Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Application of fracture mechanics to predict the strength of filament-wound composite specimens with surface damage

The strength of a thick surface notched filament wound graphite/epoxy tensile specimen was predicted using fracture mechanics analysis. The prediction model depended upon the depth of the surface notch and upon the type of failure. Specimens failed in two stages: first a sublaminate with thickness equal to the depth of the surface cut, and second, for increasing load, a sublaminate with thickness equal to the initial thickness minus the cut depth. Analytical predictions and experimental data were in good agreement.

Morris, D. H.↗

Fiber optic strain measurements in filament-wound graphite-epoxy tubes containing embedded fibers

Filament-wound graphite-epoxy tubes fabricated with embedded fiber optic sensors were tested at NASA Langley Research Center to evaluate the feasibility of monitoring stress with a fiber optic technique. Resistance strain gauges were attached to the tubes to measure strain at four locations along the tubes. Both static and dynamic strain measurements were made with an excellent agreement between the embedded fiber optic strain sensor and the strain gauges. The results indicate that fiber optic sensors embedded in composites may be useful as the sensing component of smart structures.

Rogowski, R. S.↗

A model of filament-wound thin cylinders

A model was developed for simulating he manufacturing process of filament-wound cylinders made of a thermoset matrix composite. The model relates the process variables (winding speed, fiber tension, applied temperature) to the parameters characterizing the composite cylinder and the mandrel. The model is applicable to cylinders for which the diameter is large compared to the wall thickness. The model was implemented by a user-friendly computer code suitable for generating numerical results.

Calius, Emilio P.↗

Predicting the strength of filament-wound specimens with surface cuts

The notched strength of filament-wound composite specimens was determined for coupons with various sized semielliptic surface notches. When the part-through notches did not cut the first 0-deg layer the strength was independent of the size of the notch and was equal to the unnotched tensile strength. When the cut penetrated 0-deg layers, the specimens failed in a two-part failure mode. The first part of the failure was modeled using fracture mechanics and a straight line tangent to the fracture mechanics solution, and the second part of the failure was modeled using a failure criterion that accounted for the moduli of 0-deg and helical layers.

Morris, Don H.↗

An ultrasonic technique to measure the depth of burn wounds in humans

Whenever ultrasound encounters discontinuity in its medium of propagation, some energy is reflected from the interface. Such reflections or echoes occur when incident energy encounters the front skin, viable/necrotic, and dermis/fat skin tissue interfaces. It was shown that the most probable cause of the viable/necrotic interface is the uncoiling of collagen in the necrotic tissue, which can cause a reflection at the viable/necrotic interface of approximately 10 percent of the wave amplitude, and is approximately the same as that from the other two interfaces noted. The instrument, still in the prototype stage, was designed to detect the various reflections from within the skin layer. It is shown that, by studying the timing between the various echoes, one can use ultrasound as an aid in diagnosing the depth of burned skin tissue in humans. The instrument is a 60-MHz A-scan unit, modified to more easily identify the echoes occurring within the short time interval during which the reflections are received from the skin layers. A high frequency unit was selected so that various transducers could be utilized to optimize the system. Signal conditioning circuits were modified and added to provide an adequate display of the principle reflections expected. The unit was successful in studying burned tissue in pigs and was recently used to study burn wounds in humans. Measurement techniques and preliminary results are presented.

Yost, William T.↗

Measurement of the performance of a spiral wound polyimide regenerator in a pulse tube refrigerator

A regenerator for use in a pulse tube refrigerator has been constructed from a polyimide (polypyromellitimide or PPMI) whose small ratio of thermal conductivity to heat capacity make it a good candidate for a regenerator material in cryocoolers. The regenerator was fabricated using 25 micron thick photoresist strips bonded to a 50 micron thick sheet of PPMI. This composite sheet was wound in jelly-roll fashion around a mandrel and inserted into the regenerator housing. The photoresist strips, formed using a photolithographic technique, provided a 25 micron spacing for the axial flow of gas between each layer of PPMI. Ineffectiveness results are presented for this material under actual operating conditions in a pulse tube refrigerator and compared with a numerical model. The numerical model indicated that a polyimide regenerator would perform much better than one constructed of stainless steel screen, but the experimental results showed the opposite behavior. Measured values for the ineffectiveness were 0.003 for the stainless steel screen and 0.017 for the polyimide.

