Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cloud Impacts on Photochemistry: Building a Climatology of Photolysis Rates from the Atmospheric Tomography Mission

Measurements from actinic flux spectroradiometers on board the NASA DC-8 during the Atmospheric Tomography (ATom) mission provide an extensive set of statistics on how clouds alter photolysis rates (J values) throughout the remote Pacific and Atlantic Ocean basins. J values control tropospheric ozone and methane abundances, and thus clouds have been included for more than three decades in tropospheric chemistry modeling. ATom made four profiling circumnavigations of the troposphere capturing each of the seasons during 2016–2018. This work examines J values from the Pacific Ocean flights of the first deployment, but publishes the complete Atom-1 data set (29 July to 23 August 2016). We compare the observed J values (every 3 s along flight track) with those calculated by nine global chemistry– climate/transport models (globally gridded, hourly, for a mid-August day). To compare these disparate data sets, we build a commensurate statistical picture of the impact of clouds on J values using the ratio of J -cloudy (standard, sometimes cloudy conditions) to J -clear (artificially cleared of clouds). The range of modeled cloud effects is inconsistently large but they fall into two distinct classes: (1) models with large cloud effects showing mostly enhanced J values aloft and or diminished at the surface and (2) models with small effects having nearly clear-sky J values much of the time. The ATom-1 measurements generally favor large cloud effects but are not precise or robust enough to point out the best cloud-modeling approach. The models here have resolutions of 50–200 km and thus reduce the occurrence of clear sky when averaging over grid cells. In situ measurements also average scattered sunlight over a mixed cloud field, but only out to scales of tens of kilometers. A primary uncertainty remains in the role of clouds in chemistry, in particular, how models average over cloud fields, and how such averages can simulate measurements.

actinic flux spectroradiometers↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Preliminary results from on going simulations and analyses will be presented.

Bruggemann, Jeremy↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. Last summer, NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This is a 30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a 60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution Xray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present a first look at the XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

Zeigler, R. A.↗

Applicability and Utility of the Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center is responsible for curating all of NASA’s astromaterial sample collections (i.e. Apollo samples, Luna Samples, Antarctic Meteorites, Cosmic Dust Particles, Microparticle Impact Collection, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust interstellar particles, and Hayabusa asteroid Itokawa particles) [1-3]. To assist in sample curation and distribution, JSC Curation has recently installed an X-ray computed tomography (XCT) scanner to visualize and characterize samples in 3D. [3] describes the instrumental set-up and the utility of XCT to astromaterials curation. Here we describe some of the current and future projects and illustrate the usefulness of XCT in studying astromaterials.

Eckley, S. A.↗

Investigating Transverse Ply Thickness and Cracking Effects on the Tensile Strain to Failure of Thin-ply, Cross-ply Carbon Composites using X-ray Computed Tomography

The effect of 90°-ply thickness on the fibre direction tensile failure strain of cross-ply laminates was investigated by designing four different cross-ply composite laminate configurations with 90° blocks of varying numbers of plies adjacent to a central block of 0° plies. The range of 90° block thicknesses evaluated included conventional ply thicknesses to allow for comparisons with conventional ply geometries. The central 0° ply block was subjected to primarily longitudinal tension with a small component of transverse tension due to the layup and thermal residual stresses. Advanced instrumentation, including acoustic emission and X-ray computed tomography, was used to detect and visualize damage accumulation in the specimens. It was found that decreasing the thickness of the 90° ply blocks reduced transverse matrix microcracking up to the point where no full-width transverse cracks developed prior to ultimate failure. A small degradation of the fibre direction failure strain in the central 0° plies was found as the 90°-layer thickness increased in the laminates, which corresponded with the development of edge/transverse cracks.

