Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

GPU-based Scalable Volumetric Reconstruction for Multi-view Stereo

We present a new scalable volumetric reconstruction algorithm for multi-view stereo using a graphics processing unit (GPU). It is an effectively parallelized GPU algorithm that simultaneously uses a large number of GPU threads, each of which performs voxel carving, in order to integrate depth maps with images from multiple views. Each depth map, triangulated from pair-wise semi-dense correspondences, represents a view-dependent surface of the scene. This algorithm also provides scalability for large-scale scene reconstruction in a high resolution voxel grid by utilizing streaming and parallel computation. The output is a photo-realistic 3D scene model in a volumetric or point-based representation. We demonstrate the effectiveness and the speed of our algorithm with a synthetic scene and real urban/outdoor scenes. Our method can also be integrated with existing multi-view stereo algorithms such as PMVS2 to fill holes or gaps in textureless regions.

97 MATHEMATICS AND COMPUTING↗

Adjusting solar-induced fluorescence to nadir-viewing provides a better proxy for GPP

Solar-induced fluorescence (SIF) provides key information for inferring terrestrial gross primary productivity (GPP). However, there is little research on analyzing the performance of nadir-adjusted SIF (SIF nadir ) on GPP, compared to total SIF emitted by all leaves (SIF total ) for reducing the viewing angle effects and estimating GPP. Besides, there have been controversial opinions on whether SIF total is better correlated to GPP than raw SIF observations (SIF obs ). Here we systematically analyzed the relationship between raw/nadir/total SIF (i.e., SIF obs , SIF nadir and SIF total ) and GPP and investigated the underlying mechanism, using multi-angular field measurements and eddy covariance data in wheat and corn crops at sub-daily scale. We further compared the performance of SIF obs , SIF nadir and SIF total in estimating GPP using the TROPOspheric Monitoring Instrument (TROPOMI) SIF and concurrent AmeriFlux measurements at daily scale. Furthermore, the results indicate that diurnal SIF nadir has stronger correlations to GPP than SIF obs for field measurements, with the increase of mean coefficient of determination (R 2 ) by 0.05–0.07 for far-red band and 0.11–0.20 for red band. SIF nadir shows comparable performance with SIF total for both far-red and red bands. Although the viewing angle effects dominate the difference in estimating GPP between SIF nadir and SIF obs , the correlation between light use efficiency (LUE) and fesc further determines the different performance of SIF nadir and SIF total in estimating GPP. TROPOMI-based analysis further confirms that SIF nadir overall has higher correlations to AmeriFlux GPP than SIF obs for different plant functional types and shows similar performance with SIF total . Compared to SIF total , the estimation of SIF nadir independent of viewing angle effects does not require any canopy structure parameters, and thus offers promising potential for reliably estimating regional and global GPP.

54 ENVIRONMENTAL SCIENCES↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Linear-array ultrasonic waveguide transducer for under sodium viewing.

In this report, we first present the basic design of a low-noise waveguide and its performance followed by a review of the array transducer technology. The report then presents the concept and basic designs of arrayed waveguide transducers that can apply to under-sodium viewing for in-service inspection of fast reactors. Depending on applications, the basic waveguide arrays consist of designs for sideway and downward viewing. For each viewing application, two array geometries, linear and circular, are included in design analysis. Methods to scan a 2-D target using a linear array waveguide transducer are discussed. Future plan to develop a laboratory array waveguide prototype is also presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

xray↗

Exploring experts' views and perspectives on the enhancement of Strategic Environmental Assessment in European small islands

Small islands have the attention of the international community because they are territories with unique features, and a pressing need for the enhancement of sustainability. Strategic Environmental Assessment (SEA) has characteristics that may promote the development and improvement of sustainability in these territories: (i) changing the mind-set, and the decision-making and institutional paradigm, (ii) facilitating cooperation and coordination between different stakeholders, and (iii) providing a framework for good governance and community empowerment. The scientific literature suggests that there may be a need for context-specific SEA in these territories. However, SEA studies often do not incorporate local contextual information, including intuitive knowledge and sense of place. Therefore, there is a possible gap between what is found in the literature and what local communities think, including different stakeholders and experts. Hence, the main goal of this research was to gain an insight into the views and perspectives of small islands SEA experts about issues related to SEA in European small islands, including context-specific approaches, as well as the contribution of SEA for sustainability in these territories. To achieve the research aim, exploratory research using a questionnaire-based survey was designed, aimed at experts on SEA in European small islands. Findings showed regional cooperation networks may have a fundamental role when developing SEA-specific approaches in these territories. This is because SEA-specific approaches encourage a joint effort among islands within one region to improve SEA capacity-building, develop and share a baseline information system, and to share and exchange resources, overall. Also, guidelines are preferred among experts over more legal frameworks and regulations. Finally, the research showed that experts view SEA as a way to enhance sustainability in small islands. This study highlights the importance of integrating stakeholders, such as territorial experts, to learn and promote the use and improvement of environmental and sustainability tools such as SEA. - Highlights: • Explored the views and perspectives of European small island experts • Showed the need for cooperation networks while developing SEA in these territories • Encouraged the development of specific guidelines as opposed to more legal frameworks • Highlighted SEA capability for the enhancement of small island sustainability.

