Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Xe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Rates of Earth degassing

The degassing of the Earth during accretion is constrained by Pu-U-I-Xe systematics. Degassing was much more efficient during the first 100-200 Ma than subsequently, and it was more complete for Xe than for the lighter gases. More than 90 percent of the degassed Xe escaped from the atmosphere during this period. The combination of fractional degassing of melts and rare gas escape from the atmosphere is able to explain the deficit of terrestrial Xe as a simple consequence of this early degassing history. By the time Xe was quantitatively retained in the atmosphere, the abundances of Kr and the lighter gases in the Earth's interior were similar to or higher than the present-day atmospheric abundances. Subsequent transfer of these lighter rare gases into the atmosphere requires a high rate of post-accretion degassing and melt production. Considerations of Pu-U-Xe systematics suggest that relatively rapid post-accretion degassing was continued to ca. 4.1-4.2 Ga. The present-day degassing history of the Earth is investigated through consideration of rare gas isotope abundances. Although the Earth is a highly degassed body, depleted in rare gases by many orders of magnitude relative to their solar abundances, it is at the present-day losing primordial rare gases which were trapped at the time of accretion.

Onions, R. K.↗

Low-Pressure Long-Term Xenon Storage for Electric Propulsion

This Phase 2 effort demonstrated an alternative Xe storage and regulation system using activated carbon (AC) as a secondary storage media (ACSFR). This regulator system is nonmechanical, simple, inexpensive, and lighter. The ACSFR system isolates the thruster from the compressed gas tank, and allows independent multiple setpoint thruster operation. The flow using an ACSFR can also be throttled by applying increments in electrical power. Primary storage of Xe by AC is not superior to compressed gas storage with regard to weight, but AC storage can provide volume reduction, lower pressures in space, and potentially in situ Xe purification. With partial fill designs, a primary AC storage vessel for Xe could also eliminate problems with two-phase storage and regulate pressure. AC could also be utilized in long-term large quantity storage of Xe serving as a compact capture site for boil-off. Several Xe delivery ACSFR protocols between 2 and 45 sccm, and 15 min to 7 hr, were tested with an average flow variance of 1.2 percent, average power requirements of 5 W, and repeatability s of about 0.4 percent. Power requirements are affected by ACSFR bed sizing and flow rate/ duration design points, and these flow variances can be reduced by optimizing PID controller parameters.

Back, Dwight D.↗

Calibration of the Galactic Cosmic Ray Flux

We report first Xe data on the cross-calibration of I-129-Xe-129(sub n) ages with conventional CRE ages, a method which is expected to provide information on the long-term constancy of the galactic cosmic ray (GCR) flux. We studied isotopic signatures of Xe released in stepwise heating, decomposition and melting of troilites in the Cape York iron meteorite to identify isotopic shifts in Xe-129 and Xe-131 due to neutron capture in Te-128 and Te-130. We also resolve components due to extinct 129I, spallation and fission Xe. There has recently been much speculation on the constancy of GCR over long time scales, as may be inferred from iron meteorites. If GCRs originate from supernova events, this provides the basis for postulating increased fluxes at locations with higher than average densities of supernovae, specifically in OB-associations. The solar system at present appears to be inside a local bubble between spiral arms and may experience an increased GCR flux.

Mathew, K. J.↗

Population inversion calculations using near resonant charge exchange as a pumping mechanism

Near resonance charge exchange between ions of a large ionization potential gas such as helium or neon and vapors of metals such as zinc, cadmium, selenium, or tellurium has produced laser action in the metal ion gas. The possibility of obtaining population inversions in near resonant charge exchange systems (Xe-Ca, Xe-Mg, Xe-Sr, Xe-Ba, Ar-Mg, N-Ca) was investigated. The analysis is an initial value problem that utilizes rate equations for the densities of relevant levels of the laser gas (Ca, Ba, Mg, or Sr) and an electron energy equation. Electron excitation rates are calculated using the Bohr-Thomson approximation for the cross section. Approximations to experimental values of the electron ionization cross section and the ion-atom charge exchange cross section are used. Preliminary results have been obtained for the Ca-Xe system and show that it is possible to obtain gains greater than 10 to the 14th power/m with inversion times up to 8x10 to the minus 7th power second. A possible charge exchange laser system using a MPD arc plasma accelerator is also described.

