Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stability Margin”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

159 records · Page 9

Frictional Behavior Downdip Along the Subduction Megathrust: Insights From Laboratory Experiments on Exhumed Samples at In Situ Conditions

Subduction megathrusts exhibit a spectrum of slip modes, including catastrophic earthquakes. Although the mechanical and frictional properties of materials sampled from subduction zones have been studied extensively, few datasets have been collected for compositions and at pressure and temperature conditions representative of those in situ. The Nankai subduction zone in southwest Japan is a well-studied margin, and abundant data provide an opportunity to advance our understanding of fault and earthquake physics. Here, we use samples exhumed in the Shimanto and Sanbagawa Belts on Shikoku Island of southwest Japan that represent analogs for materials along the present-day megathrust at depths of ~5–>25 km, and we shear these at their peak in situ pressure-temperature (P-T) conditions. Effective normal stresses range from 28 to 192 MPa, and temperatures from 105°C to 470°C. We used pore fluid pressures of 45–240 MPa, corresponding to fluid overpressure ratios λ of 0.65 and 0.90. Slip velocities of 0.1–100 μm/s were used, in order to focus on the nucleation of instability and earthquakes. We found predominantly velocity-strengthening (inherently stable) behavior under all conditions for λ = 0.65. For λ = 0.90, velocity-weakening behavior was observed at 350°C, with velocity-strengthening behavior at lower and higher temperatures. The rate/state frictional stability parameter (a-b) increases with slip velocity at temperatures up to ~200°C and remains constant or decreases with slip velocity at higher temperatures. Altogether, our results demonstrate the potentially important roles of both temperature and slip velocity in controlling the distribution of stress and frictional rheology along subduction thrusts.

58 GEOSCIENCES↗

Rapid retreat of the southwestern Laurentide Ice Sheet during the Bølling-Allerød interval

The timing of Laurentide Ice Sheet deglaciation along its southwestern margin controlled the evolution of large glacial lakes and has implications for human migration into the Americas. Accurate reconstruction of the ice sheet’s retreat also constrains glacial isostatic adjustment models and is important for understanding ice-sheet sensitivity to climate forcing. Despite its significance, retreat of the southwestern Laurentide Ice Sheet (SWLIS) is poorly constrained by minimum-limiting 14 C data. We present 26 new cosmogenic 10 Be exposure ages spanning the western Interior Plains, Canada. Using a Bayesian framework, we combine these data with geomorphic mapping, 10 Be, and high-quality minimum-limiting 14 C ages to provide an updated chronology. This dataset presents an internally consistent retreat record and indicates that the initial detachment of the SWLIS from its convergence with the Cordilleran Ice Sheet began by ca. 15.0 ka, concurrent with or slightly prior to the onset of the Bølling-Allerød interval (14.7–12.9 ka) and retreated >1200 km to its Younger Dryas (YD) position in ~2500 yr. Ice-sheet stabilization at the Cree Lake Moraine facilitated a meltwater drainage route to the Arctic from glacial Lake Agassiz within the YD, but not necessarily at the beginning. Our record of deglaciation and new YD constraints demonstrate deglaciation of the Interior Plains was ~60% faster than suggested by minimum 14 C constraints alone. In conclusion, numerical modeling of this rapid retreat estimates a loss of ~3.7 m of sea-level equivalent from the SWLIS during the Bølling-Allerød interval.

58 GEOSCIENCES↗

A time-varying vulnerability index for COVID-19 in New Mexico, USA using generalized propensity scores

The coronavirus disease (COVID-19) pandemic has highlighted systemic inequities in the United States and resulted in a larger burden of negative social outcomes for marginalized communities. New Mexico, a state in the southwestern US, has a unique population with a large racial minority population and a high rate of poverty that may make communities more vulnerable to negative social outcomes from COVID-19. To identify which communities may be at the highest relative risk, we created a county-level vulnerability index. After the first COVID-19 case was reported in New Mexico on March 11, 2020, we fit a generalized propensity score model that incorporates sociodemographic factors to predict county-level viral exposure and thus, the generic risk to negative social outcomes such as unemployment or mental health impacts. We used four static sociodemographic covariates important for the state of New Mexico—population, poverty, household size, and minority population—and weekly cumulative case counts to iteratively run our model each week and normalize the exposure score to create a time-varying vulnerability index. We found the relative vulnerability between counties varied in the first eight weeks from the initial COVID-19 case before stabilizing. This framework for creating a location-specific vulnerability index in response to an ongoing disaster may be used as a quick, deployable metric to inform health policy decisions such as allocating state resources to the county level.

