Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASONOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Theoretical and experimental studies of combined therapy of tumours with application of ultrasound

The article presents novel method of combined therapy of superficial tumours based on excitation of ultrasonic waves in tumour tissues by means of ring-shaped waveguide with subsequent radiotherapy and results of its theoretical and experimental studies. Harmonic analysis of forced flexural vibration of the waveguide using ANSYS software and APDL (ANSYS Parametric Design Language) was implemented for determination of waveguide geometric parameters providing its resonance for the given excitation frequency. The developed finite element model accounts for interaction between the waveguide and tumour tissue as well as initial prestressing of tissue radially compressed by the waveguide. Resonant curves of the waveguide in terms of its thickness and diameter are calculated and presented. Experimental studies were performed in vivo on white rats with inoculated sarcoma M-1 tumours. Treatment was performed using ultrasound with frequency 22-23 kHz and intensity about 2 W/cm{sup 2}. Ultrasonic treatment was proved to be an efficient modifier of radiotherapy.

60 APPLIED LIFE SCIENCES↗

Wavelets in medical imaging

The aim of this study is to provide emerging applications of wavelet methods to medical signals and images, such as electrocardiogram, electroencephalogram, functional magnetic resonance imaging, computer tomography, X-ray and mammography. Interpretation of these signals and images are quite important. Nowadays wavelet methods have a significant impact on the science of medical imaging and the diagnosis of disease and screening protocols. Based on our initial investigations, future directions include neurosurgical planning and improved assessment of risk for individual patients, improved assessment and strategies for the treatment of chronic pain, improved seizure localization, and improved understanding of the physiology of neurological disorders. We look ahead to these and other emerging applications as the benefits of this technology become incorporated into current and future patient care. In this chapter by applying Fourier transform and wavelet transform, analysis and denoising of one of the important biomedical signals like EEG is carried out. The presence of rhythm, template matching, and correlation is discussed by various method. Energy of EEG signal is used to detect seizure in an epileptic patient. We have also performed denoising of EEG signals by SWT.

60 APPLIED LIFE SCIENCES↗

Mechanisms for microvascular damage induced by ultrasound-activated microbubbles

To provide insight into the mechanisms of microvascular damage induced by ultrasound-activated microbubbles, experimental studies were performed to correlate microvascular damage to the dynamics of bubble-vessel interactions. High-speed photomicrography was used to record single microbubbles interacting with microvessels in ex vivo tissue, under the exposure of short ultrasound pulses with a center frequency of 1 MHz and peak negative pressures (PNP) ranging from 0.8-4 MPa. Vascular damage associated with observed bubble-vessel interactions was either indicated directly by microbubble extravasation or examined by transmission electron microscopy (TEM) analyses. As observed previously, the high-speed images revealed that ultrasound-activated microbubbles could cause distention and invagination of adjacent vessel walls, and could form liquid jets in microvessels. Vessel distention, invagination, and liquid jets were associated with the damage of microvessels whose diameters were smaller than those of maximally expanded microbubbles. However, vessel invagination appeared to be the dominant mechanism for the damage of relative large microvessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histological evaluation of high-intensity focused ultrasound with lower-intensity focused ultrasound pre-exposure on the treatment of rabbit VX2 liver tumors

This study was to evaluate the effect of pre-exposure lower-intensity focused ultrasound(US), or LIFU, in high-intensity focused ultrasound(HIFU) ablation of rabbit VX2 liver tumors . Liver VX2 tumor models were established in 30 rabbits, which were divided randomly into two groups. The liver tumors of rabbits in Group A underwent single HIFU ablation; those in Group B were given LIFU exposure before HIFU treatment. Five rabbits from each of the two groups were sacrificed at 0 hours, 3 days, and 7 days after HIFU ablation. Tissue samples that included targeted and short-range sounding (s-RS, within 5 mm of the targeted) and far-range sounding (f-RS, more than 5 mm of the targeted) tissues were observed using light microscope and transmission electron microscopy. The histological examination indicated that not only the targeted tumor cells became irreversible damage, but also the short-range sounding tumors were severely damaged by the HIFU with LIFU pre-exposure in group B. It is concluded that LIFU pre-exposure can enhance the effects of HIFU ablation on the destruction of cell ultrastructures and can enlarge the region of HIFU ablation.

