Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting that no further leaks of the SM air conditioner have occurred.

James, John T.↗

NASTRAN Benefits Analysis. Volume 1: Executive Summary

The acceptance of NASTRAN, the NASA structural analysis computer program, is explored, based on data from a sample set of users. Baseline data are generated for future comparison of costs and benefits of the program. The impact on, and benefits to, segments of government and industry from current use of NASTRAN are considered. Ways in which potential users may benefit from application of the program to their individual needs are also discussed.

Source record↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

Appetite and Food Intake During 11 Days of Mild Hypobaric Hypoxia

Introduction Reduced food consumption and loss of body mass and muscle mass have been observed during spaceflight. Hypoxic conditions that astronauts may encounter on exploration missions may further implicate satiety signals and dietary intake. Appetite, food intake, and satiety hormones were investigated under the conditions of mild hypoxia and high energy output during simulated extravehicular activity (EVA) to determine the adequacy of a mission relevant space food system to support energy balance and body composition. Methods Foods realistic to early Artemis missions was packed by meal for each subject for the 11-day test based on estimated energy requirements (EER) and estimated EVA caloric requirements. No hot water or food warmer was provided and only room temperature water was available to rehydrate food and beverages in-mission, mimicking plans for early Artemis missions. Measures included food records (pre-mission, in-mission); fasted body weight (pre-mission, in-mission); Dual-energy X-ray absorptiometry (DXA) (pre-mission, post-mission); subjective ratings and feedback of food acceptability, mealtime and meal preparation sufficiency, appetite, and nausea (in-mission); and circulating ghrelin and leptin concentration in fasted blood samples (pre-mission, in-mission: pre-post EVA). Results All subjects consumed fewer calories in-mission than predicted. On average, subjects consumed 341 calories less on EVA days compared to non-EVA days in-mission (p=0.0511). The total weight loss estimate from daily weight measurements (-1.1 kg, p=0.0028) is consistent with underconsumption and supported by DXA measurements (-1.3 kg total body mass, p=0.0123 and -1.6 kg fat mass, p=0.0016). In general, most foods that were consumed were given acceptable scores, but subject comments indicated that the most acceptable foods were those not intended to be heated. Comments also indicated that subjects found their favorite foods early in the mission and avoided the foods that they did not like throughout the mission. Habitability scores indicated that overall aspects of the food system were considered borderline or unacceptable over the length of this mission. Foods that caused gas were avoided pre-EVA to prevent discomfort during pressure changes. Average fruit and vegetable intake decreased during the mission, dropping from 4.8 servings/d pre-mission to 3.4 servings/d on non-EVA days in-mission (p=0.0872) and 2.3 servings on EVA days (p=0.0020). Fasting ghrelin concentrations tended to be lower pre-EVA and on non-EVA days when exposed to mild hypoxia compared to normoxic conditions pre-mission and post-EVA (p=0.0136). Fasting levels of leptin did not change. Discussion Food intake was reduced in-mission, resulting in a caloric deficit and weight loss for most subjects. Crew food and appetite ratings and comments indicated this was due to a combination of food choices, lack of preference, lack of preparation capability, lack of time for meal preparation, consumption, and cleanup, and physiological challenges with the changing pressure. The regulation of appetite stimulating hormone ghrelin, but not the appetite suppressor leptin, appeared to be sensitive to hypoxic conditions. Conclusions Food preparation capabilities and time for meals are important for promoting adequate food intake. Reduced appetite and food intake during missions may further be aggravated under hypoxic conditions through the suppression of ghrelin. Lack of time for meals on EVA days, and avoidance of potential gas-causing foods (e.g., health promoting fruits and vegetables) prior to EVAs, demonstrate the importance of scheduling ample recovery time between EVA days.

