Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Non-Destructive Evaluation Method and Apparatus for Measuring Acoustic Material Nonlinearity

An acoustic non-linearity parameter (beta) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members obviates the need for electronic calibration of the measuring equipment. Unlike known substitutional measuring techniques requiring elaborate calibration procedures, the electrical outputs of the capacitive detector of a sample with known beta and the test sample of unknown beta are compared to determine the unknown beta. In order to provide the necessary stability of the present-inventive reference-based approach, the bandpass filters of the measurement system are maintained in a temperature-controlled environment, and the line voltage supplied to said amplifiers is well-regulated.

William T Yost↗

A Novel Reconfigurable GaN Based Fully Solid-State Microwave Power Module for Communications/Radar Applications

In this paper, we present as a proof-of-concept (POC) the design, integration, and performance of a novel reconfigurable GaN based fully solid-state MPM. The module synergistically integrates diplexers, pre-amplifiers, multistage medium power amplifiers (MPAs), SPDT switches, and CW/Pulsed high power amplifiers (HPAs) with a voltage sequencer, a DC blanking controller, and a low voltage electronic power conditioner. The POC SSMPM operates at both S-band and X-band to serve multiple roles. The SSMPM can be reconfigured to deliver Psat of 39 dBm (8 W CW) at S-band, Psat of 46 dBm (40 W CW) at X-band, and Psat of >50 dBm (>100 W Pulsed) at X-band. Lastly, our link budget calculations indicate that the SSMPM with Psat = 40 W when coupled to a 10 cm X-band transmit antenna on a low Earth orbiting (900 km) satellite can close a 1 Gbps (QPSK) data downlink to a 1 m receive antenna on ground with 3 dB margin.

Simons, Rainee N.↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge-coupled differential amplifier

Device solves problem of differential voltage gain in sampled-data metal-oxide semiconductor, producing gain at any frequency compatible with CCD operation, with low noise, low power, good linearity, and high stability.

Hewes, C. R.↗

Ultra low-noise charge coupled device

Special purpose CCD designed for ultra low-noise imaging and spectroscopy applications that require subelectron read noise floors, wherein a non-destructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are possible in this manner. In a preferred embodiment of the invention, a three-phase CCD horizontal register is used to bring a pixel charge packet to an input gate adjacent a floating gate amplifier. The charge is then repeatedly clocked back and forth between the input gate and the floating gate. Each time the charge is injected into the potential well of the floating gate, it is sensed non-destructively. The floating gate amplifier is provided with a reference voltage of a fixed value and a pre-charge gate for resetting the amplifier between charge samples to a constant gain. After the charge is repeatedly sampled a selected number of times, it is transferred by means of output gates, back into the horizontal register, where it is clocked in a conventional manner to a diffusion MOSFET amplifier. It can then be either sampled (destructively) one more time or otherwise discarded.

Janesick, James R.↗

Performance of High Temperature Operational Amplifier, Type LM2904WH, under Extreme Temperatures

Operation of electronic parts and circuits under extreme temperatures is anticipated in NASA space exploration missions as well as terrestrial applications. Exposure of electronics to extreme temperatures and wide-range thermal swings greatly affects their performance via induced changes in the semiconductor material properties, packaging and interconnects, or due to incompatibility issues between interfaces that result from thermal expansion/contraction mismatch. Electronics that are designed to withstand operation and perform efficiently in extreme temperatures would mitigate risks for failure due to thermal stresses and, therefore, improve system reliability. In addition, they contribute to reducing system size and weight, simplifying its design, and reducing development cost through the elimination of otherwise required thermal control elements for proper ambient operation. A large DC voltage gain (100 dB) operational amplifier with a maximum junction temperature of 150 C was recently introduced by STMicroelectronics [1]. This LM2904WH chip comes in a plastic package and is designed specifically for automotive and industrial control systems. It operates from a single power supply over a wide range of voltages, and it consists of two independent, high gain, internally frequency compensated operational amplifiers. Table I shows some of the device manufacturer s specifications.

