Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Structured Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms

The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. Here In this study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.

36 MATERIALS SCIENCE↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid- following inverter↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid-following inverter↗

Multi-Resolution UAV Path Replanning for Inspection of Tailings Dams

Autonomous inspection of large and complex structures with a commercial unmanned aerial vehicle (UAV) is a challenging problem that has been addressed in recent years. In this paper, we address the global motion planning problem of creating autonomous inspection missions for UAVs considering photogrammetry constraints. We focus on the inspection of large tailings dams, which are dam structures used to store waste byproducts of mining. Our method uses a prior sparse point cloud of the dam to generate a voxel grid, where paths satisfying photogrammetry constraints are tested for collisions. We then apply the A* algorithm as a local planner to avoid obstacles within the global mission. Moreover, we address the problem of changing routes online by using octree-based multi-resolution grids for efficient and fast pathfinding. Our results, obtained using tridimensional maps of an actual coal mine tailings dam, show that using octrees for multi-resolution motion planning is faster than using a fixed voxel grid in online missions while inspecting large structures.

42 ENGINEERING↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Medium Voltage Energy Hub Based on Multilevel Cascaded H Bridge-Dual Active Bridge Back-to-Back Converter for Power Distribution Feeders Interconnection and Multiple Simultaneous Grid Services

This paper presents a medium voltage energy hub based on a modular design of a multilevel cascaded H bridge (CHB)-dual active bridge (DAB) converter. The energy hub composed of the two CHB-DAB modules with a back-to-back topology can be utilized as a grid interconnection component between distribution feeders. The energy hub can provide multiple simultaneous grid services such as voltage regulation, power factor correction, as well as active power flow control between the connected feeders, contributing to grid flexibility, efficiency, reliability, and resilience. Circuit structure and control schemes for the energy hub including both local controllers for each converter and outer loop controllers are proposed to enable simultaneous grid services with coordination to prevent the overloading of the hub. To validate the performance of the hub, the hub system is interconnected between two IEEE 4-bus feeders and provides voltage regulation for both feeders, while controlling active power flow between them. The system and the feeders are implemented in Real-Time Digital Simulator (RTDS) for real-time simulation verification.

Choi, Jongchan↗

A Practical Introduction to Common Grid Architecture Techniques

The focus of this white paper is to understand the uses and benefits of the practice of Grid Architecture from various stakeholder perspectives. It introduces a few selected Grid Architecture techniques based on their centrality to understanding key structural considerations and their linkage to emerging trends in electricity infrastructure. However, Grid Architecture has many dimensions, some of which exceed the scope of this limited work. This document is a work of the GridWise Architecture Council (GWAC). It is based on guidance from GWAC's Grid Architecture working group members of which have been acknowledged in the document.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial Intelligence Techniques in Smart Grid: A Survey

The smart grid is enabling the collection of massive amounts of high-dimensional and multi-type data about the electric power grid operations, by integrating advanced metering infrastructure, control technologies, and communication technologies. However, the traditional modeling, optimization, and control technologies have many limitations in processing the data; thus, the applications of artificial intelligence (AI) techniques in the smart grid are becoming more apparent. This survey presents a structured review of the existing research into some common AI techniques applied to load forecasting, power grid stability assessment, faults detection, and security problems in the smart grid and power systems. It also provides further research challenges for applying AI technologies to realize truly smart grid systems. Finally, this survey presents opportunities of applying AI to smart grid problems. The paper concludes that the applications of AI techniques can enhance and improve the reliability and resilience of smart grid systems.

