Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Secondary particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Influence of surfactants on the microstructure and electrochemical performance of the tin oxide anode in lithium ion batteries

Highlights: • CTAB and SDS alter the formation of SnO{sub 2} from nanosheets to nanocubes during oxalate precipitation. • The CTAB concentration affects the SnO{sub 2} crystal growth direction, morphology and size. • The SnO{sub 2} anode synthesized using CTAB exhibited superior electrochemical performance. • Proposed a mechanism of influence of surfactant on SnO{sub 2} in the precipitation and annealing process. - Abstract: Different SnO{sub 2} micro–nano structures are prepared by precipitation using a surfactant-assisted process. The surfactants, such as cetyltriethylammonium bromide (CTAB) or sodium dodecyl benzene sulfonate (SDBS), can change the crystal growth direction and microstructure of SnO{sub 2} primary and secondary particles. Larger SnO{sub 2} nanosheets were synthesized without surfactant, and micro-fragments composed of small nanospheres or nanocubes were synthesized using CTAB and SDBS. The CTAB-assisted process resulted in smaller primary particles and larger specific surface area and larger pore volume, as a lithium-ion-battery anode that exhibits superior electrochemical performance compared to the other two anodes. Further investigation showed that the concentration of CTAB had a substantial influence on the growth of the crystal face, morphology and size of the SnO{sub 2} secondary particles, which influenced the electrochemical performance of the anode. A simple mechanism for the influence of surfactants on SnO{sub 2} morphology and size in the precipitation and annealing process is proposed.

36 MATERIALS SCIENCE↗

Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-290: Secondary Dose Monitoring Using Scintillating Fibers in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

Purpose: To monitor the secondary dose distribution originating from a water phantom during proton therapy of prostate cancer using scintillating fibers. Methods: The Geant4 Monte Carlo toolkit version 9.6.p02 was used to simulate prostate cancer proton therapy based treatments. Two cases were studied. In the first case, 8 × 8 = 64 equally spaced fibers inside three 4 × 4 × 2.54 cmm{sup 3} DuPont™ Delrin blocks were used to monitor the emission of secondary particles in the transverse (left and right) and distal regions relative to the beam direction. In the second case, a scintillating block with a thickness of 2.54 cm and equal vertical and longitudinal dimensions as the water phantom was used. Geometrical cuts were used to extract the energy deposited in each fiber and the scintillating block. Results: The transverse dose distributions from secondary particles in both cases agree within <5% and with a very good symmetry. The energy deposited not only gradually increases as one moves from the peripheral row fibers towards the center of the block (aligned with the center of the prostate) but also decreases as one goes from the frontal to distal region of the block. The ratio of the doses from the prostate to the ones in the middle two rows of fibers showed a linear relationship with a slope (−3.55±2.26) × 10−5 MeV per treatment Gy. The distal detectors recorded a very small energy deposited due to water attenuation. Conclusion: With a good calibration and the ability to define a good correlation between the dose to the external fibers and the prostate, such fibers can be used for real time dose verification to the target.

60 APPLIED LIFE SCIENCES↗

SU-D-BRC-06: Experimental and Monte Carlo Studies of Fluence Corrections for Graphite Calorimetry in Proton Therapy

Purpose: For photon and electron beams, the standard device used to measure absorbed dose is a calorimeter. Standards laboratories are currently working on the establishment of graphite calorimeters as a primary standard for proton beams. To provide a practical method for graphite calorimetry, it is necessary to convert dose to graphite to dose to water, requiring knowledge of the water-to-graphite stopping-power ratio and the fluence correction factor. This study aims to present a novel method to determine fluence corrections experimentally, and to apply this methodology to low- and high-energy proton beams. Methods: Measurements were performed in 60 MeV and 180 MeV proton beams. Experimental information was obtained from depth-dose ionization chamber measurements performed in a water phantom. This was repeated with different thicknesses of graphite plates in front of the water phantom. One distinct advantage of this method is that only ionization chamber perturbation factors for water are required. Fluence corrections were also obtained through Monte Carlo simulations for comparison with the experiments. Results: The experimental observations made in this study confirm the Monte Carlo results. Overall, fluence corrections between water and graphite increased with depth, with a maximum correction of 1% for the low-energy beam and 4% for the high-energy beam. The results also showed that a fraction of the secondary particles generated in proton therapy beams do not have enough energy to cross the ionization chamber wall; thus, their contribution is not accounted for in the measured fluence corrections. This effect shows up as a discrepancy in fluence corrections of 1% and has been confirmed by simulations of the experimental setup. Conclusion: Fluence corrections derived by experiment do not account for low-energy secondary particles that are stopped in the ion chamber wall. This work will contribute to a practical graphite calorimetry technique for determining absolute dose to water in proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Essential effect of the electrolyte on the mechanical and chemical degradation of LiNi 0.8 Co 0.15 Al 0.05 O 2 cathodes upon long-term cycling

