Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Warm Start”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing a Decontamination Solution for the Low-Earth-Orbit, Cryogenic SPHEREx Mission

To address the scientific goals of NASA’s astrophysics division, the JPL and Caltech’s SPHEREx mission conducts the first near-infrared all-sky spectral survey in low-earth-orbit using a passively-cooled, cryogenic telescope. Several unique water contamination issues arise due to the combination of cryogenic operation temperatures and the limited temperature control authority of passive cooling. Because water molecules have adsorption bands within the wavelengths of interest for SPHEREx’s survey, it is imperative that water contamination be controlled and minimized. In this work, a model is developed for the SPHEREx mission to predict the transport and accumulation of outgassed water onto sensitive payload components. The model utilizes the time dependent thermal profiles of the individual payload components, initial water content, and spacecraft geometry to calculate the time dependent water diffusion, transport, and adsorption. This model is subsequently used to predict water contamination risks and design decontamination solutions for each risk. Two major water contamination risks were predicted, water accumulation during cooldown and on cryogenic surfaces during the mission. The first risk occurs during the cooldown of the payload to cryogenic temperatures, predicting water accumulation on optical surfaces in excess of the allowable levels. To mitigate this accumulation, the temperature of the optical surfaces is controlled during cooldown through a combination of heaters and spacecraft pointing. The second risk is that over the course of the mission, is unavoidable water accumulation onto the payload thermal system’s cryogenic surfaces, possibly jeopardizing thermal performance and temperature stability, both of which are required for science success. To decontaminate any water that had collected onto cryogenic thermal system surfaces, a decontamination maneuver was designed. In this decontamination maneuver, cryogenic surfaces of the thermal system are warmed to a temperature where water will desorb by spacecraft pointing while still meeting all avoidance constraints, and thereby avoiding undue risk to the observatory hardware. Through application of the developed analytical model and inclusion of the decontamination maneuver in the mission design, SPHEREx can confidently demonstrate that it is able to decontaminate, at the start of and during the mission as needed to meet its end of life science performance requirements.

Soares, Carolos E.↗

Enabling the Direct Detection of Earth-Sized Exoplanets with the LBTI HOSTS Project: A Progress Report

NASA has funded a project called the Hunt for Observable Signatures of Terrestrial Systems (HOSTS) to survey nearby solar type stars to determine the amount of warm zodiacal dust in their habitable zones. The goal is not only to determine the luminosity distribution function but also to know which individual stars have the least amount of zodiacal dust. It is important to have this information for future missions that directly image exoplanets as this dust is the main source of astrophysical noise for them. The HOSTS project utilizes the Large Binocular Telescope Interferometer (LBTI), which consists of two 8.4-m apertures separated by a 14.4-m baseline on Mt. Graham, Arizona. The LBTI operates in a nulling mode in the mid-infrared spectral window (8-13 micrometers), in which light from the two telescopes is coherently combined with a 180 degree phase shift between them, producing a dark fringe at the location of the target star. In doing so the starlight is greatly reduced, increasing the contrast, analogous to a coronagraph operating at shorter wavelengths. The LBTI is a unique instrument, having only three warm reflections before the starlight reaches cold mirrors, giving it the best photometric sensitivity of any interferometer operating in the mid-infrared. It also has a superb Adaptive Optics (AO) system giving it Strehl ratios greater than 98% at 10 micrometers. In 2014 into early 2015 LBTI was undergoing commissioning. The HOSTS. project team passed its Operational Readiness Review (ORR) in April 2015. The team recently published papers on the target sample, modeling of the nulled disk images, and initial results such as the detection of warm dust around eta Corvi. Recently a paper was published on the data pipeline and on-sky performance. An additional paper is in preparation on Beta Leo. We will discuss the scientific and programmatic context for the LBTI project, and we will report recent progress, new results, and plans for the science verification phase that started in February 2016, and for the survey.

Hunt for Observable Signatures of Terrestrial Syst↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Enceladus and Europa: How Does Hydrothermal Activity Begin at the Surface?