Grace L Douglas↗

Appetite and Food Intake During 11 Days of Mild Hypobaric Hypoxia

Introduction Reduced food consumption and loss of body mass and muscle mass have been observed during spaceflight. Hypoxic conditions that astronauts may encounter on exploration missions may further implicate satiety signals and dietary intake. Appetite, food intake, and satiety hormones were investigated under the conditions of mild hypoxia and high energy output during simulated extravehicular activity (EVA) to determine the adequacy of a mission relevant space food system to support energy balance and body composition. Methods Foods realistic to early Artemis missions was packed by meal for each subject for the 11-day test based on estimated energy requirements (EER) and estimated EVA caloric requirements. No hot water or food warmer was provided and only room temperature water was available to rehydrate food and beverages in-mission, mimicking plans for early Artemis missions. Measures included food records (pre-mission, in-mission); fasted body weight (pre-mission, in-mission); Dual-energy X-ray absorptiometry (DXA) (pre-mission, post-mission); subjective ratings and feedback of food acceptability, mealtime and meal preparation sufficiency, appetite, and nausea (in-mission); and circulating ghrelin and leptin concentration in fasted blood samples (pre-mission, in-mission: pre-post EVA). Results All subjects consumed fewer calories in-mission than predicted. On average, subjects consumed 341 calories less on EVA days compared to non-EVA days in-mission (p=0.0511). The total weight loss estimate from daily weight measurements (-1.1 kg, p=0.0028) is consistent with underconsumption and supported by DXA measurements (-1.3 kg total body mass, p=0.0123 and -1.6 kg fat mass, p=0.0016). In general, most foods that were consumed were given acceptable scores, but subject comments indicated that the most acceptable foods were those not intended to be heated. Comments also indicated that subjects found their favorite foods early in the mission and avoided the foods that they did not like throughout the mission. Habitability scores indicated that overall aspects of the food system were considered borderline or unacceptable over the length of this mission. Foods that caused gas were avoided pre-EVA to prevent discomfort during pressure changes. Average fruit and vegetable intake decreased during the mission, dropping from 4.8 servings/d pre-mission to 3.4 servings/d on non-EVA days in-mission (p=0.0872) and 2.3 servings on EVA days (p=0.0020). Fasting ghrelin concentrations tended to be lower pre-EVA and on non-EVA days when exposed to mild hypoxia compared to normoxic conditions pre-mission and post-EVA (p=0.0136). Fasting levels of leptin did not change. Discussion Food intake was reduced in-mission, resulting in a caloric deficit and weight loss for most subjects. Crew food and appetite ratings and comments indicated this was due to a combination of food choices, lack of preference, lack of preparation capability, lack of time for meal preparation, consumption, and cleanup, and physiological challenges with the changing pressure. The regulation of appetite stimulating hormone ghrelin, but not the appetite suppressor leptin, appeared to be sensitive to hypoxic conditions. Conclusions Food preparation capabilities and time for meals are important for promoting adequate food intake. Reduced appetite and food intake during missions may further be aggravated under hypoxic conditions through the suppression of ghrelin. Lack of time for meals on EVA days, and avoidance of potential gas-causing foods (e.g., health promoting fruits and vegetables) prior to EVAs, demonstrate the importance of scheduling ample recovery time between EVA days.

Lichar Dillon↗

Automated array assembly, phase 2

Tasks of scaling up the tandem junction cell (TJC) from 2 cm x 2 cm to 6.2 cm and the assembly of several modules using these large area TJC's are described. The scale-up of the TJC was based on using the existing process and doing the necessary design activities to increase the cell area to an acceptably large area. The design was carried out using available device models. The design was verified and sample large area TJCs were fabricated. Mechanical and process problems occurred causing a schedule slippage that resulted in contract expiration before enough large-area TJCs were fabricated to populate the sample tandem junction modules (TJM). A TJM design was carried out in which the module interconnects served to augment the current collecting buses on the cell. No sample TJMs were assembled due to a shortage of large-area TJCs.

Carbajal, B. G.↗

Producing chondrules by recycling and volatile loss

Interelement correlations observed in bulk chondrule INAA data, particularly between the refractory lithophiles, have led to the now generally accepted conclusion that the chondrule precursors were nebular condensates. However, it has been recently suggested that random sampling of fragments from a previous generation of chondrules could reproduce much of the observed range of bulk chondrule composition.

Alexander, C. M. O.↗

ISS Expeditions 16 Thru 20: Chemical Analysis Results for Potable Water

This slide presentation reviews the results of the chemical analysis of the potable water supply from the International Space Station (ISS) expeditions 16 thru 20. Both Russian ground water and shuttle-transferred water are available for the use of the ISS crew's requirements. This is supplemented with condensate water and water form the Water Recovery System (WRS). An overview of the condensate H2O recovery system is given and the WRS is described and diagrammed. The water quality requirements, the handling, and analytical methods for the inorganic and organic tests are reviewed. The chemical analysis results for expeditions 16-20 archival water samples collected from the various water sources indicate that all of the ISS potable water supplies were acceptable for crew consumption.

Straub, John E., II↗

STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas after the repair the levels were near 0.04 mg/m3 . This does not mean that local sources in the Lab have been reduced, only that the excess of formaldehyde produced in the Lab is distributed into the whole volume of the ISS.