Rawlins, Wayne↗

Impedance measurements on a spiral-wound nickel/metal hydride cell cycled in a simulated Leo orbit

A spiral-wound size C cell was cycled at 25 C in a low earth orbit (LEO) regime at 50 percent depth of discharge (DOD) with approximately five percent over-charge. The nominal capacity was 3.5 AH. The cell was cycled for 2000 cycles. Capacity checks and impedance measurements over the complete range of state of charge were made upon receipt and after 500, 1000, and 2000 cycles. The capacity of the cell was essentially unchanged until after the impedance measurements at 2000 cycles. Only small changes in the impedance parameters were observed, but there was somewhat more scatter in the data after 2000 cycles. When the cell was returned to LEO cycling after 2000 cycles, only 38 percent of the capacity could be obtained. It is believed that the cell failed because of an equipment failure at the end of the final impedance measurements which allowed an over-discharge.

Reid, Margaret A.↗

Unlined Reuseable Filament Wound Composite Cryogenic Tank Testing

An unlined reusable filament wound composite cryogenic tank was tested at the Marshall Space Flight Center using LH2 cryogen and pressurization to 320 psig. The tank was fabricated by Phillips Laboratory and Wilson Composite Group, Inc., using an EnTec five-axis filament winder and sand mandrels. The material used was IM7/977-2 (graphite/epoxy).

Murphy, A. W.↗

Quantification of Processing Effects on Filament Wound Pressure Vessels

A computational simulation procedure is described which is designed specifically for the modeling and analysis of filament wound pressure vessels. Cylindrical vessels with spherical or elliptical end caps can be generated automatically. End caps other than spherical or elliptical may be modeled by varying circular sections along the x-axis according to the C C! end cap shape. The finite element model generated is composed of plate type quadrilateral shell elements on the entire vessel surface. This computational procedure can also be sued to generate grid, connectivity and material cards (bulk data) for component parts of a larger model. These bulk data are assigned to a user designated file for finite element structural/stress analysis of composite pressure vessels. The procedure accommodates filament would pressure vessels of all types of shells-of-revolution. It has provisions to readily evaluate initial stresses due to pretension in the winding filaments and residual stresses due to cure temperature.

Aiello, Robert A.↗

Distributed Sensing of Carbon-Epoxy Composites and Filament Wound Pressure Vessels Using Fiber-Bragg Gratings

Multiple Fiber Bragg-gratings are embedded in carbon-epoxy laminates as well as in composite wound pressure vessel. Structural properties of such composites are investigated. The measurements include stress-strain relation in laminates and Poisson's ratio in several specimens with varying orientation of the optical fiber Bragg-sensor with respect to the carbon fiber in an epoxy matrix. Additionally, fiber Bragg gratings are bonded on the surface of these laminates and cylinders fabricated out of carbon-epoxy composites and multiple points are monitored and compared for strain measurements at several locations.

Grant, J.↗

Structural Analysis of Helios Filament-Wound Tanks Subjected to Internal Pressure and Cooling

A finite-element stress analysis is performed on Helios filament-wound hydrogen tanks to examine the stress field and effect of end dome geometry on the stress field. Each tank is composed of a central circular cylindrical section with either geodesic or hemispherical end domes, which have metallic polar bosses. The tanks are subjected to combined and separate internal pressure and temperature loading conditions, and the stress contributions of each loading component are examined. The tank-wall-polar-boss interfacial meridional tensile stress in the hemispherical dome is found to be approximately 27 percent lower than that in the geodesic dome. The effects of both material anisotropy and the aluminum lining on the intensities of tensile meridional stress at the tank-wall-polar-boss bonding interface are examined.

