Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transformative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mapping the Complete Reaction Energy Landscape of a Metal–Organic Framework Phase Transformation

Crystalline materials undergo valuable phase transformations, and the energetic processes that underlie these transformations can be fully characterized through a combination of thermodynamic and kinetic studies. Here, we report the first complete reaction energy landscape of metal–organic framework (MOF) interpenetration, specifically in the phase transformation of NU-1200 to its doubly interpenetrated counterpart, STA-26. We characterized the thermodynamics of this phase transformation by pairing experiments with density functional theory (DFT) calculations. This analysis revealed that factors such as the increase in crystal density likely drive Zr- and Hf-NU-1200 to STA-26 interpenetration, while other chemical interactions such as steric repulsions prevent Th-NU-1200 from interpenetrating. Using time-resolved in situ X-ray diffraction, we monitored phase transformation reaction profiles and extracted quantitative kinetic information using the Avrami-Erofe’ev model. As a result, we obtained activation energies for the Zr- and Hf-NU-1200 transformations to Zr- and Hf-STA-26, respectively, revealing slower phase change kinetics for MOFs with stronger bonds. Finally, we paired the kinetic data with experimental observations to classify the mechanistic model of this phase transformation as partial dissolution. Here, we anticipate that this thermodynamic, kinetic, and mechanistic understanding will broadly inform further studies on the energetics of crystallization.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Size Transformation of the Au 22 (SG) 18 Nanocluster and Its Surface-Sensitive Kinetics

For many applications of well-defined gold nanoclusters, it is desirable to understand their structural evolution behavior under working conditions with molecular precision. Here we report the first systematic investigation of the size transformation products of the Au 22 (SG) 18 nanocluster under representative working conditions and highlight the surface effect on the transformation kinetics. Under thermal and aerobic conditions, the consecutive and pH-dependent transformation from Au 22 to both well-defined clusters and small Au(I)SR species was identified by ESI-MS and UV-vis spectroscopy. By introducing a perturbation onto the Au 22 surface, significant changes in the activation parameters were determined from the kinetic study of the Au 22 transformation. This indicates the sensitivity of the nanocluster transformation pathway to the cluster surface. Finally, the systematic study of cluster transformation and the sensitivity of cluster transformation to the surface revealed herein has significant implications for future attempts to design gold nanoparticles with adaptation to the working environment and the regeneration of active nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local chemical fluctuation mediated ultra-sluggish martensitic transformation in high-entropy intermetallics

Superelasticity associated with martensitic transformation has found a broad range of engineering applications, such as in low-temperature devices in the aerospace industry. Nevertheless, the narrow working temperature range and strong temperature sensitivity of the first-order phase transformation significantly hinder the usage of smart metallic components in many critical areas. Here, we scrutinized the phase transformation behavior and mechanical properties of multicomponent B2-structured intermetallic compounds. Strikingly, the (TiZrHfCuNi) 83.3 Co 16.7 high-entropy intermetallics (HEIs) show superelasticity with high critical stress over 500 MPa, high fracture strength of over 2700 MPa, and small temperature sensitivity in a wide range of temperatures over 220 K. The complex sublattice occupation in these HEIs facilitates formation of nano-scaled local chemical fluctuation and then elastic confinement, which leads to an ultra-sluggish martensitic transformation. The thermal activation of the martensitic transformation was fully suppressed while the stress activation is severely retarded with an enhanced threshold stress over a wide temperature range. Moreover, the high configurational entropy also results in a small entropy change during phase transformation, consequently giving rise to the low temperature sensitivity of the superelasticity stress. Furthermore, our findings may provide a new paradigm for the development of advanced superelastic alloys, and shed new insights into understanding of martensitic transformation in general.

