Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Model For the Limiting Time in Vortex Ring Formation

In another presentation, Gharib et at provide experimental results to show that when a vortex ring is created from a pipe by a piston, there is a limiting time or piston stroke length beyond which multiple rings appear. This time appeared to be insensitive to piston velocity history and Reynolds number. Nature might exploit such a. limit in different contexts to coherently deliver mass or momentum flux with the least number of strokes. Here, a simple hypothesis is considered: the limiting time occurs when the apparatus is no longer able to deliver energy at a rate compatible with the requirement, due to Kelvin, that a steady vortex ring have maximum energy given circulation and impulse. More specifically, the limit is expected to occur when the quantity alpha = E/square root of Gamma(sup 3)I delivered by the piston drops below the value, alpha(sub lim) for a limiting steady vortex ring solution. The resulting predictions agree very well with the experiments (after using alpha(sub lim) measured using the experimental flow fields). The insensitivity to piston history also emerges from the model. Finally, piston histories are designed that may extend the limiting time somewhat.

Shariff, Karim↗

Deadtime Determination of Helium Detector Using MCNP Code

In detector systems, the minimum time separation between the events is called detector's deadtime. The The intrinsic properties of the detector and the pulse processing circuitry's characteristics are the sources of deadtime. Researchers have been working on improving a detector deadtime model that can implicitly characterize a detection system's behavior while reducing counting errors. There are two commonly known dead-time models: the 'Paralyzing' and the 'Non-paralyzing' models. In reality, detection systems fit neither of these idealized models perfectly, instead falling somewhere between the two models. The paralyzing model is mathematically expressed by eq. 1, where m is the measured count rate, n is the true count rate and t is dead-time. This model assumes that each event during the dead-time will reset it to a fixed duration, thus extending the deadtime. The dead-time extension depends on the count rate. According to the non-paralyzing model, deadtime is fixed after each detected event, and all events occurring during deadtime are lost. The fraction of time during which an apparatus is sensitive is 1-mt. Therefore, the fraction of the true number of events can be recorded. In this study, a Canberra {sup 3}He neutron detector (0.5NH1/1K) deadtime value was estimated using a combination of experimental subcritical assembly measurements and theoretical MCNP simulations. The deadtime of the Canberra 10 mm diameter {sup 3}He tube detector was calculated by comparing measured counts from different locations in the subcritical assembly at Missouri University of Science and Technology Reactor (MSTR) with MCNP (Monte Carlo N-Particle Code) simulations. The deadtime calculations are provided for both the paralyzing and non-paralyzing models for the Canberra 10 mm diameter {sup 3}He tube detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined photoionization time-of-flight mass spectrometry and laser absorption spectrometry flash photolysis apparatus for simultaneous determination of reaction rates and product branching

In recent years, predictions of product branching for reactions of consequence to both combustion and atmospheric chemistry have outpaced validating experiments. An apparatus is described that aims to fill this void by combining several well-known experimental techniques into one: flash photolysis for radical generation, multiple-pass laser absorption spectrometry (LAS) for overall kinetics measurements, and time-resolved photoionization time-of-flight mass spectrometry (PI TOF-MS) for product branching quantification. The sensitivity of both the LAS and PI TOF-MS detection techniques is shown to be suitable for experiments with initial photolytically generated radical concentrations of ~1 × 10 12 molecules cm -3 . As it is fast (μs time resolution) and non-intrusive, LAS is preferred for accurate kinetics (time-dependence) measurements. By contrast, PI TOF-MS is preferred for product quantification because it provides a near-complete picture of the reactor composition in a single mass spectrum. The value of simultaneous LAS and PI TOF-MS detection is demonstrated for the chemically interesting phenyl radical + propene system.

