Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stopping Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate

Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.

Environmental Molecular Sciences Laboratory↗

SU-C-201-07: Towards Clinical Cherenkov Emission Dosimetry: Stopping Power-To-Cherenkov Power Ratios and Beam Quality Specification of Clinical Electron Beams

Purpose: We propose a Cherenkov emission (CE)-based reference dosimetry method, which in contrast to ionization chamber-based dosimetry, employs spectrum-averaged electron restricted mass collision stopping power-to-Cherenkov power ratios (SCRs), and we examine Monte Carlo-calculated SCRs and beam quality specification of clinical electron beams. Methods: The EGSnrc user code SPRRZnrc was modified to compute SCRs instead of stopping-power ratios (single medium: water; cut-off: CE threshold (observing Spencer-Attix conditions); CE power: Frank-Tamm). SCRs are calculated with BEAMnrc for realistic electron beams with nominal energies of 6–22 MeV from three Varian accelerators (TrueBeam Clinac 21EX, Clinac 2100C/D) and for mono-energetic beams of energies equal to the mean electron energy at the water surface. Sources of deviation between clinical and mono-energetic SCRs are analyzed quantitatively. A universal fit for the beam-quality index R{sub 50} in terms of the depth of 50% CE C{sub 50} is carried out. Results: SCRs at reference depth are overestimated by mono-energetic values by up to 0.2% for a 6-MeV beam and underestimated by up to 2.3% for a 22-MeV beam. The variation is mainly due to the clinical beam spectrum and photon contamination. Beam angular spread has a small effect across all depths and energies. The influence of the electron spectrum becomes increasingly significant at large depths, while at shallow depths and high beam energies photon contamination is predominant (up to 2.0%). The universal data fit reveals a strong linear correlation between R{sub 50} and C{sub 50} (ρ > 0.99999). Conclusion: CE is inherent to radiotherapy beams and can be detected outside the beam with available optical technologies, which makes it an ideal candidate for out-of-beam high-resolution 3D dosimetry. Successful clinical implementation of CE dosimetry hinges on the development of robust protocols for converting measured CE to radiation dose. Our findings constitute a key step towards clinical CE dosimetry.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d{sub max}), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R{sub 50} in terms of C{sub 50} (50% CE depth) revealed a strong linear dependence (R{sup 2} > 0.9999). The SCR was fit with a Burns-type equation (R{sup 2} = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Energy Loss of Li and C Ions with MeV Energies in the Polycarbonate and Polypropylene

Stopping power and straggling of Li ions and C ions at mean energy 3.8-5.4 MeV and 5.6-6.9 MeV, respectively, in polycarbonate (PC) and at mean energy 3.7-5.2 MeV and 6.8-8.0 MeV in polypropylene (PP) foils have been measured using ion beams from a Tandetron 4130 MC accelerator. The ions scattered from a thin, primary gold target were registered by a surface barrier detector partially covered with a thin foil of the investigated polymer. The stopping power was determined from the energy difference between the signals from the ions directly backscattered from the Au layer and the ions backscattered and slowed down in the foil. The foil thickness was determined by the weighing procedure. The experimentally determined stopping powers were compared with those calculated with the SRIM 2010 code. The measured stopping powers are in good agreement for Li and C in PC, the differences being within 0.1-1.6% for Li and 0.2-2.1% for C. For Li and C in PP, the stopping powers are lower than the calculated ones, the differences being within 0.5-2.8% for Li and 3.6-6.1% for C. The energy straggling was determined from the width of the RBS signals. The experimentally determined energy straggling was found to fluctuate around the values calculated according to Bohr theory.

36 MATERIALS SCIENCE↗

Damage Profiles and Ion Distribution in Pt-irradiated SiC

Single crystalline 6H-SiC samples were irradiated at 150 K with 2 MeV Pt ions. The local volume swelling was determined by electron energy loss spectroscopy (EELS), and a nearly sigmoidal dependence on irradiation dose is observed. The disorder profiles and ion distribution were determined by Rutherford backscattering spectrometry (RBS), transmission electron microscopy, and secondary ion mass spectrometry. Since the volume swelling reaches 12% over the damage region at high ion fluence, the effect of lattice expansion is considered and corrected for in the analysis of RBS spectra to obtain depth profiles. Projectile and damage profiles are estimated by SRIM (Stopping and Range of Ions in Matter).When compared with the measured profiles, the SRIM code predictions of ion distribution and the damage profiles are underestimated due to significant overestimation of the electronic stopping power for the slow heavy Pt ions. By utilizing the reciprocity method, which is based on the invariance of the inelastic energy loss in ion-solid collisions against interchange of projectile and target atom, a much lower electronic stopping power is deduced. A simple approach, based on reducing the density of SiC target in SRIM simulation, is proposed to compensate the overestimated SRIM electronic stopping power values, which results in improved agreement between predicted and measured damage profiles and ion ranges.

