Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optical Thomson scatter from a laser-ablated magnesium plume

We have carried out an optical Thomson scatter study of a KrF laser-ablated Mg plume. The evolution of the electron temperature and density at distances 2-5 mm from the target surface has been studied. We have observed that the electron density falls more rapidly than the atomic density and believe that this is a result of rapid dielectronic recombination. A comparison of the electron density profile and evolution with simple hydrodynamic modeling indicates that there is a strong absorption of the laser in the plasma vapor above the target, probably due to photoionization. We also conclude that an isothermal model of expansion better fits the data than an isentropic expansion model. Finally, we compared data obtained from Thomson scatter with those obtained by emission spectroscopy under similar conditions. The two sets of data have differences but are broadly consistent.

36 MATERIALS SCIENCE↗

A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exact relativistic expressions for polarization of incoherent Thomson scattering

We present a derivation of the degree of polarization for incoherent Thomson scattering (TS) using Mueller matrix formalism. An exact analytic solution is obtained for spectrum-integrated matrix elements. The solution is valid for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. It is based on a newly developed theoretical model, a finite transit time (FTT) correction to previous theoretical work on TS polarization. The Mueller matrix elements are substantially different from previous calculations without the FTT correction, even to the lowest linear order in T e =m e c 2 <<1. Mathematically, the derivation is a unique example of fully analytical integration of the 3D scattering operator over a relativistic Maxwellian distribution function; experimentally, the results have application to the use of the polarization properties of Thomson scattered light as a method of electron temperature measurement. The results can also be used as a reliable tool for benchmarking and verification of numerical codes for frequency resolved properties of TS polarization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment (invited)

Here, a novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fast shutter. This –10 3 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot T e (R) for n e > 5 × 10 18 m –3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson scattering measurements on DIII-D using in-vessel laser mirrors and lenses to diagnose a new divertor location

Translatable in-vessel mirrors have allowed the DIII-D Thomson scattering system to diagnose the divertor plasma in high triangularity shaped plasmas. Previous divertor Thomson scattering measurements in DIII-D were restricted to spatial locations along a Nd:YAG laser beam that was directed through a vertical port. This only allowed measurements to be made in low triangularity shaped plasmas. The new mirrors re-route the laser underneath floor tiles to a position of smaller major radius as necessary for high triangularity plasmas. New in-vessel collection optics transmit scattered light from regions inaccessible to external lenses. Damage to mirrors and high stray light levels are challenges that were overcome to successfully make these measurements. Through the careful use of baffles and light shields, stray light leakage into polychromator detector channels was reduced to negligible levels, allowing temperature measurements below 1 eV. The system is described and the initial results introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of non-Maxwellian electron velocity distribution functions on inferred plasma parameters in collective Thomson scattering

Optical collective Thomson scattering provides precise density and temperature measurements in numerous plasma-physics experiments. The accuracy of such measurements depends on the core assumption that the underlying electron distribution functions in under-dense laser-produced plasmas are Maxwellian. A statistically based, quantitative analysis of the errors in the measured electron density and temperature is presented when synthetic data calculated using a non-Maxwellian electron distribution function is fit assuming a Maxwellian electron distribution. Such analysis can lead to errors of up to 50% in temperature and 30% in density, in the specific case of super-Gaussian distributions characteristic of inverse bremsstrahlung heating. Furthermore including the proper family of non-Maxwellian electron distribution functions, as a fitting parameter, in Thomson-scattering analysis removes the model-dependent errors in the inferred parameters at a minimal cost to the statistical uncertainty.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A scalable real-time framework for Thomson scattering analysis: Application to NSTX-U

A detailed description of a prototype setup for real-time (RT) Thomson scattering (TS) analysis is presented and implemented in the multi-point Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade (NSTX-U). The data acquisition hardware was upgraded with RT capable electronics (RT-analog digital converters and a RT server) that allow for fast digitization of the laser pulse signal of eight radial MPTS channels. In addition, a new TS spectrum analysis software for a rapid calculation of electron temperature ( T e ) and electron density ( n e ) was developed. Testing of the RT hardware and data analysis software was successfully completed and benchmarked against the standard, post-shot evaluation. Timing tests were performed showing that the end-to-end processing time was reproducibly below 17 ms for the duration of at least 5 s, meeting a 60 Hz deadline by the laser pulse repetition rate over the length of a NSTX-U discharge. The presented RT framework is designed to be scalable in system size, i.e., incorporation of additional radial channels by solely adding additional RT capable hardware. In conclusion, it is scalable in its operation duration and was continuously running for up to 30 min, making it an attractive solution for machines with long discharges such as advanced, non-inductive tokamaks or stellarators.

