Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THOMSON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

First measurement of time evolution of electron temperature profiles with Nd:YAG Thomson scattering system on Heliotron J

A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (n{sub e} ∼ 0.5 × 10{sup 19} m{sup −3}). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma may be possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Thomson scattering measurements of cylindrical wire array parameters

A Thomson scattering diagnostic has been used to measure the parameters of cylindrical wire array Z pinch plasmas. The scattering operates in the collective regime ({alpha}>1) allowing spatially localised measurements of the ion or electron plasma temperatures and of the plasma bulk velocity. The ablation flow is found to accelerate towards the axis reaching peak velocities of 1.2-1.3 Multiplication-Sign 10{sup 7} cm/s in aluminium and {approx}1 Multiplication-Sign 10{sup 7} cm/s in tungsten arrays. Measurements of the precursor ion temperature shortly after formation are found to correspond to the kinetic energy of the converging ablation flow. Measurements during the implosion phase of tungsten arrays show the main imploding mass reaches velocities of {approx}1.4-1.7 Multiplication-Sign 10{sup 7} cm/s and is non-zero even at large radii close to the start of the x-ray pulse indicating current flow in the trailing mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak

A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tangential System of Thomson Scattering for Tokamak T-15

Two systems of Thomson scattering diagnostics, with vertical and tangential probing, are used in the D-shaped plasma cross section in tokamak T-15. The tangential system allows measuring plasma temperature and density profiles along the major radius of the tokamak. This paper presents the tangential system project. The system is based on a Nd:YAG laser with wavelength of 1064 nm, pulse energy of 3 J, pulse duration of 10 ns, and repetition rate of 100 Hz. The chosen geometry allows collecting light from ten uniformly spaced points. Optimization of the registration system has been accomplished. The collected light will be transmitted through an optical fiber bundle with diameter of 3 mm and quartz fibers (numerical aperture is 0.22). Six-channel polychromators based on high-contrast interference filters have been chosen as spectral equipment. The radiation will be registered by avalanche photodiodes. The technique of electron temperature and density measurement is described, and estimation of its accuracy is carried out. The proposed system allows measuring the electron temperature with accuracy not worse than 10% within the range of 50 eV to 10 keV on the pinch edge over the internal contour, from 20 eV to 9 keV in the plasma central region, and from 2 eV to 400 eV on the pinch edge over the outer contour. The estimation is made for electron density of not less than 2.6 × 10{sup 13} cm{sup –3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson-scattering measurements in the collective and noncollective regimes in laser produced plasmas (invited)

We present simultaneous Thomson-scattering measurements of light scattered from ion-acoustic and electron-plasma fluctuations in a N{sub 2} gas jet plasma. By varying the plasma density from 1.5x10{sup 18} to 4.0x10{sup 19} cm{sup -3} and the temperature from 100 to 600 eV, we observe the transition from the collective regime to the noncollective regime in the high-frequency Thomson-scattering spectrum. These measurements allow an accurate local measurement of fundamental plasma parameters: electron temperature, density, and ion temperature. Furthermore, experiments performed in the high densities typically found in laser produced plasmas result in scattering from electrons moving near the phase velocity of the relativistic plasma waves. Therefore, it is shown that even at low temperatures relativistic corrections to the scattered power must be included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detecting non-Maxwellian electron velocity distributions at JET by high resolution Thomson scattering

The present work is motivated by a long standing discrepancy between the electron temperature measurements of Thomson scattering (TS) and electron cyclotron emission (ECE) diagnostics for plasmas with strong auxiliary heating observed at both JET and TFTR above 6-7 keV, where in some cases the ECE electron temperature measurements can be 15%-20% higher than the TS measurements. Recent analysis based on ECE results at JET has shown evidence of distortions to the Maxwellian electron velocity distribution and a correlation with the TS and ECE discrepancies has been suggested. In this paper, a technique to determine the presence of non-Maxwellian behavior using TS diagnostics is outlined. The difficulties and limitations of modern TS system designs to determine the electron velocity distribution are also discussed. It is demonstrated that small deviations such as those suggested by previous ECE analysis could be potentially detected, depending on the spectral layout of the TS polychromators. The spectral layout of the JET high resolution Thomson scattering system is such that it could be used to determine these deviations between 1 and 6 keV, and the results presented here indicate that no evidence of non-Maxwellian behavior is observed in this range. In this paper, a modification to the current polychromator design is proposed, allowing non-Maxwellian distortions to be detected up to at least 10 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A reflective optical transport system for ultraviolet Thomson scattering from electron plasma waves on OMEGA

