Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Data Report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Radiolysis Data for Hydrogen Gas Generation During Gamma Irradiation of Pre-Corroded and Pristine Aluminum Samples - An Aluminum SNF Dry Storage Study Interim Report

Information and data from radiolysis testing to measure hydrogen (H₂) generated from hydrated oxides on aluminum exposed to ⁶⁰Co radiation were reviewed to evaluate hydrogen generation with radiation dose. Hydrogen generation rate is a primary input to the coupled thermal-chemical system model of the performance of aluminum-clad spent nuclear fuel in a dry storage canister (ASNF-in-canister) over its storage life. Hydrogen generation data and hydrogen generation rate (hydrogen generated per absorbed radiation dose, $\Delta$(H₂)/$\Delta$(dose)) were reported in two reports for radiolysis testing [1, 2]. The testing involved first-time data¹ for radiolytic yield of hydrogen from hydrated-oxides-on-aluminum substrates, and from pristine (non-corroded) aluminum substrates. The laboratory-grown hydrated-oxides-on-aluminum substrates contained a ~ 5 μm film consisting of the trihydroxide bayerite (Al(OH)₃) with amounts of the oxyhydroxide boehmite (AlOOH). These specimens were assumed to also contain physisorbed water (unquantified). The pristine substrates were flat coupons of aluminum that were ground to a 600-grit finish but were not immersed in water to grow a hydrated oxide. The pristine substrates were tested as companion specimens to provide information on hydrogen generation from material without chemisorbed water and were assumed to contain physisorbed water (unquantified).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space Shuttle Orbiter Crew Hatch Jettison Test using a 0.0405-scale model (16-0) in the Texas A/M low speed wind tunnel (OA362). Space Shuttle aerothermodynamic data report

This report contains post-test information for the Space Shuttle Orbiter Crew Hatch Jettison Test OA362 which was conducted in the Texas A&M Low Speed Wind Tunnel from 6/15/87 to 6/22/87. The test objective was to verify that the crew hatch, once jettisoned, would clear the orbiter under various simulated flight conditions. Several model hatches were used with the 0.0405-scale orbiter (Model 16-0). The model's angle of attack was set at 10, 15, and 20 degrees while the sideslip had values of minus 5, 0, and plus 5 degrees. The full scale Qbars that were simulated were 105, 128, 160, and 210 psf. In the hatch jettison mechanism itself, the plunger pressure was varied to achieve horizontal velocities of 3, 5, 7, and 20.1 feet per second model scale, and the plunger location was varied to achieve a variety of rotational velocities. The orbiter model was subjected to 122 runs with 13 different hatches. Of these, 60 were good runs.

Mitchell, C. E.↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

Source record↗

Thematic mapper flight model preshipment review data package. Volume 4: Appendix. Part B: Scan mirror assembly data

Data from the thematic mapper scan mirror assembly (SMA) acceptance test are presented. Documentation includes: (1) a list of the acceptance test discrepancies; (2) flight 1 SMA test data book; (3) flight 1 SMA environmental report; (4) the configuration verification index; (5) the flight 1 SMA test failure reports; (6) the flight 1 data tapes log; and (7) the requests for deviation/waivers.

Source record↗

Supersonic Aftbody Closure Wind-Tunnel Testing, Data Analysis, and Computational Results

This paper reports on the model, test, and results from the Langley Supersonic Aftbody Closure wind tunnel test. This project is an experimental evaluation of the 1.5% Technology Concept Aircraft (TCA) aftbody closure model (Model 23) in the Langley Unitary Plan Wind Tunnel. The baseline TCA design is the result of a multidisciplinary, multipoint optimization process and was developed using linear design and analysis methods, supplemented with Euler and Navier-Stokes numerical methods. After a thorough design review, it was decided to use an upswept blade attached to the forebody as the mounting system. Structural concerns dictated that a wingtip support system would not be feasible. Only the aftbody part of the model is metric. The metric break was chosen to be at the fuselage station where prior aft-sting supported models had been truncated. Model 23 is thus a modified version of Model 20. The wing strongback, flap parts, and nacelles from Model 20 were used, whereas new aftbodies, a common forebody, and some new tails were fabricated. In summary, significant differences in longitudinal and direction stability and control characteristics between the ABF and ABB aftbody geometries were measured. Correcting the experimental data obtained for the TCA configuration with the flared aftbody to the representative of the baseline TCA closed aftbody will result in a significant reduction in longitudinal stability, a moderate reduction in stabilizer effectiveness and directional stability, and a moderate to significant reduction in rudder effectiveness. These reductions in the stability and control effectiveness levels of the baseline TCA closed aftbody are attributed to the reduction in carry-over area.

Allen, Jerry↗

SCATHA SSPM charging response: NASCAP predictions compared with data

Models for the satellite surface potential monitor (SSPM) units constructed in the NASCAP code and the results of comparing predictions to surface voltage and baseplate current data are reported. Several peculiarities in the test data are noted. Preliminary results from space simulations of a SCATHA model with environments representative of the day 87, 1979, eclipse injection event are presented, and their implications for predicting space response are discussed.

Purvis, C. K.↗

Bearing tester data compilation, analysis, and reporting and bearing math modeling

A test condition data base was developed for the Bearing and Seal Materials Tester (BSMT) program which permits rapid retrieval of test data for trend analysis and evaluation. A model was developed for the Space shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump shaft/bearing system. The model was used to perform parametric analyses to determine the sensitivity of bearing operating characteristics and temperatures to variations in: axial preload, contact friction, coolant flow and subcooling, heat transfer coefficients, outer race misalignments, and outer race to isolator clearances. The bearing program ADORE (Advanced Dynamics of Rolling Elements) was installed on the UNIVAC 1100/80 computer system and is operational. ADORE is an advanced FORTRAN computer program for the real time simulation of the dynamic performance of rolling bearings. A model of the 57 mm turbine-end bearing is currently being checked out. Analyses were conducted to estimate flow work energy for several flow diverter configurations and coolant flow rates for the LOX BSMT.

Source record↗

Test and Evaluation of the Surveyor 3 Television Camera Returned from the Moon by Apollo 12

Results are presented of engineering tests of the Surveyor III television camera, which resided on the moon for 2 and 1/2 years before being brought back to earth by the Apollo XII astronauts. Electric circuits, electrical, mechanical, and optical components and subsystems, the vidicon tube, and a variety of internal materials and surface coatings were examined to determine the effects of lunar exposure. Anomalies and failures uncovered were analyzed. For the most part, the camera parts withstood the extreme environment exceedingly well except where degradation of obsolete parts or suspect components had been anticipated. No significant evidence of cold welding was observed, and the anomalies were largely attributable to causes other than lunar exposure. Very little evidence of micrometeoroid impact was noted. Discoloration of material surfaces -- one of the major effects noted--was found to be due to lunar dust contamination and radiation damage. The extensive test data contained in this report are supplemented by results of tests of other Surveyor parts retrieved by the Apollo XII astronauts, which are contained in a companion report.

Source record↗