Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

System design package for IBM system one: solar heating and domestic hot water

This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage. The system was designed for installation into a single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system was packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

Preliminary design package for solar heating and cooling systems

Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

Source record↗

Prototype solar heating and cooling systems

A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.

Source record↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

Development of a Solar Heat and Power Co-Generation System. Final CRADA Report

Final Report CRADA No. TC02152.0 Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building.

14 SOLAR ENERGY↗

Development of a Solar Heat and Power Co-Generation System. Final Report, CRADA No. TC02152.0

Final Report, CRADA No. TC02152.0. Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building. This project was originally designated as an eight (8) month project. However, it was ultimately extended by an additional thirty-five (35) months, for total project duration of forty-three (43) months.

14 SOLAR ENERGY↗

Hard X-ray emission in electron-heated solar flares - A comparison of nonthermal and thermal contributions

The spatial structure of hard X-ray emission during the impulsive phase of electron-heated solar flares is calculated. Both direct nonthermal bremsstrahlung and the thermal bremsstrahlung arising from the heated plasma are considered. The results indicate that the spread of nonthermal emission into the upper parts of the loop, through evaporation of the chromospheric target, may be more important than the appearance of a hot thermal source in the corona. The effects of varying the viewing angle to the flare loop, and of finite-size resolution element, are also considered, and results are compared with observations from the Solar Maximum Mission Hard X-Ray Imaging Spectrometer.

Brown, David G.↗

The Solar Heating and Cooling Commercial Demonstration Program at Marshall Space Flight Center - Some problems and conclusions

The origin and evolution of the Solar Heating and Cooling Commercial Demonstration Program by the Department of Energy and the Marshall Space Flight Center activities supporting this program from its conception are defined and discussed. Problems are summarized in the design and financial areas. It is concluded that the program has significantly assisted the creation of a viable solar testing and cooling industry. The cost effective procedures evolving from the program are expected to make a major contribution to reducing the effective life cycle cost of solar installation.

Middleton, R. L.↗

Pumped Thermal Electricity Storage with Supercritical CO2 Cycles and Solar Heat Input

Pumped Thermal Electricity Storage (PTES) is an energy storage device that uses grid electricity to drive a heat pump that generates hot and cold storage reservoirs. This thermal potential is later used to power a heat engine and return electricity to the grid. In this article, a PTES variant that uses supercritical carbon dioxide (sCO2) as the working fluid is introduced. sCO2-PTES cycles have higher work ratios and power densities than the systems based on ideal gases that have been investigated to date. Furthermore, sCO2- PTES cycles may achieve higher round-trip efficiencies for a given hot storage temperature (up to 78% at 560°C). The sensitivity of PTES cycles to loss factors such as isentropic efficiencies and temperature differences between the power cycle and storage fluid is investigated. A second concept whereby an sCO2- PTES cycle is integrated with concentrating solar power (CSP) is introduced. This concept ‘time-shifts’ the recompression of an sCO2 recompression cycle to a period of lower electricity prices and stores the heat. When solar heat is dispatched, the recompressor may be avoided as the required heat is obtained from storage, thereby leading to increased heat engine efficiencies. The net work output of this integrated system is 10-18% greater than the conventional recompression cycle. Combining PTES with a CSP power cycle is therefore shown to improve the dispatch of solar heat as well as providing electricity storage services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Solar heat transport fluid

The development and delivery of noncorrosive fluid subsystems are reported that are compatible with closed-loop solar heating or combined heating and hot water systems. They are also compatible with both metallic and non-metallic plumbing systems. The performance testing of a number of fluids is described.

Source record↗

Prototype solar heating and cooling systems including potable hot water

Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Solar heating and cooling system installed at RKL Controls Company, Lumberton, New Jersey

The final results of the design and operation of a computer controlled solar heated and cooled 40,000 square foot manufacturing building, sales office, and computer control center/display room are summarized. The system description, test data, major problems and resolutions, performance, operation and maintenance manual, equipment manufacturers' literature, and as-built drawings are presented. The solar system is composed of 6,000 square feet of flat plate collectors, external above ground storage subsystem, controls, absorption chiller, heat recovery, and a cooling tower.

Source record↗

Diagnostics of electron-heated solar flare models. III - Effects of tapered loop geometry and preheating

A series of hydrodynamic numerical simulations of nonthermal electron-heated solar flare atmospheres and their corresponding soft X-ray Ca XIX emission-line profiles, under the conditions of tapered flare loop geometry and/or a preheated atmosphere, is presented. The degree of tapering is parameterized by the magnetic mirror ratio, while the preheated atmosphere is parameterized by the initial upper chromospheric pressure. In a tapered flare loop, it is found that the upward motion of evaporated material is faster compared with the case where the flare loop is uniform. This is due to the diverging nozzle seen by the upflowing material. In the case where the flare atmosphere is preheated and the flare geometry is uniform, the response of the atmosphere to the electron collisional heating is slow. The upward velocity of the hydrodynamic gas is reduced due not only to the large coronal column depth, but also to the increased inertia of the overlying material. It is concluded that the only possible electron-heated scenario in which the predicted Ca XIX line profiles agree with the BCS observations is when the impulsive flare starts in a preheated dense corona.

Emslie, A. G.↗

Solar heating system

A system is disclosed for using solar energy to heat the interior of a structure. The system utilizes a low cost solar collector to heat a recirculating air mass which then flows through a series of interconnected ducts and passageways without the use of exterior fans or blowers. Heat is transferred from the air mass to the structure's interior and the air mass is then reheated.

Jensen, R. N.↗

System design package for solar heating and cooling site data acquisition subsystem

The Site Data Acquisition Subsystem (SDAS) designed to collect data from sensors located on residential or commercial buildings using a solar heating and/or cooling system is described. It takes the data obtained from sensors located on the solar system, processes the data into suitable format, stores the data for a period of time, and provides the capability for either telephone retrieval by the central data processing system or manual retrieval of the data for transfer to a central site. The SDAS is also designed so that it will not degrade the operation of the solar heating/cooling system which it is monitoring.

Source record↗

Solar heating and cooling buildings

Sunshine is available in differing amounts everywhere in the world and the easiest method of capturing it is by absorption in the form of thermal energy (heat). Therefore, it is logical to utilize it directly in the heating and cooling of buildings and avoid losses that would occur by conversion to some other form. It may be emphasized that of the total energy consumed annually in the U.S., about 25% is used for heating and cooling in buildings. It is generally agreed that of all the possible widespread uses of solar energy, this application has the highest probability of success in the near term. Although there are significant uncertainties associated with some technological and economic aspects, they do not loom as large as those associated with other potentially significant applications, such as electrical power generation. It may, however, be noted that solar electrical power generation at the building site, or at a centralized station is an excellent long term prospect. Approximately 25 experimental solar heated structures have been built in various parts of the world.

Source record↗

Solar Heating and Cooling Development Program

Heating is practical now, but cooling needs more development. Report describes program for design and development of solar heating and cooling systems having high performance, low cost and modular application. Describes main technical features of each of systems. Presents summary of performance and costs.

Aaen, R.↗