Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar Plus Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States, 2022 Edition

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The latest edition of the report focuses on systems installed through year-end 2021, and is based on data from roughly 2.5 million systems. New to the report this year is an expanded coverage of paired PV-plus-storage systems, including details on system design and pricing trends. The report describes trends related to: -Project characteristics, including system size, module efficiencies, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and non-residential customer segmentation ownership -Median installed-price trends, both nationally and by state, including preliminary data for first half of 2022 -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive and econometric analysis

14 SOLAR ENERGY↗

Identifying Barriers to Solar and Storage Hybrids: Modeled vs. empirical wholesale market value and net-value for co-located solar + storage projects [Slides]

Large-scale (1MW+) co-located solar and battery storage projects are expanding rapidly in the United States, but their realized contribution to the bulk power system remains poorly understood because public project-level operating data are limited. The Lawrence Berkeley National Laboratory estimates the wholesale market value of 280 operational photovoltaic-plus-storage (PV+S) projects across the seven ISOs/RTOs and 19 additional balancing authorities, representing roughly 95% of the U.S. PV+S fleet in 2024. We model optimized hourly dispatch under energy, capacity, and ancillary-service market opportunities and compare the resulting value with standalone PV value, project-specific levelized cost estimates, and empirical operating or revenue data where available.

14 SOLAR ENERGY↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Techno-Economic Assessment of Geothermal Power Plants Hybridized with Solar Heat and Thermal Storage

Geothermal power plants may experience a decrease in power output over time due to a reduction in either mass flow rate, temperature or pressure of the resource. A recent study quantified the temperature drawdown of U.S. double-flash geothermal power plants at 0.8% per year. Hybridizing existing geothermal plants with other renewable power sources to exploit the unused capacity of the geothermal power block has become an area of increasing interest. For instance, a geothermal power plant may be retrofitted with heat from a concentrating solar field. In addition, geothermal may be integrated with solar in a new-build site with the aim of combining the benefits of both technologies -- i.e. the baseload generation of geothermal, plus the relatively high efficiency of concentrating solar power. In this article, we give an overview of hybrid geothermal-solar projects undertaken at the National Renewable Energy Laboratory in collaboration with various partners. We investigate the retrofit of double-flash and binary geothermal plants with solar heat. Off-design models are developed and validated with operational data. Annual simulations evaluate the hourly performance, the benefits of thermal storage, and are used to calculate economic metrics. Finally, we discuss the implications of integrating solar and geothermal in a new greenfield site.

15 GEOTHERMAL ENERGY↗

Hybrid Systems to Enable High Penetration PV

A model for PV plus energy storage and fuel cells was developed in the System Advisor Model (SAM). This model was used to evaluate the ramp rate and interconnection capacity factor for a hypothetical utility-scale plant for several configuration options. For PV only, the plant experienced 3345 violations of a 10%/minute ramp up limitation and a interconnection capacity factor of 17.6%. Adding a battery reduced the violations to 154 per year and the magnitude of the average violation to 2%. Adding a fuel cell to the PV system increased the capacity factor to 78% without improving ramp violations. Using a combined PV plus storage plus fuel cell arrangement maintained the improved capacity factor while reducing ramp up violations to 23, illustrating the potential to operate a hybrid system both to enable grid integration requirements and increase utilization of the interconnection.

14 SOLAR ENERGY↗

Overhead Protection Increases Fuel Quality and Natural Drying of Leaf-On Woody Biomass Storage Piles

Short-rotation woody crops (SRWC) have the potential to make substantial contributions to the supply of biomass feedstock for the production of biofuels and bioproducts. This study evaluated changes in the fuel quality (moisture, ash, and heating value) of stored spring harvested shrub willow (Salix spp.) and hybrid poplar (Populus spp.) chips with respect to pile protection treatments, location within the storage piles, and length of storage. Leaf-on willow and poplar were harvested in the spring, and wood chips and foliage with moisture content in the range of 42.1% to 49.9% (w.b.) were stored in piles for five months, from May to October 2016. Three protection treatments were randomly assigned to the piles. The control treatment had no cover (NC), so piles were exposed to direct solar radiation and rainfall. The second treatment had a canopy (C) installed above the piles to limit direct rainfall. The final treatment had a canopy plus a dome aeration system (CD) installed over the piles. Covering piles reduced and maintained the low moisture content in wood chip piles. Within 30 days of establishment, the moisture content in the core of the C pile decreased to less than 30%, and was maintained between 24%–26% until the end of the storage period. Conversely, the moisture content in the NC piles decreased in the first two months, but then increased to the original moisture content in the core (>45 cm deep) and up to 70% of the original moisture content in the shell (<45 cm deep). For all the treatments in the tested conditions, the core material dried faster than the shell material. The higher heating value (HHV) across all the treatments increased slightly from 18.31 ± 0.06 MJ/kg at harvest to 18.76 ± 0.21 MJ/kg at the end of the storage period. The lower heating value (LHV) increased by about 50% in the C and CD piles by the end of the storage period. However, in the NC piles, the LHV decreased by 3% in the core and 52% in the shell. Leaf-on SRWC biomass stored in piles created in late spring under climatic conditions in central and northern New York showed differing moisture contents when stored for over 60–90 days. Overhead protection could be used to preserve or improve the fuel quality in terms of the moisture content and heating value if more than two months of storage are required. However, the implementation of such management practice will depend on whether the end users are willing to pay a higher price for dryer biomass and biomass with a higher LHV.