47 OTHER INSTRUMENTATION↗

Time Triggered Ethernet System Testing Means and Method

Methods and apparatus are provided for evaluating the performance of a Time Triggered Ethernet (TTE) system employing Time Triggered (TT) communication. A real TTE system under test (SUT) having real input elements communicating using TT messages with output elements via one or more first TTE switches during a first time interval schedule established for the SUT. A simulation system is also provided having input simulators that communicate using TT messages via one or more second TTE switches with the same output elements during a second time interval schedule established for the simulation system. The first and second time interval schedules are off-set slightly so that messages from the input simulators, when present, arrive at the output elements prior to messages from the analogous real inputs, thereby having priority over messages from the real inputs and causing the system to operate based on the simulated inputs when present.

Smithgall, William Todd↗

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Native Fluorescence Detection Methods and Detectors for Naphthalene and/or Other Volatile Organic Compound Vapors

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds have been identified as serious health hazards. This is especially true for personnel working with JP8 jet fuel and other fuels containing naphthalene as well as other hazardous volatile organic compounds (VOCs). Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to naphthalene or other hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined. The badges employ a new native fluorescence based detection method to identify and differentiate VOCs. The particular focus of some embodiments are the detection and identification of naphthalene while other embodiments are directed to detection and identification of other VOCs like aromatic hydrocarbons such as benzene, toluene, and xylene.

Hug, William F.↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Scaling microstructural processes in the sintering of ionic ceramics

A multi-scale framework, combining a multiphase field formulation and large deformation mechanics, was developed as a stepping stone to perform the data analytics of the microstructural level kinetics of a sintering solid. Relevant microstructural information from this framework, such as grain, stress, and porosity statistics, was scaled up to describe the macroscopic level sintering kinetics. Here, the developed formulation was applied to describe the electric field assisted sintering of Y 2 O 3 . Microstructural inhomogeneities in a multi-granular solid result in the formation of a field of compressive stress networks, which interleave with low compression and weakly tensile regions, defining a scaffolding for sintering concentration regions to develop. A Poisson effect-induced lateral stress network is also naturally self-induced as a result of the mechanical constraints imposed by the sintering apparatus. For long sintering times, localized shear stresses enhancing mass flow along grain boundaries and internal surfaces develop. Three-sided pores are removed by either vacancy transport to the surrounding pores, or move towards the external surfaces through grain boundary diffusion. Four- and higher order-sided pores stabilize because an equal amount of vacancies are gained and lost through the connecting grain boundaries. Grain dewetting contributes to pore coalescence, suggesting that pore kinetics and grain growth are coupled and should be analyzed in concert. The combined sintering and grain growth kinetics define six regimes of sintering behavior: (1) T, the transient regime; (2) E$_Υ$, the surface energy dominated, early sintering regime, where the grain growth exponent, p = 1, and the stress concentration factor, $f$ ~ $1/\hat{ρ}^{4.6}$; (3) E S , the stress dominated, early sintering regime, where p = 1 and $f$ ~ $1/\hat{ρ}^{4}$; (4) I$_Υ$, the surface energy dominated, intermediate sintering regime, where p = 2 and $f$ ~ $1/\hat{ρ}^{4.6}$; (5) I S , the stress dominated, intermediate sintering regime, where p = 2 and $f$ ~ $1/\hat{ρ}^{4}$; and (6) L, the late sintering regime, where p = 3 and $f$ ~ 1. At the macroscopic level, the rapid densification and suppression of grain growth observed in the electric field assisted sintering process is a consequence of the compounding effects of the underlying stress-, transport-, and interfacial-energy-induced energy minimization kinetics, as predicted by the multi-scale framework.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shear strength and permeability of the cement-casing interface

Here, the shear strength and hydraulic permeability of the interface between well cement and casing was investigated using a triaxial direct shear apparatus. For the first time, these experiments provide measurements under controlled stress conditions with fluid flow measurements along the interface. The low cohesion (1.1 ± 1.1 MPa) and the high friction angle (43.4 ± 2.0°) indicates that the shear strength of the interface is provided by friction. This implies that the state of stress of the cement is critical to well integrity. The hydraulic aperture of the undamaged cement-steel samples was 6.8 ± 1.0 microns. Shear damage to the interface caused a decrease (-20 %) in hydraulic aperture for samples aged up to 1 month, and an increase (+300 %) for samples cured for two years. We performed numerical simulations to estimate the leakage potential from a carbon storage operation. This model predicts negligible leakage amounts (47 tonnes) in a shear-damaged well for the modeled injection of ~1.26 million tonnes of CO 2 . Thus, our measurements indicate that the cement-casing interface is not a significant leakage pathway in its intact or damaged state, and that shear-driven failure scenarios for this interface are not a significant risk to CO 2 storage security.

