Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Real-Time Signal-to-Noise Ratio Estimation by Universal Grid Analyzer

This paper presents a real-time Signal-to-Noise Ratio (SNR) estimation performed by the distribution level phasor measurement unit, Universal Grid Analyzer (UGA). The hardware and software architectures of the UGA are discussed followed by the introduction of SNR estimation algorithm. To verify the effectiveness of both SNR estimation algorithm and its implementation, a real world test bench is set up in the laboratory. The experimental results validate the implementation of the existing SNR algorithm which has maximum of 5 dB error in real-time measurement.

Bhandari, Apsana↗

Signal-to-noise Ratio and Combiner Weight Estimation for Symbol Stream Combining

A method is presented for signal to noise ratio (SNR) and symbol stream combiner weight estimation. The SNR estimator employs absolute value moments as in an earlier method. The main contribution is that a new algorithm is derived for the combiner weight estimator to remove the large bias at low SNRs. The new algorithm is simulated to combine two independent symbol streams at various SNRs. As an example, the combining two symbol streams at SNRs of -1 dB and -7 dB, conbiner weight estimates using 1000 samples for the -1 dB stream and 10,000 samples for the -7 dB stream achieve an output SNR of -0.039 dB, which is just 0.012 dB below the theoretical limit achievable with perfect knowledge of the SNRs.

Vo, Q. D.↗

Advanced study of video signal processing in low signal to noise environments

Conventional analytical techniques used to determine and optimize phase-lock loop (PLL) characteristics are most often based on a model which is valid only if the intermediate frequency (IF) filter bandwidth is large compared to the PLL bandwidth and the phase error is small. An improved model (called the quasi-linear model) is developed which takes into account small IF filter bandwidths and nonlinear effects associated with large phase errors. By comparison of theoretical and experimental results it is demonstrated that the quasi-linear model accurately predicts PLL characteristics. This is true even for small IF filter bandwidths and large phase errors where the conventional model is invalid. The theoretical and experimental results are used to draw conclusions concerning threshold, multiplier output variance, phase error variance, output signal-to-noise ratio, and signal distortion. The relationship between these characteristics and IF filter bandwidth, modulating signal spectrum, and rms deviation is also determined.

Carden, F.↗

Signal-to-noise and radiation exposure considerations in conventional and diffraction x-ray microscopy

Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution images using fewer photons. As a result, this can be an important advantage for studying radiation-sensitive biological and soft matter specimens.

36 MATERIALS SCIENCE↗

Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry

Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl{sub 4} and CHCl{sub 3} were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intermediate-mass-ratio inspirals in the Einstein Telescope. I. Signal-to-noise ratio calculations

The Einstein Telescope (ET) is a proposed third-generation ground-based interferometric gravitational wave detector, for which the target is a sensitivity that is a factor of 10 better than Advanced LIGO and a frequency range that extends down to {approx}1 Hz. Such a third-generation interferometer will provide opportunities to test Einstein's theory of relativity in the strong field and will realize precision gravitational wave astronomy with a thousandfold increase in the expected number of events over the advanced ground-based detectors. A design study for ET is currently underway, so it is timely to assess the science that could be done with such an instrument. This paper is the first in a series that will carry out a detailed study of intermediate-mass-ratio inspirals (IMRIs) for ET. In the context of ET, an IMRI is the inspiral of a neutron star or stellar-mass black hole into an intermediate mass black hole (IMBH). In this paper we focus on the development of IMRI waveform models for circular and equatorial inspirals. We consider two approximations for the waveforms, which both incorporate the inspiral, merger, and ringdown phases in a consistent way. One approximation, valid for IMBHs of arbitrary spin, uses the transition model of Ori and Thorne [A. Ori and K. S. Thorne, Phys. Rev. D 62, 124022 (2000).] to describe the merger, and this is then matched smoothly onto a ringdown waveform. The second approximation uses the effective one body approach to model the merger phase of the waveform and is valid for nonspinning IMBHs. In this paper, we use both waveform models to compute signal-to-noise ratios for IMRI sources detectable by ET. At a redshift of z=1, we find typical signal-to-noise ratios for IMRI systems with masses 1.4M{sub {center_dot}}+100M{sub {center_dot}}, 10M{sub {center_dot}}+100M{sub {center_dot}}, 1.4M{sub {center_dot}}+500M{sub {center_dot}} and 10M{sub {center_dot}}+500M{sub {center_dot}} of {approx}10-25, {approx}40-80, {approx}3-15, and {approx}10-60, respectively. We also find that the two models make predictions for nonspinning inspirals that are consistent to about 10%.