Tamas Rev↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the Moon. Although most Apollo samples are well characterized, several types of samples remain wholly or largely unstudied since their return: unopened and/or sealed drive tube samples, samples frozen upon return, and samples stored in a He-purged environment. NASA selected nine teams to participate in the Apollo Next Generation Sample Analysis (ANGSA) Program to study representative samples from each of these categories. The first sample studied as part of the ANGSA program is drive tube 73002, a 4 cm diameter unopened (but unsealed) drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube, and the bottom half of the tube (73001)was sealed under vacuum on the Moon (and will be studied next). As part of the preliminary examination of sample 73002, the entire drive tube was imaged with a high resolution X-ray Computed Tomography (XCT) scan prior to opening and dissecting the sample. Additionally, >50 XCT scans have been made of “large” clasts (>4 mm) removed from the core as part of the ongoing dissection process. Here we will present both the whole drive tube XCT data showing the overall structure of sample 73002 prior to dissection, as well as XCT scans of individual clasts that reveal the types and abundance of different lithologies present within the drive tube. We will also discuss the utility of the scans as part of the curation and preliminary examination process, as well as the potential for future science returns from the XCT scans.

Ryan A Zeigler↗

High Resolution Computed Tomography Inspection of Components Uncovers Root Causes of Vexing Failure Mysteries

During testing of actuators for fight programs, failures have occurred that required closure with an understanding of the root cause of the failure. For some InSight project actuators, intermittent changes of the winding resistance of the motors during temperature changes was extremely baffling. It was critical to determine the cause of the intermittent characteristic because the actuators were stock from a previous program and the company that provided the motors was no longer in business. Using an X-Ray Computed-Tomography (CT) method, the exact source of the intermittent failure was determined and completely understood – at dimensions of less than 20 microns. In another case, after the completion of an actuator’s life-test-to-failure, inspection was required to determine the source of the failure. The size of the actuator (10 mm diameter) required destructive means to get to the interior of the actuator for inspection, risking the loss of the source of the failure. Using CT imaging, the exact source of the failure was determined.

Johnson, Michael R.↗

Multi-frequency Tomography Radar Observations of Snow Stratigraphy at Fraser during SnowEx

SnowEx is a multi-year airborne snow campaign led by NASA. The purpose of SnowEx is to figure out how much water is stored in Earth’s terrestrial snow-covered regions. As part of the 2017 NASA SnowEx campaign, we deployed a portable triple-frequency (9.6GHz, 13.5GHz and 17.2GHz) and fully polarimetric frequency-modulated continuous-wave (FMCW) radar at Fraser, Colorado. The radar was installed on a 60cmx60cm frame to enable a full reconstruction of the three-dimensional variability per each radar channel. The tomography technique uses the radar echo from the multiple viewing positions and provides a unique access to the vertical structure of the snow layer. With current setup, the range resolution is 30cm. In this paper, we will review the radar design and signal-processing algorithm – time domain back projection. The generated vertical images show the snow stratigraphy, which is consistent with ground snow pit measurement. The continuous operation demonstrates diurnal thawing and refreezing process. The snow density is retrieved by comparing to the snow free image.

Esteban-Fernandez, Daniel↗

Computing the effective elasticity of anisotropic porous media from X-ray computed micro-tomography images

Development and optimization of composite materials designed for thermal protection of NASA’s spacecraft requires the understanding of their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the micro-scale on realistic representations of these composites. The digital micro-structures are generated either synthetically or through X-ray micro-tomography reconstructions. One of the main challenges in the prediction of heatshield material structural response is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the micro-scale. These are driven by the fiber layout within the micro-structure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled through the use of a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme. The MPSA, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA), was discussed in a previous presentation at the 15th USCCN and in reference. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Federico Semeraro↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present the whole tube and close-up XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

R A Zeigler↗

Exploring Oxidation in the Remote Free Troposphere: Insights From Atmospheric Tomography (ATom)