59 BASIC BIOLOGICAL SCIENCES↗

The Importance of Modeling Carbon Dioxide Transportation and Geologic Storage in Energy System Planning Tools

Energy system planning tools suggest that the cost and feasibility of climate-stabilizing energy transitions are sensitive to the cost of CO 2 capture and storage processes (CCS), but the representation of CO 2 transportation and geologic storage in these tools is often simple or non-existent. We develop the capability of producing dynamic-reservoir-simulation-based geologic CO 2 storage supply curves with the Sequestration of CO 2 Tool (SCO 2 T) and use it with the ReEDS electric sector planning model to investigate the effects of CO 2 transportation and geologic storage representation on energy system planning tool results. We use a locational case study of the Electric Reliability Council of Texas (ERCOT) region. Our results suggest that the cost of geologic CO 2 storage may be as low as $3/tCO 2 and that site-level assumptions may affect this cost by several dollars per tonne. At the grid level, the cost of geologic CO 2 storage has generally smaller effects compared to other assumptions (e.g., natural gas price), but small variations in this cost can change results (e.g., capacity deployment decisions) when policy renders CCS marginally competitive. The cost of CO 2 transportation generally affects the location of geologic CO 2 storage investment more than the quantity of CO 2 captured or the location of electricity generation investment. We conclude with a few recommendations for future energy system researchers when modeling CCS. For example, assuming a cost for geologic CO 2 storage (e.g., $5/tCO 2 ) may be less consequential compared to assuming free storage by excluding it from the model.

20 FOSSIL-FUELED POWER PLANTS↗

Traps and transport resistance are the next frontiers for stable non-fullerene acceptor solar cells

Stability is one of the most important challenges facing material research for organic solar cells (OSC) on their path to further commercialization. In the high-performance material system PM6:Y6 studied here, we investigate degradation mechanisms of inverted photovoltaic devices. We have identified two distinct degradation pathways: one requires the presence of both illumination and oxygen and features a short-circuit current reduction, the other one is induced thermally and marked by severe losses of open-circuit voltage and fill factor. We focus our investigation on the thermally accelerated degradation. Our findings show that bulk material properties and interfaces remain remarkably stable, however, aging-induced defect state formation in the active layer remains the primary cause of thermal degradation. The increased trap density leads to higher non-radiative recombination, which limits the open-circuit voltage and lowers the charge carrier mobility in the photoactive layer. Furthermore, we find the trap-induced transport resistance to be the major reason for the drop in fill factor. Our results suggest that device lifetimes could be significantly increased by marginally suppressing trap formation, leading to a bright future for OSC.

14 SOLAR ENERGY↗

ESR Dipole Power Supply Current Ripple and Noise Specifications

This note presents key findings for the ESR main magnet dipole power supplies (PS), where we find the current ripple specification to be close to or beyond the state-of-the-art. These specifications originate from beam-beam considerations, with the requirement to limit the ripple-induced hadron emittance growth to below 10%/hour. Beam dynamics that drive this PS ripple specification arise from the beam motions at the Interaction Point (IP). The frequency of the motions can be separated into "low", compared to the betatron frequency, and "high", i.e. around the betatron frequency and harmonics. In terms of the driving frequency, "low" implies ƒ<<ƒ 0 v x,y and "fast" means ƒ≈{ƒ 0 v x,y , ƒ 0 (1- v x,y , etc.}, where ƒ 0 =1/ T 0 =78.2 kHz is the revolution frequency, and v x,y are the fractional parts of the betatron tunes. Frequencies higher than ƒ 0 /2 will be folded back due to the particles sampling the field once per turn. To provide flexibility for future lattice adjustments and working point variations, we do not consider the tunes as fixed. Instead, we assume a certain margin and allow them to potentially fall within the range of 0.1< v x,y <0.5. In other words, the high-frequency region spans approximately from 8kHz to 40 kHz. Consequently,, we definte the dipole PS ripple in two distinct frequency ranges: the low-frequency range of [1-8000] Hz and the high-frequency range of [8-40] kHz. For the physics effects we analyzed in this note, there is no distinction between the ripple (which can be approximately reproduced in the frequency domain) and the random noise if both have some power within the frequency bandwidth of interest. Therefore, while we will use the term "ripple" for short, it should always be understood that we are referring to "ripple plus noise." Except for the lower end of the low-frequency range, the impact of the rippling PS current on the beam will be considerably reduced due to the eddy currents induced in the walls of the vacuum chamber. We will account for this effect in the PS ripple specifications to follow. The remaining sections of this note are structure as follows: Section II outlines the beam-beam physics requirements for the positional stability of the beam at the IP. Section III describes the anticipated shielding effect of the eddy currents induced in the vacuum chamber. Section IV derives the ripple requirement for the low-frequency range by propagating the closed orbit ripple resulting from the rippling dipoles to the IP (relevant lattice simulation results are summarized in the Appendix). In Section V, we present the analytical criterion for the ripple in the high-frequency range by considering resonant oscillations of the electron beam around a stable closed orbit near the betatron frequency. Finally, Section VI provides a summary of our findings and discusses related work.

