Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A scanning resonator for probing quantum coherent devices

Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and, in the case of circuit quantum electrodynamics (circuit QED), has been used to measure the coherent evolution of multiple different types of qubits. Here, we report on the implementation of a scanning resonator for probing quantum coherent devices. Our scanning setup enables tunable coherent coupling to systems of interest without the need for fabricating on-chip superconducting resonators. We measure the internal quality factor of our resonator sensor in the single-photon regime to be >104 and demonstrate capacitive imaging using our sensor with zeptoFarad sensitivity and micron spatial resolution at milliKelvin temperatures. We then use our setup to characterize the energy spectrum and coherence times of multiple transmon qubits with no on-chip readout circuitry. Our experiments introduce a new tool for using circuit QED to measure existing and proposed qubit platforms.

47 OTHER INSTRUMENTATION↗

Nanoscale imaging of quantum dot dimers using time-resolved super-resolution microscopy combined with scanning electron microscopy

Abstract Time-resolved super-resolution microscopy was used in conjunction with scanning electron microscopy to image individual colloidal CdSe/CdS semiconductor quantum dots (QD) and QD dimers. The photoluminescence (PL) lifetimes, intensities, and structural parameters were acquired with nanometer scale spatial resolution and sub-nanosecond time resolution. The combination of these two techniques was more powerful than either alone, enabling us to resolve the PL properties of individual QDs within QD dimers as they blinked on and off, measure interparticle distances, and identify QDs that may be participating in energy transfer. The localization precision of our optical imaging technique was ∼3 nm, low enough that the emission from individual QDs within the dimers could be spatially resolved. While the majority of QDs within dimers acted as independent emitters, at least one pair of QDs in our study exhibited lifetime and intensity behaviors consistent with resonance energy transfer from a shorter lifetime and lower intensity donor QD to a longer lifetime and higher intensity acceptor QD. For this case, we demonstrate how the combined super-resolution optical imaging and scanning electron microscopy data can be used to characterize the energy transfer rate.

36 MATERIALS SCIENCE↗

Magnetic configuration scans during divertor operation of Wendelstein 7-X

Wendelstein 7-X (W7-X) (Greifswald, Germany) is an advanced stellarator, which uses the modular coil concept to realize a magnetic configuration optimized for fusion-relevant plasma properties. The magnet system of the machine allows a variation of the rotational transform (iota) at the boundary. In the latest W7-X operational phase a dedicated configuration scan has been performed varying the rotational transform between magnetic configurations with iota = 5/4 and iota = 5/5 at the boundary. This paper presents an overview of the experiments and of the main results with respect to confinement and stability. The main observation is an increase of the plasma energy in several intermediate configurations of the scan when the 5/5-islands are close to the plasma boundary but still inside the last-closed-flux-surface. In addition, these configurations showed marked MHD-activity with a crashing behavior related to the 5/5-islands. The corresponding mode amplitude was correlated with the size of the internal 5/5 islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning probe spectroscopy of sulfur vacancies and MoS 2 monolayers in side-contacted van der Waals heterostructures

We investigate the interplay between vertical tunneling and lateral transport phenomena in electrically contacted van der Waals heterostructures made from monolayer MoS 2 , hBN, and graphene. We compare data taken by low-temperature scanning tunneling spectroscopy to results from room-temperature conductive atomic force spectroscopy on monolayer MoS 2 with sulfur vacancies and with varying hBN layers. We show that for thick hBN barrier layers, where tunneling currents into the conductive substrate are suppressed, a side-contact still enables addressing the defect states in the scanning tunneling microscopy via the lateral current flow. Few-layer hBN realizes an intermediate regime in which the competition between vertical tunneling and lateral transport needs to be considered. The latter is relevant for device structures with both a thin tunneling barrier and a side-contact to the semiconducting layers.