Earth's atmosphere oxidizes the greenhouse gas methane and other gases, thus determining their lifetimes and oxidation products. Much of this oxidation occurs in the remote, relatively clean free troposphere above the planetary boundary layer, where the oxidation chemistry is thought to be much simpler and better understood than it is in urban regions or forests. The NASA airborne Atmospheric Tomography study (ATom) was designed to produce cross sections of the detailed atmospheric composition in the remote atmosphere over the Pacific and Atlantic Oceans during four seasons. As part of the extensive ATom data set, measurements of the atmosphere's primary oxidant, hydroxyl (OH), and hydroperoxyl (HO2) are compared to a photochemical box model to test the oxidation chemistry. Generally, observed and modeled median OH and HO2 agree to within combined uncertainties at the 2σ confidence level, which is ~±40%. For some seasons, this agreement is within ~±20% below 6-km altitude. While this test finds no significant differences, OH observations increasingly exceeded modeled values at altitudes above 8 km, becoming ~35% greater, which is near the combined uncertainties. Measurement uncertainty and possible unknown measurement errors complicate tests for unknown chemistry or incorrect reaction rate coefficients that would substantially affect the OH and HO2 abundances. Future analysis of detailed comparisons may yield additional discrepancies that are masked in the median values.

atmosphere's primary oxidant, hydroxyl (OH), and h↗

Logical shadow tomography: Efficient estimation of error-mitigated observables

We introduce a technique to estimate error-mitigated expectation values on noisy quantum computers. Our technique performs shadow tomography on a logical state to produce a memory-efficient classical reconstruction of the noisy density matrix. Using efficient classical post-processing, one can mitigate errors by projecting into the codespace as in subspace expansion and taking powers of the density matrix as in virtual distillation. Relative to subspace expansion which requires Ω (2^((n-1)k) samples to estimate a Pauli observable with an [[n; k]] stabilizer code, our technique requires only Ө(2^k) samples. Relative to virtual distillation, our technique can compute powers of the density matrix without implementing additional copies of quantum states the quantum computer. We present numerical results using logical states encoded with up to sixty physical qubits and show fast convergence to error-free expectation values with only 10^5 samples under 1% depolarizing noise.

quantum computing↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗

Characterizing Char Rate and Extent in Fiber-Reinforced Plastics Using X-ray Computed Tomography

Orbital debris is a growing problem for the space industry and the world in general, and an important component of the problem is what happens when that debris reenters the Earth’s atmosphere. With more spacecraft opting for fiber-reinforced polymer (FRP) components, we need to understand the thermal destruction process of these materials during an atmospheric reentry and how much of the material can survive to impact the ground. The NASA Orbital Debris Program Office (ODPO) has developed a new charring model for FRP components to be integrated into the latest version of the Object Reentry Survival Analysis Tool (ORSAT). To validate this new model, the ODPO performed several test series using the Inductively Coupled Plasma (ICP) Torch facility at UT Austin. To measure the extent of charred material at different conditions, some of the test samples were scanned using x-ray computed tomography (CT) by the Astromaterials Curation Lab at Johnson Space Center. 3D image analysis was then used to calculate the volume and density of the char in each test sample. This paper presents the image analysis methodology, an assessment of the accuracy of the data analysis, and a comparison with calculations using the ORSAT charring model.

Benton Greene↗

Atom Probe Tomography and Three-Dimensional Atomic Scale Characterisation of Interplanetary Dust Particles: Inorganic and Organic, Hydrous and Anhydrous Assemblages

Interplanetary dust particles (IDPs)preserve primordial fragments from our Solar System and external stellar systems, sampled from a vast range of dust forming bodies that often display smaller degrees of parent body processing than is seen in meteorites. IDPs preserve some of the smallest astromaterials from our Solar System, many of which are believed to be among the most important materials for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium (ISM), Solar Nebula and external planetary systems[1]. However, their formation processes and provenance are poorly constrained, owing in part to spatial resolution limitations of traditional analytical techniques. Atom probe tomography (APT) uses a pulsed laser to field-evaporate material at the atomic scale from needle-shaped samples, and time-of-flight spectrometry for 3D reconstruction of element and isotope distribution in samples after data acquisition. This technique has the highest spatial resolution available of any technique used within the geoscience field[2]. However, measuring multi-phase specimens and porous media in APT can be challenging, two primary characteristics of IDPs. Here we present a custom method for APT needle design and the first results of a 3Datomic scale study of interplanetary dust particles, salt crystals and extraterrestrial insoluble and soluble organic matter designed to overcome the challenges of studying IDP-like materials.

N D Nevill↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