36 MATERIALS SCIENCE↗

No evidence for transient transformation via pollen magnetofection in several monocot species

The development of rapid and efficient transformation methods for many plant species remains an obstacle in both the basic and applied plant sciences. A novel method described by Zhao et al. (2017) used magnetic nanoparticles to deliver DNA into pollen grains of several dicot species, and one monocot (lily), to achieve transformation (“pollen magnetofection”). Using the published protocol, extensive trials by two independent research groups showed no indication of transient transformation success with pollen from two monocots, maize and sorghum. To further address the feasibility of magnetofection, lily pollen was used for side-by-side trials of magnetofection with a proven methodology for transient transformation, biolistics. Using a Green Fluorescent Protein reporter plasmid, transformation efficiency with the biolistic approach averaged 0.7% over three trials. However, the same plasmid produced no recognizable transformants via magnetofection, despite screening >3500 individual pollen grains. We conclude that pollen magnetofection is not effective for transient transformation of pollen for at least three species of monocots, and suggest that efforts to replicate the magnetofection protocol in dicot species would be useful to fully assess its potential. ARISING FROM Zhao et al. Nature Plants https://doi.org/10.1038/s41477-017-0063-z (2017)

Vejlupkova, Zuzana↗

Theory of finite-temperature two-dimensional structural transformations in group-IV monochalcogenide monolayers

An account of two-dimensional (2D) structural transformations in 2D ferroelectrics predicts an evolution from a structure with Pnm 2 1 symmetry into a structure with square P4/nmm symmetry and is consistent with experimental evidence, while another argues for a transformation into a structure with rectangular Pnmm symmetry. An analysis of the assumptions made in these models is provided here, and six fundamental results concerning these transformations are contributed as follows: (i) Softened phonon modes produce rotational modes in these materials. (ii) The transformation to a structure with P4/nmm symmetry occurs at the lowest critical temperature T c . (iii) The hypothesis that one unidirectional optical vibrational mode underpins the 2D transformation is unwarranted. (iv) Being successively more constrained, a succession of critical temperatures ( T c < T c ' < T c " ) occurs in going from molecular dynamics calculations with the NPT and NVT ensembles onto models with unidirectional oscillations. (v) The choice of exchange-correlation functional impacts the estimate of the critical temperature. (vi) Importantly, the correct physical picture of these transformations is one in which rotational modes confer a topological character to the 2D transformation via the proliferation of vortices.

2d ferroelectrics↗

Type IV-like pili facilitate transformation in naturally competent archaea

Naturally competent organisms are capable of DNA uptake directly from the environment through the process of transformation. Despite the importance of transformation to microbial evolution, DNA uptake remains poorly characterized outside the bacterial domain. Here, we identify the pilus as a necessary component of the transformation machinery in archaea. We describe two naturally competent organisms: Methanococcus maripaludis and Methanoculleus thermophilus. In M. maripaludis, replicative vectors were transferred with an average efficiency of 2.4 x 10 3 transformants μg -1 DNA. In M. thermophilus, integrative vectors were transferred with an average efficiency of 2.7 x 10 3 transformants μg -1 DNA. Additionally, natural transformation of M. thermophilus could be used to introduce chromosomal mutations. To our knowledge, this is the first demonstration of a method to introduce targeted mutations in a member of the order Methanomicrobiales. For both organisms, mutants lacking structural components of the type IV-like pilus filament were defective for DNA uptake, demonstrating the importance of pili for natural transformation. Interestingly, competence could be induced in a non-competent strain of M. maripaludis by expressing pilin genes from a replicative vector. Furthermore, these results expand the known natural competence pili to include examples from the archaeal domain and highlight the importance of pili for DNA uptake in diverse microbial organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis and Planning Framework for Nuclear Plant Transformation

