Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Modeling and Optimization of a Nuclear Integrated Energy System for the Remote Microgrid on El Hierro

Nuclear microreactors are a potential technology to provide heat and electricity for remote microgrids. There is potential for the microgrid on the island of El Hierro to use a microreactor, within an integrated energy system (IES), to generate electricity and provide desalinated water. This work proposes a workflow for optimizing and analyzing IESs for microgrids. In this study, an IES incorporating a microreactor, thermal energy storage (TES) system, combined heat and power plant, and a thermal desalination plant was designed, optimized, and analyzed using Idaho National Laboratory’s Framework for Optimization of Resources and Economics (FORCE) toolset. The optimization tool, Holistic Energy Resource Optimization Network (HERON), was used to determine the optimal capacity sizes and dispatch for the reactor and thermal energy storage systems to meet demand. The optimized reactor and TES sizes were found to be 11.61 MWth and 58.47 MWhth, respectively, when optimizing the IES to replace 95% of the island’s existing diesel generation needs. A dynamic model of the system was created in the Modelica language, using models from the HYBRID repository, to analyze and verify the dispatch from the optimizer. The dynamic model was able to meet the ramp rates while maintaining reactor power with minimal control adjustments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Compressed gas energy storage

Methods and systems for thermal energy storage and enhanced oil recovery are described herein. In some embodiments, natural gas may be injected down a well which has been previously hydraulically fractured to store thermal energy and to stimulate the well to greater hydrocarbon production.

Augustine, Chad↗

Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

25 ENERGY STORAGE↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

High temperature thermochemical energy storage materials

Disclosed are thermal energy storage systems and methods that utilize metal carbonate eutectics that can undergo high temperature reversible reactions to form mixtures of metal oxides. The metal oxides undergo an exothermic reaction with carbon dioxide to form the molten metal carbonate eutectics, and the molten metal carbonate eutectics undergo an endothermic decarbonization reaction to form the metal oxides and carbon dioxide. By carrying out the reversible reactions at a temperature above the melting point of the carbonate eutectic, the systems provide high thermal conductivity and reversible stability for thermal energy storage.

25 ENERGY STORAGE↗

Transient Physical Modelling for the Coupling of a High Temperature Gas Reactor with Thermal Energy Storage

Improving the flexibility of nuclear reactors to meet fluctuating demand on grids with high renewable energy generation penetration is key to improving reactor economics. Economic optimization using the code HERON gives maximum profit of coupling high temperature gas reactors (HTGRs) to thermal energy storage (TES) systems in the configuration shown in Figure 1 when following the demand in Figure 3. We look to model the physics of operation for a HTGR-TES using the HYBRID library in the code Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing district energy systems by integrating Borehole Thermal Energy Storage Using a Mixed-Integer Linear Programming g-function framework with a Multi-Timescale Rolling Horizon method

Shallow geothermal has gained increasing attention in recent years; however, a reliable framework for its accurate incorporation into large-scale energy system optimization remains lacking. This study proposes a Mixed-Integer Linear Programming (MILP) framework combined with the g-function approach to integrate Borehole Thermal Energy Storage (BTES) technology into energy system optimization. Validation against a Modelica-based reservoir network simulation demonstrates that the proposed framework effectively captures the ground thermal response under varying energy loads and accurately estimates the borefield energy supply. To enhance scalability, a Rolling Horizon with Multi-Timescale (RH-MTS) method is further introduced, reducing computational time by 73 % for the 1-year optimization model with only minor loss of optimality. The framework is demonstrated through the case study of the UC Berkeley campus. Results indicate that BTES is a cost-effective and low-carbon solution: two borefields comprising 382 boreholes can meet 8.0 % and 6.6 % of the total campus heating and cooling demand, respectively, at an average energy rate of 0.70–0.77 USD/kWh and carbon intensity of 0.54 kg-CO2/kWh. Short-term analysis reveals a 35%–65% decline in BTES energy flow after 3–6 months of continuous heating/cooling operation, while long-term simulation shows that annual energy production of BTES can vary by up to 12.0 % after four years before stabilizing. Overall, this study develops a novel optimization framework that couples physics-based g-function method with MILP optimization framework, thereby advancing methodological development for shallow-geothermal integration and providing actionable guidance for BTES deployment in district-energy systems.

Yang, Jiahui↗

The role of moisture in MgCl 2 salt: A multiscale approach to TES performance

This study presents a comprehensive multiscale analysis to evaluate the influence of moisture on the thermal performance of thermal energy storage systems using magnesium chloride (MgCl 2 ) as the phase-changing material. The system uses graphite foam with 90% relative density to enhance thermal conductivity. The analysis includes thermal conductivity calculations and specific heat capacity for different hydrate phases of MgCl 2 : Anhydrous, Mono, Di, Tetra, and Hexa. These properties were evaluated for the first time using the phonon density of states from Density Functional Theory simulations. Results showed that thermal conductivity decreased, while specific heat capacity increased by a factor of two as the phase changed from anhydrous to hexahydrate. Meso-scale models were created to account for the anisotropy of graphite foam and property variations of the MgCl 2 hydrate phases. Asymptotic Expansion homogenization simulations determined the anisotropic thermal conductivity for all phases. This unique methodology improved simulation accuracy, which matched experimental data for anhydrous MgCl 2 . A parametric study examined various operating conditions and their effect on TES performance. It revealed that higher charging temperatures did not enhance exergy efficiency, but increased discharge mass flow rates improved it due to better heat transfer. Thermal performance evaluated by the exergy efficiency remained consistent across hydrate systems under the tested conditions. Furthermore, the study suggests that this uniformity is linked to missing key data, particularly latent heat and melting point for different hydrates. Overall, it highlights the importance of multiscale effects and accurate material properties in designing and optimizing TES systems.

Molten salt degradation↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