54 ENVIRONMENTAL SCIENCES↗

Study of hot tearing of A206 aluminum alloy using Instrumented Constrained T-shaped Casting method

The hot tearing susceptibility of A206 aluminum alloy was investigated using Instrumented Constrained T-shaped Casting method and the effect of the casting temperature on hot tearing was studied. The Instrumented Constrained T-shaped Casting apparatus enabled real-time measurements of the contraction load developed in the casting and the temperature variations during solidification as a function of time. Critical temperatures and points during solidification of the castings were extracted from these data. The contraction load developed at the coalescence point of the castings was identified as a comparative criterion for predicting the hot tearing susceptibility of the alloys which could be utilized even when no visual tearing had occurred. The results showed that hot tearing susceptibility increased with the casting temperature. This was associated with reduced cooling rate, increased solute segregation and more localized hot spot formation at the T-junction area. Increase in the casting temperature also increased the grain size which may in turn have affected the initiation of the hot tears. The visual observations were further validated with radiographic tests.

36 MATERIALS SCIENCE↗

Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further development of chemical vapor deposition process for production of large diameter carbon-base monofilaments

The development of large diameter carbon-base monofilament in the 50 micron to 250 micron diameter range using the chemical vapor deposition process is described. The object of this program was to determine the critical process variables which control monofilament strength, monofilament modulus, and monofilament diameter. It was confirmed that wide scatter in the carbon substrate strength is primarily responsible for the scatter in the monofilament strength. It was also shown through etching experiments that defective substrate surface conditions which can induce low strength modular growth in the monofilament layers are best controlled by processing improvements during the synthesis of the substrate. Modulus was found to be linearily proportional to monofilament boron content. Filament modulus was increased to above 27.8MN/sq cm but only by a considerable increase in monofilament boron content to 60 wt. % or more. Monofilament diameter depended upon dwell time in the synthesis apparatus. A monofilament was prepared using these findings which had the combined properties of a mean U.T.S. of 398,000 N/sq cm, a modulus of 18.9 MN/sq cm (24,000,000 psi), and a diameter of 145 microns. Highest measured strength for this fiber was 451,000 N/sq cm (645,000 psi).

Hough, R. L.↗

Further development of a biocide generation and water system passification system addendum

An electrochemical process for generating iodine in situ in a potable water metallic storage system was examined. The degree of concurrent corrosion protection and of metallic ion buildup was determined. A working metal bellows system was evaluated and tested for the buildup of metallic ions comparable to that reported in spacecraft potable water specifications. An integrated system was assembled and tested which may be used to maintain the potability of water which is passively stored in metallic containers for extended periods of time. Test conditions and apparatus are described.

Source record↗

An apparatus and procedure for evaluating the toxic hazards of smoldering seating and bedding materials

An apparatus and procedure are described for evaluating the toxicity of the gases evolved from the smoldering combustion of seating and bedding materials. The method combines initiation of smoldering combustion in fabric/cushion combinations by a lighted cigarette and exposure of laboratory animals to the gases evolved. The ratio of the surface available for smoldering to the compartment volume in this apparatus is approximately five times the ratio expected in a California living room, and 100 times the ratio expected in a wide-body aircraft passenger cabin. Based on fabric/cushion combinations tested, the toxicity of gases from smoldering combustion does not appear to be a significant hazard in aircraft passenger cabins, but seems to be a basis for careful selection of materials for residential environments.

Hilado, C. J.↗