Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sink Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermodynamic analysis and optimization of supercritical carbon dioxide Brayton cycles for use with low-grade geothermal heat sources

The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic optimization with flexible heat integration of a solar parabolic trough collector plant with thermal energy storage used for industrial process heat

There is an increasing need to reduce fossil fuel consumption used for industrial process heat to slow the effects of climate change. Using solar thermal heat is a viable way to replace fossil fuel use, but solar industrial process heat plants have limited implementation due to large upfront costs and inefficiencies from the inherent variability from solar energy. Having more flexible and optimized control over these plants can enable them to be more efficient. Here in this work, a solar industrial process heat plant with thermal energy storage that can flexibly collect and deliver heat to two industrial processes (flexible heat integration) is dynamically modeled with control setpoints found by a dynamic optimization method. The optimized case can increase the solar efficiency of the plant by 7.5% on average relative to a base case. The results show that it is best to collect heat at lower temperatures for all but ideal solar conditions, only medium to high quality heat should be stored in large quantities, and exchanging heat with a lower temperature heat sink is generally more efficient. The optimized case is able to reduce the levelized cost of heat of the plant to $31.83/MWh th compared to a base case value of $34.10/MWh th . The optimized case can reduce emissions by 22.2% compared to a plant which uses only natural gas. This work shows that dynamic optimization with flexible heat integration can be a cost-effective way to increase efficiency so that more of these types of plants can be implemented.

14 SOLAR ENERGY↗

Site Ambient Temperatures and Operating Schedules for EIC - Utility CW Considerations

The heat dissipated by the EIC accelerator system and components is ultimately removed by the conventional water-cooling systems that will be ultimately dissipated the waste heat to the atmosphere. An estimated 45 MW of heat will be dissipated to water during full beam operation and that will need to be effectively rejected to the atmosphere. Approximately 50% of the heat is required to be rejected to a low temperature heat sink that cannot be achieved by an evaporative cooling tower during summer. To operate during these summer months, a secondary chilled water refrigeration system will be required that would increase the cost of the cooling water system. Further, operating chiller compressor in the summer months will increase the energy consumption of the machine. This analysis is being prepared to evaluate the impact on operating and capital costs on the cooling system for various summer operating schedules while utilizing the most cost-effective scenario of an evaporative cooling system. The technology selection for the various heat sinks is addressed in a separate write-up and are not expected to change the conclusions of this write-up.

43 PARTICLE ACCELERATORS↗

Characterization of Mk-IV and EBR-II X441A Metallic Fuel Pins for the THOR-C-2 and THOR-M-TOP-1 Experiments: Results from Post-Transient Neutron Tomography of THOR-C-2 Capsule and Pre-transient Non-Destructive and Destructive Examination of DP 36 and DP 40 (Rev.1)

Current interest in sodium-cooled fast reactor designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced-reactor fuel technology development. A Fuel Safety Research and Development (FSRD) program for metallic fast reactor fuels has been created to achieve comprehensive safety testing within the re-commissioned Transient Reactor Test (TREAT) facility at the Idaho National Laboratory. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under anticipated operational occurrences and severe accident scenarios. Throughout historical testing within the Experimental Breeder Reactor (EBR)-II and the Fast Flux Test Facility, fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds rely heavily on fuel composition and irradiation history. In advancing the FSRD program, two planned transient heating experiments are at various stages of completion. The Temperature Heat sink Overpower Response (THOR)-C-2, fueled with an unirradiated Mk IV U-10Zr pin, has undergone transient irradiation in TREAT and post-transient three-dimensional neutron tomography. Additionally, pre-transient characterization of test and sibling U-19Pu-10Zr pins for THOR-M-TOP-1 was evaluated by both non-destructive and destructive methods. The test and sibling pins were selected from previously irradiated EBR-II experiment X441A. Both pins underwent visual examination, precise gamma spectrometry, two-dimensional neutron radiography, and element contact profilometry while the sibling pin was additionally subjected to sectioning and optical microscopy. THOR-C-2 radiography captured the fuel and cladding relocation during the intermediate transient at the top and bottom of the THOR capsule, allowing key features to be linked to the pin’s measured thermal response. For THOR M TOP 1, a solid baseline for steady-state behavior has been established. No anomalous features were identified in either the test or sibling pin. Defining characteristics and features were recorded for further comparisons.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Standard reference materials: Thermal conductivity of electrolytic iron, SRM 734, from 4 to 300 K