Chubb, D. L.↗

Barites - Anomalous xenon from spallation and neutron-induced reactions

Sedimentary barites from South Africa and Western Australia (about 3 billion years old) contain spallogenic Xe isotopes produced by reactions of Ba with nuclear-active particles in cosmic rays. 'Surface residence time' of these samples was calculated from the observed concentrations of spallogenic Xe-126. Comparison of spallogenic ratios of Xe-131/Xe-126 in the two samples provides evidence for the reaction Ba-130(n, gamma) yields Xe-131, which is characterized by a large number of resonances for neutron absorption in the epithermal region. This observation lends additional support to the conclusions already reached regarding the origin of anomalous Xe-131 in lunar samples.

Srinivasan, B.↗

Atmospheric rare gases in lunar rock 60015

Aliquots of lunar rock 60015 were subjected to various types of exposure and handling designed to produce terrestrial contamination, in order to test the possibility of a terrestrial origin for the terrestrial-like trapped Xe reported for lunar rock samples. Crushing the rock produced up to order-of-magnitude increases in the abundances of Ar, Kr, and Xe relative to the millimeter-sized chips of 60015 previously analyzed. Contrary to expectations for atmospheric contamination, high temperatures (above 1000 C) were necessary to remove about 75% of the trapped Kr and Xe, and the rare-gas elemental abundance ratios differed from those in terrestrial samples believed to have occluded atmospheric gases. It is concluded, on the basis of similar temperature-release profiles and elemental-fractionation patterns, that the trapped Xe observed in all these 60015 analyses is atmospheric contamination. Such a conclusion cannot unequivocally be drawn for other lunar rocks containing terrestrial-like Xe, but the present results demonstrate that arguments based on high extraction temperatures and elemental abundance ratios cannot be useful to rule out rare-gas atmospheric contamination in such samples.

Niemeyer, S.↗

Krypton and xenon in the atmosphere of Venus

The paper reports a determination by the Pioneer Venus large probe neutral mass spectrometer of upper limits to the concentration of krypton and xenon along with most of their isotopes in the atmosphere of Venus. The upper limit to the krypton mixing ratio is estimated at 47 ppb, with a very conservative estimate at 69 ppb. The probable upper limit to the sum of the mixing ratios of the isotopes Xe-128, Xe-129, Xe-130, Xe-131, and Xe-132 is 40 ppb by volume, with a very conservative upper limit three times this large.

Donahue, T. M.↗

Xenon diffusion following ion implantation into feldspar - Dependence on implantation dose

The diffusion properties of xenon implanted into feldspar, a major mineral in meteorites and lunar samples, are investigated in light of the importance of xenon diffusion in the interpretation of early solar system chronologies and the retention time of solar-wind-implanted Xe. Known doses of Xe ions were implanted at an energy of 200 keV into single-crystal plagioclase targets, and depth profiles were measured by alpha particle backscattering before and after annealing for one hour at 900 or 1000 C. The fraction of Xe retained following annealing is found to be strongly dependent on implantation dose, being greatest at a dose of 3 x 10 to the 15th ions/sq cm and decreasing at higher and lower doses. Xe retention is also observed to be unaffected by two-step anneals, or by implantation with He or Ar. Three models of the dose-dependent diffusion properties are considered, including epitaxial crystal regrowth during annealing controlled by the extent of radiation damage, the creation of trapping sites by radiation damage, and the inhibition of recrystallization by Xe during annealing

Melcher, C. L.↗

The dating of pre-exposure times of lunar rocks and soils

Xenon produced by fission of uranium, thorium and plutonium has repeatedly been observed in lunar rocks and soils. In two basaltic rocks and in two soils Xe was found originating from fission of U-235 induced by neutrons which are due to the interactions of cosmic ray particles with lunar matter. Two facts lead to this conclusion: (1) fission Xe is present in excess of that expected for the U, Th, and Pu concentrations and for the gas retention age of the samples; and (2) the Xe-134/Xe-136 ratio of excess fission Xe is close to 1.25 as expected for neutron induced fission of U-235. Information on the duration of the exposure to cosmic rays was obtained from the Kr-81-Kr systematics whereas the effective shielding conditions were derived from the depth sensitive cosmogenic ratio Xe-131/Xe-126. For the four samples the exposure to cosmic rays in the lunar regolith is described by a two stage exposure model. The history of the four samples was derived in terms of duration and shielding depth of the two stages.

