3D Orthorhombic Elastic Wave Propagation Simulation of SPE Phase-1 Experiments.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
SUMMARY Single‐parent expression (SPE) is defined as gene expression in only one of the two parents. SPE can arise from differential expression between parental alleles, termed non‐presence/absence (non‐PAV) SPE, or from the physical absence of a gene in one parent, termed PAV SPE. We used transcriptome data of diverse Zea mays (maize) inbreds and hybrids, including 401 samples from five different tissues, to test for differences between these types of SPE genes. Although commonly observed, SPE is highly genotype and tissue specific. A positive correlation was observed between the genetic distance of the two inbred parents and the number of SPE genes identified. Regulatory analysis showed that PAV SPE and non‐PAV SPE genes are mainly regulated by cis effects, with a small fraction under trans regulation. Polymorphic transposable element insertions in promoter sequences contributed to the high level of cis regulation for PAV SPE and non‐PAV SPE genes. PAV SPE genes were more frequently expressed in hybrids than non‐PAV SPE genes. The expression of parentally silent alleles in hybrids of non‐PAV SPE genes was relatively rare but occurred in most hybrids. Non‐PAV SPE genes with expression of the silent allele in hybrids are more likely to exhibit above high parent expression level than hybrids that do not express the silent allele, leading to non‐additive expression. This study provides a comprehensive understanding of the nature of non‐PAV SPE and PAV SPE genes and their roles in gene expression complementation in maize hybrids.
Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.
Solar cycle 23 was accompanied by eight very large solar proton events (SPEs) between 2000 and 2005, along with numerous smaller events. The very large SPE in July 2000, which was associated with the well-known 'Bastille Day Solar Storm,' caused very substantial changes in the polar mesosphere and stratosphere. Significant downward transport of the SPE-produced NO(x) from the polar lower mesosphere and upper stratosphere during the Southern Hemisphere winter period resulted in huge enhancements (>100%) in middle stratospheric NO(x) (NO+NO2) during September 2000 in the polar vortex, which were measured by UARS HALOE (C. E. Randall et al., Geophys. Res. Lett., 28,2385-2388,2001). We have used the Whole Atmosphere Community Climate Model (WACCM) to study the longer-term impact of the July 2000 SPE, the third largest SPE period in the past 40 years. This very large SPE provided a wonderful opportunity to study the downward transport of energetic particle precipitation effects in the middle atmosphere. Not surprisingly, the WACCM-simulated polar Northern Hemisphere influences from the July (mid-summer) 2000 SPE were significant for a few months, but the constituent changes were not transported below about 20 hPa. However in the polar Southern Hemisphere (SH) region, the persistent downward transport in the vortex during the months of July-August-September resulted in significant modeled influences for about a year past the SPE. The SH odd nitrogen family, NO(y) (N, NO, NO2, NO3, N2O5, HNO3, HO2NO2, ClONO2, BrONO2), was greatly enhanced by this SPE and these increases were transported to the lower stratosphere. The SPE-enhanced polar NO(y) resulted in long-lasting ozone decreases (from catalytic NO(y) destruction of ozone) and ozone increases (from NO(y) interference in the chlorine and bromine catalytic ozone destruction cycles). These ozone changes resulted in simulated SH polar stratospheric temperature decreases (1-2 K) and increases (1-3 K)..
Abstract Advancing our understanding of dissolved organic matter (DOM) chemistry in aquatic systems necessitates the integration of data streams from multiple analytical platforms. Some measurements require pretreatment with solid phase extraction (SPE), while others are performed directly on whole water samples. Evidence has suggested that SPE will be biased against select DOM fractions, leading to concerns over the ability to establish data linkages across platforms with variable needs for SPE pretreatment, such as those from optical measurements and those that provide high‐resolution molecular information. Here, we directly addressed this concern by assessing the impact of SPE on DOM optical properties through excitation–emission matrices with parallel factor analysis (PARAFAC) for 47 samples across a stream network within a single watershed reflective of variable DOM sources. PARAFAC data was further paired with molecular information obtained by Fourier transform ion cyclotron resonance mass spectrometry (FTICR‐MS). A comparison of PARAFAC models first revealed no systematic qualitative differences in major components between whole water DOM and DOM isolated by SPE (SPE‐DOM); however, quantitative biases against select components were observed. Further linkages with FTICR‐MS data revealed that the molecular fingerprint associated with each PARAFAC component was consistent between the whole water DOM and SPE‐DOM. Our results suggest that bulk scale linkages across these analytical platforms could be inferred irrespective of the observed quantitative biases resulting from SPE for samples within this example watershed. This work represents a key step toward the systematic evaluation of linkages between optical and high‐resolution mass spectrometry datasets in freshwater lotic environments.