Environmental Molecular Sciences Laboratory↗

Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors

In a previous study [Med. Phys. 35, 1747-1755 (2008)], the authors proposed two direct methods of calculating the replacement correction factors (P{sub repl} or p{sub cav}p{sub dis}) for ion chambers by Monte Carlo calculation. By ''direct'' we meant the stopping-power ratio evaluation is not necessary. The two methods were named as the high-density air (HDA) and low-density water (LDW) methods. Although the accuracy of these methods was briefly discussed, it turns out that the assumption made regarding the dose in an HDA slab as a function of slab thickness is not correct. This issue is reinvestigated in the current study, and the accuracy of the LDW method applied to ion chambers in a {sup 60}Co photon beam is also studied. It is found that the two direct methods are in fact not completely independent of the stopping-power ratio of the two materials involved. There is an implicit dependence of the calculated P{sub repl} values upon the stopping-power ratio evaluation through the choice of an appropriate energy cutoff {Delta}, which characterizes a cavity size in the Spencer-Attix cavity theory. Since the {Delta} value is not accurately defined in the theory, this dependence on the stopping-power ratio results in a systematic uncertainty on the calculated P{sub repl} values. For phantom materials of similar effective atomic number to air, such as water and graphite, this systematic uncertainty is at most 0.2% for most commonly used chambers for either electron or photon beams. This uncertainty level is good enough for current ion chamber dosimetry, and the merits of the two direct methods of calculating P{sub repl} values are maintained, i.e., there is no need to do a separate stopping-power ratio calculation. For high-Z materials, the inherent uncertainty would make it practically impossible to calculate reliable P{sub repl} values using the two direct methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-BRC-04: Development of Proton Tissue Equivalent Materials for Calibration and Dosimetry Studies

Purpose: To develop new proton tissue equivalent materials (PTEM), urethane and fiberglass based, for proton therapy calibration and dosimetry studies. Existing tissue equivalent plastics are applicable only for x-rays because they focus on matching mass attenuation coefficients. This study aims to create new plastics that match mass stopping powers for proton therapy applications instead. Methods: New PTEMs were constructed using urethane and fiberglass resin materials for soft, fat, bone, and lung tissue. The stoichiometric analysis method was first used to determine the elemental composition of each unknown constituent. New initial formulae were then developed for each of the 4 PTEMs using the new elemental compositions and various additives. Samples of each plastic were then created and exposed to a well defined proton beam at the UF Health Proton Therapy Institute (UFHPTI) to validate its mass stopping power. Results: The stoichiometric analysis method revealed the elemental composition of the 3 components used in creating the PTEMs. These urethane and fiberglass based resins were combined with additives such as calcium carbonate, aluminum hydroxide, and phenolic micro spheres to achieve the desired mass stopping powers and densities. Validation at the UFHPTI revealed adjustments had to be made to the formulae, but the plastics eventually had the desired properties after a few iterations. The mass stopping power, density, and Hounsfield Unit of each of the 4 PTEMs were within acceptable tolerances. Conclusion: Four proton tissue equivalent plastics were developed: soft, fat, bone, and lung tissue. These plastics match each of the corresponding tissue’s mass stopping power, density, and Hounsfield Unit, meaning they are truly tissue equivalent for proton therapy applications. They can now be used to calibrate proton therapy treatment planning systems, improve range uncertainties, validate proton therapy Monte Carlo simulations, and assess in-field and out-of-field organ doses.