47 OTHER INSTRUMENTATION↗

Characterization of thermal transport and evolution of Au plasma in ICF experiments by Thomson scattering

Here, this paper demonstrates the capability of optical Thomson scattering (OTS) to measure thermal transport, and provides support to radiation hydrodynamic and kinetic simulations of electron thermal transport and plasma evolution. OTS theory and plasma simulations are applied to the interpretation of experimental measurements of laser-produced plasma from spherical gold targets on the OMEGA laser facility. The dynamical form factor, S($\vec{k}$, ω), of electron density fluctuations that is used in the fitting of Thomson scattering spectra includes ion–ion collisions and effects of non-Maxwellian distribution functions. OTS measurements and their interpretation are consistent with the nonlocal transport model in radiation hydrodynamic simulations as well as with kinetic simulations in the second half of the probe pulse duration. In particular, the reversal of heat transport during cooling is observed to be consistent with simulations, while some discrepancies are noted during the initial heating of the Au targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of coherent Thomson scattering from a low temperature plasma

In this work, the spectrum of coherent Thomson scattering (CTS) induced by a periodic ponderomotive perturbation in a low-density low temperature plasma is considered. The analysis is performed for the case when the period of the resulting optical lattice is less than the Debye screening length in the plasma by solving an electron Boltzmann equation, where the total force is the sum of the periodic force due to the optical lattice and the electrostatic force due to self-consistent electric field in the plasma. An analogy between the CTS spectra calculated here and coherent Rayleigh scattering spectra in a neutral gas is established. For relatively low intensity for the optical lattice, the calculated CTS spectra are nearly Gaussian with widths slightly wider than the incoherent Thomson widths. We demonstrate that at higher intensities the line shape narrows and saturates to a width approximately half of that found at low lattice intensities. The proportionality of the spectral width to the square root of the electron temperature allows one to extract the electron temperature from the saturated spectra. Possible application of CTS for remote measuring the electron temperature in plasma is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collective Thomson scattering measurement of plasma evolution during the current pulse in a laser-triggered switch

High-voltage laser-triggered switches (HV-LTSs) are used in pulsed-power applications where low jitter and precise timing are required. The switches allow operation in the megaampere, megavolt regime while maintaining low insertion losses. Currently, there is a lack of detailed plasma measurements in these switches, yet such measurements are needed to elucidate the detailed physics, which include a range of processes such as laser breakdown, streamer formation and growth, current flow, plasma evolution, and cooling. Detailed spatially- and temporally resolved measurements of plasma properties within the switches could contribute to validating and advancing numeric models of these systems. This contribution presents laser Thomson scattering measurements of the electron number density and temperature evolution in a HV-LTS. The switch was operated at 6 kV with current flow for a duration of 145 ns and a peak current density of 0.2 MA/cm2 into a matched load. The Thomson scattering diagnostic system uses a 532 nm probe from an Nd:YAG laser allowing a temporal resolution of ∼10 ns. We find that during the switch current pulse, the plasma electron temperature rose from a starting value of 8.1 ± 1.6 eV (due to cooling of the earlier trigger laser plasma) to a peak value of 26 ± 5 eV with an associated increase in the electron density from 8.6 ± 1.7 × 1017 to 3.1 ± 0.6 × 1018 cm−3.

Gottfried, Jacob A. (ORCID:0000000290058841)↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Real-Time Software for Thomson Scattering Analysis at NSTX-U

The Thomson Scattering Diagnostic on the National Spherical Tokamak eXperiment Upgrade (NSTX-U) has been an essential system for many operational campaigns due to its function of measuring plasma electron density and temperature. Constructive feedback to improve the next plasma discharge, however, has been limited because of in-between shots analysis. Plasma Control, therefore, desires a diagnostic system that is real-time capable. This contribution presents the development of software that demonstrates the feasibility of a real-time Thomson Scattering diagnostic system for NSTX-U. The developed software is able to evaluate the electron temperature and density within 2.5ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Thomson scattering measurement of temperature in warm dense carbon

Here, a novel platform to measure the equation of state using a combination of diagnostics, where the spectrally resolved x-ray Thomson scattering (XRTS) is used to obtain accurate temperature measurements of warm dense matter (WDM) was developed for the OMEGA laser facility. OMEGA laser beams have been used to drive strong shocks in carbon targets creating WDM and generating the Ni He-alpha x-ray probe used for XRTS. Additional diagnostics including x-ray radiography, velocity interferometry and streaked optical pyrometry provided complementary measurements of density and pressure. The WDM regime of near solid density and moderate temperatures (1–100 eV) is a challenging yet important area of research in inertial confinement fusion and astrophysics. This platform has been used to study off-Hugoniot states of shock-released diamond and graphite at pressures between 1 and 10 Mbar and temperatures between 5 and 15 eV as well as first x-ray Thomson scattering data from shocked low density CH foams reaching five times compression and temperatures of 20–30 eV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-colour interferometry and Thomson scattering measurements of a plasma gun