54 ENVIRONMENTAL SCIENCES↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Characterization of cross-section correction to charge exchange recombination spectroscopy rotation measurements using co- and counter-neutral-beam views

Measurements of rotation using charge exchange recombination spectroscopy can be affected by the energy dependence of the charge exchange cross section. On DIII-D, the associated correction to the rotation can exceed 100 km/s at high temperatures. In reactor-relevant low rotation conditions, the correction can be several times larger than the actual plasma rotation and therefore must be carefully validated. New chords have been added to the DIII-D CER diagnostic to view the counter-neutral-beam line. The addition of these views allows determination of the toroidal rotation without depending on detailed atomic physics calculations, while also allowing experimental characterization of the atomic physics. A database of rotation comparisons from the two views shows that the calculated cross-section correction can adequately describe the measurements, although there is a tendency for 'overcorrection'. In cases where accuracy better than about 15% is desired, relying on calculation of the cross-section correction may be insufficient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A tangentially viewing fast ion D-alpha diagnostic for NSTX

A second fast ion D-alpha (FIDA) installation is planned at NSTX to complement the present perpendicular viewing FIDA diagnostics. Following the present diagnostic scheme, the new diagnostic will consist of two instruments: a spectroscopic diagnostic that measures fast ion spectra and profiles at 16 radial points with 5-10 ms resolution and a system that uses a band pass filter and photomultiplier to measure changes in FIDA light with 50 kHz sampling rate. The new pair of FIDA instruments will view the heating beams tangentially. The viewing geometry minimizes spectral contamination by beam emission or edge sources of background emission. The improved velocity-space resolution will provide detailed information about neutral-beam current drive and about fast ion acceleration and transport by injected radio frequency waves and plasma instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of viewing angle on the spectral behavior of a Gd plasma source near 6.7 nm

We have demonstrated the effect of viewing angle on the extreme ultraviolet (EUV) emission spectra of gadolinium (Gd) near 6.7 nm. The spectra are shown to have a strong dependence on viewing angle when produced with a laser pulse duration of 10 ns, which may be attributed to absorption by low ion stages of Gd and an angular variation in the ion distribution. Absorption effects are less pronounced at a 150-ps pulse duration due to reduced opacity resulting from plasma expansion. Thus for evaluating source intensity, it is necessary to allow for variation with both viewing angle and target orientation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiple-view spectrally resolved x-ray imaging observations of polar-direct-drive implosions on OMEGA

We present spatially, temporally, and spectrally resolved narrow- and broad-band x-ray images of polar-direct-drive (PDD) implosions on OMEGA. These self-emission images were obtained during the deceleration phase and bang time using several multiple monochromatic x-ray imaging instruments fielded along two or three quasi-orthogonal lines-of-sight, including equatorial and polar views. The instruments recorded images based on K-shell lines from a titanium tracer located in the shell as well as continuum emission. These observations constitute the first such data obtained for PDD implosions. The image data show features attributed to laser imprinting and zero-order hydrodynamics. Equatorial-view images show a “double bun” structure that is consistent with synthetic images obtained from post-processing 2D and 3D radiation-hydrodynamic simulations of the experiment. Polar-view images show a pentagonal, petal pattern that correlates with the PDD laser illumination used on OMEGA, thus revealing a 3D aspect of PDD OMEGA implosions not previously observed. Differences are noted with respect to a PDD experiment performed at National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEBULAR PHASE OBSERVATIONS OF THE TYPE Ib SUPERNOVA 2008D/X-RAY TRANSIENT 080109: SIDE-VIEWED BIPOLAR EXPLOSION

We present optical spectroscopic and photometric observations of supernova (SN) 2008D, associated with the luminous X-ray transient 080109, at >300 days after the explosion (nebular phases). We also give flux measurements of emission lines from the H II region at the site of the SN, and estimates of the local metallicity. The brightness of the SN at nebular phases is consistent with the prediction of the explosion models with an ejected {sup 56}Ni mass of 0.07 M{sub sun}, which explains the light curve at early phases. The [O I] line in the nebular spectrum shows a double-peaked profile while the [Ca II] line does not. The double-peaked [O I] profile strongly indicates that SN 2008D is an aspherical explosion. The profile can be explained by a torus-like distribution of oxygen viewed from near the plane of the torus. We suggest that SN 2008D is a side-viewed, bipolar explosion with a viewing angle of >50 deg. from the polar direction.

