Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

miniDOT Logger Dissolved Oxygen and Temperature Data of Wetland Surface Water, Old Woman Creek NERR, Huron, OH, 2022-06-15 to 2023-12-15

This dataset contains timeseries data of dissolved oxygen (DO) and temperature measurements of the surface water in a wetland at Old Woman Creek Estuarine Research Reserve in Huron, OH. Dissolved oxygen and temperature measurements were made in the overlying water column of wetland to assess how oxygen changed over time with hydrological events. Measurements were collected by a miniDOT Logger. Data was collected over 1.5 years (June 2022 to December 2023). The miniDOT_DO_Temp_DataFile.csv contains the DO and temperature measurements that were collected every 10 minutes. The water levels of the site varied over-time as the wetland flooded and dried. So, sometimes the miniDOT logger would be out of the water column, resulting in high oxygen levels. Depth of the water column was recorded at every in-person site visit. The miniDOT_Depth_DataFile.csv contains the hand-measured surface water depth measurements for comparison to the logger-collected data. Information on the deployment and measurement methods can be found in the miniDOT_InstallationMethods.csv file.

54 ENVIRONMENTAL SCIENCES↗

Fiber Optic Temperature Sensor Using Dual Air- Filled Fabry-Pérot Cavities With Variable Pressure

We present an approach for high temperature measurement using a pair of fiber-optic Fabry–Pérot (FP) cavities filled with gas of identical but variable pressure. One of the FPs (reference FP) is placed in the cold zone with a known temperature. The temperature of the measuring FP can be deduced by the spectral fringe shift vs. pressure of the two FPs. This method does not require measurement of the pressure or the knowledge of the optical properties of the gas. The use of gas as the sensing material and the measurement mechanism also implies long-term stability and eliminates the cross-sensitivity to strain. We fabricated the sensors and tested them for measuring temperature up to 800 °C. Here, the sensor shows good linearity in the range. Long-term test conducted at 800 °C exhibited the stability of the sensor with fluctuations of ≤0.3% over a duration exceeding 100 hours.

42 ENGINEERING↗

Accurate temperature determination from XRD and EXAFS measurements (Full Technical Final Report)

Measuring temperature is of fundamental importance for High Energy Density science (HED), for studying melting, phase transitions and equations of state. However, temperature determination of high pressure and high temperature (0.1-1 eV) condensed matter remains one of the biggest challenges in such experiments. This project used a combination of advanced experimental techniques and state-of-the-art computational methods to construct a framework relating the observed attenuation of X-ray diffraction (XRD) and Extended X-ray Absorption Fine Structure (EXAFS) signals due to thermal fluctuations to the actual temperature achieved in the experiments. This approach was benchmarked against low temperature resistive heating diamond anvil cell (DAC) experiments and cross-validated at higher pressure and temperature by combining the two complementary and independent techniques, diffraction and EXAFS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal interfaces in dynamic compression experiments

Temperature is a difficult thermodynamic variable to measure in dynamic compression experiments. Optical pyrometry is a general-purpose technique for measuring temperature from a radiant surface, but that surface is often the interface between distinct materials with temperatures that vary spatially along the loading direction. This leads to a fundamental problem: how does the measured interface temperature relate to this temperature profile along the compression axis? Numerical analysis of loading history and thermal diffusion at these interfaces shows that seemingly subtle changes in experiment geometry can lead to very different temperature profiles. We compare these results to laboratory temperature measurements of shock-compressed tin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of High-Temperature Emissivity Measurement Capabilities for Molten Salts at PNNL

In this study, an emissivity measurement system for a liquid molten salt was developed on the bases on the Stefan Boltzmann Law. A prototype device operating in ambient atmosphere was constructed an initial result compared well with available literature. The diffuse emissivity of NaCl-KCl system (NaCl, 51mol% NaCl – 49mol% KCl and KCl) was measured from 550 to 850 °C at a wavelength of 1.3 µm. The system appears to be relatively invariant with composition but a clear trend of decreasing emissivity values from ~0.9 at 550 °C to 0.75 at 850 °C was observed. A schematic for an enclosed system for inert atmosphere and actinide salts was drafted. Several of the components for fabrication of this device, improved laser system, furnace, nickel for capsule construction, have been purchased and are ready for assembly. The new laser system will have an improved measurement range of 275-1000 °C. The clam shell furnace has a maximum temperature of 1200 °C and will support the hermetically sealed inert encapsulation vessels. Nickel plate and tubing will create a relatively corrosion resistance capsule for testing that can withstand temperature up to 1000 °C. Emissivity measurements are important for a larger effort to understand radiative heat transfer within molten salts at elevated temperatures (600-1000 °C). Literature review of optical salt properties and radiative heat transfer models indicated that systems within elevated temperature regimes could see upwards of 20% or more of their total heat transferred through photonic mechanisms. Ultimately, future work will measure the total thermal conductivity and break down the molecular and radiative portions. Thermal conductivity, along with other thermal properties of molten salts, both coolant and fuel, are fundamental to modeling and simulations that support MSR design. The results presented here and ongoing work at PNNL will be useful in selecting optimal salt compositions, designing reactor systems, and optimizing heat transfer within a MSR power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗

