Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WECC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Adaptive Decentralized Dynamic State Estimation with Unknown Control Inputs using Field PMU Measurements

This paper proposes a robust adaptive decentralized dynamic state estimation method for power system with unknown inputs of the highly detailed synchronous machine model. The temporal and spatial correlations among the unknown inputs are used to derive a vector auto-regressive model. The latter is further integrated together with state transition and measurement models for joint state and unknown inputs estimation. Thanks to the consideration of implicit cross-correlations between the states and the unknown inputs, only generator terminal voltage and current phasors are needed. Test results on the US WECC system using the field PMU measurements show that the proposed method is able to track both the system dynamic states and unknown controller inputs. These information could significantly benefit the validation and calibration of generator controller parameters.

Zhao, Junbo↗

Ambient Synchrophasor Measurement Based System Inertia Estimation

This paper develops an algorithm to estimate the system inertia value based on ambient synchrophasor measurement. Informative features are extracted from ambient synchrophasor measurements for machine-learning-based inertia estimation. Besides ambient synchrophasor measurements of FNET/GridEye, other available data relevant to inertia (such as weather and system load data) are also used to improve the inertia estimation accuracy. Then a machine learning algorithm to estimate system inertia is developed. A test dataset including ambient synchrophasor data from FNET/GridEye measurements and the WECC system inertia data from NERC is used to evaluate the performance of the developed inertia estimation method. The average and maximum estimation errors of the developed inertia estimation method is lower than 5% and 10%, respectively. This accuracy is higher than reported accuracy values in existing literature.

CUI, YI↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Technical Sessions

This presentation provides summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward a technical audience. A companion policy presentation provides higher-level summaries of the same material.

distributed energy resource↗

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Policy Sessions

This presentation provides high-level summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward policy decision makers. A companion technical presentation provides more in-depth summaries of the same material.

distributed energy resource↗

Formulations and Valid Inequalities for Optimal Black Start Allocation in Power Systems

The restoration of a power system after a blackout starts around units with enhanced technical capabilities, referred to as black start units (BSUs). We examine the planning problem of optimally allocating these units on the grid subject to a budget constraint. We present a mixed integer programming model based on current literature in power systems. Binary variables are associated with the allocation of BSUs and with the energization state of buses, branches, and generators of the power system over a time horizon. We extract a substructure of the feasible region which imposes the requirement that each island that appears during the restoration process must have at least one operational generator. We discuss three equivalent reformulations for this requirement. We introduce a family of exponentially many, polynomially separable, valid inequalities to strengthen the formulation. Under simplifying assumptions, we show that the convex hull of the feasible region is a full-dimensional polyhedron, and prove that some of the constraints we introduced are facet-defining. We perform experiments to examine the difference in strength between the formulations as well as the computational times to solve the problem to near optimality for synthetic instances of the IEEE-39, IEEE-118, Illinois-200, WECC-225, IEEE-300, South Carolina-500, and Texas-2000 power systems. We illustrate a use case of the model. We conclude by suggesting extensions of the current work for future research.

Black Start Allocation↗

Transmission-Distribution Dynamic Co-Simulation of Electric Vehicles Providing Grid Frequency Response: Preprint

This paper investigates the impacts of electric vehicles (EVs) on power system frequency regulation based on an open-source transmission-and-distribution (T&D) dynamic co-simulation framework. The development of a EV dynamic model based on appropriate WECC dynamic model is introduced first, then the T&D dynamic co-simulation platform is described. The advantage of the overall platform is that DERs such as distributed photovoltaic (DPV) and EV are modeled explicitly in both transmission and distribution simulators for frequency dynamics and voltage, respectively. In the case studies, EVs frequency responses (i.e., primary and/or secondary) are simulated after the system is exposed to N-1 contingency such as a generation trip. Various EV frequency regulation participation strategies are investigated as well to study their impacts on system frequency response. The studies shows that EVs have potential capability to provide effective frequency regulation services.

electric vehicle↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response: Preprint

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVDl model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

ADVANCED PROPULSION SYSTEMS↗

Deployment Feasibility Futures Analysis of Natural Gas Combined Cycle with Carbon Capture in Five U.S. Regions

A broad suite of technologies will be required to enable the United States to meet the current goal of a zero-carbon power sector by 2035, while continuing to provide the U.S. consumer with reliable, secure, stable, and affordable electricity. This study was conducted to evaluate the competitiveness of a natural gas combined cycle (NGCC) with carbon capture and storage (CCS) in five independent system operating areas, the PJM interconnection (PJM) regional transmission organization, Midcontinent Independent System Operator (MISO), Western Electricity Coordinating Council’s (WECC) Northwest Power Pool (NWPP) region, the Electric Reliability Council of Texas (ERCOT) and the SERC Reliability Corporation (SERC) in the 2030 to 2035 time horizon. The modeling and simulation efforts focused on determining the dispatch characteristics and the economic feasibility of constructing an NGCC plant with CCS in each of those regions. The analysis indicates that a NGCC system with CCS can be economically viable in the ERCOT and PJM regions. Additional revenue stream and/or capacity payments are required in MISO, NWPP, and SERC to enable successful commercial deployment of a NGCC with CCS.

