Topological Equivalence of VSI and CSI Commutation Cells and Its Application to Switching Resonance Analysis and Damper Design
This paper proposes the concept of the topological equivalence between the commutation cells of a voltage source inverter (VSI) and a current source inverter (CSI) using duality and equivalent circuit transformation techniques. A switching resonance of CSI is analyzed and an effective three-phase RC damper is derived from the dc-link RC damper of VSIs based on the topological equivalence of the VSI and CSI commutation cells. Furthermore, a new three-phase RC damper design framework utilizing the topological equivalence is proposed. Here, experimental results verify that the proposed three-phase RC damper design for CSI significantly reduces the switching resonance and improves the CSI’s output waveform total harmonics distortions (THDs).