The Source Physics Experiment (SPE) consists of a series of chemical explosions at the Nevada National Security Site. The goal of the SPE is to understand and model seismic-wave generation and propagation from these explosions. To achieve this goal, we need an accurate velocity model of the SPE site. A large-N seismic array deployed at the SPE site during one of the chemical explosions (SPE-5) provides great data for this purpose. The array consists of 996 geophones and covers an area of approximately 2 × 2.5 km. In addition to the SPE-5 explosion, the array recorded 53 large weight drops. Using the large-N seismic array recordings, we perform first-arrival analysis and obtain a 2D P-wave velocity model of the SPE site. We image a sharp transition from high-velocity Cretaceous granite to low-velocity Quaternary alluvium. Other geological units such as the Tertiary volcanic rocks and Paleozoic sedimentary rocks are also clearly shown. The results of this work provide important local geological information and will be incorporated into the larger 3D modeling effort of the SPE program to validate the predictive models developed for the site.
Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.
The recent 23-30 January and 7-11 March 2012 solar proton event (SPE) periods were substantial and caused significant impacts on the middle atmosphere. These were the two largest SPE periods of solar cycle 24 so far. The highly energetic solar protons produced considerable ionization of the neutral atmosphere as well as HOx (H, OH, HO2) and NOx (N, NO, NO2). We compute a NOx production of 1.9 and 2.1 Gigamoles due to these SPE periods in January and March 2012, respectively, which places these SPE periods among the 12 largest in the past 50 years. Aura Microwave Limb Sounder (MLS) observations of the peroxy radical, HO2, show significant enhancements of 0.9 ppbv in the northern polar mesosphere as a result of these SPE periods. Both MLS measurements and Goddard Space Flight Center (GSFC) two-dimensional (2D) model predictions indicated middle mesospheric ozone decreases of 20 percent for several days in the northern polar region with maximum depletions 60 percent as a result of the HOx produced in both the January and March 2012 SPE periods. The SCISAT-1 Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE) and the Envisat Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) instruments measured NO and NO2 (NOx), which indicated enhancements of over 20 ppbv in most of the northern polar mesosphere for several days as a result of these SPE periods. The GSFC 2D model was used to predict the medium-term (months) influence and found that the polar Southern Hemisphere middle atmosphere ozone was most affected by these solar events due to the increased downward motion in the fall and early winter. The downward transport moved the SPE-produced NOy to lower altitudes and led to predicted modest destruction of ozone (5-9 percent) in the upper stratosphere days to weeks after the March 2012 event. Total ozone reductions were predicted to be a maximum of 1 percent in 2012 due to these SPEs.
