At least 163 records · Page 9

Proposed Test of the Two Beam BPM at RHIC

The essence of the ERL operation implies that at least two beams (accelerated and decelerated) are co-propagating in the same vacuum vessel and each beam has its own trajectory. The existing beam position monitors measure only “average” trajectory but not that of an individual beam, unless the time separation between bunches is so large that one can resolve individual bunches. It was proposed to use phase information of the pick-up signal to extract information on the orbit “difference”. We are planning to conduct experiments at RHIC to test the proposed idea. The approach and experiment set-up are described in the paper.

43 PARTICLE ACCELERATORS↗

A smart alarm for particle accelerator beamline operations

We present the initial results of a proof-of-concept 'smart alarm' for the Continuous Electron Beam Accelerator Facility injector beamline at Jefferson Lab. To minimize machine downtime and improve operational efficiency, an autonomous alarm system able to identify and diagnose unusual machine states is needed. Our approach leverages a trained neural network capable of alerting operators (a) when an anomalous condition exists in the beamline and (b) identifying the element setting that is the root cause. The tool is based on an inverse model that maps beamline readings (diagnostic readbacks) to settings (beamline attributes operators can modify). The model takes as input readings from the machine and computes machine settings which are compared to control setpoints. Instances where predictions differ from setpoints by a user-defined threshold are flagged as anomalous. Given data corresponding to 354 anomalous injector configurations, the model can narrow the root cause of an anomalous condition to three potential candidates with 94.6% accuracy. Furthermore, compared to the current method of identifying anomalous conditions which raises an alarm when machine parameters drift outside their normal tolerances, the data-driven model can identify 83% more anomalous conditions.

43 PARTICLE ACCELERATORS↗

First Results from a Nb3Sn-Coated 1.5-Cell 650 MHz SRF Cavity for Cryogen-Free Industrial Accelerators

First Results from a Nb3Sn-Coated 1.5-Cell 650 MHz SRF Cavity for Cryogen-Free Industrial Accelerators ABSTRACT = Fermilab is advancing the development of a compact, high-power electron beam accelerator using superconducting radio frequency (SRF) technology as a non-radioactive alternative to traditional radiological sources. The current design targets continuous-wave (CW) operation at \SI{1.6}{MeV} and \SI{20}{kW}. To ensure suitability for industrial environments, the system is being designed for cryogen-free operation, driving the adoption of a novel Nb$_3$Sn-coated 1.5-cell SRF cavity operating at \SI{650}{MHz}. This contribution reports on the fabrication, surface preparation, and Nb$_3$Sn coating process of the cavity, as well as first results from vertical test stand (VTS) measurements performed in a liquid helium bath. These initial tests mark a key milestone toward demonstrating the viability of conduction-cooled Nb$_3$Sn SRF cavities for industrial-scale deployment.

Tagdulang, N. [Fermilab]↗

Graph Embeddings for CEBAF Operations: Progress and Future Plans

We describe research towards leveraging deep learning on graph representations of the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF) in order to create a tool for improving the efficiency of beam tuning tasks. Specifically, we use graphs to represent the injector beamline at any arbitrary date and time and invoke a graph neural network to extract a low-dimensional, informative representation that can be visualized in two-dimensions. By analyzing years of operational data from the CEBAF archiver, good and bad regions of parameter space can be identified. The goal is to exercise this framework as a real-time tool to aid beam tuning, which represents the dominant source of machine downtime.

Tennant, C.↗

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics↗

Current status of the electron transport line from RCS to ESR: RTE line

The electron injection system of the U.S. Electron-Ion Collider (EIC) is located outside of the RHIC tunnel. Electrons beams accelerated by the Rapid Cycling Synchrotron (RCS) must be transported to the Electron Storage Ring (ESR), which resides within the RHIC tunnel. To accomplish this, a dedicated beam transport line, referred to as RTE (RCS-to-ESR) line is being designed. The proposed conceptual design comprises three main sections; RCS extraction, a vertical bend and dispersion suppression region, and ESR injection matching. The extraction section uses pulsed kickers and septum magnets to achieve a total deflection angle of 3 degrees. To align the injection section with ESR, the beamline must provide a vertical elevation of 1.68 m, and an array of FODO cells is used to suppress the vertical dispersion. The total length of the RTE line is approximately 133 m, and this paper presents the current design status and considerations for this transport line.

