MODAQ 2.0 (Modular Ocean Data AcQuisition System v2.0) [SWR-24-138]

MODAQ 2.0 is the continuation of the Modular Ocean/Offshore Data AcQuisition system which offers new benefits of being based on generally available hardware and open-source development tools. The MODAQ 2.0 project is the amalgamation of ROS packages, tools, and guidance for developing data acquisition and control applications for marine energy devices using a ROS2 based architecture. The MODAQ 2.0 Reference Design includes several packages that are targeted for the marine energy sector and allow most developers with a basic background in programming to spin up a high-quality DAQ and control system. It is comprised of multiple software repositories which can be found at the MODAQ2 GitHub Organization: https://github.com/NREL-MODAQ2

Nichols, Casey↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

HPC Center of the Future: R&D Acquisition Intent

This document contains intended technical requirements for an anticipated future procurement for Lawrence Livermore National Laboratory (LLNL), hereafter referred to as “LLNL” or “the Laboratory”, which seeks to fund a few new and innovative proposals for developing concepts and performing studies that would lead to products available in the 2029-2030 timeframe. Our interest is to incentivize explorations and evaluations of technical capabilities in support of our vision for a High Performance Computing (HPC) center of the future at Livermore Computing (LC), the HPC center at LLNL. To realize this vision a new approach to our approach to acquisition is being considered by LC. The approach is designed to decrease risks for the vendors, while encouraging a broader set of vendors able and we hope willing to partner with LLNL and LC. The future HPC Center vision and acquisition approach was conceived to meet the future mission needs of the Advanced Simulation and Computing (ASC) Program within the National Nuclear Security Administration (NNSA).

97 MATHEMATICS AND COMPUTING↗

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

Advancing $otsdaq$ for Optimized Data Acquisition

High-energy physics (HEP) experiments demand data acquisition (DAQ) systems capable of orchestrating complex detector operations, high data throughput, and responsive, real-time feedback. Traditional systems often have steep learning curves, making onboarding difficult for new users. The Off-The-Shelf Data Acquisition $otsdaq$ framework was developed to address these issues by providing a modular and flexible interface that is easier to operate while remaining customizable enough for experimental setups. As the upcoming Mu2e experiment prepares for deployment, improving stability, usability, and performance has become increasingly critical. Our work enhances $otsdaq$ with features that streamline visualization, correct data metrics, improve debugging workflows, and stabilize the user interface.

Mohammed, Ali (ORCID:0009000860386626)↗

Acquisition of pseudonoise signals by sequential estimation

Rapid Acquisition by Sequential Estimation /RASE/ system is used in the receivers of tracking and communications systems to bring identical locally generated pseudonoise digital modulation signal into time synchronization with the incoming pseudonoise signal. This acquisition system is particularly suited for medium input signal-to-noise ratios.

Ward, R. B.↗

The application of remote sensing techniques to selected inter and intra urban data acquisition problems

The utility of remote sensing techniques to urban data acquisition problems in several distinct areas was identified. This endeavor included a comparison of remote sensing systems for urban data collection, the extraction of housing quality data from aerial photography, utilization of photographic sensors in urban transportation studies, urban change detection, space photography utilization, and an application of remote sensing techniques to the acquisition of data concerning intra-urban commercial centers. The systematic evaluation of variable extraction for urban modeling and planning at several different scales, and the model derivation for identifying and predicting economic growth and change within a regional system of cities are also studied.

Horton, F. E.↗

A Markov chain technique for determining the acquisition behavior of a digital tracking loop

An iterative procedure is presented for determining the acquisition behavior of discrete or digital implementations of a tracking loop. The technique is based on the theory of Markov chains and provides the cumulative probability of acquisition in the loop as a function of time in the presence of noise and a given set of initial condition probabilities. A digital second-order tracking loop to be used in the Viking command receiver for continuous tracking of the command subcarrier phase was analyzed using this technique, and the results agree closely with experimental data.