A reflective optical transport system has been designed for the OMEGA Thomson-scattering diagnostic. A Schwarzschild objective that uses two concentric spherical mirrors coupled to a Pfund objective provides diffraction-limited imaging across all reflected wavelengths. This enables the operator to perform Thomson-scattering measurements of ultraviolet (0.263 {mu}m) light scattered from electron plasma waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional Thomson scattering measurements of misaligned electron density and temperature gradients and associated Biermann battery produced fields

We present optical Thomson scattering measurements of electron density and temperature in high Mach number laser-driven blast waves in homogeneous gases. Taylor–Sedov blast waves are launched in nitrogen (N2) or helium (He) at pressures between 0.4 mTorr and 10 Torr by ablating a solid plastic target with a high energy laser pulse (10 J, 1012 W/cm2). Experiments are performed at high repetition rate (1 Hz), which allows one-dimensional and two-dimensional Thomson scattering measurements over an area of several cm2 by automatically translating the scattering volume between shots. Electron temperature and density in the blast wave fronts were seen to increase with increasing background gas pressure. Measured electron density and temperature gradients were used to calculate ∂B/∂t∝∇Te×∇ne. The experimentally measured ∂B/∂t showed agreement with the magnetic field probe (B-dot) measurements, revealing that magnetic fields are generated in the observed blast waves via the Biermann battery effect. The results are compared to numerical three-dimensional collisional magnetohydrodynamic simulations performed with FLASH, and are discussed in the context of spontaneous magnetic field generation via the Biermann battery effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A pulse-burst laser system for Thomson scattering on NSTX-U

A pulse-burst laser system has been built for Thomson scattering on NSTX-U, and is currently being integrated into the NSTX-U Thomson scattering diagnostic system. The laser will be operated in three distinct modes. The base mode is continuous 30 Hz rep rate, and is the standard operating mode of the laser. The base mode will be interrupted to produce a "slow burst" (specified 1 kHz rep rate for 50 ms) or a "fast burst" (specified 10 kHz rep rate for 5 ms). The combination of base mode→ interruption→ burst mode is new and has not been implemented on any previous pulse-burst laser system. Laser pulsing is halted for a set period (~ 1 minute) following a burst to allow the YAG rods to cool; this type of operation is called a heat-capacity laser. The laser is Nd:YAG operated at 1064 nm, q-switched to produce ≥ 1.5 J pulses with ~ 20 ns FWHM. It is flashlamp pumped, with dual-rod oscillator (9 mm) and dual-rod amplifier (12 mm). Variable pulsewidth drive of the flashlamps is accomplished by IGBT (insulated gate bipolar transistor) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction. The laser system has demonstrated compliance with all specifications, and is capable of exceeding design specifications by significant margins, e.g., higher rep rates for longer burst periods. Burst operation of this laser system will be used to capture fast time evolution of the electron temperature and density profiles during events such as ELMs, the L-H transition, and various MHD modes.

47 OTHER INSTRUMENTATION↗

Commissioning and operation of a real-time multi-point Thomson scattering evaluation system at Wendelstein 7-X

A real-time multi-point Thomson scattering (rtMPTS) evaluation system has recently been installed and commissioned at the Wendelstein 7-X (W7-X) stellarator during the 2024 -2025 operational phases. This system has demonstrated successful evaluation of Thomson scattered spectra on millisecond timescales. We discuss initial results from this system, consisting of a comparison of different evaluation techniques, assessment of system evaluation times, and proof-of-principle control experiments carried out with the W7-X poloidal correlation reflectometer (PCR) system. This diagnostic represents the first step towards the development of a density profile controller at W7-X, which can be leveraged to support steady-state operation.

Mohammed, Ameer [Princeton Plasma Physics Laborato↗

First measurement of electron temperature from signal ratios in a double-pass Thomson scattering system

This paper presents an experimental demonstration to determine electron temperature (T{sub e}) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T{sub e} can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T{sub e} measured from the ratio (T{sub e,r}) and T{sub e} measured from a standard method (T{sub e,s}) showed a good agreement with <|T{sub e,r}-T{sub e,s}|/T{sub e,s}>= 7.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental observation of polarization-resolved nonlinear Thomson scattering of elliptically polarized light