James, John T.↗

Service Life Extension of the Propulsion System of Long-Term Manned Orbital Stations

One of the critical non-replaceable systems of a long-term manned orbital station is the propulsion system. Since the propulsion system operates beginning with the launch of station elements into orbit, its service life determines the service life of the station overall. Weighing almost a million pounds, the International Space Station (ISS) is about four times as large as the Russian space station Mir and about five times as large as the U.S. Skylab. Constructed over a span of more than a decade with the help of over 100 space flights, elements and modules of the ISS provide more research space than any spacecraft ever built. Originally envisaged for a service life of fifteen years, this Earth orbiting laboratory has been in orbit since 1998. Some elements that have been launched later in the assembly sequence were not yet built when the first elements were placed in orbit. Hence, some of the early modules that were launched at the inception of the program were already nearing the end of their design life when the ISS was finally ready and operational. To maximize the return on global investments on ISS, it is essential for the valuable research on ISS to continue as long as the station can be sustained safely in orbit. This paper describes the work performed to extend the service life of the ISS propulsion system. A system comprises of many components with varying failure rates. Reliability of a system is the probability that it will perform its intended function under encountered operating conditions, for a specified period of time. As we are interested in finding out how reliable a system would be in the future, reliability expressed as a function of time provides valuable insight. In a hypothetical bathtub shaped failure rate curve, the failure rate, defined as the number of failures per unit time that a currently healthy component will suffer in a given future time interval, decreases during infant-mortality period, stays nearly constant during the service life and increases at the end when the design service life ends and wear-out phase begins. However, the component failure rates do not remain constant over the entire cycle life. The failure rate depends on various factors such as design complexity, current age of the component, operating conditions, severity of environmental stress factors, etc. Development, qualification and acceptance test processes provide rigorous screening of components to weed out imperfections that might otherwise cause infant mortality failures. If sufficient samples are tested to failure, the failure time versus failure quantity can be analyzed statistically to develop a failure probability distribution function (PDF), a statistical model of the probability of failure versus time. Driven by cost and schedule constraints however, spacecraft components are generally not tested in large numbers. Uncertainties in failure rate and remaining life estimates increase when fewer units are tested. To account for this, spacecraft operators prefer to limit useful operations to a period shorter than the maximum demonstrated service life of the weakest component. Running each component to its failure to determine the maximum possible service life of a system can become overly expensive and impractical. Spacecraft operators therefore, specify the required service life and an acceptable factor of safety (FOS). The designers use these requirements to limit the life test duration. Midway through the design life, when benefits justify additional investments, supplementary life test may be performed to demonstrate the capability to safely extend the service life of the system. An innovative approach is required to evaluate the entire system, without having to go through an elaborate test program of propulsion system elements. Evaluating every component through a brute force test program would be a cost prohibitive and time consuming endeavor. ISS propulsion system components were designed and built decades ago. There are no representative ground test articles for some of the components. A 'test everything' approach would require manufacturing new test articles. The paper outlines some of the techniques used for selective testing, by way of cherry picking candidate components based on failure mode effects analysis, system level impacts, hazard analysis, etc. The type of testing required for extending the service life depends on the design and criticality of the component, failure modes and failure mechanisms, life cycle margin provided by the original certification, operational and environmental stresses encountered, etc. When specific failure mechanism being considered and the underlying relationship of that mode to the stresses provided in the test can be correlated by supporting analysis, time and effort required for conducting life extension testing can be significantly reduced. Exposure to corrosive propellants over long periods of time, for instance, lead to specific failure mechanisms in several components used in the propulsion system. Using Arrhenius model, which is tied to chemically dependent failure mechanisms such as corrosion or chemical reactions, it is possible to subject carefully selected test articles to accelerated life test. Arrhenius model reflects the proportional relationship between time to failure of a component and the exponential of the inverse of absolute temperature acting on the component. The acceleration factor is used to perform tests at higher stresses that allow direct correlation between the times to failure at a high test temperature to the temperatures to be expected in actual use. As long as the temperatures are such that new failure mechanisms are not introduced, this becomes a very useful method for testing to failure a relatively small sample of items for a much shorter amount of time. In this article, based on the example of the propulsion system of the first ISS module Zarya, theoretical approaches and practical activities of extending the service life of the propulsion system are reviewed with the goal of determining the maximum duration of its safe operation.