54 ENVIRONMENTAL SCIENCES↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rosario Strait Tidal Energy plus Energy Storage — Preliminary Economic Assessment

The Orcas Power and Light Co-op (OPALCO) is a non-profit utility that provides energy services to approximately 11,700 customers across 20 islands in San Juan County, Washington. OPALCO is developing a diverse set of local renewable energy resources to reduce dependence on mainland Washington State for energy and to reduce the regional need for fossil-fueled power. OPALCO’s load doubles in winter but solar production is roughly 20% of levels reached in summer periods. Tidal energy is strong year-round, night and day, and is predictable, requiring much less storage to firm it. To assess the technical and economic feasibility of tidal power, working in combination with multiple other distributed energy resources (DERs), Argonne National Laboratory (Argonne) employed an optimization model to evaluate several economic benefits associated with varying scales of tidal power of between 2.4 and 9.6 megawatts (MW) and other DERs. In addition to existing photovoltaic (PV) and battery energy storage system (BESS) resources located on Decatur Island, Argonne also evaluated the addition of a BESS on southern Orcas Island with power and energy capacities ranging from 1-4 MW and 2-4 hours in storage duration.

25 ENERGY STORAGE↗

Renewable Hydrogen Carrier Carbohydrate: Constructing the Carbon-Neutral Carbohydrate Economy

Abstract The hydrogen economy presents an appealing energy future but its implementation must solve numerous problems ranging from low-cost sustainable production, high-density storage, costly infrastructure, to eliminating safety concern. The use of renewable carbohydrate as a high-density hydrogen carrier and energy source for hydrogen production is possible due to emerging cell-free synthetic biology technology called cell-free synthetic pathway biotransformation (SyPaB). Assembly of numerous enzymes and co-enzymes in vitro can create complicated set of biological reactions or pathways that microorganisms cannot complete, for example, C6H10O5 (aq) + 7 H2O (l) 12 H2 (g) + 6 CO2 (g) (PLoS One 2007, 2:e456). Thanks to 100% selectivity of enzymes, modest reaction conditions, and high-purity of generated hydrogen, carbohydrate is a promising hydrogen carrier for end users. Gravimetric density of carbohydrate is 14.8 H2 mass% if water can be recycled from PEM fuel cells or 8.33% H2 mass% without water recycling. Renewable carbohydrate can be isolated from plant biomass or would be produced from a combination of solar electricity/hydrogen and carbon dioxide fixation mediated by high-efficiency artificial photosynthesis mediated by SyPaB. The construction of this carbon-neutral carbohydrate economy would address numerous sustainability challenges, such as electricity and hydrogen storage, CO2 fixation and long-term storage, water conservation, transportation fuel production, plus feed and food production.

: artificial photosynthesis↗

Farm-level Interactions Study of a Novel Tri-port Soft-switching Medium-Voltage String Inverter (MVSI) based Large-scale PV-Plus-Storage Farms

A medium-voltage photovoltaic power conversion unit supported by battery based on a novel topology of soft switching solid state transformer is presented in this paper. It can reduce the Levelized Cost of Energy (LCOE) of PVS farm in an extended degree. However, its capability to provide grid-support services, such as frequency response, reactive power support, etc, have not been demonstrated. A series/parallel combination of these modules form a large 20 MVA solar farm. To validate them with reduced computation burden, a small-signal model of MVSI is firstly derived and validated in this paper. The model has been validated to match the full-switch model in both steady-state and dynamic conditions. Next, a farm-level simulation based on the proved small-signal model was implemented to demonstrate grid-support services. Real irradiation date from NREL is used to show the operational capabilities of the system. As a result, the overall farm is simulated based on MATLAB/Simulink domain to check the performance for various cases namely: power transfer from dc-ac side, reactive power support during grid voltage sag and utilization of battery during grid voltage disturbance or partial shading over PV panels.

14 SOLAR ENERGY↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Solar Plus: Strategies for Oregon and Washington

The Solar Plus initiative convened leaders from the State Energy Offices in Oregon and Washington, plus representatives from utilities, regulators, the solar industry and community-based organizations to tap into the region’s unique opportunities to develop distributed solar with an emphasis on equity and inclusion of vulnerable communities.

14 SOLAR ENERGY↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