Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SQUIDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and Fabrication of a Two-Dimensional Superconducting Bolometer Array

Large format, two dimensional arrays of close-packed bolometers will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory and the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, closepacked bolometer arrays. Both these instruments are imaging Fabry-Perot spectrometers operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this purpose. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs of order 5x10(exp 18) W/square root of Hz. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays.

Benford, Dominic↗

Design and Fabrication of Two-Dimensional Superconducting Bolometer Array for SAFIRE

The Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, close-packed bolometer array. SAFIRE is an imaging Fabry-Perot spectrometer operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this instrument. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs (Noise Equivalent Powers) of order 5x10(exp 18)W/square root of Hz. An architecture which permits 512 pixels to be placed adjacent to each other in an area the size of a postage stamp, integrate them with multiplexers, and provide all the necessary wiring interconnections is a complex proposition, but can be achieved. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. The result is a compact array, easily scalable to kilopixel arrays. Engineering results from the first such detector arrays will be presented.

Benford, Dominic↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Oceans, Ice Shells, and Life on Europa

The four large satellites of Jupiter are famous for their planet-like diversity and complexity, but none more so than ice-covered Europa. Since the provocative Voyager images of Europa in 1979, evidence has been mounting that a vast liquid water ocean may lurk beneath the moon's icy surface. Europa has since been the target of increasing and sometimes reckless speculation regarding the possibility that giant squid and other creatures may be swimming its purported cold, dark ocean. No wonder Europa tops everyone's list for future exploration in the outer solar system (after the very first reconnaissance of Pluto and the Kuiper belt, of course). Europa may be the smallest of the Galilean moons (so-called because they were discovered by Galileo Galilei in the early 17th century) but more than makes up for its diminutive size with a crazed, alien landscape. The surface is covered with ridges hundreds of meters high, domes tens of kilometers across, and large areas of broken and disrupted crust called chaos. Some of the geologic features seen on Europa resemble ice rafts floating in polar seas here on Earth-reinforcing the idea that an ice shell is floating over an ocean on this Moon-size satellite. However, such features do not prove that an ocean exists or ever did. Warm ice is unusually soft and will flow under its own weight. If the ice shell is thick enough, the warm bottom of the shell will flow, as do terrestrial glaciers. This could produce all the observed surface features on Europa through a variety of processes, the most important of which is convection. (Convection is the vertical overturn of a layer due to heating or density differences-think of porridge or sauce boiling on the stove.) Rising blobs from the base of the crust would then create the oval domes dotting Europa's surface. The strongest evidence for a hidden ocean beneath Europa's surface comes from the Galileo spacecraft's onboard magnetometer, which detected fluctuations in Jupiter's magnetic field consistent with a conductor inside Europa. The most likely conductor: a somewhat salty ocean.

Schenk, Paul↗

Antiferromagnetic Interlayer Exchange Coupling in All-Semiconducting EuS/PbS/EuS Trilayers

A comprehensive experimental study on the antiferromagnetic interlayer exchange coupling in high quality epitaxial all-semiconducting EuSPbSEuS trilayers is reported. The influence of substrates, the thickness of the non-magnetic PbS spacer layer, and of temperature, was investigated by means of SQUID magnetometry. In trilayers with a PbS thickness between 4 and 12 deg A the low temperature hysteresis loops showed the signature of antiferromagnetic coupling. The value of the interlayer exchange coupling energy was determined by simulating the data with a modified Stoner model, including Zeeman, anisotropy, and exchange coupling energies. An important observation was of a strong dependence of the interlayer exchange coupling energy on temperature, consistent with a power law dependence of the exchange coupling constant on the saturation magnetization of the EuS layers. While no theoretical description is readily available, we conjecture that the observed behavior is due to a dependence of the interlayer exchange coupling energy on the exchange splitting of the EuS conduction band.