43 PARTICLE ACCELERATORS↗

MARVEL Reactor Fuel Performance Report (Rev.2)

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Storage Conditions on the Quality and Viability of Switchgrass as a Bioenergy Crop

With growing energy demands and climate concerns, advancements in bioenergy have become imperative. Biofuels promote energy independence, reduce fossil fuel reliance, and cut greenhouse gas emissions. Switchgrass (Panicum virgatumis) is an ideal bioenergy crop due to its ability to thrive on marginal lands unsuitable for food crops and its drought tolerance, rendering it a low-maintenance, high-yield option. In the bioenergy industry, energy crops are typically stored to facilitate supply chain management and ensure a continuous supply despite seasonal availability. However, the effective utilization of bioenergy crops is typically contingent upon addressing the challenges associated with biomass storage. These challenges include high moisture content that promotes biological degradation of the biomass leading to increased risk of pathogenic microbes, and chemical degradation that increases the ratio of inconvertible, inorganic materials. These issues lead to a reduction of feedstock value, diminishing the biomass-to-biofuel conversion efficacy, making switchgrass and other bioenergy crops less effective as fuel sources. This project aims to improve the storage of purpose-grown energy crops. Aerobic storage trials were conducted under varying moisture contents to stimulate real-world environmental exposure. Switchgrass samples were rewetted to 30% or 35% and stored in a bioreactor for approximately one month, or until cellular respiration ceased. Degradation indicators, such as dry matter loss, temperature changes, and cellular respiration, were measured throughout this process. Samples for compositional analysis, 16S, and ITS were taken at three different time points: before, during, and after storage, to monitor changes in biomass, microbial communities, and metabolites over time. Preliminary data indicate that dry matter loss is proportional to cellular respiration, with higher moisture content (35%) leading to higher temperatures and elevated dry matter loss. Compositional analysis and microbial community analysis are in progress. This research will provide a comprehensive understanding of storage, helping to identify stability factors in energy crops and improve best management practices for biomass producers.

09 - BIOMASS FUELS↗

Bamboo Bio-composite Truck/Trailer Decking

Bamboo is one of the fastest growing plants in the world. Massively productive, bamboo will maintain that productivity with limited inputs and minimal management resulting in predictable volume and operating margins and with low overhead. The goal of this project was to develop a bamboo bio-composite trailer decking product that replaces apitong, is lighter weight, stronger and luminescent. The collaboration partners, Fontaine, Resource Fiber and IACMI, worked closely to develop the bamboo bio-composite decking to Fontaine Trailer’s (end-user) specifications. The various technological objectives were (a) To conduct a comprehensive Design of Experiments study for bamboo composites to understand the structure-property relationships for different resin composites and bamboo forms (strips, woven, bulk etc); (b) To establish the nail pull out characteristics of trailer deck geometry bamboo composite form. The nail pull out is a critical test in trailer decks; (c) To design, process and prototype select number of trailer decking planks for Fontaine evaluation; and (d) To conduct life cycle analysis to conduct energy calculations from the various conversion steps of the bamboo from crop to product. The project meets DOE/IACMI metrics of reduced embodied energy, lightweighting and lowering the cost of the end product. It also offers a green solution to a value-added application, i.e. trailer decking. The development goals and benefits of bamboo composite decking included: A. Decreased weight when compared to Apitong and Gen 1, thereby reducing operating costs and petroleum usage due to increased miles per gallon. B. Flexibility to allow camber design into trailers. C. Luminescence to increase safety during low light and dark conditions. D. Composite material to maximize use of bamboo bio-composites as substitute for petroleum-based composites. E. Embedded layer(s) of conditioned bamboo for added strength and stability. F. Improved safety over Apitong by temporary cargo indentation in planks for better stability. G. Cradle-to-cradle design so end-of-life becomes beginning-of-life for other products. Resource Fiber’s bamboo biocomposite trailer decking passed nail pullout tests as compared to apitong (incumbent), was lighter weight than apitong, and used less embodied energy particularly when bamboo is sourced domestically. The planks were optimized in the lab setting to the extent possible and successfully installed on the trailer at Fontaine for field testing. Despite the process not being fully optimized due to through-heat and tooling limitations within the budget constraints, the prototype decking withstood 400 cycles of reverse fatigue loading of a 107,000 lb Caterpillar 349F which was extreme conditions of field testing by Fontaine Trailer. Resource Fiber plans to outsource production of a next round of planks with a commercial pultrusion processor, then to do a re-test with Fontaine Trailers. Tooling specific to the part is required. Long-term commercial plans are to continue outsourcing production while supplying bamboo fiber and mats. Commercial markets include heavy haul trailers, military trailers, and decking for marine, industrial and residential use.