Commercial nuclear power in the United States has been an unqualified success by any measure, providing low cost, carbon-free, and safe baseload electricity for decades. The industry today is at the peak of its historical performance in terms of generation output, reliable operations, and demonstrated nuclear safety. However, it is no longer among the lowest-cost electric generation sources with the emergence of subsidized renewables and shale gas generation. The business model that has served the operating nuclear fleet so well over its life is now a drag on cost performance due to its reliance on a large highly skilled labor force. In contrast, digital technology and innovation are enabling dramatic efficiencies in energy production, resulting in fierce competition for a commodity such as electricity. The nuclear power industry has responded to this challenge with many initiatives to improve efficiency and modernize plant equipment, especially where reliability and obsolescence issues are pressing. However, it would be a missed opportunity to merely modernize the plant components and the work processes of an outdated business model that was formulated to manage the technology of the 1960s. Rather, the greater opportunity is to transform that business model to one that fully exploits the capabilities of modern digital technology, resulting in substantially lower production costs and sustainable market viability. One successful example of such transformation is the concept of Integrated Operations, which was introduced into the North Sea oil and gas industry a couple of decades ago when the profitability of operating these fields was severely threatened by low world petroleum prices and the high overhead of operating the offshore oil and gas platforms. This effort resulted in significant changes to how these oil fields were operated and allowed the industry to continue profitable operation of these platforms. This example has some remarkable parallels to the U.S. commercial nuclear industry as described in the next section. This report provides an analysis and planning framework for such a nuclear plant operating model transformation based on the transferable learnings from the North Sea transformation. This framework is termed Integrated Operations for Nuclear or ION. This report describes the key principles and methods of Integrated Operations and how they are being applied in a collaboration between the DOE Light Water Reactor Sustainability Program and Xcel Energy in an initiative to transform its operating model for performance improvement and long-term sustainability. It describes a method to bring the operating costs of a nuclear fleet in line with market-based pricing, transforming work functions to reduce cost with technology innovations. This initiative will continue over the next several years in the detailed development of transformative concepts for nuclear plants, which will be published as follow-up to this initial report on Integrated Operations for Nuclear.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design study of a high power rotary transformer

A design study was made on a rotary transformer for transferring electrical power across a rotating spacecraft interface. The analysis was performed for a 100 KW, 20 KHz unit having a ""pancake'' geometry. The rotary transformer had a radial (vertical) gap and consisted of 4-25 KW modules. It was assumed that the power conditioning comprised of a Schwarz resonant circuit with a 20 KHz switching frequency. The rotary transformer, mechanical and structural design, heat rejection system and drive mechanism which provide a complete power transfer device were examined. The rotary transformer losses, efficiency, weight and size were compared with an axial (axial symmetric) gap transformer having the same performance requirements and input characteristics which was designed as part of a previous program. The ""pancake'' geometry results in a heavier rotary transformer primarily because of inefficient use of the core material. It is shown that the radial gap rotary transformer is a feasible approach for the transfer of electrical power across a rotating interface and can be implemented using presently available technology.

Weinberger, S. M.↗

Transform fault earthquakes in the North Atlantic: Source mechanisms and depth of faulting

The centroid depths and source mechanisms of 12 large earthquakes on transform faults of the northern Mid-Atlantic Ridge were determined from an inversion of long-period body waveforms. The earthquakes occurred on the Gibbs, Oceanographer, Hayes, Kane, 15 deg 20 min, and Vema transforms. The depth extent of faulting during each earthquake was estimated from the centroid depth and the fault width. The source mechanisms for all events in this study display the strike slip motion expected for transform fault earthquakes; slip vector azimuths agree to 2 to 3 deg of the local strike of the zone of active faulting. The only anomalies in mechanism were for two earthquakes near the western end of the Vema transform which occurred on significantly nonvertical fault planes. Secondary faulting, occurring either precursory to or near the end of the main episode of strike-slip rupture, was observed for 5 of the 12 earthquakes. For three events the secondary faulting was characterized by reverse motion on fault planes striking oblique to the trend of the transform. In all three cases, the site of secondary reverse faulting is near a compression jog in the current trace of the active transform fault zone. No evidence was found to support the conclusions of Engeln, Wiens, and Stein that oceanic transform faults in general are either hotter than expected from current thermal models or weaker than normal oceanic lithosphere.