Smits, C. J. P.↗

Investigations of Relatively Easy To Construct Antennas With Efficiency in Receiving Schumann Resonances: Preparations for a Miniaturized Reconfigurable ELF Receiver

Relatively little is known about the cavity between the Earth and the ionosphere, which opens opportunities for technological advances and unique ideas. One effective means to study this cavity is with extremely low frequency (ELF) antennas. Possible applications of these antennas are global weather prediction, earthquake prediction, planetary exploration, communication, wireless transmission of power, or even a free energy source. The superconducting quantum interference device SQUID) and the coil antenna are the two most acceptable receivers discovered for picking up ELF magnetic fields. Both antennas have the potential for size reduction, allowing them to be portable enough for access to space and even for personal ware. With improvements of these antennas and signal processing, insightful analysis of Schumann resonance (SR) can give the science community a band of radio frequency (RF) signals for improving life here on Earth and exploring beyond.

Farmer, Brian W.↗

A Dry-Etch Process for Low Temperature Superconducting Transition Edge Sensors for Far Infrared Bolometer Arrays

The next generation of ultra-low power bolometer arrays, with applications in far infrared imaging, spectroscopy and polarimetry, utilizes a superconducting bilayer as the sensing element to enable SQUID multiplexed readout. Superconducting transition edge sensors (TES s) are being produced with dual metal systems of superconductinghormal bilayers. The transition temperature (Tc) is tuned by altering the relative thickness of the superconductor with respect to the normal layer. We are currently investigating MoAu and MoCu bilayers. We have developed a dry-etching process for MoAu TES s with integrated molybdenum leads, and are working on adapting the process to MoCu. Dry etching has the advantage over wet etching in the MoAu system in that one can achieve a high degree of selectivity, greater than 10, using argon ME, or argon ion milling, for patterning gold on molybdenum. Molybdenum leads are subsequently patterned using fluorine plasma.. The dry-etch technique results in a smooth, featureless TES with sharp sidewalls, no undercutting of the Mo beneath the normal metal, and Mo leads with high critical current. The effects of individual processing parameters on the characteristics of the transition will be reported.

Allen, Christine A.↗

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗

First Astronomical Use of Multiplexed Transition Edge Sensor Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda approx. 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE operates in the 350 m and 450 m bands. These bands cover line emission from the important star formation tracers neutral carbon (CI) and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Staguhn, J. G.↗

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.↗

Glycogen synthase kinase 3 phosphorylates kinesin light chains and negatively regulates kinesin-based motility

Membrane-bounded organelles (MBOs) are delivered to different domains in neurons by fast axonal transport. The importance of kinesin for fast antero grade transport is well established, but mechanisms for regulating kinesin-based motility are largely unknown. In this report, we provide biochemical and in vivo evidence that kinesin light chains (KLCs) interact with and are in vivo substrates for glycogen synthase kinase 3 (GSK3). Active GSK3 inhibited anterograde, but not retrograde, transport in squid axoplasm and reduced the amount of kinesin bound to MBOs. Kinesin microtubule binding and microtubule-stimulated ATPase activities were unaffected by GSK3 phosphorylation of KLCs. Active GSK3 was also localized preferentially to regions known to be sites of membrane delivery. These data suggest that GSK3 can regulate fast anterograde axonal transport and targeting of cargos to specific subcellular domains in neurons.

NASA Discipline Neuroscience↗

A Rapid Turnaround Cryogenic Detector Characterization System

Upcoming major NASA missions such as the Einstein Inflation Probe and the Single Aperture Far-Infrared Observatory require arrays of detectors with thousands of elements, operating at temperatures near l00 mK and sensitive to wavelengths from approx. 100 microns to approx. 3 mm. Such detectors represent a substantial enabling technology for these missions, and must be demonstrated soon in order for them to proceed. In order to make rapid progress on detector development, the cryogenic testing cycle must be made convenient and quick. We have developed a cryogenic detector characterization system capable of testing superconducting detector arrays in formats up to 8 x 32, read out by SQUID multiplexers. The system relies on the cooling of a two-stage adiabatic demagnetization refrigerator immersed in a liquid helium bath. This approach permits a detector to be cooled from 300K to 50 mK in about 4 hours, so that a test cycle begun in the morning will be over by the end of the day. Tine system is modular, with two identical immersible units, so that while one unit is cooling, the second can be reconfigured for the next battery of tests. We describe the design, construction, and performance of this cryogenic detector testing facility.