The Comprehensive Nuclear Test-Ban Treaty requires the ability to detect low-yield (less than 150kton) nuclear events. This kind of monitoring can only be done seismically on a regional scale (within 2000km). At this level, it is difficult to distinguish between low-yield nuclear events and non-nuclear events of similar magnitude. In order to confidently identify a nuclear event, a more detailed understanding of nuclear seismic sources is needed. In particular, it is important to know the effects of local geology on the seismic signal. This study focuses on P-wave velocity in heterogeneous granitoid. The Source Physics Experiment (SPE) is currently performing low-yield tests with chemical explosives at the Nevada National Security Site (NNSS). The exact test site was chosen to be in the Climax Stock, a cretaceous granodiorite and quartz-monzonite pluton located in Area 15 of the NNSS. It has been used in the past for the Hard Hat and Pile Driver nuclear tests, which provided legacy data that can be used to simulate wave propagation. The Climax Stock was originally chosen as the site of the SPE partly because of its assumed homogeneity. It has since been discovered that the area of the stock where the SPE tests are being performed contains a perched water table. In addition, the stock is known to contain an extensive network of faults, joints, and fractures, but the exact effect of these structural features on seismic wave velocity is not fully understood. The SPE tests are designed to seismically capture the explosion phenomena from the near- to the far-field transition of the seismic waveform. In the first SPE experiment, 100kg of chemical explosives were set off at a depth of 55m. The blast was recorded with an array of sensors and diagnostics, including accelerometers, geophones, rotational sensors, short-period and broadband seismic sensors, Continuous Reflectometry for Radius vs. Time Experiment, Time of Arrival, Velocity of Detonation, and infrasound sensors. The focus of this study is two-fold: (1) the geophone array that was focused over the SPE shot and (2) a high-resolution seismic profile that was recently acquired at the field site. The geophone array was placed radially around the SPE shot in five directions with 100m spacing and out to a distance of 2 km. The high-resolution profile was about 475m in length with station and shot spacing of 5m using a 7000lb mini-vibe as a source. In both data sets, the first arrivals will be used to develop velocity models. For the geophone array, 1-D P-wave velocity models will be developed to determine an average apparent velocity of the Climax Stock. The high-resolution data will be used to develop a 2-D P-wave velocity model along the seismic profile. This is in an effort to elucidate the water table in more detail and provide additional information on the near-surface structure. These results will be used in the overall modeling effort to fully characterize the test bed and develop a physics-based model to simulate seismic energy from the SPE events.
Two-dimensional (2D) transition metal dichalcogenides (TMDs) such as tungsten diselenide (WSe 2 ) are attractive nanomaterials for quantum information applications due to single-photon emission (SPE) from intrinsic atomic defects. Defect and strain engineering techniques have been developed to produce high purity, deterministically placed SPE in WSe 2 . However, a major challenge in the application of these techniques is the low temperature required to observe defect-bound TMD exciton emission, typically limiting SPE to T < 30 K. SPE at higher temperatures either loses purity or requires integration into complex devices such as optical cavities. Here, 2D heterostructure engineering and molecular functionalization are combined to achieve high purity (>90%) SPE in strained WSe 2 persisting to over T = 90 K. Covalent diazonium functionalization of graphite in layered WSe 2 /graphite heterostructures maintains high purity up to T = 90 K and single-photon source integrity up to T = 115 K. This method preserves the best qualities of SPE from WSe 2 while increasing working temperature to more than three times the typical range. This work demonstrates the versatility of surface functionalization and heterostructure design to synergistically improve the properties of quantum emission and offers new insights into the phenomenon of SPE from 2D materials.
Phase I of the Source Physics Experiment (SPE) series involved six underground chemical explosions, all of which were conducted at the same experimental pad. Research from the sixth explosion of the series (SPE-6) demonstrated that polarimetric synthetic aperture radar (PolSAR) is a viable technology for monitoring an underground chemical explosion when the geologic structure is Cretaceous granitic intrusive. It was shown that a durable signal is measurable by the H/A/α polarimetric decomposition parameters. After the SPE-6 experiment, the SPE program moved to the Phase II location, which is composed of dry alluvium geology (DAG). The loss of wavefront energy is greater through dry alluvium than through granite. In this article, we compare the SPE-6 analysis to the second DAG (DAG-2) experiment. We hypothesize that despite the geology at the DAG site being more challenging than at the Phase I location, combined with the DAG-2 experiment having a 3.37 times deeper scaled depth of burial than the SPE-6, a durable nonprompt signal is still measurable by a PolSAR sensor. We compare the PolSAR time-series measures from videoSAR frames, from the SPE-6 and DAG-2 experiments, with accelerometer data. We show which PolSAR measures are invariant to the two types of geology and which are geology dependent. We compare a coherent change detection (CCD) map from the DAG-2 experiment with the data from a fiber-optic distributed acoustic sensor to show the connection between the spatial extent of coherence loss in CCD maps and spallation caused by the explosion. Finally, we also analyze the spatial extent of the PolSAR measures from both explosions.