The question of how the surface hydrothermal activity (e.g., eruptive plumes and heat flow) is initiated can be addressed within the frame-work of our "Perrier Ocean" model. This model delivers the necessary heat and chemicals to support the heat flow and plumes observed by Cassini in Enceladus' South Polar Region. The model employs closed-loop circulation of water from a sub-surface ocean. The ocean is the main reservoir of heat and chemicals, including dissolved gases. As ocean water moves up toward the surface, pressure is re-duced and gases exsolve forming bubbles. This bub-bly mixture is less dense than the icy crust and the buoyant ocean-water mixture rises toward the surface. Near the surface, heat and chemicals, including some volatiles, are delivered to the chambers in which plumes form and also to shallow reservoirs that keep the surface ice "warm". (Plume operations, per se, are as described by Schmidt et al. and Postberg et al. and are adopted by us.) After transferring heat, the water cools, bubbles contract and dissolve, and the mixture is now relatively dense. It descends through cracks in the crust and returns to the ocean. Once the closed-loop circulation has started it is self-sustaining. Loss of water via the erupting plumes is relatively negligible compared to the amount needed to maintain the heat flow.We note that the activity described herein for the the "Perrier-Ocean" model could, a priori, apply to all small icy bodies that sheltered an interior ocean at some point in their history.

Enceladus↗

Hybrid Heat Pipes for Lunar and Martian Surface and High Heat Flux Space Applications

Novel hybrid wick heat pipes are developed to operate against gravity on planetary surfaces, operate in space carrying power over long distances and act as thermosyphons on the planetary surface for Lunar and Martian landers and rovers. These hybrid heat pipes will be capable of operating at the higher heat flux requirements expected in NASA's future spacecraft and on the next generation of polar rovers and equatorial landers. In addition, the sintered evaporator wicks mitigate the start-up problems in vertical gravity aided heat pipes because of large number of nucleation sites in wicks which will allow easy boiling initiation. ACT, NASA Marshall Space Flight Center, and NASA Johnson Space Center, are working together on the Advanced Passive Thermal experiment (APTx) to test and validate the operation of a hybrid wick VCHP with warm reservoir and HiK"TM" plates in microgravity environment on the ISS.

Ababneh, Mohammed T.↗

Interdecadal Trichodesmium Variability in Cold North Atlantic Waters

Studies of the nitrogen cycle in the ocean generally assume that the distribution of the marine diazotroph, Trichodesmium, is restricted to warm, tropical, and subtropical oligotrophic waters. Here we show evidence that Trichodesmium are widely distributed in the North Atlantic. We report an approximately vefold increase during the 1980s and 1990s in Trichodesmium presence near the British Isles with respect to the average over the last 50 years. A potential explanation is an increase in the Saharan dust source starting in the 1980s, coupled with changes in North Atlantic winds that opened a pathway for dust transport. Results from a coarse-resolution model in which winds vary but iron deposition is climatologically fixed suggest frequent nitrogen limitation in the region and reversals of the Portugal current, but it does not simulate the observed changes in Trichodesmium. Our results suggest that Trichodesmium may be capable of growth at temperatures below 20C and challenge assumptions about their latitudinal distribution. Therefore, we need to reevaluate assumptions about the temperature limitations of Trichodesmium and the dinitrogen (N2) xation capabilities of extratropical strains, which may have important implications for the global nitrogen budget.

Rivero-Calle, Sara↗

Assimilation of GOES Land Surface Data Within a Rapid Update Cycle Format: Impact on MM5 Warm Season QPF