Thermal conductivity data were obtained by the axial one-dimensional heat flow method for a cylindrical rod 3.6 mm in diameter and 23 cm long with an electric heater at one end and a temperature controlled sink at the other. Variability of this iron was studied by means of electrical residual resistivity ratio measurements on 63 specimens. This study showed that with a two-hour anneal at 1000 C one can obtain a thermal conductivity Standard Reference Material that has variability of less than 1% in thermal conductivity.

Hust, J. G.↗

Comparative cut-bar thermal conductivity apparatus.

Construction details, error analysis, and typical data for a rapid comparative device for thermal conductivity measurements are presented. The apparatus consists of a comparative cut-bar arrangement contained in a bell-jar. The cylinder shaped specimen is placed between two ARMCO-iron meter bars of the same diameter. The upper bar is equipped with a heater, while the lower one is terminated in a heat sink. The temperature gradient along the bars is measured with a series of copper/constantan microthermocouples, spot welded to them. The assembly is held together by loading the bars to a desired pressure, via a pneumatic cylinder. Contact resistance at the boundaries between the specimen and the meter bars is minimized by using a Hg/In/Ga alloy film at the interface and sufficient loading force. The gradients determined for the meter bars then may be extrapolated to the boundaries yielding the temperature drop along the specimen. Using two different length specimens, the magnitude of the temperature drop across the interface can be computed, or the true gradient along the specimen can be obtained from the difference in overall temperature drops and lengths.

Gaal, P. S.↗

Development of a short pulsed solid propellant plasma thruster

The experimental results are summarized that were obtained in the development of a Teflon solid propellant pulsed plasma thruster. The feasibility was established of storing and feeding solid propellant in the form of an open circular loop into an operational thruster. This technique was verified to be practical by feeding over 20 inches of Teflon into a micro-thruster over an accumulated life test of 1858 hours. High energy density capacitors were evaluated under vacuum conditions when the capacitor is coupled directly to a plasma thruster. Numerous early capacitor failures were encountered. It was concluded that essentially all of the failures encountered in a vacuum environment are due to an internal electrical breakdown that will occur inside a capacitor that is not truly hermetically sealed. A steady input power significantly in excess of 130 watts can safely be tolerated if heat conduction can be provided to a sink whose temperature is about 16 C. A vacuum life test of the capacitor bank was carried out while discharging into a milli-lb. (milli-Newton) type pulsed plasma thruster. More than 1500 hours of vacuum testing of this milli-Newton type system has been accumulated without any capacitor problems. Recommendations are made for future capacitor designs.

Guman, W. J.↗

Solar meter with silicon photocell

Instrument for measuring light falling on given spot uses simple silicon photovoltaic cell as sensing element. It measures all light at location: direct, scattered, reflected, or reradiated. Silicon cell is coated with thick antireflecting layer of silicon monoxide and is enclosed in glass dome. Large heat sink reduces temperature fluctuations. Instrument is accurate within few percentage points over angle of Sun's arc across sky.

Yanow, G.↗

Array Of Sensors Measures Broadband Radiation

Multiple broadband radiation sensors aimed at various portions of total field of view. All sensors mounted in supporting frame, serving as common heat sink and temperature reference. Each sensor includes heater winding and differential-temperature-sensing bridge circuit. Power in heater winding adjusted repeatedly in effort to balance bridge circuit. Intended to be used aboard satellite in orbit around Earth to measure total radiation emitted, at various viewing angles, by mosaic of "footprint" areas (each defined by its viewing angle) on surface of Earth. Modified versions of array useful for angle-resolved measurements of broadband radiation in laboratory and field settings on Earth.