36 MATERIALS SCIENCE↗

Determination of rutile transition metal oxide (110) surface terminations by scanning tunneling microscopy contrast reversal

The surfaces of rutile transition-metal oxides (TMO 2 ) are widely investigated for catalysis, photoelectrochemical solar cells, memristors, and supercapacitors, but their structures have remained controversial. Here we employ density functional theory to predict that a universal behavior of metallic TMO 2 surfaces, i.e., the stoichiometric TMO 2 surfaces, exhibit a contrast reversal in simulated scanning tunneling microscopy (STM) images at different scanning biases. The predictions are verified by experimental STM imaging of RuO 2 (110) surfaces and this feature is shown to enable accurate determinations of the TMO 2 (110) surface structures under various conditions. This research provides different insights into the electronic properties of TMO 2 (110) surfaces and offers an effective method to directly map the surface structure and point defects using bias-dependent STM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Exploring Physics of Ferroelectric Domain Walls in Real Time: Deep Learning Enabled Scanning Probe Microscopy

The functionality of ferroelastic domain walls in ferroelectric materials is explored in real-time via the in situ implementation of computer vision algorithms in scanning probe microscopy (SPM) experiment. The robust deep convolutional neural network (DCNN) is implemented based on a deep residual learning framework (Res) and holistically nested edge detection (Hed), and ensembled to minimize the out-of-distribution drift effects. The DCNN is implemented for real-time operations on SPM, converting the data stream into the semantically segmented image of domain walls and the corresponding uncertainty. Further the pre-defined experimental workflows perform piezoresponse spectroscopy measurement on thus discovered domain walls, and alternating high- and low-polarization dynamic (out-of-plane) ferroelastic domain walls in a PbTiO 3 (PTO) thin film and high polarization dynamic (out-of-plane) at short ferroelastic walls (compared with long ferroelastic walls) in a lead zirconate titanate (PZT) thin film is reported. This work establishes the framework for real-time DCNN analysis of data streams in scanning probe and other microscopies and highlights the role of out-of-distribution effects and strategies to ameliorate them in real time analytics.

36 MATERIALS SCIENCE↗

Three-dimensional phenotyping of peach tree-crown architecture utilizing terrestrial laser scanning

Tree training systems for temperate fruit have been developed throughout history by pomologists to improve light interception, fruit yield, and fruit quality. These training systems direct crown and branch growth to specific configurations. Quantifying crown architecture could aid the selection of trees that require less pruning or that naturally excel in specific growing/training system conditions. Regarding peaches [Prunus persica (L.) Batsch], access tools such as branching indices have been developed to characterize tree-crown architecture. However, the required branching data (BD) to develop these indices are difficult to collect. Traditionally, BD have been collected manually, but this process is tedious, time-consuming, and prone to human error. These barriers can be circumnavigated by utilizing terrestrial laser scanning (TLS) to obtain a digital twin of the real tree. TLS generates three-dimensional (3D) point clouds of the tree crown, wherein every point contains 3D coordinates (x, y, z). To facilitate the use of these tools for peach, we selected 16 young peach trees scanned in 2021 and 2022. These 16 trees were then modeled and quantified using the open-source software TreeQSM. As a result, “in silico” branching and biometric data for the young peach trees were calculated to demonstrate the capabilities of TLS phenotyping of peach tree-crown architecture. The comparison and analysis of field measurements (in situ) and in silico BD, biometric data, and quantitative structural model branch uncertainty data were utilized to determine the reconstructive model’s reliability as a source substitute for field measurements. Mean average deviation when comparing young tree (YT) height was approx. 5.93%, with crown volume was approx. 13.26% across both 2021 and 2022. All point clouds of the YTs in 2022 showed residuals lower than 12 mm to cylinders fitted to all branches, and mean surface coverage greater than 40% for both the trunk and primary branching orders.