Eugster, O.↗

Xenon and other noble gases in shergottites

The isotopic composition of the xenon component trapped in EETA 79001's lithologies B and C has been determined, and other noble gases were measured in some samples. The Xe component was found to have light isotope ratios indistinguishable from those of the terrestrial atmosphere. The trapped component has a Xe-129/Xe-132 ratio of about 2.4, and is enhanced in Xe-134 and Xe-136 relative to the terrestrial atmosphere or the average carbonaceous chondrite. Similarities between values for Ar-40/Ar-36, Xe-129/Xe-132, and N-15/N-14 and the corresponding Martian atmospheric values suggest Martian origin of the trapped gases.

Swindle, T. D.↗

How Mars lost its atmosphere

There is a widespread suspicion that Mars thin atmosphere is in some way attributable to the planet's size. Another possibility is that the atmosphere was never degassed or outgassed in the first place. I prefer escape. Hydrodynamic escape (vigorous thermal escape) and impact erosion (expulsion of atmosphere by impacts) are two processes that should have been operative early. Although in principle hydrodynamic escape could have shrunk Mars atmosphere a hundredfold while leaving the composition of the remnant atmosphere nearly unaltered, very high escape fluxes are required. The implicated escape mechanism must have been efficient, nearly non-fractionating, and vastly more potent for Mars than for Earth or Venus. Impact erosion is an appealing candidate. Noble gases are the obvious first test. Noble gases are the most volatile elements and so are the most likely to have been affected by impact erosion and the easiest to address quantitatively. Xenon in particular imposes three constraints on how Mars lost its atmosphere: (1) the very low abundance of nonradiogenic Xe abundance of nonradiogenic Xe compared to Earth, Venus, and likely meteoritic sources; (2) its nonradiogenic isotopes distinct from likely meteoritic sources; and (3) the relatively high absolute abundance of radiogenic daughter of the extinct radionuclide I-129 (half-life 17 Myr). In impact erosion, the first two become constraints on the composition, mass distribution, and orbital elements of the impactors. The third requires that Mars lost its nonradiogenic Xe early, probably before it was 100 Myr old. Impact erosion can explain Mars by any of three stories. (1) Mars in unlikely. In a sort of planetary brinkmanship, impact erosion almost removed the entire atmosphere but was arrested just in time. (2) Martian noble gases are cometary and cometary Xe is as isotopically mass fractionated as Martian and terrestrial Xe. This is most easily accomplished if a relatively thick geochemically controlled CO2 atmosphere protected trace atmophiles against escape. (3) Mars was indeed stripped of its early atmosphere but a small remnant was safely stored in the regolith, later released as a byproduct of water mobilization.

Zahnle, Kevin↗

A comparison of solar wind and estimated solar system xenon abundances - A test for solid/gas fractionation in the solar nebula

The solar Xe elemental abundance is determined here using solar wind measurements from lunar ilmenites which are normalized to Si by spacecraft data. The results are compared with estimated abundances assuming no fractionation. When corrected for solar wind/photospheric fractionation, the Xe-130 abundance given by surface layer oxidation of ilmenite from solid 71501 exposed within the last 200 m.y. is 0.24 +/- 0.09 normalized to Si = 10 exp 6. This is indistinguishable from estimates made assuming no solid/gas fractionation. Results from breccia 79035 ilmenite exposed at least 1 Gyr ago indicate that the solar wind Xe flux may have been significantly higher relative to other noble gases, perhaps due to more efficient Xe ionization. If this is true, fluxes of C and S, which have first ionization potentials similar to Xe, should also be higher in the ancient solar wind from the same time period.