We present experimental measurements of a pulsed plasma gun, using two-colour imaging laser interferometry and spatially resolved Thomson scattering. Interferometry measurements give an electron density n e &approx; 2:7 &times; 1017 cm -3 at the centre of the plasma plume, at 5 mm from the plasma gun nozzle. The Thomson scattered light is collected from two probing angles allowed us to simultaneously measure the collective and non-collective spectrum of the electron feature from the same spatial locations. The inferred electron densities from the location of the electron plasma waves is in agreement with interferometry. The electron temperatures inferred from the two spectra are not consistent, with T e &approx; 10 eV for non-collective scattering and T e &approx; 30 eV for collective scattering. Here, we discuss various broadening mechanisms such as finite aperture effects, density gradients within the collective volume and collisional broadening to account for some of this discrepancy. We also note the significant red/blue asymmetry of the electron plasma waves in the collective scattering spectra, which could relate to kinetic effects distorting the distribution function of the electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning and operation of a real-time multi-point Thomson scattering evaluation system at Wendelstein 7-X

A real-time multi-point Thomson scattering (rtMPTS) evaluation system has recently been installed and commissioned at the Wendelstein 7-X (W7-X) stellarator during the 2024 -2025 operational phases. This system has demonstrated successful evaluation of Thomson scattered spectra on millisecond timescales. We discuss initial results from this system, consisting of a comparison of different evaluation techniques, assessment of system evaluation times, and proof-of-principle control experiments carried out with the W7-X poloidal correlation reflectometer (PCR) system. This diagnostic represents the first step towards the development of a density profile controller at W7-X, which can be leveraged to support steady-state operation.

Mohammed, Ameer [Princeton Plasma Physics Laborato↗

A pulse-burst laser system for Thomson scattering on NSTX-U

A pulse-burst laser system has been built for Thomson scattering on NSTX-U, and is currently being integrated into the NSTX-U Thomson scattering diagnostic system. The laser will be operated in three distinct modes. The base mode is continuous 30 Hz rep rate, and is the standard operating mode of the laser. The base mode will be interrupted to produce a "slow burst" (specified 1 kHz rep rate for 50 ms) or a "fast burst" (specified 10 kHz rep rate for 5 ms). The combination of base mode→ interruption→ burst mode is new and has not been implemented on any previous pulse-burst laser system. Laser pulsing is halted for a set period (~ 1 minute) following a burst to allow the YAG rods to cool; this type of operation is called a heat-capacity laser. The laser is Nd:YAG operated at 1064 nm, q-switched to produce ≥ 1.5 J pulses with ~ 20 ns FWHM. It is flashlamp pumped, with dual-rod oscillator (9 mm) and dual-rod amplifier (12 mm). Variable pulsewidth drive of the flashlamps is accomplished by IGBT (insulated gate bipolar transistor) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction. The laser system has demonstrated compliance with all specifications, and is capable of exceeding design specifications by significant margins, e.g., higher rep rates for longer burst periods. Burst operation of this laser system will be used to capture fast time evolution of the electron temperature and density profiles during events such as ELMs, the L-H transition, and various MHD modes.

47 OTHER INSTRUMENTATION↗

Next steps in high-repetition-rate laser development for Thomson scattering

Design of a next generation high-rep-rate laser system is underway, aiming for a maximum rep rate of 100 kHz for 1 ms. This will be a "pulse-burst" laser, which is a type of heat-capacity laser. Heat-capacity laser operation is characterized by a burst of pulses of limited duration, with burst length ≤100 ms and pulse rep rate ≥1 kHz. Waste heat accumulates in the laser rod during the burst. This heat is deposited evenly throughout the rod volume, with very little heat removed during the burst, such that temperature rises evenly across the rod radius. Thus beam distortion due to thermal gradients is small. Heat is removed from the rod after the burst, with typically tens of seconds between bursts. Pulse-burst operation of flashlamp pumped Nd:YAG lasers is a cost-effective route to high-rep-rate capability. Pulse-burst laser systems with "fast burst" rep rates in the range of 10–20 kHz have been built for the Thomson scattering diagnostics on MST, NSTX-U, and LHD. For Thomson scattering diagnostic application, the typical requirements are 1064 nm, 1–2 J/pulse, ≤30 ns FWHM pulse, with a top-hat beam profile. A major requirement for this next generation laser system is flexibility in burst sequence programs, ranging from 1 kHz for 100 ms to 100 kHz for 1 ms, and a variety of scenarios in between so that operation can be tailored to plasma experiment requirements. Flashlamp pumping will be used for this next generation laser because it is inexpensive and flexible. A new switch-regulated flashlamp driver will provide improved flashlamp control at lower cost. Additional design issues such as the optimum flashlamp pumping spectrum and optimum Nd doping will be addressed. The use of commercial off-the-shelf components will be maximized in this laser system so that pulse-burst systems can be developed and built by others for new applications.

47 OTHER INSTRUMENTATION↗

Thomson Scattering with Gain

Thomson-scattering signals can be significantly modified by convective gains associated with the stimulated Raman scattering and stimulated Brillouin scattering instabilities as the scattered light traverses the probe beam. Gain results in amplification and narrowing of the red-shifted (i.e., Stokes) scattered light, whereas blue-shifted (anti-Stokes) features are depleted and broadened, making the relative prominence of these features a key signature of gain. Not accounting for instability growth has been a ubiquitous source of error in previous Thomson-scattering measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