Hoffman, James W.↗

Zero-G Thermodynamic Venting System (TVS) Performance Prediction Program

This report documents the Zero-g Thermodynamic Venting System (TVS) performance prediction computer program. The zero-g TVS is a device that destratifies and rejects environmentally induced zero-g thermal gradients in the LH2 storage transfer system. A recirculation pump and spray injection manifold recirculates liquid throughout the length of the tank thereby destratifying both the ullage gas and liquid bulk. Heat rejection is accomplished by the opening of the TVS control valve which allows a small flow rate to expand to a low pressure thereby producing a low temperature heat sink which is used to absorb heat from the recirculating liquid flow. The program was written in FORTRAN 77 language on the HP-9000 and IBM PC computers. It can be run on various platforms with a FORTRAN compiler.

Nguyen, Han↗

Design and Performance of the Astro-E/XRS Microcalorimeter Array and Anti-Coincidence Detector

The XRS instrument has an array of 32 micro-calorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of 9 eV at 3 keV and 11 eV at 6 keV. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, operating temperature, thermistor size, absorber choice, and means of attaching the absorber to the thermistor bearing element. We will present representative performance data, though a more detailed presentation of the results of the instrument calibration is presented elsewhere in these proceedings. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance in conjunction with the array.

Stahle, C. K.↗

Continuous Sub-Kelvin Cooling from an Adiabatic Demagnetization Refrigerator

We present the current state of development for a continuous magnetic refrigeration system capable of cooling a detector array or other payload to temperatures below 50 mK. This adiabatic demagnetization refrigerator contains four-stages that are cycling continuously yet present a constant ultra-low temperature heat sink at one physical location within the refrigerator. Two different configurations of essentially the same cooler will be presented where the difference is in the physical layout of the stages and the type of heat sink used for the refrigerator's heat rejection.

Magnetic Cooling↗

Ground Slope Effects on Lander Radiator Performance

Two sensitivity studies were performed to examine the drop in radiator heat rejection from slopes. Study #1 used a 5.5m tall reduced order asset to represent a small-lander/rover. Study #2 used a 20m asset represent a tall lander. The assets had body mounted horizontal, 45º inward-tilted, and vertical radiator orientations. The impact of slopes on different radiator orientations and on radiators pointing different directions (i.e., slope verses sun) was investigated. The studies were conducted at a polar location of -82.5ºS to capture the incident solar flux at the northmost, and therefore the hottest, range of potential Artemis landing sites (Mons Mouton Plateau).

Lunar Slope↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This, in turn, is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study, we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in enhanced geothermal system binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data, we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost. These results make a case for the inclusion of location-based weather data as inputs to supply curves that are used in capacity expansion models for the prediction of future geothermal deployment scenarios.

ambient temperature↗

Aera-Mip: Emission Pathways, Remaining Budgets, and Carbon Cycle Dynamics Compatible With 1.5 and 2 °C Global Warming Stabilization