Bergman, Eric A.↗

Transform fault earthquakes in the North Atlantic - Source mechanisms and depth of faulting

The centroid depths and source mechanisms of 12 large earthquakes on transform faults of the northern Mid-Atlantic Ridge were determined from an inversion of long-period body waveforms. The earthquakes occurred on the Gibbs, Oceanographer, Hayes, Kane, 15 deg 20 min, and Vema transforms. The depth extent of faulting during each earthquake was estimated from the centroid depth and the fault width. The source mechanisms for all events in this study display the strike slip motion expected for transform fault earthquakes; slip vector azimuths agree to 2 to 3 deg of the local strike of the zone of active faulting. The only anomalies in mechanism were for two earthquakes near the western end of the Vema transform which occurred on significantly nonvertical fault planes. Secondary faulting, occurring either precursory to or near the end of the main episode of strike-slip rupture, was observed for 5 of the 12 earthquakes. For three events the secondary faulting was characterized by reverse motion on fault planes striking oblique to the trend of the transform. In all three cases, the site of secondary reverse faulting is near a compression jog in the current trace of the active transform fault zone. No evidence was found to support the conclusions of Engeln, Wiens, and Stein that oceanic transform faults in general are either hotter than expected from current thermal models or weaker than normal oceanic lithosphere.

Bergman, Eric A.↗

Transform coding for space applications

Data compression coding requirements for aerospace applications differ somewhat from the compression requirements for entertainment systems. On the one hand, entertainment applications are bit rate driven with the goal of getting the best quality possible with a given bandwidth. Science applications are quality driven with the goal of getting the lowest bit rate for a given level of reconstruction quality. In the past, the required quality level has been nothing less than perfect allowing only the use of lossless compression methods (if that). With the advent of better, faster, cheaper missions, an opportunity has arisen for lossy data compression methods to find a use in science applications as requirements for perfect quality reconstruction runs into cost constraints. This paper presents a review of the data compression problem from the space application perspective. Transform coding techniques are described and some simple, integer transforms are presented. The application of these transforms to space-based data compression problems is discussed. Integer transforms have an advantage over conventional transforms in computational complexity. Space applications are different from broadcast or entertainment in that it is desirable to have a simple encoder (in space) and tolerate a more complicated decoder (on the ground) rather than vice versa. Energy compaction with new transforms are compared with the Walsh-Hadamard (WHT), Discrete Cosine (DCT), and Integer Cosine (ICT) transforms.

Glover, Daniel↗

Evaluation of a Multi-kw, High Frequency Transformer for Space Applications

Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.

Roth, Mary Ellen↗

High Accuracy Evaluation of the Finite Fourier Transform Using Sampled Data

Many system identification and signal processing procedures can be done advantageously in the frequency domain. A required preliminary step for this approach is the transformation of sampled time domain data into the frequency domain. The analytical tool used for this transformation is the finite Fourier transform. Inaccuracy in the transformation can degrade system identification and signal processing results. This work presents a method for evaluating the finite Fourier transform using cubic interpolation of sampled time domain data for high accuracy, and the chirp Zeta-transform for arbitrary frequency resolution. The accuracy of the technique is demonstrated in example cases where the transformation can be evaluated analytically. Arbitrary frequency resolution is shown to be important for capturing details of the data in the frequency domain. The technique is demonstrated using flight test data from a longitudinal maneuver of the F-18 High Alpha Research Vehicle.

Morelli, Eugene A.↗

Comparison of Boundary Layer Similarity Transformations for High Mach Number Flows

Reynolds averaged Navier-Stokes (RANS) simulations of the turbulent boundary layer flow on a flat plate are performed across a Mach number range of 0.3 up to 16 using the computational fluid dynamics (CFD) software, VULCAN-CFD. The simulation results are used to evaluate the ability of the Van Driest transformation and the transformation of Trettel and Larsson to collapse boundary layer velocity profiles under various flow conditions across the range of Mach numbers. The flat platewall boundary conditions and leading edge geometry are varied from adiabatic to isothermal and sharp to blunted to reveal the physics of how these effects impact the performance of the chosen flow transformations. Results indicate that the transformation of Trettel and Larsson produces a better collapse of velocity profile data than the Van Driest transformation regardless of Mach number, wall boundary condition, or leading edge geometry. In addition, the velocity gradients obtained from the transformation of Trettel and Larsson match the normalized untransformed velocity gradients much more closely than those obtained using the Van Driest transformation.

DiGregorio, Nicholas J.↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