Capacity fading during long-term cycling (>1500×) is still a critical challenge for Li-ion batteries that use Ni-rich layered oxides, e.g. LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA), as the cathode. Microcracks have been previously recognized as one of the primary reasons for the observed capacity fade. Although there exists a generally developed mechanical understanding of microcracks, the role of the electrolyte has not been clearly understood, especially after extended cycling and at the atomic scale. Here, we unveil the microstructural evolution of spherical NCA secondary particles after long-term cycling using scanning transmission electron microscopy accompanied with electron energy loss spectroscopy. In this work, we found that the microcracks initiated and grew through grain boundaries, which then serve as the pathway for electrolyte penetration into secondary NCA particles. Additionally, the rock-salt phase reconstruction is prone to occur at the (003) surfaces of the primary particles or the crack surfaces, largely due to electrolyte (LiPF 6 EC/EMC) corrosion. Crack propagation within the NCA grains is primarily a joint consequence from electrolyte corrosion and mechanical strain during lithiation/delithiation. During extended cycling, due to the distinctive surface facets, the primary grains located in the center of the secondary particles experience more intensive electrolyte corrosion, leading to a reduced contact with nearby particles, impairing the overall capacity. These results establish the initiation and growth mechanism of microcracks and voids in NCA-based cathodes during cycling and point out the role of the electrolyte in affecting the degradation of NCA-based cathodes.

25 ENERGY STORAGE↗

New physics at a neutron beam dump

We find a new utility of neutrons, usually treated as an experimental nuisance causing unwanted background, in probing new physics signals. The new physics signals can either be radiated from neutrons (neutron bremsstrahlung) or appear through secondary particles from neutron-on-target interactions, dubbed “neutron beam dump.” As a concrete example, we take the FASER/FASER2 experiment as a “factory” of high-energy neutrons that interact with the iron dump. We find that if new physics particles had the same interaction strength to protons and neutrons, their production rate via neutron-initiated bremsstrahlung would be comparable to that via proton-initiated ones, in terms of the resulting flux and the range of couplings that can be probed. The neutron bremsstrahlung can be used, for instance, to probe dark gauge bosons with nonzero neutron coupling. In particular, we investigate protophobic gauge bosons and find that FASER/FASER2 can probe new parameter space. We also illustrate the possibility of neutron-induced secondary particles by considering axionlike particles with electron couplings. We conclude that the physics potential of FASER/FASER2 in terms of new physics searches can be greatly extended and improved with the inclusion of neutron interactions. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Cosmic ray interaction event generator SIBYLL 2.1

The cosmic ray interaction event generator Sibyll is widely used in extensive air shower simulations. We describe in detail the properties of Sibyll 2.1 and the differences with the original version 1.7. The major structural improvements are the possibility to have multiple soft interactions, introduction of new parton density functions, and an improved treatment of diffraction. Sibyll 2.1 gives better agreement with fixed target and collider data, especially for the inelastic cross sections and multiplicities of secondary particles. Shortcomings and suggestions for future improvements are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on long-duration deep space missions for human exploration which offers no options for a quick emergency return to Earth. The combination of long mission duration with no quick emergency return option leads to unprecedented spacecraft system safety and reliability requirements. It is important that spacecraft avionics systems for human deep space missions are not susceptible to Single Event Effect (SEE) failures caused by space radiation (primarily the continuous galactic cosmic ray background and the occasional solar particle event) interactions with electronic components and systems. SEE effects are typically managed during the design, development, and test (DD&T) phase of spacecraft development by using heritage hardware (if possible) and through extensive component level testing, followed by system level failure analysis tasks that are both time consuming and costly. The ultimate product of the SEE DD&T program is a prediction of spacecraft avionics reliability in the flight environment produced using various nuclear reaction and transport codes in combination with the component and subsystem level radiation test data. Previous work by Koontz, et al.1 utilized FLUKA, a Monte Carlo nuclear reaction and transport code, to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data for a variety of spacecraft and space flight environments. However, FLUKA has a long run-time (on the order of days). CREME962, an easy to use deterministic code offering short run times, was also compared with FLUKA predictions and in-flight data. CREME96, though fast and easy to use, has not been updated in several years and underestimates secondary particle shower effects in spacecraft structural shielding mass. Thus, this paper will investigate the use of HZETRN 20103, a fast and easy to use deterministic transport code, similar to CREME96, that was developed at NASA Langley Research Center primarily for flight crew ionizing radiation dose assessments. HZETRN 2010 includes updates to address secondary particle shower effects more accurately, and might be used as another tool to verify spacecraft avionics system reliability in space flight SEE environments.