79 ASTRONOMY AND ASTROPHYSICS↗

Signal to noise measurement circuit

Phase lock reference provides a rapid and accurate method of determining the signal-to-noise ratio at the intermediate frequency stage of a receiver.

Deerkoski, L. F.↗

Focal overlap gating in velocity map imaging to achieve high signal-to-noise ratio in photo-ion pump-probe experiments

We demonstrate a technique in velocity map imaging (VMI) that allows spatial gating of the laser focal overlap region in time resolved pump-probe experiments. This significantly enhances signal-to-noise ratio by eliminating background signal arising outside the region of spatial overlap of pump and probe beams. This enhancement is achieved by tilting the laser beams with respect to the surface of the VMI electrodes which creates a gradient in flight time for particles born at different points along the beam. By suitably pulsing our microchannel plate detector, we can select particles born only where the laser beams overlap. Furthermore, this spatial gating in velocity map imaging can benefit nearly all photo-ion pump-probe VMI experiments especially when extreme-ultraviolet light or X-rays are involved which produce large background signals on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal to Noise Analysis of iRadar sensors

This document follows my process of testing; comparing; and contrasting several iRadars signal to noise ratios for both HH and VV polarization. A brief introduction is given explaining the basics of iRadar technology and what data I was collecting. The process section explains the steps I took to collect my data along with any procedures I followed. The analysis section compares and contrasts five different radars and the two different polarizations. The analysis also details the radars viewing limitations and area. Finally, the report delves into the effects of two radars interfering with each other. A conclusion goes over the success and findings of the project.

42 ENGINEERING↗

The flat fielding and achievable signal-to-noise of the MAMA detectors

The Space Telescope Imaging Spectrograph (STIS) was designed to achieve a signal-to-noise (S/N) of at least 100:1 per resolution element. Multi-Anode Microchannel Arrays (MAMA) observations during Servicing Mission Orbital Verification (SMOV) confirm that this specification can be met. From analysis of a single spectrum of GD153, with counting statistics of approximately 165 a S/N of approximately 125 is achieved per spectral resolution element in the far ultraviolet (FUV) over the spectral range of 1280A to 1455A. Co-adding spectra of GRW+7OD5824 to increase the counting statistics to approximately 300 yields a S/N of approximately 190 per spectral resolution element over the region extending from 1347A to 1480A in the FUV. In the near ultraviolet (NUV), a single spectrum of GRW+7OD5824 with counting statistics of approximately 200 yields a S/N of approximately 150 per spectral resolution element over the spectral region extending from 2167 to 2520A. Details of the flat field construction, the spectral extraction, and the definition of a spectral resolution element will be described in the text.

Kaiser, Mary Elizabeth↗

Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies

Background: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. Methods: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. Results: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. Conclusion: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrinsic low pass filtering improves signal-to-noise ratio in critical-point flexure biosensors

A flexure biosensor consists of a suspended beam and a fixed bottom electrode. The adsorption of the target biomolecules on the beam changes its stiffness and results in change of beam's deflection. It is now well established that the sensitivity of sensor is maximized close to the pull-in instability point, where effective stiffness of the beam vanishes. The question: “Do the signal-to-noise ratio (SNR) and the limit-of-detection (LOD) also improve close to the instability point?”, however remains unanswered. In this article, we systematically analyze the noise response to evaluate SNR and establish LOD of critical-point flexure sensors. We find that a flexure sensor acts like an effective low pass filter close to the instability point due to its relatively small resonance frequency, and rejects high frequency noise, leading to improved SNR and LOD. We believe that our conclusions should establish the uniqueness and the technological relevance of critical-point biosensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of signal-to-noise ratio in the in vivo{sup 31}P magnetic resonance spectra of the human brain

The main problem in {sup 31}P magnetic resonance spectroscopy is a low signal-to-noise ratio (SNR) of spectra acquired with clinical magnetic resonance imaging (MRI) scanners. Using spin-spin phosphorus-proton ({sup 31}P-{sup 1}H) decoupling and heteronuclear Overhauser effect and taking into account the effect of the longitudinal relaxation time T{sub 1} on the SNR, the method for localization and excitation of the region of interest (Image Selected in vivo Spectroscopy pulse sequence) was optimized to increase the SNR in the {sup 31}P magnetic resonance spectra of the human brain to ~50% without increasing signal acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