Benford, Dominic j.↗

Design and Fabrication of a Two-Dimensional Superconducting Pop-up Bolometer Array

We have been developing an architecture for producing large format, two dimensional arrays of close-packed bolometers, which will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The low backgrounds achieved in these instruments require very sensitive detectors with NEPs of order 5 x 10(exp -18) W/square root of Hz. Superconducting transition edge sensor bolometers can be close-packed using the Pop-up Detector (PUD) format, and SQUID multiplexers operating at the detector base temperature can be intimately coupled to them. The array unit cell is 8 x 32 pixels, using 32- element detector and multiplexer components. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays. We report on the production of the 32-element components for the arrays. Planned instruments using this array architecture include the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory, the South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory, the Millimeter Bolometer Camera for the Atacama Cosmology Telescope (MBC/ACT), and the Redshift (Z) Early Universe Spectrometer (ZEUS j.

Benford, Dominic J.↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

Metglas 2714A for Low Temperature Transformer Core and EMI Filter

We have measured the real and imaginary parts of the relative permeability of Metglas 2714A. The magnetization noise density of a toroid made of this material is also measured with a SQUID magnetometer. This noise density is found to agree very well with the fluctuation dissipation theorem, implying that superconducting transformers with predictable noise characteristic can be designed. We also find that the relative permeability is larger than 10,000 at liquid helium temperature and at frequencies from DC to 100 kHz, making it suitable to be used as EMI filter material. Its usage should be similar to that of ferrites, with the exception that it is also effective at low temperatures.

Quach, Hung↗

Measurements of Thermal Conductivity of Superfluid Helium Near its Transition Temperature T(sub lambda) in a 2D Confinement

We report our recent experiments on thermal conductivity measurements of superfluid He-4 near its phase transition in a two-dimensional (2D) confinement under saturated vapor pressure. A 2D confinement is created by 2-mm- and 1-mm-thick glass capillary plates, consisting of densely populated parallel microchannels with cross-sections of 5 x 50 and 1 x 10 microns, correspondingly. A heat current (2 < Q < 400 nW/sq cm) was applied along the channels long direction. High-resolution measurements were provided by DC SQUID-based high-resolution paramagnetic salt thermometers (HRTs) with a nanokelvin resolution. We might find that thermal conductivity of confined helium is finite at the bulk superfluid transition temperature. Our 2D results will be compared with those in a bulk and 1D confinement.

Jerebets, Sergei↗

The Legacy of the Low Temperature Microgravity Physics Facility

The Jet Propulsion Laboratory (JPL) has been building the Low Temperature Microgravity Physics Facility (LTMPF) as a multi-user research facility for the International Space Station. Because of the recent Presidential Exploration Initiative placed on NASA, NASA has informally told JPL to phase out the development of the LTMPF, assuming a suspension of funding at the end of fiscal year 2004. Over the last five years of development of the Facility, a tremendous legacy of both scientific and technical progress has been made, and a significant amount of flight hardware has been built. During these last few months of remaining funding, the LTMPF plans on finishing some remaining development efforts, archiving the hardware (flight and engineering models), software, and capturing the knowledge generated for possible future missions. These possible future missions could include gravitational or relativistic physics experiments (around the Earth or the Moon), charged particle physics experiments away from the Earth, possible other fundamental physics experiments in a Code U-developed free flyer orbiting the Earth, or even gravitational mapping experiments around the Moon or possibly Mars. LTMPF-developed technologies that are likely to have substantial impact on such future missions include SQUID magnetometers and thermometers, ultra-high-performance cryogenics, and high-Q superconducting resonators.

Larson, Melora↗