Patterson, Richard↗

Active control of flexural vibrations in beams

The feasibility of using piezoelectric actuators to control the flexural oscillations of large structures in space is investigated. Flexural oscillations are excited by impulsive loads. The vibratory response can degrade the pointing accuracy of cameras and antennae, and can cause high stresses at structural node points. Piezoelectric actuators have the advantage of exerting localized bending moments. In this way, vibration is controlled without exciting rigid body modes. The actuators are used in collocated sensor/driver pairs to form a feedback control system. The sensor produces a voltage that is proportional to the dynamic stress at the sensor location, and the driver produces a force that is proportional to the voltage applied to it. The analog control system amplifies and phase shifts the sensor signal to produce the voltage signal that is applied to the driver. The feedback control is demonstrated to increase the first mode damping in a cantilever beam by up to 100 percent, depending on the amplifier gain. The damping efficiency of the control system when the piezoelectrics are not optimally positioned at points of high stress in the beam is evaluated.

Gerhold, Carl H.↗

Gyrator employing field effect transistors

A gyrator circuit of the conventional configuration of two amplifiers in a circular loop, one producing zero phase shift and the other producing 180 deg phase reversal is examined. All active elements are MOS field effect transistors. Each amplifier comprises a differential amplifier configuration with current limiting transistor, followed by an output transistor in cascode configuration, and two load transistors of opposite conductivity type from the other transistors. A voltage divider control circuit comprises a series string of transistors with a central voltage input to provide control, with locations on the amplifiers receiving reference voltages by connection to appropriate points on the divider. The circuit produces excellent response and is well suited for fabrication by integrated circuits.

Hochmair, E. S.↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗

A new dry biomedical electrode

Electronic circuitry contains new operational amplifier which incorporates monolithic super-gain transistors. Electrode does not provide voltage amplification; instead, it acts as current amplifier to make it possible to pick up electrical potentials from surface of highly resistant dry skin.

Luce, R. S.↗

Characterization of Transducers and Resonators under High Drive Levels

In many applications, piezoelectric transducers are driven at AC voltage levels well beyond the level for which the material was nominally characterized. In this paper we describe an experimental setup that allows for the determination of the main transducer or resonator properties under large AC drive. A sinusoidal voltage from a waveform generator is amplified and applied across the transducer/resonator in series with a known high power resistor. The amplitude of applied voltage and the amplitude and the relative phase of the current through the resistor are monitored on a digital scope. The frequency of the applied signal is swept through resonance and the voltage/current signals are recorded. After corrections for the series resistance and parasitic elements the technique allows for the determination of the complex impedance spectra of the sample as a function of frequency. In addition, access to the current signal allows for the direct investigation of non-linear effects through the application of Fourier transform techniques on the current signal. Our results indicate that care is required when interpreting impedance data at high drive level due to the frequency dependence of the dissipated power. Although the transducer/resonator at a single frequency and after many cycles may reach thermal equilibrium, the spectra as a whole cannot be considered an isothermal measurement due to the temperature change with frequency. Methods to correct for this effect will be discussed. Results determined from resonators of both soft and hard PZT and a ultrasonic horn transducer are presented.

transducers↗

Correcting for Nonlinearity in a Photodetector

Simple positive-feedback circuit varies bias voltage as necessary. Ideal detector biased with constant voltage, detector current proportional to photon flux plus constant offset. Detector connected between inverting input and ground, and feedback from operational amplifier through feedback resistor Rf make voltage at inverting input equal to noninverting input. Bias voltage held constant. Principle applied to linearizing mercury cadmium telluride infrared detectors in Fourier-transform spectrometers and other spectral and imaging instruments.