Rojdev, Kristina↗

Gamma ray lines from a universal extra dimension

Indirect Dark Matter searches are based on the observation of secondary particles produced by the annihilation or decay of Dark Matter. Among them, gamma-rays are perhaps the most promising messengers, as they do not suffer deflection or absorption on Galactic scales, so their observation would directly reveal the position and the energy spectrum of the emitting source. Here, we study the detailed gamma-ray energy spectrum of Kaluza-Klein Dark Matter in a theory with 5 Universal Extra Dimensions. We focus in particular on the two body annihilation of Dark Matter particles into a photon and another particle, which produces monochromatic photons, resulting in a line in the energy spectrum of gamma rays. Previous calculations in the context of the five dimensional UED model have computed the line signal from annihilations into γγ, but we extend these results to include γZ and γH final states. We find that these spectral lines are subdominant compared to the predicted γγ signal, but they would be important as follow-up signals in the event of the observation of the γγ line, in order to distinguish the 5d UED model from other theoretical scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Petawatt Laser-Induced Muon Source for Rapid High-Z Material Detection

A proof-of-concept investigation of a rapid detection system for shielded high-Z material using a petawatt laser-based muon source is presented. Unlike cosmic-ray muons, a laser-induced muon beam has unique characteristics that can be exploited for use in a rapid detection system. These characteristics include: (1) a near-point source of muons, (2) well-characterized muon energies, and (3) directionality of the beam. A detector system is being developed that combines multiple muon detection technologies to characterize an active muon source. This detection system and the associated data acquisition and analysis techniques are designed to search for deflections of the muon beam as it passes through high-Z materials. Additionally, the ability of the system to differentiate muons from the expected secondary particles, such as high-energy gammas and electrons, is being explored. The detector system’s ability to differentiate muons from other particles, show muon angular distribution, and measured muon flux will be discussed.

scintillation detector, petawatt laser-based muon ↗

Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy

Purpose: A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. Methods: Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles, for each of which the dose and the relative biological effectiveness (RBE) were estimated at a tumor depth in the middle of spread-out Bragg peak. Assuming exponential behavior for attenuation and yield of these components with depth, the PE effect on dose was calculated for clinical carbon-ion beams and was partly tested by experiment. The two-component model was integrated into a treatment-planning system and the PE effect was estimated in two clinical cases. Results: The attenuation per range shift by PE was 0.1%–0.3%/cm in dose and 0.2%–0.4%/cm in RBE-weighted dose, depending on energy and range-modulation width. This translates into reduction of RBE-weighted dose by up to 3% in extreme cases. In the treatment-planning study, however, the effect on RBE-weighted dose to tumor was typically within 1% reduction. Conclusions: The extra attenuation of primary carbon ions in PE was partly compensated by increased secondary particles for tumor dose. In practical situations, the PE range compensators would normally cause only marginal errors as compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulations of {sup 3}He ion physical characteristics in a water phantom and evaluation of radiobiological effectiveness

Purpose: {sup 3}He ions may hold great potential for clinical therapy because of both their physical and biological properties. In this study, the authors investigated the physical properties, i.e., the depth-dose curves from primary and secondary particles, and the energy distributions of helium ({sup 3}He) ions. A relative biological effectiveness (RBE) model was applied to assess the biological effectiveness on survival of multiple cell lines. Methods: In light of the lack of experimental measurements and cross sections, the authors used Monte Carlo methods to study the energy deposition of {sup 3}He ions. The transport of {sup 3}He ions in water was simulated by using three Monte Carlo codes—FLUKA, GEANT4, and MCNPX—for incident beams with Gaussian energy distributions with average energies of 527 and 699 MeV and a full width at half maximum of 3.3 MeV in both cases. The RBE of each was evaluated by using the repair-misrepair-fixation model. In all of the simulations with each of the three Monte Carlo codes, the same geometry and primary beam parameters were used. Results: Energy deposition as a function of depth and energy spectra with high resolution was calculated on the central axis of the beam. Secondary proton dose from the primary {sup 3}He beams was predicted quite differently by the three Monte Carlo systems. The predictions differed by as much as a factor of 2. Microdosimetric parameters such as dose mean lineal energy (y{sub D}), frequency mean lineal energy (y{sub F}), and frequency mean specific energy (z{sub F}) were used to characterize the radiation beam quality at four depths of the Bragg curve. Calculated RBE values were close to 1 at the entrance, reached on average 1.8 and 1.6 for prostate and head and neck cancer cell lines at the Bragg peak for both energies, but showed some variations between the different Monte Carlo codes. Conclusions: Although the Monte Carlo codes provided different results in energy deposition and especially in secondary particle production (most of the differences between the three codes were observed close to the Bragg peak, where the energy spectrum broadens), the results in terms of RBE were generally similar.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mesoscale-architecture-based crack evolution dictating cycling stability of advanced lithium ion batteries