09 BIOMASS FUELS↗

Tip-Induced 3D Printing on the Nanoscale with Field Emission Scanning Probes

3D printing down to the nanoscale remains a significant challenge. In this paper, the study explores the use of scanning probes that emit low-energy electrons (<100 eV) coupled with the localized injection and electron-induced decomposition of precursor molecules, for the precise localized deposition of 3D nanostructures. The experiments are performed inside the chamber of a scanning electron microscope (SEM), enabling the use of the in-built gas injector system (GIS) with gaseous naphthalene precursor for carbon deposition, as well as immediate inspection of the deposits by SEM. Substrate materials are planar fused silica with thin conductive coatings and non-planar copper wedges. After investigation of the deposition process parameters, various 2D and 3D carbon deposits are grown. Vertical nanowires several microns in length with a diameter <100 nm are achieved and 3D deposits with a high degree of nanoscale branching are also obtained, presumably due to a charging effect. High aspect ratio carbon nanostructures such as those demonstrated here can be employed as miniaturized electrodes or field emitters. The tip-based approach presented thus paves the way toward 3D nanoscale printing of various materials and functional nanostructures.

3D printing↗

A Platform for Atomic Fabrication and In Situ Synthesis in a Scanning Transmission Electron Microscope

Here, the engineering of quantum materials requires the development of tools able to address various synthesis and characterization challenges. These include the establishment and refinement of growth methods, material manipulation, and defect engineering. Atomic-scale modification will be a key enabling factor for engineering quantum materials where desired phenomena are critically determined by atomic structures. Successful use of scanning transmission electron microscopes (STEMs) for atomic scale material manipulation has opened the door for a transformed view of what can be accomplished using electron-beam-based strategies. However, serious obstacles exist on the pathway from possibility to practical reality. One such obstacle is the in situ delivery of atomized material in the STEM to the region of interest for further fabrication processes. Here, progress on this front is presented with a view toward performing synthesis (deposition and growth) processes in a scanning transmission electron microscope in combination with top-down control over the reaction region. An in situ thermal deposition platform is presented, tested, and deposition and growth processes are demonstrated. In particular, it is shown that isolated Sn atoms can be evaporated from a filament and caught on the nearby sample, demonstrating atomized material delivery. This platform is envisioned to facilitate real-time atomic resolution imaging of growth processes and open new pathways toward atomic fabrication.

36 MATERIALS SCIENCE↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping structural heterogeneity at the nanoscale with scanning nano-structure electron microscopy (SNEM)

Here, in this work, we explore the use of scanning electron diffraction (also known as 4D-STEM) coupled with electron atomic pair distribution function analysis (ePDF) to understand the local order (structure and chemistry) as a function of position in a complex multicomponent system, a hot rolled, Ni-encapsulated, Zr 65 Cu 17.5 Ni 10 Al 7.5 bulk metallic glass (BMG), with a spatial resolution of 3 nm. We show that it is possible to gain insight into the chemistry and chemical clustering/ordering tendency in different regions of the sample, including in the vicinity of nano-scale crystallites that are identified from virtual dark field images and in heavily deformed regions at the edge of the BMG. In addition to simpler analysis, unsupervised machine learning was used to extract partial PDFs from the material, modeled as a quasi-binary alloy, and map them in space. These maps allowed key insights not only into the local average composition, as validated by EELS, but also a unique insight into chemical short-range ordering tendencies in different regions of the sample during formation. The experiments are straightforward and rapid and, unlike spectroscopic measurements, don’t require energy filters on the instrument. We spatially map different quantities of interest (QoI’s), defined as scalars that can be computed directly from positions and widths of ePDF peaks or parameters refined from fits to the patterns. We developed a flexible and rapid data reduction and analysis software framework that allows experimenters to rapidly explore images of the sample on the basis of different QoI’s. The power and flexibility of this approach are explored and described in detail. Because of the fact that we are getting spatially resolved images of the nanoscale structure obtained from ePDFs we call this approach scanning nano-structure electron microscopy (SNEM), and we believe that it will be powerful and useful extension of current 4D-STEM methods.

36 MATERIALS SCIENCE↗