A technique has been developed for assimilating GOES-derived skin temperature tendencies and insolation into the surface energy budget equation of a mesoscale model so that the simulated rate of temperature change closely agrees with the satellite observations. A critical assumption of the technique is that the availability of moisture (either from the soil or vegetation) is the least known term in the model's surface energy budget. Therefore, the simulated latent heat flux, which is a function of surface moisture availability, is adjusted based upon differences between the modeled and satellite-observed skin temperature tendencies. An advantage of this technique is that satellite temperature tendencies are assimilated in an energetically consistent manner that avoids energy imbalances and surface stability problems that arise from direct assimilation of surface shelter temperatures. The fact that the rate of change of the satellite skin temperature is used rather than the absolute temperature means that sensor calibration is not as critical. The focus of this paper is to examine how the satellite assimilation technique impacts simulations of near-surface meteorology on the 0-to 12-hour time scale when implemented within a local rapid update cycle (LRUC) format. The PSU/NCAR MM5 V34 is used and configured with a 36-km CONUS domain and a 12-km nest centered over the southeastern US. The LRUC format consists of a sequence of 12-hour forecasts initialized every hour between 12 and 18 UTC seven days a week. GOES skin temperature tendencies and solar insolation are assimilated in a 1-hour period prior to the start of each twelve-hour forecast. A unique aspect of the LRUC is the satellite assimilation and the continuous recycling of the adjusted moisture availability field from one forecast cycle to the next. Preliminary results for a seven-day trial period indicate that hourly LST tendencies assimilated in a 1 hour LRUC showed improved simulated air and dewpoint temperatures for all cycles on each day. The LRUC will be used during the 2001 summer months to identify the impact of the assimilation on warm season QPF Results will be presented at the meeting.

Lapenta, William M.↗

Heating analysis of bent-nose biconics at high angles of attack using the parabolized Navier-Stokes equations

A method based on the Parabolized Navier-Stokes equations is used to calculate the flow field and heat transfer of lifting entry vehicles. The method is based on the Bean and Warming implicit algorithm and uses a new procedure for preventing departure solutions. Calculations are carried out for blunt on-axis and bent biconics, assuming a perfect gas and laminar flow, and compared with available heat transfer, surface pressure and shock shape measurements for a range of Mach numbers and angles of attack. In all calculations presented here, the starting solution is obtained from available inviscid and boundary layer codes. Good agreement with experiment is indicated. Thus, the method provides an accurate and rather inexpensive procedure for calculating three-dimensional flows at supersonic Mach numbers.

Stephenson, B. L.↗

A Long-Term Space Astrophysics Research Program. An X-Ray Perspective of the Components and Structure of Galaxies

We present optical and archival X-ray data on the disturbed morphology radio elliptical NGC 1316 (Fornax A) that displays numerous low surface brightness shells, loops and tails. An extended (81x27 min or 9x3 kpc) emission line region (EELR) at a projected distance of 35 kpc from the nucleus has been discovered in a approximately 9Ox35 kpc, approximately 3.Ox1O(solar luminosity(B)) tidal tail. The position and extreme size of the EELR suggest it is related to the merger process. We suggest that the ionization mechanism of the EELR is shock excitation, and the gas is remnant from the merger progenitor. X-ray emission is detected near two tidal tails. Hot, approximately 5 x 10(exp 6)K gas is probably the predominant gas component in the tidal tail ISM. However based on the current tidal tail (cold + warm + hot) gas mass, a large fraction of the tidal tail progenitor gas may already reside in the nucleus of NGC 1316. The numerous and varied tidal tail system suggests that a disk-disk or disk-E merger could have taken place greater than or equal to 1 Gyr ago, whilst a low mass, gas rich galaxy started to merge approximately 0.5 Gyr ago.

Fabbiano, G.↗

Pressure Deficit in Gale Crater and a Larger Northern Polar Cap After the MY34 Global Dust Storm

We describe the model-independent analysis technique of Mars Science Laboratory (MSL) pressure and Mars Climate Sounder (MCS) data in de la Torre Juárez et al. (2019, https://doi.org/10.22541/essoar.169945479.90436599/v1) that compared multiple years of surface pressures on Gale before, during, and after the Global Dust Storm of Mars Year 34. The analysis found (a) representative pressure scale heights over Gale; (b) that the storm was followed by a pressure deficit at Gale; (c) the following C storms did not eliminate the deficit; (d) changes in the duration of the polar caps condensation seasons, with an early start of the North Polar (NP) ice cap growing season the year before the Great Dust Storm (GDS) and a late signature of the end of the expansion season thereafter, changes consistent with a larger growth phase of the NP cap; (e) MCS observed a larger than usual NP cap; and (f) cold temperature anomalies over the NP and warm over the Southern Pole after the storm. We also show that the analysis of observed MSL pressure data alone filters out effects on the pressure signal that are attributable to dynamical and orographic processes in a recent model analysis that makes similar interpretations as our 2019 study. One additional Mars year of observations is included to eliminate early concerns about sensor drifts. Noting that a similar NP anomaly was observed with MCS data after the last early GDS in MY25, and not the later GDS of MY27, the results suggest a possible unique effect of early GDSs.

