Experimental Distribution Circuit Voltage Regulation using DER Power Factor Volt-Var and Extremum Seeking Control Methods.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
High-resolution switched digital regulators are disclosed having fast cross corner and variable temperature response, with constrained ripple. The strength of the power transistors utilized by the regulator are adjusted to control the current delivered to the load. The regulators utilize a slow control loop in parallel with a primary fast switching loop. The slow loop uses the switching signal of the primary loop to estimate the load current and set the power transistor size accordingly.
Abstract not provided.
Abstract not provided.
The Hawaiian Electric Companies achieved a consolidated Renewable Portfolio Standard (RPS) of approximately 26% at the end of 2016. This significant RPS performance was achieved using various renewable energy sources - biomass, geothermal, solar photovoltaic (PV) systems, hydro, wind, and biofuels - and customer-sited, grid-connected technologies (primarily private rooftop solar PV systems). The Hawaiian Electric Companies are preparing grid-modernization plans for the island grids. The plans outline specific near-term actions to accelerate the achievement of Hawai'i's 100% RPS by 2045. A key element of the Companies' grid-modernization strategy is to utilize new technologies - including storage and PV systems with grid-supportive inverters - that will help to more than triple the amount of private rooftop solar PV systems. The Hawaiian Electric Companies collaborated with the Smart Inverter Technical Working Group Hawai'i (SITWG) to partner with the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to research the implementation of advanced inverter grid support functions (GSF). Together with the technical guidance from the Companies's planning engineers and stakeholder input from the SITWG members, NREL proposed a scope of work that explored different modes of voltage-regulation GSF to better understand the trade-offs of the grid benefits and curtailment impacts from the activation of selected advanced inverter grid support functions. The simulation results presented in this report examine the effectiveness in regulating voltage as well as the impact to the utility and the customers of various inverter-based grid support functions on two Hawaiian Electric distribution substations.
Voltage regulation using distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control has drawn increasing interests. This paper addresses the challenges of controlling multiple DEs to regulate voltages in distribution systems using an autonomous and adaptive control approach. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters with multiple DEs. Hence, the proposed control method is theoretically solid. Simulation results confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation or inefficiency. This method is autonomous based on local information and the other DEs input without the instructions from any control center, is widely adaptive to variable power system operational situations, and has a high tolerance to data shortage of systems parameter. Hence, it is suitable for broad utility application
Hydrogen is a promising clean and renewable source of energy. Its high energy density offers a unique and effective means to store energy. The integration of hydrogen production devices with the power grid could lead to a cleaner and more reliable grid operation at reasonable costs. In this work, the capability of Proton Exchange Membrane (PEM) electrolyzers to perform grid services is assessed using a battery equivalent model approach. The Battery Equivalent Model (BEM) has been developed to represent the physics and operation of a fleet of PEM electrolyzers. The BEM model has been designed to be modular and readily incorporated into grid planning studies. This application of PEM electrolyzers can be integrated with other power generation and consumption devices, aggregating capabilities of each device to enhance the ability of the integrated system to provide grid services and improves grid stability. The developed model is evaluated using ancillary support services including peak management, frequency regulation, voltage regulation, artificial inertia, spinning reserve, and wholesale market price response using a representative price and power system profiles. The BEM model has also been evaluated to provide frequency regulation service that conforms to the IEEE 1547-2018 standard. Metrics such as energy efficiency, charging efficiency, hydrogen production rate, and service efficacy have been incorporated into the model to quantify the performance of the fleet while responding to grid services. Results show the electrolyzer fleet's effectiveness in quickly adjusting its real power consumption based on grid service requests. The energy efficiency of the fleet is maintained relatively high – in the range of 78% and 90% during the service operation. These results demonstrate the ability of PEM electrolyzers to effectively provide fast dispatch capability through storing off-peak hour energy while regulating power consumption during peak hours. The BEM model can assist in quantifying the stability and variability impacts from integration of PEM electrolyzers with intermittent renewable resources in grid integration studies.
Improved voltage regulator designed for use in solar photovoltaic dc power system utilizing flywheel for energy storage. Includes self-oscillating inductive voltage-boosting circuit, which regulates withdrawal of energy from flywheel and motor/generator when output of solar cells insufficient to maintain load voltage at specified level of 150 Vdc. Features include optical coupling and rapid response.
A voltage regulated DC to DC converter uses an inductor and a capacitor as storage elements. The inductor is composed of two windings having a common junction. A transformer with a center tap connected to the common junction of the two windings is connected at either end of its winding to ground through controlled switches. One winding of the inductor and either end of the transformer winding are connected by power diodes to the capacitor which supplies the output voltage to a load. The other winding of the inductor is connected to a fourth power diode as a clamping diode. Input voltage is supplied to the inductor through a third controlled switch. A pulse width modulator connected to the output of the converter alternately closes and opens the switches connected to either end of the transformer winding and also closes the switch supplying input voltage to the inductor each time either of the switches connected to the ends of the transformer winding are closed. The duty cycle of the closing and opening of the several switches is adjusted by the pulse modulator to regulate the output voltage.
This paper presents a new distributed control framework to coordinate inverter-interfaced distributed energy resources (DERs) in island microgrids. We show that under bounded load uncertainties, the proposed control method can steer the microgrid to a desired steady state with synchronized inverter frequency across the network and proportional sharing of both active and reactive powers among the inverters. We also show that such convergence can be achieved while respecting constraints on voltage magnitude and branch angle differences. The controller is robust under various contingency scenarios, including loss of communication links and failures of DERs. The proposed controller is applicable to lossy mesh microgrids with heterogeneous R/X distribution lines and reasonable parameter variations. Simulations based on various microgrid operation scenarios are also provided to show the effectiveness of the proposed control method.
In this chapter, droop-free distributed control for AC microgrids is discussed. The hierarchical structure of microgrid control is first introduced. Secondary level controls both with and without droop are discussed. Then two droop-free distributed controls are presented: one achieves average voltage regulation and perfect power sharing, and the other one achieves average voltage regulation, voltage variance regulation, and relaxed reactive power sharing. For the latter droop-free control, the relaxed reactive power sharing is achieved through a special distributed generator (DG) that will not participate in reactive power sharing.
This paper presents a hardware-in-the-loop (BIL) simulation to evaluate the performance of an advanced grid automation architecture, referred to as data-enhanced hierarchical control (DEHC), in achieving voltage regulation and conservation voltage reduction (CVR) in distribution networks with very high photovoltaic (PV) generation. This architecture comprises an advanced distribution management system (ADMS), a distributed energy resource management system (DERMS), and grid-edge devices working synergistically to provide the grid benefits. The HIL setup used for the evaluation includes ADMS, DERMS, and grid-edge devices. The DEHC performance is evaluated in two representative scenarios considering loose and tight constraints of the power factor at the substation. The results show that the DEHC architecture is effective in achieving voltage regulation and CVR and thus enables the grid integration of high levels of PV generation.