The cracking phenomenon of Ni-rich NMC (LiNixMnyCo1-x-yO2, x = 0.6) secondary particles is frequently discovered and believed to be one of critical reasons deteriorating the long-term cycling stability of NMC cathode in lithium ion batteries (LIBs). However, the initiation and evolution of those cracks is still controversial due to the limited quantification especially by in situ monitoring, leading to the challenge of identifying an efficient approach to inhibit the formation of the fractures during repeated cycling. Herein, the irreversible, anisotropic cycling lattice and mesoscale expansion/shrinkage of nano-grain during the first cycle, as revealed by in situ X-ray diffraction (XRD) and in situ atomic force microscopy (AFM), have been quantified and confirmed to be the dominant driving forces of microcracks initiation at the grain boundaries. These microcracks preferentially nucleates at the core region with random oriented nano-grains in early stage. The further growth and aggregation of microcracks into macrocrack eventually results in microfracture propagation radially outward to the periphery region with more uniform nano-grain orientation. This mesoscale nano-grain architecture controlled cracking process highlight the importance of predictive synthesis of cathode materials with controllable multiscale crystalline architecture for high-performance LIBs.

25 ENERGY STORAGE↗

Water and tissue equivalence of a new PRESAGE{sup Registered-Sign} formulation for 3D proton beam dosimetry: A Monte Carlo study

Purpose: To evaluate the water and tissue equivalence of a new PRESAGE{sup Registered-Sign} 3D dosimeter for proton therapy. Methods: The GEANT4 software toolkit was used to calculate and compare total dose delivered by a proton beam with mean energy 62 MeV in a PRESAGE{sup Registered-Sign} dosimeter, water, and soft tissue. The dose delivered by primary protons and secondary particles was calculated. Depth-dose profiles and isodose contours of deposited energy were compared for the materials of interest. Results: The proton beam range was found to be Almost-Equal-To 27 mm for PRESAGE{sup Registered-Sign }, 29.9 mm for soft tissue, and 30.5 mm for water. This can be attributed to the lower collisional stopping power of water compared to soft tissue and PRESAGE{sup Registered-Sign }. The difference between total dose delivered in PRESAGE{sup Registered-Sign} and total dose delivered in water or tissue is less than 2% across the entire water/tissue equivalent range of the proton beam. The largest difference between total dose in PRESAGE{sup Registered-Sign} and total dose in water is 1.4%, while for soft tissue it is 1.8%. In both cases, this occurs at the distal end of the beam. Nevertheless, the authors find that PRESAGE{sup Registered-Sign} dosimeter is overall more tissue-equivalent than water-equivalent before the Bragg peak. After the Bragg peak, the differences in the depth doses are found to be due to differences in primary proton energy deposition; PRESAGE{sup Registered-Sign} and soft tissue stop protons more rapidly than water. The dose delivered by secondary electrons in the PRESAGE{sup Registered-Sign} differs by less than 1% from that in soft tissue and water. The contribution of secondary particles to the total dose is less than 4% for electrons and Almost-Equal-To 1% for protons in all the materials of interest. Conclusions: These results demonstrate that the new PRESAGE{sup Registered-Sign} formula may be considered both a tissue- and water-equivalent 3D dosimeter for a 62 MeV proton beam. The results further suggest that tissue-equivalent thickness may provide better dosimetric and geometric accuracy than water-equivalent thickness for 3D dosimetry of this proton beam.