Accelerator Physics↗

Synthesis and characterization of electron beam irradiation-induced damage in polycrystalline metal thin films

High-energy physics research, industrial sterilizing, and material processing depend extensively on electron beam accelerators. Exit windows are crucial components of such electron accelerator systems, maintaining vacuum integrity inside the machine while providing mechanical strength, thermal stability, and radiation resistance at the beam-target interface. In this study, thin metallic films of Ni, Ti, Cr, and V were explored for use in electron beam exit windows, and their properties were compared with the properties of their bulk counterparts. Simulation results of metal foils predicted Ti to exhibit less beam power dissipation compared to Ni. However, Ni possesses superior mechanical and structural properties compared to Ti. The performance of these films under electron beam irradiation was examined by depositing thin layers of these films on silicon and metallic substrates using magnetron sputtering and exposing them to e-beam irradiation in a controlled setup. The deposited films were subjected to a dose of approximately 66 kGy at a beam energy of 10 MeV and characterized prior to and postexposure to the beam using field emission scanning electron microscopy, atomic force microscopy, x-ray diffraction (XRD), and nanoindentation. Particular emphasis was given to characteristics like the grain structure, surface morphology, dislocation density, and hardness. XRD patterns revealed irradiation-induced changes in peak intensities, while the crystallinity remained largely unchanged. Nanoindentation results showed that the pristine and irradiated Ti and Ni films were twice as hard when compared to bulk Ti and Ni samples, regardless of the substrate type used (Si or bulk Ti, or Ni). These results emphasize the superior mechanical properties of thin metal films compared to their bulk counterparts. In conclusion, this study advances the optimization of thin film materials for robust and efficient e-beam applications, ensuring improved durability and operational reliability.

AFM↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Evaluation of the first version of the new RFPI system dedicated to PIP-II project accelerator

The Low-Level Radio Frequency (LLRF) control system is one of the most critical superconducting linac infrastructures responsible for the parameters of the beam acceleration. The LLRF system mainly focuses on the electromagnetic field parameters inside the cavity. While it incorporates fast feedback algorithms to optimize energy transfer to the passing particle beam it does not follow other cryomodule or cavity parameter changes. The Radio Frequency Protection Interlock (RFPI) system closely monitors various factors (like cryomodule vacuum, beamline vacuum, field emission probe current level, temperature, RF signal leakage, etc). Its simple but reliable logic has to provide an instant decision about the LLRF system or high-power amplifier output signal blocking in case of safety region excitation. This contribution presents a new version of the RFPI system which logic is implemented in the FPGA chip. The initial work on the prototype of the new system design resulted in the PoC (Proof of Concept) device. The PoC offers the possibility of various protection logic configurations, input signals parameters evaluation, and modularity aspects verification. The structure and test results from the device evaluation are summarized and discussed in this contribution.

43 PARTICLE ACCELERATORS↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. A Principal Component Analysis (PCA) approach is being developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and PCA model, along with initial performance metrics. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Carpenter, A.↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. A Principal Component Analysis (PCA) approach is being developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and PCA model, along with initial performance metrics. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Carpenter, A.↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Selection of Target Thickness and Size of Drive Electron Beam for Ce+BAF Injector

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130-370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The positron yield and longitudinal polarization are calculated for the 123 MeV Ce+BAF injector at the Low Energy Recirculator Facility (LERF). The longitudinal and transverse CEBAF acceptances, defined as an energy spread of less than 1% and a normalized emittance of less than 100 mm·mrad, have been used in these calculations. The impact of target thickness, transverse electron beam size, and electron beam energy on the yield and polarization of a positron injector is evaluated. The total energy deposited by the beams in the tungsten target and the peak energy density are calculated for different target thicknesses, electron beam sizes, and energies.