60 APPLIED LIFE SCIENCES↗

Rapid HIFU autofocusing using the entire MR-ARFI image

Phase aberrations and attenuations caused by bone can defocus HIFU in the brain and organs behind the ribcage. To refocus the beam, MR-ARFI can be used to measure tissue displacements created by each element in the transducer, and optimize driving signal delays and amplitudes. We introduce a new MR-ARFI-based autofocusing method that requires many fewer image acquisitions than current methods. The method is validated in simulations of bone and brain HIFU transducers, and compared to a conventional method.

60 APPLIED LIFE SCIENCES↗

Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

60 APPLIED LIFE SCIENCES↗

Embedded ultrasound sensor in a silicon-on-insulator photonic platform

A miniaturized ultrasound sensor is demonstrated in a silicon-on-insulator platform. The sensor is based on a π-phase-shifted Bragg grating formed by waveguide corrugation. Ultrasound detection is performed by monitoring shifts in the resonance frequency of the grating using pulse interferometry. The device is characterized by measuring its response to a wideband acoustic point source generated using the optoacoustic effect. Experimental results show that the sensor's response is dominated by the formation of surface acoustic waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confocal acoustic radiation force optical coherence elastography using a ring ultrasonic transducer

We designed and developed a confocal acoustic radiation force optical coherence elastography system. A ring ultrasound transducer was used to achieve reflection mode excitation and generate an oscillating acoustic radiation force in order to generate displacements within the tissue, which were detected using the phase-resolved optical coherence elastography method. Both phantom and human tissue tests indicate that this system is able to sense the stiffness difference of samples and quantitatively map the elastic property of materials. Our confocal setup promises a great potential for point by point elastic imaging in vivo and differentiation of diseased tissues from normal tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved back projection algorithm of ultrasound tomography

Binary logic back projection algorithm is improved in this work for the development of fast ultrasound tomography system with a better effect of image reconstruction. The new algorithm is characterized by an extra logical value ‘2’ and dual-threshold processing of collected raw data. To compare with the original algorithm, a numerical simulation was conducted by the verification of COMSOL simulations formerly, and then a set of ultrasonic tomography system is established to perform the experiments of one, two and three cylindrical objects. The object images are reconstructed through the inversion of signals matrix acquired by the transducer array after a preconditioning, while the corresponding spatial imaging errors can obviously indicate that the improved back projection method can achieve modified inversion effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-phase air-water stratified flow measurement using ultrasonic techniques

In this paper, a time resolved ultrasound system was developed for investigating two-phase air-water stratified flow. The hardware of the system includes a pulsed wave transducer, a pulser/receiver, and a digital oscilloscope. The time domain cross correlation method is used to calculate the velocity profile along ultrasonic beam. The system is able to provide velocities with spatial resolution of around 1mm and the temporal resolution of 200μs. Experiments were carried out on single phase water flow and two-phase air-water stratified flow. For single phase water flow, the flow rates from ultrasound system were compared with those from electromagnetic flow (EM) meter, which showed good agreement. Then, the experiments were conducted on two-phase air-water stratified flow and the results were given. Compared with liquid height measurement from conductance probe, it indicated that the measured velocities were explainable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topographically induced internal solitary waves in a pycnocline: Ultrasonic probes and stereo-correlation measurements