99 GENERAL AND MISCELLANEOUS↗

THE VIEWING ANGLES OF BROAD ABSORPTION LINE VERSUS UNABSORBED QUASARS

It was recently shown that there is a significant difference in the radio spectral index distributions of broad absorption line (BAL) quasars and unabsorbed quasars, with an overabundance of BAL quasars with steeper radio spectra. This result suggests that source orientation does play into the presence or absence of BAL features. In this paper, we provide more quantitative analysis of this result based on Monte Carlo simulations. While the relationship between viewing angle and spectral index does indeed contain a lot of scatter, the spectral index distributions are different enough to overcome that intrinsic variation. Utilizing two different models of the relationship between spectral index and viewing angle, the simulations indicate that the difference in spectral index distributions can be explained by allowing BAL quasar viewing angles to extend about 10 Degree-Sign farther from the radio jet axis than non-BAL sources, though both can be seen at small angles. These results show that orientation cannot be the only factor determining whether BAL features are present, but it does play a role.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Field of View and Visual Complexity on Virtual Reality Training Effectiveness for a Visual Scanning Task

Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highest level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.

97 MATHEMATICS AND COMPUTING↗

Computerized image analysis: Texture-field orientation method for pectoral muscle identification on MLO-view mammograms

Purpose: To develop a new texture-field orientation (TFO) method that combines a priori knowledge, local and global information for the automated identification of pectoral muscle on mammograms. Methods: The authors designed a gradient-based directional kernel (GDK) filter to enhance the linear texture structures, and a gradient-based texture analysis to extract a texture orientation image that represented the dominant texture orientation at each pixel. The texture orientation image was enhanced by a second GDK filter for ridge point extraction. The extracted ridge points were validated and the ridges that were less likely to lie on the pectoral boundary were removed automatically. A shortest-path finding method was used to generate a probability image that represented the likelihood that each remaining ridge point lay on the true pectoral boundary. Finally, the pectoral boundary was tracked by searching for the ridge points with the highest probability lying on the pectoral boundary. A data set of 130 MLO-view digitized film mammograms (DFMs) from 65 patients was used to train the TFO algorithm. An independent data set of 637 MLO-view DFMs from 562 patients was used to evaluate its performance. Another independent data set of 92 MLO-view full field digital mammograms (FFDMs) from 92 patients was used to assess the adaptability of the TFO algorithm to FFDMs. The pectoral boundary detection accuracy of the TFO method was quantified by comparison with an experienced radiologist's manually drawn pectoral boundary using three performance metrics: The percent overlap area (POA), the Hausdorff distance (Hdist), and the average distance (AvgDist). Results: The mean and standard deviation of POA, Hdist, and AvgDist were 95.0{+-}3.6%, 3.45{+-}2.16 mm, and 1.12{+-}0.82 mm, respectively. For the POA measure, 91.5%, 97.3%, and 98.9% of the computer detected pectoral muscles had POA larger than 90%, 85%, and 80%, respectively. For the distance measures, 85.4% and 98.0% of the computer detected pectoral boundaries had Hdist within 5 and 10 mm, respectively, and 99.4% of computer detected pectoral muscle boundaries had AvgDist within 5 mm from the radiologist's manually drawn boundaries. Conclusions: The pectoral muscle on DFMs can be detected accurately by the automated TFO method. The preliminary study of applying the same pectoral muscle identification algorithm to FFDMs without retraining demonstrates that the TFO method is reasonably robust against the differences in the image properties between the digitized and digital mammograms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Few-view cone-beam CT reconstruction with deformed prior image

Purpose: Prior images can be incorporated into the image reconstruction process to improve the quality of subsequent cone-beam CT (CBCT) images from sparse-view or low-dose projections. The purpose of this work is to develop a deformed prior image-based reconstruction (DPIR) strategy to mitigate the deformation between the prior image and the target image. Methods: The deformed prior image is obtained by a projection-based registration approach. Specifically, the deformation vector fields used to deform the prior image are estimated through iteratively matching the forward projection of the deformed prior image and the measured on-treatment projections. The deformed prior image is then used as the prior image in the standard prior image constrained compressed sensing (PICCS) algorithm. A simulation study on an XCAT phantom and a clinical study on a head-and-neck cancer patient were conducted to evaluate the performance of the proposed DPIR strategy. Results: The deformed prior image matches the geometry of the on-treatment CBCT more closely as compared to the original prior image. Consequently, the performance of the DPIR strategy from few-view projections is improved in comparison to the standard PICCS algorithm, based on both visual inspection and quantitative measures. In the XCAT phantom study using 20 projections, the average root mean squared error is reduced from 14% in PICCS to 10% in DPIR, and the average universal quality index increases from 0.88 in PICCS to 0.92 in DPIR. Conclusions: The present DPIR approach provides a practical solution to the mismatch problem between the prior image and target image, which improves the performance of the original PICCS algorithm for CBCT reconstruction from few-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it is implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.

60 APPLIED LIFE SCIENCES↗