Wiens, Roger C.↗

Mass Spectrometric Measurement of Martian Krypton and Xenon Isotopic Abundance

The Viking gas chromatograph mass spectrometer experiment provided significant data on the atmospheric composition at the surface of Mars, including measurements of several isotope ratios. However, the limited dynamic range of this mass spectrometer resulted in marginal measurements for the important Kr and Xe isotopic abundance. The Xe-129 to Xe-132 ratio was measured with an uncertainty of 70%, but none of the other isotope ratios for these species were obtained. Accurate measurement of the Xe and Kr isotopic abundance in this atmosphere provides an important data point in testing theories of planetary formation and atmospheric evolution. The measurement is also essential for a stringent test for the Martian origin of the SNC meteorites, since the Kr and Xe fractionation pattern seen in gas trapped in glassy nodules of an SNC (EETA 79001) is unlike any other known solar system resevoir. Current flight mass spectrometer designs combined with the new technology of a high-performance vacuum pumping system show promise for a substantial increase in gas throughput and the dynamic range required to accurately measure these trace species. Various aspects of this new technology are discussed.

Mahaffy, P.↗

Trapping of noble gases in proton-irradiated silicate smokes

We have measured Ne, Ar, Kr, and Xe in Si2O3 'smokes' that were condensed on Al substrates, vapor-deposited with various mixtures of CH4, NH3, H2O3 and noble gases at 10 K and subsequently irradiated with 1 MeV protons to simulate conditions during grain mantle formation in interstellar clouds. Neither Ne nor Ar is retained by the samples upon warming to room temperature, but Xe is very efficiently trapped and retained. Kr is somewhat less effectively retained, typically depleted by factors of about 10-20 relative to Xe. Isotopic fractionation favoring the heavy isotopes of Xe and Kr of about 5-10-percent/amu is observed. Correlations between the specific chemistry of the vapor deposition and heavy noble gas retention are most likely the result of competition by the various species for irradiation-produced trapping sites. The concentration of Xe retained by some of these smokes exceeds that observed in phase Q of meteorites and, like phase Q, they do not seem to be carriers of the light noble gases.

Nichols, R. H., Jr.↗

Noble gases in ancient asteroidal atmospheres

Analytical and numerical results presented here suggest that acceleration of photoions by the solar wind motional field is a significant loss process for Xe on asteroids about 200 km in radius or larger, if the Xe is thermalized by its interactions with the surface. For Ar, photoion acceleration can only become important for asteroids nearly 500 km in radius. Thus photoion acceleration, previously invoked for lunar samples, could be responsible for excess fission-produced Xe found associated with solar wind Xe in howarditic meteorites. The lack of such Xe in other types of meteorites may reflect either smaller parent bodies or later times of regolith exposure. Similarly, the failure to observe solar-wind-associated radiogenic Ar-40 in meteorites is consistent with the much smaller likelihood that Ar will be photoionized.

Swindle, Timothy D.↗

Anomalous Xenon in the Precambrian Nuclear Reactor in Okelobondo (Gabon): A Possible Connection to the Fission Component in the Terrestrial Atmosphere

Some CFF-Xe (Chemically Fractionated Fission Xenon), whose isotopic composition is established by simultaneous decay and migration of radioactive fission products, is probably present in the Earth's lithosphere, a conclusion based on available Xe data from various crustal and mantle rocks . Our recent isotopic analysis of Xe in alumophosphate from zone 13 of Okelobondo (southern extension of Oklo), along with the independent estimation of the isotopic composition of atmospheric fission Xe , supports the hypothesis that CFF-Xe was produced on a planetary scale. Additional information is contained in the original extended abstract.

Meshik, A. P.↗

Radiogenic Xenon-129 in Silicate Inclusions in the Campo Del Cielo Iron Meteorite

Iron meteorites present a challenge for the I-Xe dating technique because it is usually the inclusions, not metal, that contain radiogenic xenon and iodine. Silicate inclusions are frequent in only types IAB and IIE, and earlier studies of irons have demonstrated that I-Xe system can survive intact in these inclusions preserving valuable age information. Our previous studies of the I-Xe record in pyroxene grains from Toluca iron suggested an intriguing relationship between apparent I-Xe ages and (Mg+Fe)/Fe ratios. The I-Xe system in K-feldspar inclusions from Colomera (IIE) had the fingerprint of slow cooling, with an indicated cooling rate of 2-4 C/Ma. Here we present studies of the iodine-xenon system in a silicate-graphite-metal (SiGrMet) inclusion of the IA Campo del Cielo iron meteorite from the collection of the Museum of Natural History in Vienna.

Meshik, A.↗

Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

Radioactive isotopes↗