60 APPLIED LIFE SCIENCES↗

Model-independent indirect detection constraints on hidden sector dark matter

If dark matter inhabits an expanded “hidden sector”, annihilations may proceed through sequential decays or multi-body final states. We map out the potential signals and current constraints on such a framework in indirect searches, using a model-independent setup based on multi-step hierarchical cascade decays. While remaining agnostic to the details of the hidden sector model, our framework captures the generic broadening of the spectrum of secondary particles (photons, neutrinos, e{sup +}e{sup −} and p-barp) relative to the case of direct annihilation to Standard Model particles. We explore how indirect constraints on dark matter annihilation limit the parameter space for such cascade/multi-particle decays. We investigate limits from the cosmic microwave background by Planck, the Fermi measurement of photons from the dwarf galaxies, and positron data from AMS-02. The presence of a hidden sector can change the constraints on the dark matter by up to an order of magnitude in either direction (although the effect can be much smaller). We find that generally the bound from the Fermi dwarfs is most constraining for annihilations to photon-rich final states, while AMS-02 is most constraining for electron and muon final states; however in certain instances the CMB bounds overtake both, due to their approximate independence on the details of the hidden sector cascade. We provide the full set of cascade spectra considered here as publicly available code with examples at http://web.mit.edu/lns/research/CascadeSpectra.html.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of oxidant concentration, exposure time, and seed particles on secondary organic aerosol chemical composition and yield

We performed a systematic intercomparison study of the chemistry and yields of secondary organic aerosol (SOA) generated from OH oxidation of a common set of gas-phase precursors in a Potential Aerosol Mass (PAM) continuous flow reactor and several environmental chambers. In the flow reactor, SOA precursors were oxidized using OH concentrations ranging from 2.0 &times; 10 8 to 2.2 &times; 10 10 molec cm -3 over exposure times of 100 s. In the environmental chambers, precursors were oxidized using OH concentrations ranging from 2 &times; 10 6 to 2 &times; 10 7 molec cm -3 over exposure times of several hours. The OH concentration in the chamber experiments is close to that found in the atmosphere, but the integrated OH exposure in the flow reactor can simulate atmospheric exposure times of multiple days compared to chamber exposure times of only a day or so. In most cases, for a specific SOA type the most-oxidized chamber SOA and the least-oxidized flow reactor SOA have similar mass spectra, oxygen-to-carbon and hydrogen-to-carbon ratios, and carbon oxidation states at integrated OH exposures between approximately 1 × 10 11 and 2 × 10 11 molec cm -3 s, or about 1–2 days of equivalent atmospheric oxidation. This observation suggests that in the range of available OH exposure overlap for the flow reactor and chambers, SOA elemental composition as measured by an aerosol mass spectrometer is similar whether the precursor is exposed to low OH concentrations over long exposure times or high OH concentrations over short exposure times. This similarity in turn suggests that both in the flow reactor and in chambers, SOA chemical composition at low OH exposure is governed primarily by gas-phase OH oxidation of the precursors rather than heterogeneous oxidation of the condensed particles. In general, SOA yields measured in the flow reactor are lower than measured in chambers for the range of equivalent OH exposures that can be measured in both the flow reactor and chambers. The influence of sulfate seed particles on isoprene SOA yield measurements was examined in the flow reactor. The studies show that seed particles increase the yield of SOA produced in flow reactors by a factor of 3 to 5 and may also account in part for higher SOA yields obtained in the chambers, where seed particles are routinely used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle Size Distribution Dynamics Can Help Constrain the Phase State of Secondary Organic Aerosol

Particle phase state is a property of atmospheric aerosols that has important implications for the formation, evolution, and gas/particle partitioning of secondary organic aerosol (SOA). In this work, we use a size-resolved chemistry and microphysics model (SOM-TOMAS), updated to include an explicit treatment of particle phase state, to constrain the bulk diffusion coefficient (Db) of SOA produced from ??- pinene ozonolysis. By leveraging data from laboratory experiments performed in the absence of a seed and under dry conditions, we find that the Db for SOA can be constrained (1-7 ×10-15 cm2 s-1 in these experiments) by simultaneously reproducing the time-varying SOA mass concentrations and the evolution of the particle size distribution. Another version of our model that used the predicted SOA composition to calculate the glass transition temperature, viscosity, and, ultimately, Db (~10-15 cm2 s-1) of the SOA was able to reproduce the mass and size distribution measurements when we included oligomer formation (oligomers accounted for about a fifth of the SOA mass). Our work highlights the potential of a size resolved SOA model to constrain the particle phase state of SOA by utilizing historical measurements of the evolution of the particle size distribution.

He, Yicong↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