Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Synodic and Semiannual Oscillations of Argon-40 in the Lunar Exosphere

The neutral mass spectrometer on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft collected a trove of exospheric data, including a set of high-quality measurements of radiogenic Ar-40 over a period of 142 days. Data synthesis studies, using well-established exosphere simulation tools, show that the LADEE argon data are consistent with an exosphere-regolith interaction that is dominated by adsorption and that the desorption process generates the Armand distribution of exit velocities. The synthesis work has uncovered an apparent semiannual oscillation of argon that is consistent with temporal sequestration in the seasonal cold traps created at the poles by the obliquity of the Moon. In addition, the LADEE data provide new insight into the pristine nature of lunar regolith, its spatially varying sorption properties, and the influence of sorption processes on the synodic oscillation of the argon exosphere.

argon-40↗

Development of Trace Contaminant Control Prototypes for the Primary Life Support System (PLSS)

Results are presented on the development of Trace Contaminant Control (TCC) Prototypes for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is non-regenerable, and the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, as well as pressure-drop calculations were used to design and test 1/6-scale and full-scale trace contaminant control system (TCCS) prototypes. Carbon sorbents were fabricated in both the granular and foam-supported forms. Sorbent performance was tested for ammonia sorption and vacuum regeneration in 1/6-scale, and pressure-drop characteristics were measured at flow rates relevant to the PLSS application.

Wojtowicz, Marek↗

Reliability Issues with PME and BME Ceramic Capacitors

Exposure of chip MnO2 tantalum capacitors to humid environments might result in increased ESR, leakage currents, and first turn-on failures. However, there is a lack of literature data on the effect of moisture on reverse bias behavior of the parts. The presence of moisture can also result in pop-corning when a high water vapor pressure develops when moisture absorbed in pores of tantalum slugs vaporizes instantly during soldering process resulting in damage to capacitors. A study of kinetics of moisture ingress to and release from active elements of capacitors would allow a better understanding of degradation mechanisms and is important for preventing failures. In this work, a technique for investigation of moisture sorption and desorption in solid chip tantalum capacitors that employs tantalum slugs as a humidity sensor have been developed and kinetics of the process analyzed for different types of capacitors at temperatures from room to 125 C. A model that relates diffusion characteristics of polymer cases and size of the slugs to characteristic times of moisture sorption has been developed. A strong effect of moisture on long-term degradation of reverse bias currents in MnO2 cathode capacitors has been demonstrated and physical mechanisms discussed.

degradation↗

Novel Aprotic Heterocyclic Anion-based Ionic Liquids for Carbon Dioxide Capture

Ionic liquids (ILs), or organic salts with melting points at or below room temperature are an incredibly versatile class of materials with many possible applications for NASA’s exploration needs. In particular, appropriately designed ILs can have a high affinity for absorbing carbon dioxide, making them excellent candidates for use as liquid sorbents in cabin air revitalization systems. Unfortunately, many of these ILs have high viscosity, which is only exacerbated by carbon dioxide uptake. High viscosity limits the rate of carbon dioxide uptake. A new class of IL sorbent containing aprotic heterocyclic anions (AHA) has been shown to offer excellent carbon dioxide uptake without a corresponding increase in viscosity. However, there is a paucity of sorption data for these AHA ILs at low partial pressures of carbon dioxide. This paper reports on the characterization of sorption behavior for AHA ILs previously reported in the literature at low concentrations of carbon dioxide and the synthesis and characterization of new, water miscible AHA ILs. Characterization of the new ILs includes measurement of density, viscosity, thermal stability, carbon dioxide capacity, carbon dioxide absorption kinetics, and water-IL vapor liquid equilibrium. Overall, these news ILs are promising alternatives to many of the commonly used IL sorbents.