36 MATERIALS SCIENCE↗

Shifting and Splitting of Resonance Lines due to Dynamical Friction in Plasmas

We report a quasilinear plasma transport theory that incorporates Fokker-Planck dynamical friction (drag) and pitch angle scattering is self-consistently derived from first principles for an isolated, marginally unstable mode resonating with an energetic minority species. It is found that drag fundamentally changes the structure of the wave-particle resonance, breaking its symmetry and leading to the shifting and splitting of resonance lines. In contrast, scattering broadens the resonance in a symmetric fashion. Comparison with fully nonlinear simulations shows that the proposed quasilinear system preserves the exact instability saturation amplitude and the corresponding particle redistribution of the fully nonlinear theory. Even in situations in which drag leads to a relatively small resonance shift, it still underpins major changes in the redistribution of resonant particles. This novel influence of drag is equally important in plasmas and gravitational systems. In fusion plasmas, the effects are especially pronounced for fast-ion-driven instabilities in tokamaks with low aspect ratio or negative triangularity, as evidenced by past observations. The same theory directly maps to the resonant dynamics of the rotating galactic bar and massive bodies in its orbit, providing new techniques for analyzing galactic dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-linear MHD modelling of edge localized modes suppression by resonant magnetic perturbations in ITER

Edge localized modes (ELMs) suppression by resonant magnetic perturbations (RMPs) was studied with the non-linear magneto-hydro-dynamic (MHD) code JOREK for the ITER H-mode scenarios at 15 MA, 12.5 MA, 10 MA/5.3 T. In this study, the main aim was to demonstrate that ELMs can be suppressed by RMPs while the divertor 3D footprints of heat and particle fluxes remain within divertor material limits. The unstable peeling–ballooning modes responsible for ELMs without RMPs were modelled first for each scenario using numerically accessible parameters for ITER. Then the stabilization of ELMs by RMPs was modelled with the same parameters. RMP spectra, optimized by the linear MHD MARS-F code, with main toroidal harmonics N = 2, N = 3, N = 4 have been used as boundary conditions of the computational domain of JOREK, including realistic RMP coils, main plasma, scrape off layer (SOL) divertor and realistic first wall. The model includes all relevant plasma flows: toroidal rotation, two fluid diamagnetic effects and neoclassical poloidal friction. With RMPs, the main toroidal harmonic and the non-linearly coupled harmonics remain dominant at the plasma edge, producing saturated modes and a continuous MHD turbulent transport thereby avoiding ELM crashes in all scenarios considered here. The threshold for ELM suppression was found at a maximum RMP coils current of 45 kAt–60 kAt compared to the coils maximum capability of 90 kAt. In the high beta poloidal steady-state 10 MA/5.3 T scenario, a rotating QH-mode without ELMs was observed even without RMPs. In this scenario with RMPs N = 3, N = 4 at 20 kAt maximum current in RMP coils, similar QH-mode behaviour was observed however with dominant edge harmonic corresponding to the main toroidal number of RMPs. The present MHD modelling was limited in time by few tens of ms after RMPs were switched on until the magnetic energy of the modes saturates. As a consequence the thermal energy was still evolving on this time scale, far from the ITER confinement time scale and hence only the form of 3D footprints on the divertor targets can be indicated within this set-up. Also note, that the divertor physics was missing in this model, so realistic values of fluxes are out of reach in this modelling. However the stationary 3D divertor and particle fluxes could be simply extrapolated from these results to the stationary situation considering that a large power fraction should be radiated in the core and SOL and only about 50 MW power is going to the divertor, which is an arbitrary, but reasonable number used here. The 3D footprints with RMPs show the characteristic splitting with the main RMP toroidal symmetry. The maximum radial extension of the footprints typically was ~20 cm in inner divertor and ~40 cm in outer divertor with stationary heat fluxes decreasing further out from the initial strike point from ~5 MW m ₋2 to ~1 MW m ₋2 assuming a total power in the divertor and walls is 50 MW. The heat fluxes remain within the divertor target and baffle areas, however with rather small margin in the outer divertor which could be an issue for the first wall especially in transient regimes when part of the plasma thermal energy is released due to switching on the RMP coils. This fact should be considered when RMPs are applied with a more favorable application before or soon after the L–H transition, although optimization is required to avoid increasing the L–H power threshold with RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