energy systems↗

Flow field characteristics of a 127-pin rod bundle with hexagonal spacer grids

A determination of nominal flow phenomena in liquid metal fast reactor (LMFR) fuel assemblies is critical toward generation-IV reactor development. Axially positioned spacer grids are used to maintain the geometry of hexagonal rod bundles and simultaneously introduce perturbations in the flow. Three-dimensional (3D) printed asymmetric honeycomb spacer grids were installed in a prototypical 127-pin LMFR fuel assembly model to study complex fluid dynamics interactions induced by the spacer grid and rods. To characterize flow dynamics in this intricate geometry, time-resolved particle image velocimetry (TR-PIV) using the matched-index-of-refraction method was employed to obtain non-intrusive velocity measurements for three axial planes (one near-wall and two interior planes) at a Reynolds number of 6000. The statistical TR-PIV results compared sub-channel-dependent normalized time-averaged velocity, velocity fluctuations, Reynolds stress, vorticity, and turbulence kinetic energy distributions. TR-PIV line profiles characterized downstream spacer grid flow dynamics. Two-point spatial and spatial–temporal cross-correlation fields revealed local coherent structures and quantified convection velocities of traveling vortices. Spatial–temporal decomposition using dynamic mode decomposition (DMD) applied to the near-wall vorticity fields extracted turbulent structures and flow instabilities in the wake region of the spacer grid, along with their decay and frequency rates. Reduced-order velocity fields from DMD reconstructions identified the most energy-containing coherent structures persistent in the near-wall region. This research provides experimental data sets and analyses of flow behavior in rod bundles with hexagonal spacer grids. In conclusion, the results are critical toward LMFR design and geometry optimization, crucial for the validation of computational fluid dynamics and reduced-order flow models.

42 ENGINEERING↗

Coulombic friction in metamaterials to dissipate mechanical energy

Product designs from a wide range of industries such as aerospace, automotive, biomedical, and others can benefit from new metamaterials for mechanical energy dissipation. In this study, we explore a novel new class of metamaterials with unit cells that absorb energy via sliding Coulombic friction. Remarkably, even materials such as metals and ceramics, which typically have no intrinsic reversible energy dissipation, can be architected to provide dissipation akin to elastomers. The concept is demonstrated at different scales (centimeter to micrometer), with different materials (metal and polymer), and in different operating environments (high and low temperatures), all showing substantial dissipative improvements over conventional non-contacting lattice unit cells. Further, as with other ‘programmable’ metamaterials, the degree of Coulombic absorption can be tailored for a given application. Additionally, an analytic expression is derived to allow rapid first-order optimization. This new class of Coulombic friction energy absorbers can apply broadly to many industrial sectors such as transportation (e.g. monolithic shock absorbers), biomedical (e.g. prosthetics), athletic equipment (e.g. skis, bicycles, etc.), defense (e.g. vibration tolerant structures), and energy (e.g. survivable electrical grid components).

36 MATERIALS SCIENCE↗

Toward the Instrumentation and Data Acquisition of a Tidal Turbine in Real Site Conditions

The National Renewable Energy Laboratory manufactured, instrumented, and deployed thermoplastic composite blades and a data acquisition system (NDAQ) on one of Verdant Power’s Gen5d 5 m diameter tidal turbines in New York’s East River. The thermoplastic blades had internal strain gages, and the NDAQ was a stand-alone system for monitoring and recording the strain and angular position of the blades. The turbine with thermoplastic blades operated and produced power successfully for 3 months, contributing energy to the New York City electric grid. The NDAQ hardware, instrumentation, and structure all survived the deployment and were still functional upon retrieval of the system, but no data were collected. Even though the data retrieval was not a success, data acquisition for deployed subsea marine renewable structures is a new undertaking, and it is critical to share lessons learned from national laboratory experiences. The successful deployment of thermoplastic composite blades marks a significant advancement toward improved materials for subsea components, as well as an advancement in recyclable composite materials. This article outlines the methodology and lessons learned for the instrumentation and data acquisition system.

