Comparative life-cycle assessments and techno-economic analysis of renewable natural gas production pathways from biogas

Renewable natural gas (RNG) offers a promising pathway for decarbonizing hard-to-abate sectors. This study shows that, relative to conventional upgrading technologies (i.e., membrane separation and pressure swing adsorption), the catalytic methanation reaction (CMR) at water resource recovery facilities doubles RNG output. When consuming lowcarbon hydrogen, the CMR reduces operational energy use and global warming potential. Techno-economic analysis indicates that the CMR is not yet competitive but will become viable if hydrogen reaches $1/kg. Heat integration and hydrogen cost are key drivers of overall performance.

03 NATURAL GAS↗

Vapor-phase self-assembly for generating thermally stable single-atom catalysts

Preparation of thermally stable metal single-atom catalysts (SACs) is a challenge in heterogeneous catalysis, especially on conventional supports that provide a weak metal-support interaction. In this work, we report that a modified support MgAl 2 O 4 can stabilize Pt single atoms by a mechanism of vapor-phase self-assembly in a high-temperature treatment (800°C, air). The experimental results on the formation mechanism and the structure are validated by DFT and ab initio molecular dynamics simulations. We infer that stable triangular K 3 O 3 structures help stabilize Pt single atoms at high temperatures in oxidizing conditions, exhibiting excellent reactivity for methane oxidation. The obtained Pt/K/MgAl 2 O 4 SAC presents excellent stability in methane oxidation after steam treatment at elevated temperatures, whereas the Pt/MgAl 2 O 4 nanocatalyst suffers from rapid deactivation due to Pt nanoparticle growth. Now this work paves the way for preparing thermally stable and highly active SACs using conventional high-surface-area supports, despite the weak metal-support interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing carbon storage through proactively managing fire-prone coniferous mountain forests

Mountain ecosystems typically serve as carbon (C) sinks. However, studies also suggest that they could be C sources due to climate warming, drought and insect-related mortality, wildfires, and management actions. We applied the Lund-Potsdam-Jena General Ecosystem Simulator (LPJ-GUESS), a process-based dynamic vegetation-ecosystem model, to investigate the role of ecosystem management in C storage under Mediterranean climate over the 21 st century. We modified LPJ-GUESS to include implementing mechanical thinning by vegetation size classes, components, and types along with a new mechanistic fire-occurrence model that accounts for wind speed and lightning ignition. Simulations show that mechanical thinning or prescribed fire performed 5-20 years in advance of a high-severity wildfire reduced direct wildfire C emissions by 38-66 %. Our results also show that long-term management actions repeated every 5-20 years, including thinning relatively small trees (diameters up to 7 inches or ∼178 mm), can maintain stable C levels in the forest and lower dead-fuel amounts. We found that, although prescribed fire mitigated wildfire severity, ecosystem C storage from reduced wildfire emissions can be outweighed by the added emissions from the prescribed fire themselves. Thinning plus removing and sequestering the thinned biomass can ensure that forests act as net C sinks through the end of the 21 st century. However, addition of prescribed fire is needed to reduce understory and lower the projected extent of high-severity wildfire. Achieving the competing goals of reducing wildfire and making the Sierra Nevada long-term C sink can be advanced through carefully coordinated thinning, sequestration of thinned biomass, and prescribed fire.

Climate solutions↗

Quantifying the reductions in mortality from air-pollution by cancelling new coal power plants

Deep decarbonization paths to the 1.5°C or 2°C temperature stabilization futures require a rapid reduction in conventional coal-fired power plants, but countries are currently building 223 GW of new coal power capacity and plan to build 377 GW more in the next decade. Coal-fired plants are also a major contributor to air pollution related health impacts. Here, we couple an integrated human-earth system model (GCAM) with an air quality model (TM5-FASST) to examine regional health co-benefits from cancelling new coal-fired plants worldwide. Additionally, we find that cancelling all new proposed projects would decrease air pollution related premature mortality between 101,388 - 213,205 deaths (2-5%) in 2030, and 213,414 - 373,054 (5-8%) in 2050, globally, but heavily concentrated in developing Asia. Furthermore, we estimate that strengthening the climate target from 2°C to 1.5°C would avoid 326,351 additional mortalities in 2030, of which 251,011 (75%) are attributable to the incremental coal plant shutdown.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dilated causal convolutional neural networks for forecasting zone airflow to estimate short-term energy consumption

