Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Detecting and Analyzing Power System Disturbances in PMU Data with the Open-Source Archive Walker Tool

As the number of Phasor Measurement Units (PMUs) deployed in power systems increases, so do the archives of synchrophasor measurements stored by utilities. Significant value can be extracted from these archives by using them to support studies such as frequency response analysis, small-signal stability analysis, and power plant model validation. To better enable utilities to perform these studies, the open-source Archive Walker tool was developed. This tool examines PMU data for grid disturbances and periods of interest. Once identified, the data can be further analyzed inside Archive Walker or exported to specialty tools. In this paper, the various disturbance detectors available in Archive Walker are described, and its interactions with other openly-available tools are highlighted.

Follum, James D.↗

A Robust Yule-Walker Method for Online Monitoring of Power System Electromechanical Modes of Oscillation

Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.

Follum, James D.↗

Sequence Impedance Modeling of Grid-Forming Converters: Preprint

Grid-forming control of inverter-based resources (IBRs) has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents sequence impedance modeling of grid-forming inverters to evaluate its small-signal stability properties. Droop based grid-forming control with full consideration of the multiloop structure is studied, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Mode Meters Robust to Forced Oscillations using Field-Measured Data

Mode meters are tools used by power system operators to continuously monitor a system's small-signal stability. They do so by estimating the system's electromechanical modes of oscillation. When a system undergoes a forced oscillation, mode meters may become biased because the two types of oscillation cannot be distinguished. Modified mode meter algorithms robust to this bias have been proposed in prior research, but these studies were based primarily on simulated data. In this paper, modified least squares and Yule-Walker mode meter algorithms are evaluated using field-measured data from phasor measurement units (PMUs). Results show that the sensitivities of the least squares algorithm make it impractical for use given the complexities of real-world forced oscillations. However, the modified Yule-Walker algorithm is shown to perform well and has significant potential for practical deployment in mode meter tools.

Follum, James D.↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid-following inverter↗

Renewable Source Controls for Grid Stability

The goal of this study was to evaluate the small signal and transient stability of the Western Electricity Coordinating Council (WECC) under high penetrations of renewable energy, and to identify control technologies that would improve the system performance. The WECC is the regional entity responsible for coordinating and promoting bulk electric system reliability in the Western Interconnection. Transient stability is the ability of the power system to maintain synchronism after a large disturbance while small signal stability is the ability of the power system to maintain synchronism after a small disturbance. Transient stability analysis usually focuses on the relative rotor angle between synchronous machines compared to some stability margin. For this study we employed generator speed relative to system speed as a metric for assessing transient stability. In addition, we evaluated the system transient response using the system frequency nadir, which provides an assessment of the adequacy of the primary frequency control reserves. Small signal stability analysis typically identifies the eigenvalues or modes of the system in response to a disturbance. For this study we developed mode shape maps for the different scenarios. Prony analysis was applied to generator speed after a 1.4 GW, 0.5 second, brake insertion at various locations. Six different WECC base cases were analyzed, including the 2022 light spring case which meets the renewable portfolio standards. Because of the difficulty in identifying the cause and effect relationship in large power system models with different scenarios, several simulations were run on a 7-bus, 5-generator system to isolate the effects of different configurations. Based on the results of the study, for a large power system like the WECC, incorporating frequency droop into wind/solar systems provides a larger benefit to system transient response than replacing the lost inertia with synthetic inertia. From a small signal stability perspective, the increase in renewable penetration results in subtle changes to the system modes. In general, mode frequencies increase slightly, and mode shapes remain similar. The system frequency nadir for the 2022 light spring case was slightly lower than the other cases, largely because of the reduced system inertia. However, the nadir is still well above the minimum load shedding frequency of 59.5 Hz. Finally, several discrepancies were identified between actual and reported wind penetration, and additional work on wind/solar modeling is required to increase the fidelity of the WECC models.

power system stability↗

Low jitter RF distribution system

A timing signal distribution system includes an optical frequency stabilized laser signal amplitude modulated at an rf frequency. A transmitter box transmits a first portion of the laser signal and receive a modified optical signal, and outputs a second portion of the laser signal and a portion of the modified optical signal. A first optical fiber carries the first laser signal portion and the modified optical signal, and a second optical fiber carries the second portion of the laser signal and the returned modified optical signal. A receiver box receives the first laser signal portion, shifts the frequency of the first laser signal portion outputs the modified optical signal, and outputs an electrical signal on the basis of the laser signal. A detector at the end of the second optical fiber outputs a signal based on the modified optical signal. An optical delay sensing circuit outputs a data signal based on the detected modified optical signal. An rf phase detect and correct signal circuit outputs a signal corresponding to a phase stabilized rf signal based on the data signal and the frequency received from the receiver box.

47 OTHER INSTRUMENTATION↗

Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same

The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.

Logan, Ronald T.↗

Blending Gyro Signals To Improve Control Stability

Interference by structural vibrations reduced by adding signals from spatially separated gyros. Technique involves blending signals from rate gyroscopes located at different parts of structure to obtain composite signal that more nearly represents rotation of entire structure. Aircraft vibrations perpendicular to pitch axis contribute to rotations sensed by pitch-rate gyros. Proper blending of signals from gyros suppress contribution of dominant vibrational mode. Most likely applications of concept are flight-control systems for aircraft.

J. F. L. Lee↗

Phase shift keyed, pulse code modulated signal synchronizer

Signal is demodulated and synchronized by three loop circuits: ''Q'' loop uses quadrature signal to stabilize frequency; ''B'' loop acts on baseboard signal to stabilize phase; and decoding ''I'' loop acts on in-phase signal. Synchronizer may be used to eliminate false-lock.

Kobayashi, H. S.↗

The Impact of Market Clearing Time and Price Signal Delay on the Stability of Electric Power Markets

We generalize a model, proposed by Alvarado, of the electric power market by including the effects of control and communication. To simulate realistic markets, our model issues control signals only at given times and those signals are delayed during transmission. These two effects transform Alvarado's continuous system into a hybrid system, with consequential effects. The stability analysis of the new system reveals two important properties. First, there is an upper limit on the market clearing time and the delay of the price signal beyond which the system becomes unstable. Second, there is a counter-intuitive relationship between the market clearing time and price signal delay: when the market clearing time is relatively long, delaying the price signal can improve the market's stability while reducing the communication delay can destabilize the market. This counter-intuitive effect shows that the full impact of information technology on power markets can be significant and difficult to anticipate. Therefore, as markets are designed and regulated, careful attention should be paid to the effects of information technology on the market's dynamic behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Temperature-Stabilized Phase Detector

Precise temperature stabilized phase detector for clock signal distribution maintains 100-MHz signal with stability of 5 parts in 10 to the 16th power even for step changes of 20 degrees C in ambient temperature. Stabilization achieved by heating unit to 45 degrees C and maintaining temperature through bridge circuit.

Yeeman, L.↗