Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Visible/Infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

AVIRIS scan drive design and performance

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) images the ground with an instantaneous field of view (IFOV) of 1 mrad. The IFOV is scanned 30 deg from left to right to provide the cross-track dimension of the image, while the aircraft's motion provides the along-track dimension. The scanning frequency is 12 Hz, with a scan efficiency of 70 percent. The scan mirror has an effective diameter of 5.7 in, and its positional accuracy is a small fraction of a milliradian of the nominal position-time profile. Described are the design and performance of the scan drive mechanism. Tradeoffs among various approaches are discussed, and the reasons given for the selection of the cam drive.

Miller, D. C.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS ground data-processing system

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been under development at JPL for the past four years. During this time, a dedicated ground data-processing system has been designed and implemented to store and process the large amounts of data expected. This paper reviews the objectives of this ground data-processing system and describes the hardware. An outline of the data flow through the system is given, and the software and incorporated algorithms developed specifically for the systematic processing of AVIRIS data are described.

Reimer, John H.↗

The Shuttle Imaging Spectrometer Experiment (SISEX)

The concept of the imaging spectrometer is becoming established as a major new thrust in remote sensing of the earth. For several years, JPL has operated the airborne imaging spectrometer on a NASA C-130; this instrument has demonstrated the direct identification of surface materials using imaging spectrometry. An advanced aircraft instrument, the airborne visible/infrared imaging spectrometer (AVIRIS), began operation on a NASA U-2 in 1987. The Shuttle Imaging Spectrometer Experiment (SISEX) was conceived as the next step in the sequence, and would provide a relatively inexpensive demonstration of the concept in earth orbit. This paper describes the design and development status of SISEX and the status of the enabling technology.

Herring, Mark↗

Calibration Of Airborne Visible/IR Imaging Spectrometer

Paper describes laboratory spectral and radiometric calibration of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) applied to all AVIRIS science data collected in 1987. Describes instrumentation and procedures used and demonstrates that calibration accuracy achieved exceeds design requirements. Developed for use in remote-sensing studies in such disciplines as botany, geology, hydrology, and oceanography.

Vane, G. A.↗

Preliminary Analysis Of Data From AVIRIS

Report presents preliminary analysis of performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), a scanning instrument producing images at wavelengths from 400 to 2,450 nm. Includes four spectrometers connected by optical fibers to common set of foreoptics. Focuses upon calibration of instrument and determination of reflectance of surface of Earth from its measurements.

Conel, James E.↗

Evaluation of the airborne visible-infrared imaging spectrometer for mapping subtle lithological variation

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), flown aboard the NASA ER-2 aircraft in 1987 and 1989, used four linear arrays and four individual spectrometers to collect data simultaneously from the 224 bands in a scanned 614 pixel-wide swath perpendicular to the aircraft direction. The research had two goals. One was to evaluate the AVIRIS data. The other was to look at the subtle lithological variation at the two test sites to develop a better understanding of the regional geology and surficial processes. The geometric characteristics of the data, adequacy of the spatial resolution, and adequacy of the spectral sampling interval are evaluated. Geologic differences at the test sites were mapped. They included lithological variation caused by primary sedimentary layering, facies variation, and weathering; and subtle mineralogical differences caused by hydrothermal alterations of igneous and sedimentary rocks. The investigation used laboratory, field, and aircraft spectral measurements; known properties of geological materials; digital image processing and spectrum processing techniques; and field geologic data to evaluate the selected characteristics of the AVIRIS data.

Kruse, Fred A.↗

Estimation of signal-to-noise - A new procedure applied to AVIRIS data

To make the best use of narrowband airborne visible/infrared imaging spectrometer (AVIRIS) data, an investigator needs to know the ratio of signal to random variability or noise (signal-to-noise ratio or SNR). The signal is land cover dependent and varies with both wavelength and atmospheric absorption; random noise comprises sensor noise and intrapixel variability (i.e., variability within a pixel). The three existing methods for estimating the SNR are inadequate, since typical laboratory methods inflate while dark current and image methods deflate the SNR. A new procedure is proposed called the geostatistical method. It is based on the removal of periodic noise by notch filtering in the frequency domain and the isolation of sensor noise and intrapixel variability using the semi-variogram. This procedure was applied easily and successfully to five sets of AVIRIS data from the 1987 flying season and could be applied to remotely sensed data from broadband sensors.

