Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs ) results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Second Solvent Lot Qualification Sample for the Salt Waste Processing Facility

An Extraction, Scrub, and Strip (ESS) test was performed on the qualification sample from the second lot of Caustic-Side Solvent Extraction (CSSX) solvent for the Salt Waste Processing Facility (SWPF). Testing used simulated salt solution to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 14.4, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Characterization of High Thermal Conductivity Pipes from Roll-to- Roll Processed Hybrid Copper-Polymer Strips for Waste Heat Recovery

Metal based heat exchangers targeting low temperature (<150°C) waste heat recovery (WHR) face high maintenance and material costs [1] that result in long payback periods (>1 year). Low-cost polymer pipes suffer from poor thermal conductivity (~0.2 W/m.K), and thus a low overall heat transfer coefficient. Previous reports demonstrated thermal conductivity enhancement in polymers through systematic molecular alignment [2, 3, 4], or by metal micro-particle inclusions [5]. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [1, 3], and thermomechanical considerations [6, 7]. In this work, we propose hybrid metal-polymer strips that are strategically designed to enhance thermal conductivity by cladding copper around polymer strips. The polymer strips with copper-clad edges are wound helically to form the pipes for a heat exchanger. Through numerical simulations, we optimize the copper-polymer strip layouts to achieve high wall thermal conductivity (k > 1 W/m.K) and also have low volume fraction of copper (<70%) for the composite pipes. In copper-polymer composite heat exchangers, the bottlenecks for heat transfer are the thermal interfacial resistances of copper-copper and copper-polymer joints. We experimentally measured interfacial resistances to be ~1x10 -5 K.m 2 /W and ~4x10 -5 K.m 2 /W for copper-copper and copper-polymer joints, respectively. Using the measured interfacial resistances, we further optimized the design of the hybrid pipes to find high thermal conductivity (> 1 W/m.K) designs. We predict up to ~20 % enhancement in overall heat transfer relative to an all polymer (k = 0.2 W/m.K) heat exchanger system. Using a cohesive zone modelling (CZM) for predicting delamination at the weld joints, we find that our hybrid pipes can have operating internal pressures > 200 psi. The optimized designs of hybrid metal-polymer pipes provide a scalable and cost- effective means for harvesting waste heat from low temperature sources. Thekdi, A., and Nimbalkar, S. Oak Ridge National Lab (2014). Shen, Sheng, et al. Nature nanotechnology 5.4 (2010). Xu, Yanfei, et al. Science advances 4.3 (2018). Smith et al. ACS nano, 9(2), (2015). Sofian, N.M., et al., Journal of Thermoplastic Composite Materials (2001). Aymonier et al. Chemistry of Materials, 15(25), (2003). Tavman, I.H., Journal of Applied Polymer Science, 62(12), (1996).

C Rajagopal, Manjunath↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D (Cs) ), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) measured 13.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Sample Tank 202

An Extraction, Scrub, and Strip (ESS) test was performed on a sample from Tank-202. The purpose of testing this sample is to determine if the solvent is displaying the correct extraction and stripping behavior with cesium. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 14.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Extraction-Scrub-Strip (ESS) Tests With Solvent Using IBC BOBCalix

Two Extraction, Scrub, and Strip (ESS) tests were performed on two BOBCalix solvent samples prepared using BOBCalix from IBC Advanced Technologies (“IBC”). The purpose of testing this sample is to confirm if the newly sourced BOBCalix displays the correct extraction and stripping behavior with cesium. The first batch of BOBCalix solvent was prepared using IBC lot#220310KC-1. The second batch was prepared using IBC lot#220615KC-3A. The ESS tests showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) values for the tests were 12.9 and 13.6. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios (0.0588/0.0342/0.0258 and 0.0575/0.0335/0.0262) fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting the Presence of Companions for Stripped-envelope Supernovae: The Case of the Broad-lined Type Ic SN 2002ap