Schindler, R. A.↗

Photonic-band-gap gyrotron amplifier with picosecond pulses

Here, we report the amplification of 250 GHz pulses as short as 260 ps without observation of pulse broadening using a photonic-band-gap circuit gyrotron traveling-wave-amplifier. The gyrotron amplifier operates with a device gain of 38 dB and an instantaneous bandwidth of 8 GHz. The operational bandwidth of the amplifier can be tuned over 16 GHz by adjusting the operating voltage of the electron beam and the magnetic field. The amplifier uses a 30 cm long photonic-band-gap interaction circuit to confine the desired TE 03 -like operating mode while suppressing lower order modes which can result in undesired oscillations. The circuit gain is >55 dB for a beam voltage of 23 kV and a current of 700 mA. These results demonstrate the wide bandwidths and a high gain achievable with gyrotron amplifiers. The amplification of picosecond pulses of variable lengths, 260–800 ps, shows good agreement with the theory using the coupled dispersion relation and the gain-spectrum of the amplifier as measured with quasi-CW input pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effects of feedback amplifier characteristics on constant temperature hot-wire anemometer systems

The 3rd-order analysis of Perry and Morrison (1971) was extended to 7th-order by Watmuff (1987) by including both the bridge-capacitance and the frequency-response characteristics of the feedback amplifier. In this paper, the bridge capacitance has been excluded from the analysis. The influence of the gain K, roll-off frequency f(A), and offset voltage E(qi) of the feedback amplifier are examined in more detail together with their interactions with the bridge inductance.

Watmuff, J. H.↗

Modeling a Common-Source Amplifier Using a Ferroelectric Transistor

This paper presents a mathematical model characterizing the behavior of a common-source amplifier using a FeFET. The model is based on empirical data and incorporates several variables that affect the output, including frequency, load resistance, and gate-to-source voltage. Since the common-source amplifier is the most widely used amplifier in MOS technology, understanding and modeling the behavior of the FeFET-based common-source amplifier will help in the integration of FeFETs into many circuits.

Sayyah, Rana↗

Development of a Hydrazine/Nitrogen Dioxide Fiber Optic Sensor

Bromothymol Blue (BT)/Bromocresol Green (BG) mixture (1/1) in hydrogel (l/l), produces a blue-green indicator for HZ and/or NO2. The stability over a two months period of this BT/BG (1/1) indicator solution was tested and no evidence of performance deterioration was detected. A dual HZ/NO2 prototype sensor utilizing an acid-base indicator was previously constructed. A monitor and control circuit are also designed, built d tested during the course of this project. The circuit is controlled with Motorola MC68HC II microcontroller evaluation board to monitor the voltage level out of the photodetector. Low-pass filter and amplifier are used to interface the sensor's small voltage with the microcontroller's AD input. The sensor, interface circuit and the microcontroller board are then all placed in one unit and powered with a single power supply. The unit is then tested several times and the response was consistent and proved the feasibility of dual "J@ leak detection. Other sensor types, suitable for silica glass fiber, smaller in size, more rugged and suitable for use on board of the Space Shuttle and missile canisters, are then proposed.

Andrawis, Alfred S.↗

Fermilab 2025 Summer Internship Skills Learned from Working with Mu2e Tracker Team

As part of a DOE RENEW Grant, the undergraduate authors interned at Fermilab. They spent nine weeks over summer 2025 working on the tracker team for the Mu2e experiment. They gained practical experience in a multitude of new skills including electronics installation, testing, and repairs. Their work particularly increased productivity by helping repair the high voltage and calibration pre-amplifiers, over 20,000 of which are needed in the tracker. These components are very fragile and often break during the installation process. The experience also taught them several soft skills such as the importance of thoughtful data storage, record- keeping, and problem-solving skills. They learned the demands of a large, international collaboration and how to work in a team. The authors would like to acknowledge their advisor and PI of the grant, Dr. Christopher G. Fasano, and the Mu2e team lead by co- spokesperson Dr. Bob Bernstein and tracker L2 manager Dr. Brendan Kiburg.

de Zwart, Brontë↗