While international climate policies now focus on limiting global warming to well below 2 °C or pursuing a 1.5 °C level of global warming, the climate modelling community has not provided an experimental design in which all Earth system models (ESMs) converge and stabilize at the same prescribed global warming levels. This gap hampers accurate estimations based on comprehensive ESMs of the carbon emission pathways and budgets needed to meet such agreed warming levels and of the associated climate impacts under temperature stabilization. Here, we apply the Adaptive Emission Reduction Approach (AERA) with ESMs to provide such simulations in which all models converge at 1.5 and 2.0 °C warming levels by adjusting their emissions over time. These emission-driven simulations provide a wide range of emission pathways and resulting atmospheric CO 2 projections for a given warming level, uncovering uncertainty ranges that were previously missing in the traditional Coupled Model Intercomparison Project (CMIP) scenarios with prescribed greenhouse gas concentration pathways. Meeting the 1.5 °C warming level requires a 40 % (full model range: 7 % to 76 %) reduction in multi-model mean CO 2 -forcing-equivalent (CO 2 -fe) emissions from 2025 to 2030, a 98 % (57 % to 127 %) reduction from 2025 to 2050, and a stabilization at 1.0 (−1.7 to 2.9) PgC yr−1 from 2100 onward after the 1.5 °C global warming level is reached. Meeting the 2.0 °C warming level requires a 47 % (8 % to 92 %) reduction in multi-model mean CO 2 -fe emissions until 2050 and a stabilization at 1.7 (−1.5 to 2.7) PgC yr−1 from 2100 onward. The on-average positive emissions under stabilized global temperatures are the result of a decreasing transient climate response to cumulative CO 2 -fe emissions over time under stabilized global warming. This evolution is consistent with a slightly negative zero emissions commitment – initially assumed to be zero – and leads to an increase in the post-2025 CO 2 -fe emission budget by a factor of 2.2 (−0.8 to 6.9) by 2150 for the 1.5 °C warming level and a factor of 1.4 (0.9 to 2.4) for the 2.0 °C warming level compared to its first estimate in 2025. The median CO 2 -only carbon budget by 2150, relative to 2020, is 800 GtCO 2 for the 1.5 °C warming level and 2250 GtCO 2 for the 2.0 °C warming level. These median values exceed the median IPCC AR6 estimates by 60 % for the 1.5 °C warming level and 67 % for 2.0 °C. Some of the differences may be explained by the choice of the mitigation scenario for non-CO 2 radiative agents. Our simulations highlight shifts in carbon uptake dynamics under stabilized temperature, such as a cessation of the carbon sinks in the North Atlantic and in tropical forests. On the other hand, the Southern Ocean remains a carbon sink centuries after temperatures stabilize. Overall, this new type of warming-level-based emission-driven simulation offers a more coherent assessment across climate models and opens up a wide range of possibilities for studying both the carbon cycle and climate impacts, such as extreme events, under climate stabilization.

Adaptive Emission Reduction Approach↗

Temperature Control with Two Parallel Small Loop Heat Pipes for GLM Program

The concept of temperature control of an electronic component using a single Loop Heat Pipe (LHP) is well established for Aerospace applications. Using two LHPs is often desirable for redundancy/reliability reasons or for increasing the overall heat source-sink thermal conductance. This effort elaborates on temperature controlling operation of a thermal system that includes two small ammonia LHPs thermally coupled together at the evaporator end as well as at the condenser end and operating "in parallel". A transient model of the LHP system was developed on the Thermal Desktop (TradeMark) platform to understand some fundamental details of such parallel operation of the two LHPs. Extensive thermal-vacuum testing was conducted with two thermally coupled LHPs operating simultaneously as well as with only one LHP operating at a time. This paper outlines the temperature control procedures for two LHPs operating simultaneously with widely varying sink temperatures. The test data obtained during the thermal-vacuum testing, with both LHPs running simultaneously in comparison with only one LHP operating at a time, are presented with detailed explanations.

0000↗

Controls of CO2 sources and sinks in the earth scale surface ocean - Temperature and nutrients

Several regions in the ocean in which disequilibrium persists on an annual avarage between CO2 in the surface water and the overlying atmosphere were examined using various models in which CO2 does cycle in a steady state at which sources (ocean outgassing) and sinks (ingassing) are in balance. The relative values of the surface temperature and surface nutrients, the two major contributors to the CO2 source and/or sink properties, are determined. Results from models with two ocean surfaces indicate that the sink in the north Atlantic and the sources in the equatorial Atlantic and Pacific are all dominated by the global temperature patterns. Results from ocean models with three surface zones show that, in the equatorial Pacific, the temperature control is responsible for over 50 percent (and, possibly, for almost 70 percent) of the CO2 outgassing, with the balance coming from the earth scale surface nutrient structure.

Volk, Tyler↗