Curran, Paul J.↗

Estimating The SNR Of AVIRIS Data

Combination of established statistical and filtering techniques yields improved estimates of signal-to-noise ratio (SNR) of multispectral imagery produced by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). Method yields more accurate estimate of random variability in AVIRIS imagery. Combination of techniques called "geostatistical" method. In first step of method, periodic noise removed by notch filtering in frequency domain. In subsequent steps, sensor noise and variability within picture elements isolated by use of semi-variance of picture elements.

Curran, Paul J.↗

Imaging spectroscopy of the terrestrial environment; Proceedings of the Meeting, Orlando, FL, Apr. 16, 17, 1990

Topics presented include the evolution of the Airborne Visible/Infrared Imaging Spectrometer flight and ground data processing system, direct mineral identification with Geoscan Mk II Advanced Multispectral Scanner, a new approach to imaging spectroscopy, and a linear-wedge spectrometer. Also presented are the effects of moisture content and chemical composition on the near-infrared spectra of forest foliage, change detection in vegetation using 1989 AVIRIS data, and the inversion of high-spectral-resolution data.

Vane, Gregg↗

Radiative transfer based retrieval of reflectance from calibrated radiance imagery measured by an imaging spectrometer for lithological mapping of the Clark Mountains, California

Spectral radiance imagery measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are reduced to reflectance through compensation for atmospheric scattering, water vapor absorption, absorption of the well mixed gases, solar irradiance and the solar zenith angle. The LOWTRAN 7 (Kneizys et al., 1989) radiative transfer code form the basis for this retrieal. LOWTRAN 7 is constrained with water vapor determinations from the AVIRIS radiance data through an algorithm operating on the 940 nm atmospheric water band for every spatial element. In situ measurements of atmospheric optical depths are used to constrain the LOWTRAN 7 aerosol models. Accuracy of the retrieved reflectance spectra is evaluated with respect to surface spectra measured at the time of the overflight. The mineral bastnaesite is identified in the analysis of the retrieved reflectance imagery. These reflectance data provide a means to map the subtle mineral gradients in the PreCambrian block of the Clark Mountain range in southeastern California for geological analysis.

Green, Robert O.↗

AVIRIS Spectrometer Maps Total Water Vapor Column

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) processes maps of vertical-column abundances of water vapor in atmosphere with good precision and spatial resolution. Maps provide information for meteorology, climatology, and agriculture.

Conel, James E.↗

Spectral reflectance of thin snow

A radiative transfer model was used to calculate the spectral reflectance of thin snow overlying dark soil. Model results show that directional hemispherical reflectance depends on density, grain size, and solar and viewing geometries. Measurements of thin snow spectral Bidirectional Reflectance Distribution Function (BRDF) show that the reflectance in the visible wavelengths is reduced when the sensor is near nadir yet, at a viewing zenith of 75 degrees the same snowpack will appear to be optically thick. If the snow is sufficiently thin and snow grains are large, the spectral signature of the substrate may influence snow reflectance. This phenomenon was also detected in reflectance data collected using the ground based PIDAS (Portable Instantaneous Display and Analysis Spectrometer). Concurrent airborne data from the AVIRIS instrument (Advanced Visible/Infrared Imaging Spectrometer) show effects of thin snow and mixed pixels for areas of thin and patchy spring snow.

Nolin, Anne W.↗

Integration of visible-through microwave-range multispectral image data sets for geologic mapping

Multispectral remote sensing data sets collected during the Geologic Remote Sensing Field Experiment (GRSFE) conducted during 1989 in the southwestern U.S. were used to produce thematic image maps showing details of the surface geology. LANDSAT TM (Thematic Mapper) images were used to map the distribution of clays, carbonates, and iron oxides. AVIRIS (Airborne Visible/Infrared Imaging Spectrometer) data were used to identify and map calcite, dolomite, sericite, hematite, and geothite, including mixtures. TIMS (Thermal Infrared Multispectral Scanner) data were used to map the distribution of igneous rock phases and carbonates based on their silica contents. AIRSAR (Airborne Synthetic Aperture Radar) data were used to map surface textures related to the scale of surface roughness. The AIRSAR also allowed identification of previously unmapped fault segments and structural control of lithology and minerology. Because all of the above data sets were geographically referenced, combination of different data types and direct comparison of the results with conventional field and laboratory data sets allowed improved geologic mapping of the test site.