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides and the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.
Differences in the seismic coda of neighboring events can be used to investigate source location offsets and medium change with coda wave interferometry (CWI). We employ CWI to infer the known relative location between two chemical explosions in Phase I of the Source Physics Experiment (SPE). The inferred displacement between the first, SPE-1, and second, SPE-2, chemical explosion is between 6 and 18 m, with an expectation of 9.2 m, where the known separation is close to 9.4 m. We also employ CWI to find any velocity perturbation due to damage from SPE-2, by comparing its coda with the collocated third SPE chemical explosion, SPE-3. We find that damage due to SPE-2 must be confined to a spherical region with radius less than 10 m and velocity perturbation less than 25%.
The Source Physics Experiment (SPE) is a multiphase experiment to better understand explosion source physics and thereby improve explosion monitoring. The rst phase (Phase I) examined the explosion source in a hard-rock medium and took place in a granite outcrop called the Climax Stock section of the Nevada National Security Site (NNSS). This series of chemical explosions are called the Wet Granite Geology (WGG) events, but are usually referred to simply as the SPE events (i.e., SPE-1, SPE-2, etc.). Event information for the chemical explosions is given in Table 1. The study of explosion aftershocks can aid in understanding of in-situ stresses and be used as a discriminant for earthquakes [Ford and Walter, 2010]. Sweeney and Harben reported no observed aftershocks for SPE-1 and -2, respectively. They calculated a minimum magnitude of observation based on the noise oor of the seismic array and predicted at least one or two events in the week after the events using the hard-rock aftershock model from Ford and Labak. Possible explanations for the null observation ranged from instrumental - poor seismometer coupling, to physical - the shallow depth of burial was unable to access the deep tectonic stress that causes some explosion aftershocks. We extend the analysis of Sweeney and Harben to the largest of the SPE Phase I chemical explosions, SPE-5, which was approximately a 5 tonne TNT-equivalent shot at 76.5 m depth. This event registered as an M L 2 on the University of Nevada, Reno seismic network and should produce a measurable aftershock sequence.
Risk to astronauts due to ionizing radiation exposure is a primary concern for missions beyond Low Earth Orbit (LEO) and will drive mission architecture requirements, mission timelines, and operational practices. Both galactic cosmic ray (GCR) and solar particle event (SPE) environments pose a risk to astronauts for missions beyond LEO. The GCR environment, which is made up of protons and heavier ions covering a broad energy spectrum, is ever present but varies in intensity with the solar cycle, while SPEs are sporadic events, consisting primarily of protons moving outward through the solar system from the sun. The GCR environment is more penetrating and is more difficult to shield than SPE environments, but lacks the intensity to induce acute effects. Large SPEs are rare, but they could result in a lethal dose, if adequate shielding is not provided. For short missions, radiation risk is dominated by the possibility of a large SPE. Longer missions also require planning for large SPEs; adequate shielding must be provided and operational constraints must allow astronauts to move quickly to shielded locations. The dominant risk for longer missions, however, is GCR exposure, which accumulates over time and can lead to late effects such as cancer. SPE exposure, even low level SPE exposure received in heavily shielded locations, will increase this risk. In addition to GCR and SPE environments, the lunar neutron albedo resulting mainly from the interaction of GCRs with regolith will also contribute to astronaut risk. Full mission exposure assessments were performed for proposed long duration lunar surface mission scenarios. In order to accomplish these assessments, radiation shielding models were developed for a proposed lunar habitat and rover. End-to-End mission exposure assessments were performed by first calculating exposure rates for locations in the habitat, rover, and during extra-vehicular activities (EVA). Subsequently, total mission exposures were evaluated for proposed timelines. A number of computational tools and mathematical models, which have been incorporated into NASA's On-Line Tool for the Assessment of Radiation In Space (OLTARIS), were used for this study. These tools include GCR and SPE environment models, human body models, and the HZETRN space radiation transport code, which is used to calculate the transport of the charged particles and neutrons through shielding materials and human tissue. Mission exposure results, assessed in terms of effective dose, are presented for proposed timelines and recommendations are made for improved astronaut shielding and safer operational practice.