We report experimental results from a study of nonlinear Thomson scattering of elliptically polarized light. Polarization-resolved radiation patterns of the scattered light are measured as a function of the elliptical polarization state of the incident laser light. The relativistic electron trajectory in intense elliptically polarized fields leads to the formation of unique radiated polarization states, which are observed by our measurements and predicted by a theoretical model. The polarization of Thomson scattered light depends strongly on the intensity of the incident light due to nonlinearity. The results are relevant to high-field electrodynamics and to research and development of light sources with novel capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results of electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10

A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Thomson scatter from a laser-ablated magnesium plume

We have carried out an optical Thomson scatter study of a KrF laser-ablated Mg plume. The evolution of the electron temperature and density at distances 2-5 mm from the target surface has been studied. We have observed that the electron density falls more rapidly than the atomic density and believe that this is a result of rapid dielectronic recombination. A comparison of the electron density profile and evolution with simple hydrodynamic modeling indicates that there is a strong absorption of the laser in the plasma vapor above the target, probably due to photoionization. We also conclude that an isothermal model of expansion better fits the data than an isentropic expansion model. Finally, we compared data obtained from Thomson scatter with those obtained by emission spectroscopy under similar conditions. The two sets of data have differences but are broadly consistent.

36 MATERIALS SCIENCE↗

Dual-angle, self-calibrating Thomson scattering measurements in RFX-MOD

In the multipoint Thomson scattering (TS) system of the RFX-MOD experiment the signals from a few spatial positions can be observed simultaneously under two different scattering angles. In addition the detection system uses optical multiplexing by signal delays in fiber optic cables of different length so that the two sets of TS signals can be observed by the same polychromator. Owing to the dependence of the TS spectrum on the scattering angle, it was then possible to implement self-calibrating TS measurements in which the electron temperature T{sub e}, the electron density n{sub e} and the relative calibration coefficients of spectral channels sensitivity C{sub i} were simultaneously determined by a suitable analysis of the two sets of TS data collected at the two angles. The analysis has shown that, in spite of the small difference in the spectra obtained at the two angles, reliable values of the relative calibration coefficients can be determined by the analysis of good S/N dual‑angle spectra recorded in a few tens of plasma shots. This analysis suggests that in RFX-MOD the calibration of the entire set of TS polychromators by means of the similar, dual-laser (Nd:YAG/Nd:YLF) TS technique, should be feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Fast, Near-Infrared Photodetectors for the ITER Core LIDAR Thomson Scattering

A key component for the ITER core LIDAR Thomson Scattering (TS) diagnostic would be a detector with good sensitivity in the 850-1060 nm near infrared (NIR) spectral region. Covering this spectral region becomes necessary if a Nd:YAG laser system operating at {lambda} = 1.06 {mu}m is used as the laser source, which is a very attractive choice in terms of available energy, repetition rate, reliability and cost. In this paper we review the state of the art of two types of detectors available for the above spectral range: the transferred electron (TE) InGaAs/InP hybrid photodiode and the In{sub x}Ga{sub 1-x}As microchannel plate (MCP) image intensifier and we describe the advancements necessary for a possible application in the ITER LIDAR TS. In addition we describe the preliminary characterization of new GaAsP fast MCP photomultipliers (PMTs) suitable for the detection of the visible part of the LIDAR TS spectrum in JET and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The development of Thomson scattering system on HL-2A tokamak

A new Thomson scattering diagnostic system is successfully developed to measure core plasma electron temperature (T{sub e}) and density (n{sub e}) of HL-2A tokamak (major radius R=165 cm, minor radius a=40 cm). In this system, a standard lamp-monochromator combination is utilized for the calibration of spectral responses. By sweeping in the range of 750-1200 nm with a step of 2 nm, the work can be done automatically for one-point calibration and then for other. Electronic gain calibration and gain monitoring are done by pulsed light emitting diode light. By utilizing an intense Nd:YAG laser of pulse energy up to 4 J and employing good quality interference filters in the five-channel filter polychromator to surpress greatly the stray light, the TS system can be routinely used to make measurements with good quality data. After each HL-2A plasma discharge, the measured T{sub e} and n{sub e} data are transferred to HL-2A database for lookup and analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High sensitivity imaging Thomson scattering for low temperature plasma

A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a ''Generation III'' image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n{sub e}) and 6% in the electron temperature (T{sub e}) at n{sub e}=4x10{sup 19} m{sup -3}. This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9x10{sup 17} m{sup -3} in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n{sub e} and T{sub e} measurement is 7x10{sup 20}/n{sub e} J, which means that single shot measurements are possible for n{sub e}>2x10{sup 21} m{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