Eric Townsend Fox↗

A lingering local exopshere created by a gas plume of a lunar lander

We model the expected local exosphere created by outgassing from a lunar lander plume water deposit located adjacent to a lunar lander. We assume the landing is near dawn within Lacus Mortis at 45oN. We consider a set of water desorption scenarios especially focusing on the water-surface desorption activation energy that can possess a distribution of energy states. Our initial simulation starts with a deposition surface having 1020 water molecules per square meter in a 2 km × 2 km region where 90% of the water is retained by weak water-water sorption interactions and 10% are bound by water-regolith sorption interactions. We find that the loosely bound water molecules in water-water interactions quickly desorb within hours after landing. However, water molecules bound to surface sites having a desorption activation greater than 0.7 eV were found to be retained until the source region rotated to later local times (i.e., surface temperature becomes relatively high). We found such time-delayed desorption leads to a tenuous but lingering exosphere emitted from the lander plume deposit region for many 10's of hours after landing. We also adjusted the initial condition by considering different landing local times and considered a case where 100% of the water is bound by water-regolith interactions (mimicking a porous regolith).

W.M. Farrell↗

Ammonia-Removal Efficiency By Full-Scale Carbon-Based Trace-Contaminant Sorbent Monoliths Integrated With the Rapid-Cycle Amine (RCA) Swing Bed

Results are presented on full-scale performance testing of vacuum-regenerable, carbon based sorbent monoliths for trace-contaminant (TC) removal integrated with the Rapid-Cycle Amine (RCA) swing bed for use in the Portable Life Support System (PLSS) during Extravehicular Activities (EVAs). The current state-of-art in TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. The carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on cyclic sorption-desorption of ammonia, which is a major TC of concern, were collected in a simulated PLSS ventilation loop which involved the RCA placed upstream of the Trace Contaminant Control System (TCCS). Results of testing involving pressure-swing operation of the integrated TCCS/RCA system indicate ammonia-removal efficiency exceeding 80% throughout multiple sorption-desorption cycles. This paper presents an overview of the TCCS research, the favorable results obtained, and provides insight into future work needed to further the technology development.

Marek A Wójtowicz↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

(abstract) Development of Sorbent Bed Assembly for a Periodic 10K Solid Hydrogen Cryocooler

A closed-cycle 10K sorption cryocooler is being fabricated for microgravity testing during a future space shuttle mission. A critical component of this cryogenic refrigerator is the metal hydride sorbent bed assembly (SBA). The SBA uses hydrides which absorb hydrogen gas at low pressure, (i.e., about 0.25 MPa from liquid hydrogen at 25K and below 0.2 kPa from solid hydrogen near 10K) and subsequently delivers hydrogen at nearly 10 MPa to a storage reservoir to repeat the Joule-Thomson (J-T) expansion process. The SBA includes three independent hydride beds where two contain LaNi(sub 4.8)Sn(sub 0.2) alloy and the third ZrNi. Detailed descriptions will be given for the three beds, which have specialized design features to enhance performance at each step of operation. In particular, two beds must rapidly absorb hydrogen in order for the J-T cold stage to reach 10K within two minutes from a 65K holding temperature. Performance characterization results will be compared to model analyses of the SBA.

applications microgravity↗

Comparative chromatography of chloroplast pigment

Methods for isolation of low concentration pigments of the cocklebur species are described. The methods entail two step chromatography so that the different sorption properties of the various pigments in varying column parameters can be utilized. Columnar and thin layer methods are compared. Many conditions influence separability of the chloroplasts.

Grandolfo, M.↗

Transient permeation of organic vapors through elastomeric membranes

The permeation of benzene and acetone vapors through sulfur-cured natural rubber was studied by the time-lag method. The zero concentration diffusion coefficient, was obtained by the early-time method. The Frisch time lag equation was utilized to estimate both the solubility coefficient and the additional parameter required to define the concentration-dependence of the diffusion coefficient. This form of concentration dependence was manifested by the corresponding permeability coefficient values. At low entering penetrant pressure where the transport coefficients are constant, indirect evidence was obtained that zero diffusion coefficient is the mechanically correct diffusion coefficient. The solubility coefficient values calculated for benzene vapor in natural rubber are in reasonable agreement with published equilibrium sorption data for a similar rubber compound. At higher entering penetrant pressures, average diffusion coefficients obtained at steady state tended to be larger than the corresponding average diffusion coefficients derived from the time-lags.

Curry, J. E.↗