Internal solitary waves (ISWs) are large amplitude stable waves propagating in regions of high density gradients such as the ocean pycnocline. Their dynamics has often been investigated in two-dimensional approaches, however, their three-dimensional evolution is still poorly known. Experiments have been conducted in the large stratified water tank of CNRM-GAME to study the generation of ISWs in two academic configurations inspired by oceanic regimes. First, ultrasonic probes are used to measure the interfacial displacement in the two configurations. In the primary generation case for which the two layers are of constant density, the generation of ISWs is investigated in two series of experiments with varying amplitude and forcing frequency. In the secondary generation case for which the lower layer is stratified, the generation of ISWs from the impact of an internal wave beam on the pycnocline and their subsequent dynamics is studied. The dynamics of ISWs in these two regimes accords well with analytical approaches and numerical simulations performed in analogous configurations. Then, recent developments of a stereo correlation technique are used to describe the three-dimensional structure of propagating ISWs. In the primary generation configuration, small transverse effects are observed in the course of the ISW propagation. In the secondary generation configuration, larger transverse structures are observed in the interfacial waves dynamics. The interaction between interfacial troughs and internal waves propagating in the lower stratified layer are a possible cause for the generation of these structures. The magnitude of these transverse structures is quantified with a nondimensional parameter in the two configurations. They are twice as large in the secondary generation case as in the primary generation case.

42 ENGINEERING↗

Out-of-resonance vibration modulation of ultrasound with a nonlinear oscillator for microcrack detection in a cantilever beam

This Letter reports an out-of-resonance vibro-acoustic modulation (VAM) effect in nonlinear ultrasonic evaluation of a microcracked cantilever beam. We design a model to involve the microcracked cantilever beam in a nonlinear oscillator system whose dynamics is introduced to extend the operating vibration excitation band of the VAM out of resonance. The prototype model exhibits an effective bandwidth four times that of the traditional linear model. The reported VAM effect allows efficiently enhancing the detection, localization, and imaging of various types of microcracks in solid materials at out-of-resonance vibration excitation frequencies.

36 MATERIALS SCIENCE↗

Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear aspects of acoustic radiation force in biomedical applications

In the past decade acoustic radiation force (ARF) became a powerful tool in numerous biomedical applications. ARF from a focused ultrasound beam acts as a virtual “finger” for remote probing of internal anatomical structures and obtaining diagnostic information. This presentation deals with generation of shear waves by nonlinear focused beams. Albeit the ARF has intrinsically nonlinear origin, in most cases the primary ultrasonic wave was considered in the linear approximation. In this presentation, we consider the effects of nonlinearly distorted beams on generation of shear waves by such beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic radiation force due to arbitrary incident fields on spherical particles in soft tissue

Acoustic radiation force is of interest in a wide variety of biomedical applications ranging from tissue characterization (e.g. elastography) to tissue treatment (e.g. high intensity focused ultrasound, kidney stone fragment removal). As tissue mechanical properties are reliable indicators of tissue health, the former is the focus of the present contribution. This is accomplished through an investigation of the acoustic radiation force on a spherical scatterer embedded in tissue. Properties of both the scatterer and the surrounding tissue are important in determining the magnitude and the direction of the force. As these properties vary, the force computation shows changes in magnitude and direction, which may enable more accurate noninvasive determination of tissue properties.

42 ENGINEERING↗

Experimental study of acoustic radiation force of an ultrasound beam on absorbing and scattering objects

Acoustic radiation force is a nonlinear acoustic effect caused by the transfer of wave momentum to absorbing or scattering objects. This phenomenon is exploited in modern ultrasound metrology for measurement of the acoustic power radiated by a source and is used for both therapeutic and diagnostic sources in medical applications. To calculate radiation force an acoustic hologram can be used in conjunction with analytical expressions based on the angular spectrum of the measured field. The results of an experimental investigation of radiation forces in two different cases are presented in this paper. In one case, the radiation force of an obliquely incident ultrasound beam on a large absorber (which completely absorbs the beam) is considered. The second case concerns measurement of the radiation force on a spherical target that is small compared to the beam diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