Manuel de la Torre Juárez↗

Cyclogenesis in a saturated environment

The dynamics of baroclinic wave growth in a saturated environment is examined using linear and nonlinear models employing a parameterization of latent heat release that assumes all rising air is saturated, and saturation equivalent potential temperature is conserved on ascent. Piecewise potential vorticity (PV) diagnostics are used to interpret the results. When the stability to vertical displacements in saturated air is allowed to increase with height, as it must in an atmosphere with a constant, positive lapse rate of potential temperature, the growth rates of the most unstable modes of the Eady problem grow only marginally faster than the modes of the dry problem. The vertical variation of moist static stability produces a gradient of moist potential vorticity in the rising air, eliminating the short-wave cutoff present in the dry Eady problem. The destabilization of the short waves is shown to be associated with the interaction between surface potential temperature anomalies and diabatically generated lower-tropospheric potential vorticity anomalies. Nonlinear primitive equation simulations, starting from normal-mode initial conditions, show that while the dry wave grows at nearly the linear growth rate until maximum amplitude is reached, the moist wave grows significantly faster than the linear growth rate at finite amplitude. This enhanced growth is associated with the rapid amplification of a mesoscale PV anomaly generated by latent heat release at the warm front. The rapid amplification of the surface cyclone results from the superposition of the circulation associated with this misoscale PV anomaly upon the circulation associated with the surface and upper boundary potential temperature anomalies. Additional integrations with finite-amplitude initial conditions more typical of atmospheric conditions exhibit similar behavior. It is suggested that many of the rapid cyclogenesis events that occur as upper-troposheric PV anomalies cross the east coasts of continents may arise from the rapid generation of PV anomalies by condensational heating in the moist maritime lower troposphere.

Whitaker, Jeffrey S.↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

Predictability of the 1997 and 1998 South Asian Summer Monsoons

The predictability of the 1997 and 1998 south Asian summer monsoon winds is examined from an ensemble of 10 Atmospheric General Circulation Model (AGCM) simulations with prescribed sea surface temperatures (SSTs) and soil moisture, The simulations are started in September 1996 so that they have lost all memory of the atmospheric initial conditions for the periods of interest. The model simulations show that the 1998 monsoon is considerably more predictable than the 1997 monsoon. During May and June of 1998 the predictability of the low-level wind anomalies is largely associated with a local response to anomalously warm Indian Ocean SSTs. Predictability increases late in the season (July and August) as a result of the strengthening of the anomalous Walker circulation and the associated development of easterly low level wind anomalies that extend westward across India and the Arabian Sea. During these months the model is also the most skillful with the observations showing a similar late-season westward extension of the easterly CD wind anomalies. The model shows little predictability or skill in the low level winds over southeast Asia during, 1997. Predictable wind anomalies do occur over the western Indian Ocean and Indonesia, however, over the Indian Ocean they are a response to SST anomalies that were wind driven and they show no skill. The reduced predictability in the low level winds during 1997 appears to be the result of a weaker (compared with 1998) simulated anomalous Walker circulation, while the reduced skill is associated with pronounced intraseasonal activity that is not well captured by the model. Remarkably, the model does produce an ensemble mean Madden-Julian Oscillation (MJO) response that is approximately in phase with (though weaker than) the observed MJ0 anomalies. This is consistent with the idea that SST coupling may play an important role in the MJO.

Schubert, Siegfred D.↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