Kamath, Ulhas↗

How Usability Testing Resulted in Improvements to Ground Collision Software for General Aviation: Improved Ground Collision Avoidance System (IGCAS)

The NASA improved Ground Collision Avoidance System (iGCAS) team conducted an onsite usability study at Experimental Aircraft Association (EAA) Air Venture in Oshkosh, Wisconsin from July 19 through July 26, 2015. EAA Air Venture had approximately 550,000 attendees from which the sample pool of pilots were selected. The objectives of this study were to assess the overall appropriateness and acceptability of iGCAS as a warning system for General Aviation aircraft, usability of the iGCAS displays and audio cues, test terrain avoidance characteristics, performance, functionality, pilot response time, and correlate terrain avoidance performance and pilot response time data.

collision avoidance↗

Determination of liquid-phase immiscibility in the lead-zinc system

A number of different techniques in the past have yielded inconsistent equilibrium measurements of immiscibility in the Pb-Zn system above 600 C. Accurate differential thermal analysis (DTA) measurements were performed on well-homogenized samples of high-purity Pb-Zn, and they indicate that the immiscibility curve is higher than previously accepted for Zn compositions between 20 and 70 at. %. The maximum deviations observed correspond to about 20 C. Below 600 C the DTA results agree with previous results.

Trahan, J. F.↗

Fatigue behavior of flexhoses and bellows due to flow-induced vibrations

The analysis and results developed in a fresh approach to calculate flow induced vibration response of a flexible flow passage are summarized. The vibration results are further examined in the frequency domain to obtain dominant frequency information. A cumulative damage analysis due to cyclic strains is performed to obtain the number of cycles to failure for a metallic bellows of particular specifications under a variety of operational conditions. Sample plots of time and frequency domain responses are included. The complex listing of a computer program is provided. The program successively executes each of the analyses needed to calculate the vibration response, the frequency response, the cyclic strains and the number of cycles to failure. The program prompts the user for necessary input information. Sample data from the program is provided. The fatigue life results obtained by the computer model lie within an acceptable range of previously measured available data.

Desai, P. V.↗

Contamination control approach for the Extreme Ultraviolet Explorer satellite instrumentation

The Extreme Ultraviolet Explorer will perform an all-sky survey and spectroscopic observations over the wavelength range 80-900A. Hydrocarbon and particulate contamination will potentially affect the throughput and signal to noise ratio of the signal detected by the instruments. A witness sample program is here used to investigate and monitor the effects of specific contaminants on EUV reflectivity. Witness samples were intentionally contaminated with thin layers of pump oil. An oil layer 150 A thick was applied and found to evaporate over 8 hours. The EUV reflectivity and imaging properties were then measured and found to be acceptable for grazing angles between 5 and 30 deg. In a second test, layers 500 A thick were deposited and then allowed to evaporate in vacuum; once the oil had evaporated to at least 350 A, the final sample reflectivity was degraded less than 10 percent, but the image was degraded severely by scattering. An outline of the contamination control program is also presented.

Mrowka, Stan↗

Report on the international Cambodian crater expedition, 1992

It has been proposed that Tonle Sap, a lake in Cambodia, 100 km long and 30 km wide, marks the location of an elongate basin formed by the oblique impact of a comet or asteroid. The impact is considered to have produced melted ejecta found now as tektites over much of southeast Asia and Australia. The location of the lake, its approximate age, its size, and the orientation of its long axis (toward Australia) are consistent with this hypothesis. Our scientific objectives were to find impact or shock metamorphosed rocks unambiguously related to the Tonle Sap basin, to collect samples of rocks that may represent those melted to produce Australasian tektites, and to learn as much as possible about Cambodian geology. Using 1:200,000-scale geologic maps with fairly detailed descriptions of the rock units, we selected a number of acceptable 'phnoms' (hills that rise abruptly out of the surrounding plain) that may contain rocks affected by the postulated Tonle Sap impact. A map of central Cambodia is shown, and the locations of sites where samples were collected are indicated. A list of those sites, together with a description of the rocks reported to be present at each site, is given. No obviously shock-metamorphosed or suevite-like rocks were observed. Recent alluvium surrounding Tonle Sap is judged to be lake sediment deposited when the lake surface was at a higher elevation.