60 APPLIED LIFE SCIENCES↗

MO-A-201-00: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

MO-A-201-01: A Cliff’s Notes Version of Proton Therapy

Proton therapy is a rapidly growing modality in the fight against cancer. From a high-level perspective the process of proton therapy is identical to x-ray based external beam radiotherapy. However, this course is meant to illustrate for x-ray physicists the many differences between x-ray and proton based practices. Unlike in x-ray therapy, proton dose calculations use CT Hounsfield Units (HU) to determine proton stopping power and calculate the range of a beam in a patient. Errors in stopping power dominate the dosimetric uncertainty in the beam direction, while variations in patient position determine uncertainties orthogonal to the beam path. Mismatches between geometric and range errors lead to asymmetric uncertainties, and so while geometric uncertainties in x-ray therapy are mitigated through the use of a Planning Target Volume (PTV), this approach is not suitable for proton therapy. Robust treatment planning and evaluation are critical in proton therapy, and will be discussed in this course. Predicting the biological effect of a proton dose distribution within a patient is also a complex undertaking. The proton therapy community has generally regarded the Radiobiological Effectiveness (RBE) of a proton beam to be 1.1 everywhere in the patient, but there are increasing data to suggest that the RBE probably climbs higher than 1.1 near the end of a proton beam when the energy deposition density increases. This lecture will discuss the evidence for variable RBE in proton therapy and describe how this is incorporated into current proton treatment planning strategies. Finally, there are unique challenges presented by the delivery process of proton therapy. Many modern systems use a spot scanning technique which has several advantages over earlier scattered beam designs. However, the time dependence of the dose deposition leads to greater concern with organ motion than with scattered protons or x-rays. Image guidance techniques in proton therapy may also differ from standard x-ray approaches, due to equipment design or the desire to maximize efficiency within a high-cost proton therapy treatment room. Differences between x-ray and proton therapy delivery will be described. Learning Objectives: Understand how CT HU are calibrated to provide proton stopping power, and the sources of uncertainty in this process. Understand why a PTV is not suitable for proton therapy, and how robust treatment planning and evaluation are used to mitigate uncertainties. Understand the source and implications of variable RBE in proton therapy Learn about proton specific challenges and approaches in beam delivery and image guidance Jon Kruse has a research grant from Varian Medical Systems related to proton therapy treatment plannning.; J. Kruse, Jon Kruse has a research grant with Varian Medical Systems related to proton therapy planning.

60 APPLIED LIFE SCIENCES↗

Coulomb Logarithm, Version 1.0

Clog is a library of charged particle stopping powers and related Coulomb logarithm processes in a plasma. The stopping power is a particularly useful quantity for plasma physics, as it measures the energy loss of per unit length of charged particle as it traverses a plasma. Clog's primary stopping power is the BPS (Brown-Preston-Singleton) theory.

Singleton, Robert↗

Coulomb Logarithm, Version 1.0

Clog is a library of charged particle stopping powers and related Coulomb logarithm processes in a plasma. The stopping power is a particularly useful quantity for plasma physics, as it measures the energy loss of per unit length of charged particle as it traverses a plasma. Clog's primary stopping power is the BPS (Brown-Preston-Singleton) theory.

Singleton, Robert↗

Interaction of fast charged projectiles with two-dimensional electron gas: Interaction and collisional-damping effects

The results of a theoretical investigation on the stopping power of ions moving in a two-dimensional degenerate electron gas are presented. The stopping power for an ion is calculated employing linear-response theory using the dielectric function approach. The collisions, which lead to a damping of plasmons and quasiparticles in the electron gas, is taken into account through a relaxation-time approximation in the linear-response function. The stopping power for an ion is calculated in both the low- and high-velocity limits. In order to highlight the effects of damping, we present a comparison of our analytical and numerical results, in the case of pointlike ions, obtained for a nonzero damping with those for a vanishing damping. It is shown that the equipartition sum rule first formulated by Lindhard and Winther for three-dimensional degenerate electron gas does not necessarily hold in two dimensions. We have generalized this rule introducing an effective dielectric function. In addition, some results for two-dimensional interacting electron gas have been obtained. In this case, the exchange-correlation interactions of electrons are considered via local-field corrected dielectric function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transport of low- and medium-energy electron and ion beams in seawater and its vapors

A general theory of stopping power for electrons and ions in a target medium (gas, liquid, or thin solid foil) containing neutral as well as positive and negative ions is developed. The approach is quite accurate in the low- and medium-energy range (less than 1 MeV), where the Bethe stopping-power cross section is inaccurate. The energy transfer during individual collisions is treated by the binary-encounter approximation. The theory is applied to determine the stopping power of seawater, whose major components are H2O molecules and Na(+) and Cl(-) ions. The stopping-power cross sections for low- and medium-energy protons in water show excellent agreement with existing measurements.

Erwin, Daniel A.↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