Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Modeling Rate Dependent Volume Change in Porous Electrodes in Lithium-Ion Batteries

Automotive manufacturers are working to improve individual cell, module, and overall pack design by increasing the performance, range, and durability, while reducing cost. One key piece to consider during the design process is the active material volume change, its linkage to the particle, electrode, and cell level volume changes, and the interplay with structural components in the rechargeable energy storage system. As the time from initial design to manufacture of electric vehicles decreases, design work needs to move to the virtual domain; therefore, a need for coupled electrochemical-mechanical models that take into account the active material volume change and the rate dependence of this volume change need to be considered. In this study, we illustrated the applicability of a coupled electrochemical-mechanical battery model considering multiple representative particles to capture experimentally measured rate dependent reversible volume change at the cell level through the use of an electrochemical-mechanical battery model that couples the particle, electrode, and cell level volume changes. By employing this coupled approach, the importance of considering multiple active material particle sizes representative of the distribution is demonstrated. The non-uniformity in utilization between two different size particles as well as the significant spatial non-uniformity in the radial direction of the larger particles is the primary driver of the rate dependent characteristics of the volume change at the electrode and cell level.

Electrochemistry↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mutual Diffusion Coefficients of Na 2 SO 4 at C = 0.02989 mol·dm -3 and 298.15 K by Using Rayleigh Interferometry with Free Diffusion Boundary Conditions: Experimental Test of the Effect of the C 3/2 Concentration Dependence of Refractive Index at Low Concentration

Rayleigh interferometry is one of the most precise and accurate methods for the experimental determination of the mutual diffusion coefficients of both electrolytes and non-electrolytes in liquid solutions. For binary solutions at moderate and high concentrations where the concentration dependences of both diffusion coefficient and refractive index can be assumed to be linear or almost linear and the concentration difference ΔC between a pair of solutions undergoing free diffusion is not large compared to their average concentration, and by using proper combinations of the interference fringe positions as they vary with time, under these conditions diffusion coefficients are obtained that are independent of the size of ΔC. However, this situation becomes more complicated at low concentrations for electrolyte solutions where the concentration dependences of both the diffusion coefficient and refractive index are non-linear, with C 1/2 dependence for the diffusion coefficient and C 3/2 dependence for the refractive index. As a test of these effects on calculated mutual diffusion of electrolyte solutions at low concentrations as measured by Rayleigh interferometry, apparent mutual diffusion coefficients D v,a (volume-fixed reference frame) were measured for fixed average concentrations C=(0.02989 ± 0.00001) mol·dm –3 of Na 2 SO 4 (aq) at 298.15 K while varying ΔC/C from 0.66673 to 2, a threefold variation. The dependence of the diffusion coefficient on ΔC/C was found to be linear, yielding D v = 1.041 6 × 10 –9 m 2 ·s –1 for an infinitely small concentration difference between the diffusing solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of the associated production of a W boson and a charm quark in proton–proton collisions at $\sqrt{s}$ = $\mathrm{8 TeV}$

Measurements of the associated production of a W boson and a charm (c) quark in proton–proton collisions at a centre-of-mass energy of 8TeV are reported. The analysis uses a data sample corresponding to a total integrated luminosity of 19.7 fb -1 collected by the CMS detector at the LHC. The W bosons are identified through their leptonic decays to an electron or a muon, and a neutrino. Charm quark jets are selected using distinctive signatures of charm hadron decays. The product of the cross section and branching fraction σ(pp → W + c + X)β(W →ℓv), where ℓ = e or μ, and the cross section ratio σ(pp → W + + $\bar{c}$ + X)/σ(pp → W - + c + X) are measured in a fiducial volume and differentially as functions of the pseudorapidity and of the transverse momentum of the lepton from the W boson decay. The results are compared with theoretical predictions. The impact of these measurements on the determination of the strange quark distribution is assessed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure-Driven Sequential Lattice Collapse and Magnetic Collapse in Transition-Metal-Intercalated Compounds Fe x NbS 2

Volume collapse under high pressure is an intriguing phenomenon involving subtle interplay between lattice, spin, and charge. The two most important causes of volume collapse are lattice collapse (low-density to high-density) and magnetic collapse (high-spin to low-spin). Herein we report the pressure-driven sequential volume collapses in partially intercalated Fe x NbS 2 (x = 1/4, 1/3, 1/2, 2/3). Because of the distinct interlayer atomic occupancy, the low-iron-content samples exhibit both lattice and magnetic collapses under compression, whereas the high-iron-content samples exhibit only one magnetic collapse. Therefore, theoretical calculations indicate that the low-pressure volume collapses for x = 1/4 and x = 1/3 are lattice collapses, and the high-pressure volume collapses for all four samples are magnetic collapses. The magnetic collapse involving the high-spin to low-spin crossover of Fe2+ has also been verified by in situ X-ray emission measurements. Integrating two distinct volume collapses into one material provides a rare playground of lattice, spin, and charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sister Rod Destructive Examinations (FY23) Appendix C: Rod Internal Pressure, Void Volume, and Gas Transmission Tests

As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWD/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called the sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Both fuel rods and empty cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the postirradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and consolidation activities. This appendix documents the status of the ORNL Phase 1 DE activities related to rod internal pressure and void volume measurement techniques, fission gas stack flow measurements applied to selected sister rods, and fission gas release calculations in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY22) Appendix C: Rod Internal Pressure, Void Volume, and Gas Transmission Tests

As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWD/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy [C-1]. The SNF rods, called the sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Both fuel rods and empty cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the postirradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and consolidation activities. This appendix documents the status of the ORNL Phase 1 DE activities [C-2, C-3] related to rod internal pressure and void volume measurement techniques, fission gas stack flow measurements applied to selected sister rods, and fission gas release calculations in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of WH and ZH production in the $$H \rightarrow b\bar{b}$$ decay channel in pp collisions at $$13\,\text {Te}\text {V}$$ with the ATLAS detector