Many young, massive stars are found in close binaries. Using population synthesis simulations we predict the likelihood of a companion star being present when these massive stars end their lives as core-collapse supernovae (SNe). We focus on stripped-envelope SNe, whose progenitors have lost their outer hydrogen and possibly helium layers before explosion. We use these results to interpret new Hubble Space Telescope observations of the site of the broad-lined Type Ic SN 2002ap, 14 years post-explosion. For a subsolar metallicity consistent with SN 2002ap, we expect a main-sequence (MS) companion present in about two thirds of all stripped-envelope SNe and a compact companion (likely a stripped helium star or a white dwarf/neutron star/black hole) in about 5% of cases. About a quarter of progenitors are single at explosion (originating from initially single stars, mergers, or disrupted systems). All of the latter scenarios require a massive progenitor, inconsistent with earlier studies of SN 2002ap. Our new, deeper upper limits exclude the presence of an MS companion star >8–10 M{sub ⊙}, ruling out about 40% of all stripped-envelope SN channels. The most likely scenario for SN 2002ap includes nonconservative binary interaction of a primary star initially ≲23 M{sub ⊙}. Although unlikely (<1% of the scenarios), we also discuss the possibility of an exotic reverse merger channel for broad-lined Type Ic events. Finally, we explore how our results depend on the metallicity and the model assumptions and discuss how additional searches for companions can constrain the physics that govern the evolution of SN progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary-stripped Stars as Core-collapse Supernovae Progenitors

Most massive stars experience binary interactions in their lifetimes that can alter both the surface and core structure of the stripped star with significant effects on their ultimate fate as core-collapse supernovae. However, core-collapse supernovae simulations to date have focused almost exclusively on the evolution of single stars. We present a systematic simulation study of single and binary-stripped stars with the same initial mass as candidates for core-collapse supernovae (11–21 M⊙). Generally, we find that binary-stripped stars core tend to have a smaller compactness parameter, with a more prominent, deeper silicon/oxygen interface, and explode preferentially to the corresponding single stars of the same initial mass. Such a dichotomy of behavior between these two modes of evolution would have important implications for supernovae statistics, including the final neutron star masses, explosion energies, and nucleosynthetic yields. Binary-stripped remnants are also well poised to populate the possible mass gap between the heaviest neutron stars and the lightest black holes. Our work presents an improvement along two fronts, as we self-consistently account for the pre-collapse stellar evolution and the subsequent explosion outcome. Even so, our results emphasize the need for more detailed stellar evolutionary models to capture the sensitive nature of explosion outcome.

79 ASTRONOMY AND ASTROPHYSICS↗

Biomass yield potential, feedstock quality, and nutrient removal of perennial buffer strips under continuous zero fertilizer application

Perennial-based buffer strips have been promoted as having the potential for improving ecosystem services from riparian areas while producing biomass as livestock feed or as a bioenergy feedstock. Both biomass production and nutrient removal of buffer strips are substantially influenced by the vegetation types for the multipurpose perennial buffers. In this 2016–2019 study in western Illinois, two perennial cropping systems, including forage crops composed of cool-season grass mixtures (forage system) and bioenergy crops made up of warm-season grass mixtures (bioenergy system), were used to establish buffer strips for assessing biomass production, feedstock quality, nutrient removal, and buffer longevity. Treatments for this study reflecting agronomic practices included (1) two harvests occurring in summer (at anthesis) and fall (after complete senescence) and (2) one harvest in fall for the forage system (two-cut vs. one-cut forage) and (3) one fall harvest for the bioenergy system (one-cut bioenergy). Successively harvesting without any fertilizer input resulted in a yield decline in forage biomass over 3 years by approximately 30 % (6.3 to 4.4 Mg DM ha –1 (dry matter) with a rate of 1.0 Mg ha –1 yr –1 ) in the two-cut forage and by 35 % (4.9 to 3.2 Mg DM ha –1 with a rate of 0.9 Mg ha –1 yr –1 ) in the one-cut forage systems. The feed quality also decreased over the years by showing declined rates of 12.9 (crucial protein), 0.9 (calcium), 0.7 (copper), and 1.3 g kg –1 DM yr –1 (zinc). Empirical models predicted enteric CH 4 emissions from cattle ranged from 225.7 to 242.6 g per cow per day based on the feed nutritive values. In contrast, bioenergy biomass yield increased by 27 % from 4.9 to 6.7 Mg DM ha –1 with a consistent quality (cellulose of ~ 397.9 g kg –1 ; hemicellulose of ~ 299.4 g kg –1 ), corresponding to the increased total theoretical ethanol yield from 1.8 × 10 3 to 2.4 × 10 3 L ha –1 (~ 33 % increase). Annual nutrient removals of N, P, K, Ca, and Mg were significantly higher in the forage systems (e.g., two-cut: 52.6–106.9 kg N ha –1 ; one-cut: 44.5–84.1 kg N ha –1 ) than those in the bioenergy system (e.g., 25.9–34.4 kg N ha –1 ); however, the removal rate declined rapidly over 3 years (e.g., ~ 49 % reduction) as the annual biomass yield declined in the forage systems. This on-farm field study demonstrated the potential of the perennial crop used as buffer strip options for biomass production and buffer sustainability at the edge of the field.