Kruse, Fred A.↗

Io's radar properties

Arecibo 13 cm wavelength radar observations during 1987-90 have yielded echoes from Io on each of 11 dates. Whereas Voyager imaged parts of the satellite at resolutions of several km and various visible/infrared measurements have probed the surfaces's microscale properties, the radar data yield new information about the nature of the surface at cm to km scales. Our observations provide fairly thorough coverage and reveal significant heterogeneity in Io's radar properties. A figure is given showing sums of echo spectra from 11 dates.

Ostro, Steven J.↗

Geologic mapping in Death Valley, California/Nevada using NASA/JPL airborne systems (AVIRIS, TIMS, and AIRSAR)

A multi-sensor aircraft campaign called the Geologic Remote Sensing Field Experiment (GRSFE) conducted during 1989 resulted in acquisition of high quality multispectral images in the visible, near infrared, shortwave infrared, thermal infrared, and microwave regions of the electromagnetic spectrum. The airborne data sets include the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), the Thermal Infrared Multispectral Scanner (TIMS), and the Airborne Synthetic Aperture Radar (SAR). Ancillary data include Landsat Thematic Mapper, laboratory and field spectral measurements, and traditional geologic mapping. The GRSFE data for a site in the northern Death Valley, (California and Nevada) region were calibrated to physical units and geometrically registered to a map base. Various aspects of this experiment are briefly discussed.

Kruse, Fred A.↗

Approaches to vegetation mapping and ecophysiological hypothesis testing using combined information from TIMS, AVIRIS, and AIRSAR

The Tropical Rainforest Ecology Experiment (TREE) had two primary objectives: (1) to design a method for mapping vegetation in tropical regions using remote sensing and determine whether the result improves on available vegetation maps; and (2) to test a specific hypothesis on plant/water relations. Both objectives were thought achievable with the combined information from the Thermal Infrared Multispectral Scanner (TIMS), Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and Airborne Synthetic Aperture Radar (AIRSAR). Implicitly, two additional objectives were: (1) to ascertain that the range within each variable potentially measurable with the three instruments is large enough in the site, relative to the sensitivity of the instruments, so that differences between ecological groups may be detectable; and (2) to determine the ability of the three systems to quantify different variables and sensitivities. We found that the ranges in values of foliar nitrogen concentration, water availability, stand structure and species composition, and plant/water relations were large, even within the upland broadleaf vegetation type. The range was larger when other vegetation types were considered. Unfortunately, cloud cover and navigation errors compromised the utility of the TIMS and AVIRIS data. Nevertheless, the AIRSAR data alone appear to have improved on the available vegetation map for the study area. An example from an area converted to a farm is given to demonstrate how the combined information from AIRSAR, TIMS, and AVIRIS can uniquely identify distinct classes of land use. The example alludes to the potential utility of the three instruments for identifying vegetation at an ecological scale finer than vegetation types.

Oren, R.↗

An evaluation of techniques for the extraction of mineral absorption features from high spectral resolution remote sensing data

Airborne Visible/Infrared Imaging Spectrometer data covering the wavelength range between 2000 and 2400 nm are examined for their ability to display the diagnostic mineral absorption features of certain alteration minerals, employing various data processing techniques. The techniques may be separated into two broad categories: scene based techniques that use parameters derived from the data themselves, and correction techniques utilizing external information such as solar/atmospheric models. Results indicate that the data corrected utilizing the LOWTRAN 7 atmospheric transfer code constrained with local weather station data are the most effective at showing the diagnostic absorption features of the regions of known mineralogy and introduce the least number of artifacts into the data.

Rast, Michael↗