Pickenpaugh, Gavin↗

Impact of Glen Canyon Generation Loss

Colorado River Basin hydropower generation has faced challenges due to droughts and ecological and social water requirements. Specifically, Glen Canyon hydropower generation fluctuates substantially with recent extreme weather trends. Further, the western grid evolves with higher wind and solar share, and Glen Canyon hydropower's contribution to grid flexibility services is essential. The Western Area Power Administration (WAPA) markets and schedules electricity production at GCD, and the loss of this power could have significant financial consequences for the WAPA Colorado River Storage Project's (CRSP) Office because it may need to purchase relatively large amounts of energy to serve its firm electrical obligations. In addition, GCD provides grid reliability services for the WAPA Colorado-Missouri (WACM) balancing authority (BA). Both WAPA and DOE's Water & Power Technology Office (WPTO) are interested in researching how these drier hydrological conditions will impact federal electrical energy production, the Western Electricity Coordinating Council (WECC) power grid, and the value of hydropower in the face of lower production. We study multiple hydrologic and power grid scenarios to understand the grid impacts of the loss of Glen Canyon generation. The study uses a production cost model, water resources planning models, water-centric grid models, and various data analytic techniques. The study progress presentation discusses the selection of probable CRSP' hydropower scenarios and power grid scenarios to understand the impacts of Glen Canyon generation, which includes technologies that compensate the Glen Canyon energy and ancillary services contributions, transmission availability, and energy local marginal prices at interested grid locations of WAPA operation.

droughts↗

The Role of Regional Connections in Planning for Future Power System Operations Under Climate Extremes

Identifying the sensitivity of future power systems to climate extremes must consider the concurrent effects of changing climate and evolving power systems. We investigated the sensitivity of a Western U.S. power system to isolated and combined heat and drought when it has low (5%) and moderate (31%) variable renewable energy shares, representing historic and future systems. We used an electricity operational model combined with a model of historically extreme drought (for hydropower and freshwater-reliant thermoelectric generators) over the Western U.S. and a synthetic, regionally extreme heat event in Southern California (for thermoelectric generators and electricity load). We found that the drought has the highest impact on summertime production cost (+10% to +12%), while temperature-based deratings have minimal effect (at most +1%). The Southern California heat wave scenario impacting load increases summertime regional net imports to Southern California by 10-14%, while the drought decreases them by 6-12%. Combined heat and drought conditions have a moderate effect on imports to Southern California (-2%) in the historic system and a stronger effect (+8%) in the future system. Southern California dependence on other regions decreases in the summertime with the moderate increase in variable renewable energy (-34% imports), but hourly peak regional imports are maintained under those infrastructure changes. By combining synthetic and historically driven conditions to test two infrastructures, we consolidate the importance of considering compounded heat wave and drought in planning studies and suggest that region-to-region energy transfers during peak periods are key to optimal operations under climate extremes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

U.S. Department of Energy Energy Efficiency Conservation Block Grant (Better Buildings Neighborhood Program Report) [Slides]

The Wisconsin Energy Efficiency (WE2) Program delivered residential and commercial programming for the City of Milwaukee (Me2) and the City of Madison (Green Madison) as well as commercial only programming for the City of Racine (Re2). Direct incentives and loan products for homeowners and business owners were offered, with the goal to achieve at least 15 percent in energy savings. At the time of this report, there were more than 2,000 residential energy efficiency upgrades completed and more than 300 commercial energy efficiency upgrades completed. The average energy savings for the WE2 Program’s portfolio of residential and commercial projects exceeds 15 percent and is closer to 30 percent energy savings. Combined energy savings of both residential and commercial activities were: 20,937,369 kWh; 1,018,907 Therms; and 31,655 gallons of heating oil; or at least 332,788 MMBTUs; or at least $\$3,444,828$ in estimated energy costs saved. Conservative economic impact estimates include the employment of more than 100 residential auditors and contractors, more than 90 commercial contractors, and more than $\$41$ million in total project costs expended in the targeted communities.

99 GENERAL AND MISCELLANEOUS↗