09 BIOMASS FUELS↗

Fixture for multiple-FCC chemical stripping and plating

For chemical stripping, lead tape applied near ends to be stripped protects insulation. Taped ends are submerged half way in stripping solution. For electroplating, both ends of FCC are stripped - top ends for electric contact, others for submersion in electroplating solution.

Angele, W.↗

Ecological effects of strip mining in Ohio

The author has identified the following significant results. One result significant as a practical application and for cost benefit analysis is the relative ease with which ERTS-1 will monitor new and unclaimed stripping activities in Southeastern Ohio and in all of Appalachia. Band 5 resolution appears to be better than the often reported 80 meters. The strip mines stand out well enough to be easily identified without other graphic aids. Standing water within the strip mined area stands out in either bands 6 or 7. Areas of several acres are visible. Significant increases in surface extent of water of stripped areas should be detectable on a comparative basis. The degree of reclamation is observable in the imagery in rather gross percentage steps and for areas larger than the bare earth sizes in the table. The gradation in tones in the different bands indicates that probability density imagery using the four bands in CCT data (and statistical processing) is likely to separate degrees of vegetative reclamation.

Chase, P. E.↗

Fracture of composite plates containing periodic buffer strips

Fracture of a composite plate which consists of perfectly bonded parallel load carrying laminates and buffer strips is considered. Fatigue cracks appear and spread in main laminates or in buffer strips or in both perpendicular to the interfaces. The external load is applied to the plate parallel to the strips and away from the crack region. The problem is solved for fully imbedded cracks and for broken laminates or strips. Corresponding stress intensity factors are calculated.

Erdogan, F.↗

The Crack-contact and the Free End Problem for a Strip Under Residual Stress

The plane problem for an infinite strip with two edge cracks under a given state of residual stress is considered. The residual stress is compressive near and at the surfaces and tensile in the interior of the strip. If the crack is deep enough to penetrate into the tensile zone, then the problem is one of crack-contact problem in which the depth of the contact area is an unknown which depends on the crack depth and the residual stress profile. The problem has applications to the static fatigue of glass plates and is solved for three typical residual stress profiles. In the limiting case of the crack crossing the entire plate thickness, the problem becomes a stress-free end problem for a semi-infinite strip under a given residual stress state away from the end. This is a typical stress diffusion problem in which decay behavior of the residual stress near and the nature of the normal displacement at the end of the semi-infinite strip are of special interest. For two typical residual stress states the solution is obtained, and some numerical results are given.

Bakioglu, M.↗

Fracture of plates which consist of periodic dissimilar strips

In this paper the fracture problem of a composite plate which consists of perfectly bonded parallel load carrying laminates and buffer strips is considered. It is assumed that the fatigue cracks may appear and spread in main laminates or in buffer strips or in both perpendicular to the interfaces. The external load is applied to the plate parallel to the strips and away from the crack region. The problem is solved for fully imbedded cracks and for broken laminates or strips and the corresponding stress intensity factors are calculated.

Erdogan, F.↗

The crack-contact and the free-end problem for a strip under residual stress

The plane problem for an infinite strip with two edge cracks under a given state of residual stress is considered. The residual stress is compressive near and at the surfaces and tensile in the interior of the strip. If the crack is deep enough to penetrate into the tensile zone, then the problem is one of crack-contact where the depth of the contact area is an unknown which depends on the crack depth and the residual stress profile. The problem has applications to the static fatigue of glass plates and is solved for three typical residual-stress profiles. In the limiting case of the crack's crossing the entire plate thickness, the problem becomes a stressfree end problem for a semiinfinite strip under a given residual-stress state away from the end. This is a typical stress diffusion problem in which decay behavior of the residual stress near and the nature of the normal displacement at the end of the semiinfinite strip are of special interest. For two typical residual-stress states the solution is obtained, and some numerical results are given.

Bakioglu, M.↗

The problem of an inclined crack in an orthotropic strip

The elastostatic problem for an infinite orthotropic strip containing crack was considered. It was assumed that the orthogonal axes of material orthotropy may have an arbitrary angular orientation with respect to the orthogonal axes of geometric symmetry of the uncracked strip. The crack was located along an axis of orthotropy, hence, at an arbitrary angle with respect to the sides of the strip. The general problem was formulated in terms of a system of singular integral equations for arbitrary crack surface tractions. As examples Modes 1 and 2 stress intensity factors were calculated for the strip having an internal or an edge crack with various lengths and angular orientations.

Delale, F.↗