Ko, William L↗

Tethered Space Satellite-1 (TSS-1): Wound About a Bolt

In the early 1990's US and Italian scientists collaborated to study the electrodynamics on a long tether between two satellites as it moved through the electrically charged portion of Earth's atmosphere called the ionosphere. Potential uses for the electrical current induced in the long wire include power and thrust generation for a satellite, momentum exchange, artificial gravity, deployment of sensors or antennas, and gravity-gradient stabilization. The Tethered Space Satellite (TSS) was a first-of-its-kind experiment with long tethers in space. It consisted of a satellite with science experiments attached to a 12.5 mile long, very thin (0.10 inch diameter) copper wire assembly wound around a spool in the deployer reel mechanism. The whole mechanism sits on a pallet that is installed into the Shuttle bay. At an altitude of 160 nautical miles above earth, the satellite would be deplodeployed from the Shuttle bay by raising it on a boom facing away from Earth. Once cleared of the bay, the deployer mechanism would slowly feed out the 12-plus miles of tether. Scientific data would be collected throughout the operation, after which the satellite would be reeled back in. A receiver spool to catch the 12.5 mile tether as it was being unwound by the deployer reel mechanism was set up to do the system-level test of deployer real mechanism prior to installing the loaded pallet into the Shuttle bay. The system level tests were required before the pallet could be installed into the Space Shuttle cargo bay. A few months before flight, the system level tests, including unreeling and reeling the tether, were completed at Kennedy Space Center (KSC) and the TSS payload was installed onto the Spacelab pallet. Some of this testing equipment was then shipped back to the contractor, Martin Marietta. Integration with the Shuttle began. Systems-level load analyses, which cannot be run until all information about each payload is finalized, was run in parallel with the physical integration of the hardware into the Shuttle payload bay. An analysis, called Coupled loads analysis, incorporates any updates to the model due to system level tests of all the different payloads, and any changes that were found during integration. Engineering analysis examines the worst case scenarios for the loads the hardware will see. The two times during the mission where the dynamic loads are the worst were 1) the first 10-second portion of Shuttle lift off, and 2) a 2-second time during landing when the landing gears hit the ground. The coupled loads analysis using the final verification loads showed that a single bolt attaching the deployer reel mechanism to the support structure had a "negative margin" - which is an indication that it might fail - during touch down. Hardware certification rules do not allow for hardware to fly with negative margins. A structural failure of one payload could have serious or catastrophic consequences to other payloads, or may significantly damage the Orbiter. The issue had to be resolved before the flight.

O'Connor, Brian↗

A Damage Resistance Comparison of Wet-Wound IM7 and T1100 Carbon Fiber/Epoxy Cylinders

This technical report presents the results of a damage tolerance comparison of two wet-wound cylinders; one made with IM7 carbon fiber and the other with T1100 carbon fiber. Damage was inflicted on the cylinders in the form of impact and the resulting damage was assessed mainly by cross-sectional examination of the damage zone after impact. Due to financial restraints, no residual strength testing was performed in this study. The amount of fiber breakage was the response variable of interest since fiber breakage, rather than delaminations or other matrix damage, governs the burst strength of rocket motor cases. The results showed that the T1100 fiber may be slightly more damage resistant than the IM7 fiber.

A T Nettles↗

Brushless Excitation for Wound-field Synchronous Machines using Multi-harmonic Windings

Wound-field synchronous machines (WFSM) are promising alternatives to electric machines with permanent magnets (PM). The ability to control the rotor field in these machines makes them well-suited to safety critical applications, while the absence of rare-earth permanent magnets makes these machines sustainable. The WFSM rotor excitation schemes have traditionally used carbon brushes, which significantly reduces the reliability of these machines, limiting their widespread adoption. To overcome this limitation and improve the reliability of WFSMs, several brushless rotor excitation schemes have been developed. However, most of these systems require additional windings or dedicated power electronics, making them expensive and limiting achievable power-density. In this paper a new brushless excitation scheme is proposed. In this scheme, a multiphase, multi-harmonic stator winding is designed. This winding can independently control two spatial harmonics in the airgap of the machine; the first to create torque and the second to wirelessly transfer power to the rotor to excite it.

Gadiyar, Nishanth [ORNL] (ORCID:0000000348267524)↗