16 TIDAL AND WAVE POWER↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

Convection–Kelvin Wave Coupling in a Global Convection-Permitting Model

A convectively coupled equatorial Kelvin wave (CCKW) was observed over the equatorial Indian Ocean in early November 2011 during the DYNAMO field campaign. This study examines the structure of the CCKW event using two simulations made using the MPAS model: one with 3-km grid spacing without convective parameterization and another with a 15-km grid and parameterized convection. Both simulations qualitatively capture the observed structure of the CCKW, including its vertical tilt and progression of cloud/precipitation structures. The two simulations, however, differ substantially in the amplitude of the CCKW-associated precipitation. While the 3-km run realistically captures the observed modulation of precipitation by the CCKW, the 15-km simulation severely underestimates its magnitude. To understand the difference between the two MPAS simulations regarding wave–convection coupling within the CCKW, the relationship of precipitation with convective inhibition, saturation fraction, and surface turbulent fluxes is investigated. Results show that the 15-km simulation underestimates the magnitude of the CCKW precipitation peak in association with its unrealistically linear relationship between moisture and precipitation. Precipitation, both in observations and the 3-km run, is predominantly controlled by saturation fraction and this relationship is exponential. In contrast, the parameterized convection in the 15-km run is overly sensitive to convective inhibition and not sensitive enough to environmental moisture. The implications of these results on CCKW theories are discussed.

54 ENVIRONMENTAL SCIENCES↗

Numerical and experimental investigation of the flame kernel growth in a methane/air mixture near the lean flammability limit

Lean combustion has the potential to improve the thermal efficiency of spark-ignition engines, but it faces the significant challenge of increased cycle-to-cycle variation due to low mixture reactivity and unstable flame dynamics. Computational fluid dynamics (CFD) employing predictive models can guide engine design and optimize operating strategies for lean combustion. However, ignition and combustion models have rarely been validated at fuel-lean conditions, and a fundamental understanding of the early flame kernel growth process is also lacking for a successful sub-model development. Here, the present study develops a numerical simulation framework used to investigate early flame kernel growth in methane/air mixtures. A nanosecond-pulsed discharge (NPD) approach is employed to effectively decouple the flame kernel growth from the electrical discharge due to their difference in timescales, and equivalence ratios near the experimentally measured lean flammability limit (LFL) are selected to focus on challenging mixture conditions. Three numerical investigations, such as the choice of turbulence modeling, grid size, and grid control strategies, are examined to match both LFL and flame kernel structure measured from experiments. It is demonstrated that a quasi-direct numerical simulation (QDNS) with a fixed grid embedding of 10 μm can predict the LFL as φ CFD =0.61 and match the displacement speed of the kernel’s boundary marked in schlieren images. To predict the LFL and flame kernel shape, a fine grid (Δ≤12.5 μm) is needed to capture the consumption of formaldehyde (CH 2 O) in kernel’s reaction branches attached to the anode, and adaptive mesh refinement is replaced with the fixed embedding due to loss of simulation accuracy. Also, it is found that a large-eddy simulation (LES) using the Dynamic Structure model is not suitable for the NPD-induced flame kernel simulation because artificial sub-grid turbulent kinetic energy induced by shock dynamics alters the flow velocity calculation, resulting in divergence of LES from QDNS. Lastly, the simulation well matches the experimental data for the flame kernel evolution in three mixture conditions (φ = 0.7, 0.61, 0.55), showing toroidal flame kernel expansion and flame kernel growth/extinction.

33 ADVANCED PROPULSION SYSTEMS↗

Economic Evaluation of Modernization Expenditures for Electric Utility Distribution Systems: A Guide for Utility Regulators

Cost-effectiveness evaluation of potential grid modernization solutions is integral to integrated distribution system planning (IDSP). This report synthesizes and updates prior cost-effectiveness approaches identified by the U.S. Department of Energy for grid modernization investments, incorporating multi-objective decision-making. The structure of the report follows the IDSP process, from identifying objectives and priorities to prioritizing grid solutions. The report details two methods for conducting initial cost-effectiveness screening of individual and interdependent grid components: (1) Lowest Reasonable Cost and (2) Benefit-Cost Analysis. Drawing on solutions that passed the initial cost-effectiveness screen, the utility prioritizes grid solutions based on policy objectives and priorities, regulatory compliance, operational efficiencies, and other factors to develop a portfolio of distribution solutions. The utility uses multi-objective decision-making to assess each proposed expenditure against each objective and respective metric. The utility applies a weighting factor, reflecting the priority ranking of the objective, to the total numerical “score” based on the contribution of the proposed solution to addressing each objective. Ultimately, the utility ranks each expenditure from highest to lowest priority using the final score for each solution as well as its cost. The report includes examples of emerging best practices for states and utilities and a cost-effectiveness process checklist.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