Initial Results From the Newly Upgraded LTX- β

LTX-β, the upgraded Lithium Tokamak Experiment, recently began its first campaign with a goal to study the transport properties of gradient-free electron temperature profile equilibria with increased toroidal field and neutral beam injection. The temperature-gradient-free equilibria in LTX were enabled by the lithium plasma-facing surface. To make the lithium surface conditions more consistent for LTX-β, a new, faster lithium evaporator system has been developed. The toroidal magnetic field has been nearly doubled to ≥0.3 T. Auxiliary heating and fueling with a high flux (35 A, 20 kV) neutral beam has begun. The beam provides core fueling without cold edge neutrals, to test whether flat temperature profiles can be sustained, and makes possible core ion temperature measurements via charge exchange recombination spectroscopy. Neutral beam fueling has been demonstrated with increases in line-integrated density. The coupling of the beam matches well with NUBEAM predictions for shine through. Improved performance has been observed following lithium evaporative coatings and an increase in field strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring: Supporting Data

This dataset was used to assess the performance of a compression algorithm for Soil Deformation and Temperature Monitoring data. The development of this technology is presented in the article named time division duplex (TDD) "TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring" and published in Springer's Journal on Signal Processing Systems. [Time Division Duplex (TDD); Long Range (LoRa)]Field experiment data includes: 1) soil temperature measurements, 2) snow temperature data, 3) soil temperature and deformation data. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 15 minutes. Lists included for probe, datalogger, and packaging components. The two temperature data sets were acquired at a site at the East River Watershed, Colorado, while the temperature/deformation data were collected at the Teller Road (mile 27) site near Nome, Alaska. The package includes 8 comma-separated files (.csv) and one .pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Brine Availability Test in Salt (BATS) FY21 Update

This report summarizes the 2021 fiscal year (FY21) status of ongoing borehole heater tests in salt funded by the disposal research and development (R&D) program of the Office of Spent Fuel & Waste Science and Technology (SFWST) of the US Department of Energy’s Office of Nuclear Energy’s (DOE-NE) Office of Spent Fuel and Waste Disposition (SFWD). This report satisfies SFWST milestone M2SF- 21SN010303052 by summarizing test activities and data collected during FY21. The Brine Availability Test in Salt (BATS) is fielded in a pair of similar arrays of horizontal boreholes in an experimental area at the Waste Isolation Pilot Plant (WIPP). One array is heated, the other unheated. Each array consists of 14 boreholes, including a central borehole with gas circulation to measure water production, a cement seal exposure test, thermocouples to measure temperature, electrodes to infer resistivity, a packer-isolated borehole to add tracers, fiber optics to measure temperature and strain, and piezoelectric transducers to measure acoustic emissions. The key new data collected during FY21 include a series of gas tracer tests (BATS phase 1b), a pair of liquid tracer tests (BATS phase 1c), and data collected under ambient conditions (including a period with limited access due to the ongoing pandemic) since BATS phase 1a in 2020. A comparison of heated and unheated gas tracer test results clearly shows a decrease in permeability of the salt upon heating (i.e., thermal expansion closes fractures, which reduces permeability).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Early- and late-time dynamics of laser-produced plasmas by combining emission and absorption spectroscopy

Optical emission spectroscopy and laser absorption spectroscopy are two highly complementary techniques for diagnosing plasmas, specifically in the determination of important parameters such as temperature and density. In this work, we characterized a laser-produced plasma by combining emission and tunable absorption spectroscopy. Plasmas are produced by focusing pulses from a frequency quadrupled Nd:YAG laser onto a glass target containing a minor concentration of aluminum in an ambient atmosphere of ~100 Torr N 2 . Here, emission spectroscopy is used to investigate the line behavior of Al and Ca, electron density, and excitation temperature at times = 5 μs, while absorption spectroscopy is used to investigate the line behavior of Al and Ca, species density, and kinetic temperature at times = 5-100 μs. A comparison is made between the excitation temperature measured from emission using the Boltzmann plot method and the kinetic temperature measured from absorption; the implications of this comparison on local thermodynamic equilibrium and line-of-sight averaging are discussed. By combining the two methods of optical emission and laser absorption spectroscopy, a comprehensive characterization of the plasma over the entire lifetime of its evolution is possible, leading to a greater understanding of the plasma behavior including particle condensation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ thermal analysis of intermetallic and thermite projectiles in high velocity impact experiments

Particle fragmentation influences thermochemical energy conversion processes in different ways and is of significance in energy generation technologies. Different reactive material formulations trigger varied thermal response in extreme environments such as high velocity impact. Here we investigated optical thermal response of powder gun launched intermetallic (Al:Zr) and thermite (Al:MoO 3 ) projectiles using pyrometry and thermography. Projectiles were launched at 1250 m/s into an air-filled chamber and impacted a steel witness plate to create a dust explosion. The pyrometer was configured to measure temperatures directly at the point of impact, while the thermographic system measured temperatures throughout the explosion chamber. Results show that impact temperatures ranged between 3500 and 4000 K, but that the dynamics of energy conversion were different for the intermetallic and thermite projectiles. The intermetallic exhibited secondary reactions due to fragmented debris impacting the walls of the chamber. The thermite exhibited greater gas generation, propelling the debris field, and producing a more stochastic response with faster spreading and dissipation of thermal energy. Unique features such as microexplosions within fragmented particles were also analyzed. While both reactive materials produce similar temperatures, their mechanisms of energy conversion and release are different, indicating the potential of these materials for different ballistic applications.

42 ENGINEERING↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