Ushakov, Andriy [Thomas Jefferson National Acceler↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

Facility upgrade for superheavy-element research at RIKEN

The RIKEN Nishina Center (RNC) executed an accelerator upgrade project for the heavy-ion linac (called RILAC). A superconducting RIKEN linear accelerator (SRILAC) and a new superconducting electron-cyclotron-resonance ion source (SC-ECRIS) to boost the final energy and intensity were constructed, aimed at synthesizing a new superheavy element, 119, through a hot fusion reaction. The project included the construction of a gas-filled recoil ion separator (GARIS-III) suitable for detecting the residues of the hot-fusion reaction. To avoid research interruption during the SRILAC construction period (2017–2019) and gain experience in hot-fusion reaction processes, GARIS-II located in the GARIS experimental hall in LINAC building was moved to the E6 experimental hall in Nishina building. Certain exploratory measurements were performed employing the beams accelerated by RILAC2 and the RIKEN ring cyclotron (RRC), which is a part of the existing accelerator complex of the radioactive isotope beam factory (RIBF). Further, commissioning experiments with the upgraded facility (SRILAC and GARIS-III) were performed. The upgrade project and its commissioning results are chronologically described in this article.

43 PARTICLE ACCELERATORS↗

Beam study on low dispersion CEBAF arcs

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab employs recirculating linac SRF technology to generate a high polarization 12 GeV electron beam for nuclear physics users. New opportunities to study multipass energy recovery have also emerged with the proposal of a 5-pass energy recovery demonstration, ER@CEBAF. New beam optics with minimized beta functions have been developed and tested to avoid collective beam instabilities for multi-pass beams and meet the beam requirements of the nuclear physics community. To enable energy recovery for a common arc beam transport of five passes, achromatic and isochronous arc optics conditions were satisfied by re-designing the transverse optics of CEBAF. This paper focuses on beam studies conducted to study the newly-designed, low-dispersion, lowest energy arcs for CEBAF operations and ER@CEBAF.

Neththikumara, I.↗

Is Mini Beam Ready for Human Trials? Results of Randomized Study of Treating De-Novo Brain Tumors in Canines Using Linear Accelerator Generated Mini Beams

The main challenge in treating malignant brain neoplasms lies in eradicating the tumor while minimizing treatmentrelated damage. Conventional radiation treatments are associated with considerable side effects. Synchrotron generated micro-beam radiation (SMBRT) has shown to preserve brain architecture while killing tumor cells, however physical characteristics and limited facility access restrict its use. We have created a new clinical device which produces mini beams on a linear accelerator, to provide a new type of treatment called mini-beam radiation therapy (MBRT). The objective of this study is to compare the treatment outcomes of linear accelerator based MBRT versus standard radiation treatment (SRT), to evaluate the tumor response and the treatment-related changes in the normal brain with respect to each treatment type. Pet dogs with de-novo brain tumors were accrued for treatment. Dogs were randomized between standard fractionated stereotactic (9 Gy in 3 fractions) radiation treatment vs. a single fraction of MBRT (26 Gy mean dose). Dogs were monitored after treatment for clinical assessment and imaging. When the dogs were euthanized, a veterinary pathologist assessed the radiation changes and tumor response. We accrued 16 dogs, 8 dogs in each treatment arm. In the MBRT arm, 71% dogs achieved complete pathological remission. The radiation-related changes were all confined to the target region. Structural damage was not observed in the beam path outside of the target region. In contrast, none of the dogs in control group achieved remission and the treatment related damage was more extensive. Therapeutic superiority was observed with MBRT, including both tumor control and the normal structural preservation. The MBRT findings are suggestive of an immune related mechanism which is absent in standard treatment. These findings together with the widespread availability of clinical linear accelerators make MBRT a promising research topic to explore further treatment and clinical trial opportunities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards large phase space beams at the CEBAF injector

We report on the status of a degrader device to generate large phase space beams for machine acceptance studies in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The degrader device consists of thin, low-Z targets to degrade the electron beam phase space through multiple scattering, two apertures to define the maximum transverse emittance, and a solenoid to aid in matching to the rest of the injector beamline. The engineering design of the degrader device and projected degraded beam phase space parameters are presented.

Sy, A.↗