Measurements of the Standard Model Higgs boson decaying into a $$b\bar{b}$$ b b ¯ pair and produced in association with a W or Z boson decaying into leptons, using proton–proton collision data collected between 2015 and 2018 by the ATLAS detector, are presented. The measurements use collisions produced by the Large Hadron Collider at a centre-of-mass energy of $$\sqrt{s} = 13\,\text {Te}\text {V}$$ s = 13 Te , corresponding to an integrated luminosity of $$139\,\mathrm {fb}^{-1}$$ 139 fb - 1 . The production of a Higgs boson in association with a W or Z boson is established with observed (expected) significances of 4.0 (4.1) and 5.3 (5.1) standard deviations, respectively. Cross-sections of associated production of a Higgs boson decaying into bottom quark pairs with an electroweak gauge boson, W or Z , decaying into leptons are measured as a function of the gauge boson transverse momentum in kinematic fiducial volumes. The cross-section measurements are all consistent with the Standard Model expectations, and the total uncertainties vary from 30% in the high gauge boson transverse momentum regions to 85% in the low regions. Limits are subsequently set on the parameters of an effective Lagrangian sensitive to modifications of the WH and ZH processes as well as the Higgs boson decay into $$b\bar{b}$$ b b ¯ .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of property covariance on cluster weak lensing scaling relations

ABSTRACT We present an investigation into a hitherto unexplored systematic that affects the accuracy of galaxy cluster mass estimates with weak gravitational lensing. Specifically, we study the covariance between the weak lensing signal, ΔΣ, and the ‘true’ cluster galaxy number count, Ngal, as measured within a spherical volume that is void of projection effects. By quantifying the impact of this covariance on mass calibration, this work reveals a significant source of systematic uncertainty. Using the MDPL2 simulation with galaxies traced by the SAGE semi-analytic model, we measure the intrinsic property covariance between these observables within the three-dimensional vicinity of the cluster, spanning a range of dynamical mass and redshift values relevant for optical cluster surveys. Our results reveal a negative covariance at small radial scales (R ≲ R200c) and a null covariance at large scales (R ≳ R200c) across most mass and redshift bins. We also find that this covariance results in a $2{\!-\!}3~{{\ \rm per\ cent}}$ bias in the halo mass estimates in most bins. Furthermore, by modelling Ngal and ΔΣ as multi-(log)-linear equations of secondary halo properties, we provide a quantitative explanation for the physical origin of the negative covariance at small scales. Specifically, we demonstrate that the Ngal–ΔΣ covariance can be explained by the secondary properties of haloes that probe their formation history. We attribute the difference between our results and the positive bias seen in other works with (mock)-cluster finders to projection effects. These findings highlight the importance of accounting for the covariance between observables in cluster mass estimation, which is crucial for obtaining accurate constraints on cosmological parameters.

Astronomy & Astrophysics↗

National Ignition Campaign Data Analysis by an ICF Outsider

A simple DT burn model, with no alpha-particle warming feedback, using a combination of ICF inputs and the measured ion temperature, T, volume compression, C, ablator velocity, v, and burn width time, Δt, can reproduce the national-ignition campaign (NIC) fusion yields with a rms percent difference of ~40%. Analysis suggestion the fusion-yield reproducibility of NIC events with nominally identically measured T, C, v, and Δt is <30%. The highest fusion yields, at a fixed laser energy are obtained with depleted-uranium (DU) hohlraums and high-density carbon (HDC) ablators. Small diameter fit tubes (≤5 μm) enhance fusion yields by an average of 26±15% relative to 10-μm diameter fit tubes. A dependence of fusion yield on the diameter of the capsule relative to the diameter of the hohlraum is inferred for fixed T, C, v, and Δt. No evidence of conditions close to ignition, or alpha-particle warming is found in the existing NIC data with LEH< 2MJ. To obtain a predictive model for extrapolation proposes we map the T, C, and v into power laws as a function of LEH. The above mentioned extrapolatable model has a rms percent difference from the yields of the second half of the NIC of (56 ± 4)%. Higher (and significantly lower) DT temperatures are obtained with HDC ablators (and low-foot drives). The highest compressions are obtained via low-foot drives, but this does not compensate for the corresponding lower temperatures. An extrapolation of the presented model suggests significant alpha-particle heating at an LEH of ~5 MJ. It is hoped that others more familiar it the conditions needed for ignition will use to presented model to estimate the LEH required for ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: H-Area Diversion Box 1 (HDB-1) Sump Sample: January 25, 2022 Sample

Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma, total alpha activities, density, free hydroxide, and pH measurements. This report presents characterization results for the H-Area diversion box 1 sump (HDB-1) January 2022 sample. The sample was slightly brown with a small amount of suspended fine particulates visually estimated to be less than 1% by volume. The results are measurements for total gamma, total alpha, total beta, density, free hydroxide, and pH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗

Electron spin resonance spectroscopy with femtoliter detection volume

We report electron spin resonance measurements of donors in silicon at millikelvin temperatures using a superconducting LC planar micro-resonator and a Josephson parametric amplifier. The resonator includes a nanowire inductor, defining a femtoliter detection volume. Due to strain in the substrate, the donor resonance lines are heavily broadened. In this work, single-spin to photon coupling strengths up to ~ 3 kHz are observed. The single shot sensitivity is 120 ± 24 spins/Hahn echo, corresponding to ≈ 12 ± 3 spins / Hz for repeated acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Effect of Sample Thickness on the Tensile Strength of Small Graphite Discs

This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.

36 MATERIALS SCIENCE↗