Here this paper investigates the use of dilated causal convolutional neural networks for fine- grained temporal forecasting of building zone states. Specifically, we build and evaluate models using a small set of exogenous features (e.g., external temperature) to autoregressively predict zone airflow setpoints every minute for a 24-hour prediction window. We carefully explore the trade-off between generality and specificity in these models, training and evaluating them based on zone, zone type, month, season, and combinations thereof. When evaluated for a commercial office building in Eastern Washington with 16 zones served by variable air volume air handling units, we find that the highest performance comes from a zone-specific, season-agnostic approach; with it, we obtain an R 2 of 0.704 (averaged over zones) and an average normalized root mean square error (nRMSE) of 0.111. In contrast, the most general model (trained across all zones and seasons) yields an R 2 of only 0.416 and a nRMSE of 0.168, while a baseline zone-specific reduced order model obtains 0.443 R 2 and 0.159 nRMSE. We also report on factors affecting airflow forecasting performance, on the ability of models trained on a specific zone to generalize to other zones, and on the capability of those models trained on a specific month to generalize to other months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A systematic review of machine learning in groundwater monitoring

With increasing concerns about water scarcity, groundwater has become crucial since this resource provides most of the freshwater needs. However, various human and natural activities often contaminate the groundwater, making it unsuitable for use. Over the years, scientists and engineers have used many methods to predict and track groundwater contamination as part of environmental monitoring. Consequently, there is an urgent need for improved methods, particularly in the face of increasing contamination. Machine learning has sometimes been used to monitor groundwater, air quality, and climate. Traditional methods must be improved due to the complexity and large amount of environmental data. This includes using hybrid models that combine traditional and new techniques. Despite the use of machine learning in many scientific areas, there is a lack of comprehensive reviews focusing on its use in environmental monitoring, especially groundwater monitoring. We aim to fill this gap by exploring machine-learning applications in groundwater monitoring. We discuss relevant methods, their limitations, and future potential. We summarize research on automating data processing and model training using groundwater sensor data. Our research underscores the transformative potential of machine learning to revolutionize long-term groundwater monitoring and contamination detection, providing valuable insights for future research and practical applications.

AI/ML↗

Inter-well connectivity detection in CO 2 WAG projects using statistical recurrent unit models

Routine well-wise injection and production measurements contain significant information on subsurface structure and properties. Data-driven technology that interprets surface data into subsurface structure or properties can assist operators in making informed decisions by providing a better understanding of field assets. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO 2 EOR projects utilizing the water-alternating-gas (WAG) process. SRU is a special type of recurrent neural network (RNN) that allows for better characterization of temporal trends, by learning various statistics of the input at different time scales. In our application, the complete states (injection rate, pressure and cumulative injection) at injectors and pressure states at producers are fed to SRU as the input and the phase rates at producers are treated as the output. Once the SRU is trained and validated, it is then used to assess the connectivity of each injector to any producer using permutation variable importance method, wherein inputs corresponding to an injector are shuffled and the increase in prediction error at a given producer is recorded as the importance (connectivity metric) of the injector to the producer. This method is tested in both synthetic and field-scale cases. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. This significantly improves confidence in our data-driven procedure. The novelty of this work is that it is purely data-driven method and can directly interpret routine surface measurements to intuitive subsurface knowledge. Furthermore, the streamline-based validation procedure provides physics-based backing to the results obtained from data analytics. This study results in a reliable and efficient data analytics framework that is well-suited for large field applications.

42 ENGINEERING↗

Prospective Phase 2 Study of Radiation Therapy Dose and Volume De-escalation for Elective Neck Treatment of Oropharyngeal and Laryngeal Cancer

The required elective nodal dose and volumes for head and neck intensity modulated radiation therapy have largely been extrapolated from conventional radiation therapy fields. In this prospective, dual-center, phase 2 study, we investigated the efficacy and tolerability of reduced elective nodal volume and dose in oropharyngeal and laryngeal squamous cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Process intensification approach to enhancing heat and mass transfer: Radio frequency (RF) assisted drying of paper and board

Conventional multi-cylinder drying of paper and board typically relies on both conductive drying from steam-heated cylinders and convective drying, where heated air flows over the paper web surface. Conduction primarily contributes to heat transfer, while convection is the main driver of mass transfer. However, conventional drying systems are heavily dependent on steam, usually powered by fossil fuels, and are often energy-inefficient with high levels of waste. Additionally, these surface-driven processes result in a lower percentage of energy absorption compared to the energy supplied, leading to significant energy losses. To improve this long-standing process, an experimental system was developed to investigate a process intensification approach involving the integration of Radio Frequency (RF) heating, a volumetric electromagnetic technology, alongside traditional conduction and convection drying methods. This study also emphasizes the use of sensors to continuously monitor key parameters such as moisture content, supply system temperatures, sample temperatures, air flows, and drying rates in real-time. The effect of RF as an auxiliary energy source in localized environments at varying moisture levels was explored to optimize industrial drying systems, quantify potential improvements, and provide insights for future studies. Experimental results from trials combining RF with convection and with the base case alternating conduction-convection drying processes are presented. It is shown that RF is a viable process intensification approach for paper drying improving the drying rate and energy intensity at higher moisture contents. These findings offer valuable insights for process intensification and contribute to the process development, modeling, and simulation of advanced paper drying techniques.

42 ENGINEERING↗