Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMIONIC EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ion and advanced electric thruster research

A phenomenological model of the orificed, hollow cathode based on the field enhanced, thermionic mechanism of electron emission is presented. High frequency oscillations associated with the orificed, hollow cathode are shown to be a consequence of current flow through the cathode orifice. A procedure for Langmuir probing of the hollow cathode discharge and analyzing the resulting probe characteristics is discussed. The results of sputter yield measurements made for molybdenum, tantalum, type 304 stainless steel and copper surfaces being bombarded by low energy argon or mercury ions are also given. The effects of nitrogen and alternated copper layers on the sputter yields of molybdenum, tantalum and 304 stainless steel are also discussed. A dynamic model of electrothermal rocket and ramjet thrusters is developed. The gross performance of these devices is compared to that of an electromagnetic gun for the case of a high acceleration, Earth launch mission. The theoretical performance of electrothermal rockets and ramjets is shown to be comparable to that of the electromagnetic gun.

Wilbur, P. J.↗

Discovery of Stable Surfaces with Extreme Work Functions by High‐Throughput Density Functional Theory and Machine Learning

Abstract The work function is the key surface property that determines the energy required to extract an electron from the surface of a material. This property is crucial for thermionic energy conversion, band alignment in heterostructures, and electron emission devices. This work presents a high‐throughput workflow using density functional theory (DFT) to calculate the work function and cleavage energy of 33,631 slabs (58,332 work functions) that are created from 3,716 bulk materials. The number of calculated surface properties surpasses the previously largest database by a factor of ≈27. Several surfaces with an ultra‐low (<2 eV) and ultra‐high (>7 eV) work function are identified. Specifically, the (100)‐Ba‐O surface of BaMoO 3 and the (001)‐F surface of Ag 2 F have record‐low (1.25 eV) and record‐high (9.06 eV) steady‐state work functions. Based on this database a physics‐based approach to featurize surfaces is utilized to predict the work function. The random forest model achieves a test mean absolute error (MAE) of 0.09 eV, comparable to the accuracy of DFT. This surrogate model enables rapid predictions of the work function (≈ 10 5 faster than DFT) across a vast chemical space and facilitates the discovery of material surfaces with extreme work functions for energy conversion and electronic device applications.

97 MATHEMATICS AND COMPUTING↗

Electronic structure of BaO/W cathode surfaces

The local electronic structure of the emissive layer of barium dispenser thermionic cathodes is investigated theoretically using the relativistic scattered-wave approach. The interaction of Ba and O with W, Os, and W-Os alloy surfaces is studied with atomic clusters modeling different absorption environments representative of B- and M-type cathodes. Ba is found to be strongly oxidized, while O and the metal substrate are in a reduced chemical state. The presence of O enhances the surface dipole and Ba binding energy relative to Ba on W. Model results for W-Os alloy substrates show only relatively small changes in Ba and O for identical geometries, but very large charge redistributions inside the substrate, which are attributed to the electronegativity difference between Os and W. If Os is present in the surface layer, the charge transfer from Ba to the substrate and the Ba binding energy increase relative to W. Explanations are offered for the improved electron emission from alloy surfaces and the different emission enhancement for different alloy substrates.

Muller, Wolfgang↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Status of research on advanced thermionic converters

It is shown that it is possible to controllably and continuously elevate the electron temperature in the plasmatron thermionic energy converter from the emitter temperature to the maintenance electron temperature for the diode arc mode. This ability and the apparent validity of an elementary analytical model of the plasma should make possible the optimization and evaluation of operation under strong ionization conditions for which the plasma resistance should be acceptably low. Measurement of the vacuum space charge arising from the emission from a surface in cesium vapor indicates the presence of a substantial negative ion emission current. Apparatus has been constructed for identifying and directly measuring the flux of positive, negative and neutral species emitted from an electrode surface in a cesium vapor diode. The primary purpose of the investigation is to determine the influence of negative ion emission on the effective work function of thermionic converter electrodes. Initial data indicate the presence of H(-), Cs(-) and possibly C(-) and CH(-).

Hatch, G. L.↗

Material development for thermionic fuel-cladding systems.

Fuel-cladding systems capable of maintaining stable dimension and electron emission characteristics at high temperatures under irradiation are essential to the successful operation of nuclear thermionic power sources. Studies regarding two possible systems, involving tungsten clad uranium carbide and uranium oxide, are considered. Out-of-pile developmental efforts and the in-pile evaluation results for the two systems are described. Prototypical emitters have been tested for 8000 hours for the carbide system and 4000 hours for the oxide system.

Yang, L.↗

A sub-cm micromachined electron microscope

A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance.

Feinerman, A. D.↗

Electron emission from nickel-alloy surfaces in cesium vapor

The cesiated electron emission was measured for three candidate electrodes for use as collectors in thermionic converters. Nickel, Inconel 600 and Hastelloy were tested with a 412 K cesium reservoir. Peak emission from the alloys was found to be comparable to that from pure nickel. Both the Inconel and the Hastelloy samples had work functions of 1.64 eV at peak emission. The minimum work functions were estimated to be 1.37 eV at a probe temperature of 750 K for Inconel and 1.40 eV for Hastelloy at 665 K. The bare work function for both alloys is estimated to be approximately the same as for pure nickel, 4.8 eV.

Manda, M.↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

High efficiency thermionic converter studies

The objective is to improve thermionic converter performance by means of reduced interelectrode losses, greater emitter capabilities, and lower collector work functions until the converter performance level is suitable for out-of-core space reactors and radioisotope generators. Electrode screening experiments have identified several promising collector materials. Back emission work function measurements of a ZnO collector in a thermionic diode have given values less than 1.3 eV. Diode tests were conducted over the range of temperatures of interest for space power applications. Enhanced mode converter experiments have included triodes operated in both the surface ionization and plasmatron modes. Pulsed triodes were studied as a function of pulse length, pulse potential, inert gas fill pressure, cesium pressure, spacing, emitter temperature and collector temperature. Current amplifications (i.e., mean output current/mean grid current) of several hundred were observed up to output current densities of one amp/sq cm. These data correspond to an equivalent arc drop less than 0.1 eV.

Huffman, F. N.↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