy hub composed of the two CHB-DAB modules with a back-to-back topology can be utilized as a grid interconnection component between distribution feeders. The energy hub can provide multiple simultaneous grid services such as voltage regulation, power factor correction, as well as active power flow control between the connected feeders, contributing to grid flexibility, efficiency, reliability, and resilience. Circuit structure and control schemes for the energy hub including both local controllers for each converter and outer loop controllers are proposed to enable simultaneous grid services with coordination to prevent the overloading of the hub. To validate the performance of the hub, the hub system is interconnected between two IEEE 4-bus feeders and provides voltage regulation for both feeders, while controlling active power flow between them. The system and the feeders are implemented in Real-Time Digital Simulator (RTDS) for real-time simulation verification.