Chadwick, H. D.↗

Data acquisition system for operational earth observation missions

The data acquisition system capabilities expected to be available in the 1980 time period as part of operational Earth observation missions are identified. By data acquisition system is meant the sensor platform (spacecraft or aircraft), the sensors themselves and the communication system. Future capabilities and support requirements are projected for the following sensors: film camera, return beam vidicon, multispectral scanner, infrared scanner, infrared radiometer, microwave scanner, microwave radiometer, coherent side-looking radar, and scatterometer.

Deerwester, J. M.↗

Data acquisition and reduction for the University of Virginia superconducting magnetic suspension and balance facility

The problems associated with data acquisition and reduction in the U.Va. superconducting magnetic suspension and balance facility are similar to those in free-flight ranges (or tunnels). The model undergoes a Quasi-six-degree of freedom motion which must be monitored both in position and angular orientation problem is made more difficult because geometric constraints prevent direct visual access to the model in the Mach 3 wind tunnel. The methods, accuracies and problems associated with the acquisition of data are discussed.

Jacobson, I. D.↗

Automatic carrier acquisition system

An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator.

Bunce, R. C.↗

RALPH: An online computer program for acquisition and reduction of pulse height data

A background/foreground data acquisition and analysis system incorporating a high level control language was developed for acquiring both singles and dual parameter coincidence data from scintillation detectors at the Radiation Counting Laboratory at the NASA Manned Spacecraft Center in Houston, Texas. The system supports acquisition of gamma ray spectra in a 256 x 256 coincidence matrix (utilizing disk storage) and simultaneous operation of any of several background support and data analysis functions. In addition to special instruments and interfaces, the hardware consists of a PDP-9 with 24K core memory, 256K words of disk storage, and Dectape and Magtape bulk storage.

Davies, R. C.↗

Development of AIFTDS-4000, a flight-qualified, flexible, high-speed data acquisition system

The NASA flight research center has developed a prototype data acquisition system which integrates an airborne computer with a high-speed pulse code modulation system. The design of the airborne integrated flight test data system (AIFTDS) is the result of experience with airborne pulse code modulation data systems. The AIFTDS-4000 has proved the premise on which it was designed: that the needs and requirements of data acquisition system users can be integrated to produce a highly flexible system that will be more useful than existing systems.

Borek, R. W.↗

Station Data Acquisition and Control System.

The Station Data Acquisition and Control System (STADAC), a multicomputer data handling and control system, is expected to be installed in six network stations, the first station to be established at Goddard Space Flight Center. Network control data, in the form of schedules and acquisition pointing data, flow from the Network Control Center to the stations, while station status data flow in the other direction. The system will format spacecraft telemetry data for real-time transmission of control and status data to the project operations control centers and for transmission of experiment data to the data processing facilities. The system will also schedule station equipment resources, perform prepass tests to assure data quality, and automatically set up selected station equipment.

Kiebler, J. W.↗

Target Acquisition and Positioning Study (TAPS)

The Scientific Instruments for the Large Space Telescope (LST) require a high degree of accuracy for positioning targets within their respective entrance apertures. The acquisition, verification of position, and guidance during an experiment must be accomplished with a minimum loss of observing time for the maximum effectiveness of the total mission. This study evaluates several viable concepts and modes of operation that are applicable for a Target Acquisition and Positioning System (TAPS) that is responsive to the LST instrument requirements.

Source record↗

Study and design of cryogenic propellant acquisition systems. Volume 1: Design studies

An in-depth study and selection of practical propellant surface tension acquisition system designs for two specific future cryogenic space vehicles, an advanced cryogenic space shuttle auxiliary propulsion system and an advanced space propulsion module is reported. A supporting laboratory scale experimental program was also conducted to provide design information critical to concept finalization and selection. Designs using localized pressure isolated surface tension screen devices were selected for each application and preliminary designs were generated. Based on these designs, large scale acquisition prototype hardware was designed and fabricated to be compatible with available NASA-MSFC feed system hardware.

Burge, G. W.↗