Hartung, J.↗

2014 ISS Potable Water Characterization and Continuation of the DMSD Chronicle

During 2014 the crews from Expeditions 38-41 were resident on the International Space Station (ISS). In addition to the U.S. potable water reclaimed from humidity condensate and urine, the other water supplies available for their use were Russian potable water reclaimed from condensate and Russian ground-supplied potable water. Beginning in June of 2014, and for the fourth time since 2010, the product water from the U.S. Water Processor Assembly (WPA) experienced a rise in the total organic carbon (TOC) level due to organic contaminants breaking through the water treatment process. Results from ground analyses of ISS archival water samples returned on Soyuz 38 confirmed that dimethylsilanediol (DMSD) was once again the contaminant responsible for the rise. With this confirmation in hand and based upon the low toxicity of DMSD, a waiver was approved to allow the crew to continue to consume the water after the TOC level exceeded the U.S. Segment limit of 3 mg/L. Several weeks after the WPA multifiltration beds were replaced, as anticipated based upon experience from previous rises, the TOC levels returned to below the method detection limit of the onboard TOC analyzer (TOCA). This paper presents and discusses the chemical analysis results for the ISS archival potable water samples returned in 2014 and analyzed by the Johnson Space Center's Toxicology and Environmental Chemistry laboratory. These results showed compliance with ISS potable water quality standards and indicated that the potable water supplies were acceptable for crew consumption. Although DMSD levels were at times elevated they remained well below the 35 mg/L health limit, so continued consumption of the U.S potable water was considered a low risk to crew health and safety. Excellent agreement between inflight and archival sample TOC data confirmed that the TOCA performed optimally and it continued to serve as a vital tool for monitoring organic breakthrough and planning remediation action.

Straub, John E., II↗

Meal Replacement Mass Reduction Integration and Acceptability Study

The Orion Multi-Purpose Crew Vehicle (MPCV) and future exploration missions are mass constrained; therefore we are challenged to reduce the mass of the food system by 10% while maintaining safety, nutrition, and acceptability to support crew health and performance for exploration missions. Meal replacement with nutritionally balanced, 700-900 calorie bars was identified as a method to reduce mass. However, commercially available products do not meet the requirements for a meal replacement in the spaceflight food system. The purpose of this task was to develop a variety of nutritionally balanced, high quality, breakfast replacement bars, which enable a 10% food mass savings. To date, six nutrient-dense meal replacement bars have been developed, all of which meet spaceflight nutritional, microbiological, sensory, and shelf-life requirements. The four highest scoring bars were evaluated based on final product sensory acceptability, nutritional stability, qualitative stability of analytical measurements (i.e. color and texture), and microbiological compliance over a period of two years to predict long-term acceptability. All bars maintained overall acceptability throughout the first year of storage, despite minor changes in color and texture. However, added vitamins C, B1, and B9 degraded rapidly in fortified samples of Banana Nut bars, indicating the need for additional development. In addition to shelf-life testing, four bar varieties were evaluated in the Human Exploration Research Analog (HERA), campaign 3, to assess the frequency with which actual meal replacement options may be implemented, based on impact to satiety and psychosocial measurements. Crewmembers (n=16) were asked to consume meal replacement bars every day for the first fifteen days of the mission and every three days for the second half of the mission. Daily surveys assessed the crew's responses to bar acceptability, mood, food fatigue and perceived stress. Preliminary results indicate that the majority of crew members were noncompliant with daily meal replacement during the first half of the mission. Several crew members chose to forgo the meal, resulting in caloric deficits that were higher on skipped-bar days. Body mass loss was significant throughout the mission. Although there was no significant difference in body mass loss overall between the first half and second half of the mission, a higher number of individual crew members lost more body mass in the first half of the mission. Analysis is still ongoing, but current trends suggest that daily involuntary meal replacement can lead to greater individual impacts on body mass and psychological factors, while meal replacement on a more limited basis may be acceptable to most crew for missions up to 30 days. This data should be considered in Orion mass trades with health and human performance.

Sirmons, T.↗

The rotation of small asteroids

The Binzel and Mulholland (1983) sample of photoelectrically determined rotational parameters for 17 main belt asteroids with diameters less than 30 km are compared with previous observations of asteroids of that size range. Rigorous statistical tests are applied to investigate bias effects and quantify results on asteroid rotation. The samples are described and compared for rotational frequency, rotational amplitude, frequency distribution, and diameter and frequency dependence. It is concluded that the observed rotational frequency distribution can be acceptably fit by two Maxwellian distributions, which is consistent with the hypothesis that there are separate populations of slow and fast rotating asteroids. The frequency distributions of main belt asteroids less than 15 km in diameter and earth and Mars crossers do not differ significantly, but the larger mean lightcurve amplitude of these crossers is statistically significant. No significant diameter dependence on rotational frequency is found among the sample asteroids.

Binzel, R. P.↗