Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHAPE MEMORY EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Volatile organic compound emissions from 4D printing: Effects of material composition and external stimulus

4D printing of stimuli-responsive materials extends 3D printing by enabling the fabricated structures to transform their shapes and properties over time in response to external stimuli. Numerous research efforts have been dedicated to developing new smart materials, enhancing material printability, and ensuring time-evolving properties. Meanwhile, the use of smart materials and external stimuli in 4D printing has introduced the possibility of air emissions that can potentially deteriorate the indoor air quality at the workplace and pose continuous health hazards to users during the production and use phases. These potential air emissions caused by 4D printing have not yet been assessed in current literature, leading to unknown occupational hazards and human health effects. This study focuses on stereolithography-based 4D printing with constrained thermo-mechanics and builds an emission model to quantify the volatile organic compound emissions from printing, shape programming, and shape recovery stages. The established model mathematically links the emission characteristics with material compositional design and stimuli-response mechanisms. Additionally, shape fixity and recovery abilities are considered to analyze the trade-off between the air emissions and stimuli-response performance of 4D printed parts. Case study results suggest that the methacrylate-based thermo-responsive material with higher glass transition temperature leads to higher air emissions, surpassing the permissible exposure level in the indoor environment. By altering the thermo-temporal conditions, a 61.29% reduction in emission yield can be achieved while ensuring a satisfactory shape memory performance.

36 MATERIALS SCIENCE↗

Effects of deposition and annealing conditions on the crystallisation of NiTi thin films by e-beam evaporation

This Letter demonstrates the effects of deposition and annealing conditions on the crystallisation of nickel–titanium (NiTi) thin films deposited by the e-beam evaporation. NiTi thin films of 0.5 μm thick are fabricated on P-type (110) silicon substrates using the e-beam evaporation technique. We find that with the characterisations using the X-ray diffraction method, the results indicate that low e-beam deposition rate and argon employed annealing procedures can be beneficial to the formation of NiTi crystalline structure. Additionally, the as-deposited NiTi thin films without annealing procedures are amorphous, when deposited on the substrates at low temperatures. The differential scanning calorimetry studies show NiTi thin films formed by the e-beam evaporation are Ni-rich. Furthermore, SEM images illustrate that high-precision patterned NiTi thin film microstructures can be fabricated by combining with the e-beam evaporation and lift-off resist methods, without any wet or dry etching procedures. The proposed fabrication process for NiTi thin film microstructures shows great potential for application in shape memory alloy medical devices, as well as the micro-robotics.

36 MATERIALS SCIENCE↗

NMR study of Ni 50+x ⁢Ti 50-x strain glasses

Here, we studied Ni 50+x ⁢Ti 50-x with compositions up to x = 2, performing 47 Ti and 49 Ti nuclear magnetic resonance (NMR) measurements from 4 to 400 K. For large x in this system, a strain glass appears in which frozen ferroelastic nanodomains replace the displacive martensite structural transition. Here, we demonstrate that NMR can provide an extremely effective probe of the strain-glass freezing process, with large changes in NMR line shape due to the effects of random strains which become motionally narrowed at high temperatures. At the same time with high-resolution x-ray diffraction we confirm the lack of structural changes in x ≥ 1.2 samples, while we show that there is little change in the electronic behavior across the strain-glass freezing temperature. NMR spin-lattice relaxation time (T 1 ) measurements provide a further measure of the dynamics of the freezing process, and indicate a predominantly thermally activated behavior both above and below the strain-glass freezing temperature. We show that the strain-glass results are consistent with a very small density of critically divergent domains undergoing a Vogel-Fulcher-type freezing process, coexisting with domains exhibiting faster dynamics and stronger pinning.

36 MATERIALS SCIENCE↗

Anisotropy induced large exchange bias behavior in ball milled Ni-Co-Mn-Sb alloys

We report the effect of decrease in the grain size on the structural, magnetic and exchange bias (EB) behavior in ball milled Ni{sub 50-x}Co{sub x}Mn{sub 38}Sb{sub 12} (x=0 and 5) Heusler alloys. The existence of a wide range of grain sizes in the ball milled samples results in dramatic changes in the structural and magnetic properties. For x=0, a large EB field of 3.2 kOe is observed in the ball milled sample, compared to a value of 245 Oe of the bulk sample. This increase is attributed to the enhanced exchange coupling between the soft and hard magnetic particles.

36 MATERIALS SCIENCE↗

Clinical Application of a New Indwelling Catheter with a Side-Hole and Spirally Arranged Shape-Memory Alloy for Hepatic Arterial Infusion Chemotherapy

A new indwelling catheter, G-spiral (GSP), was developed for hepatic arterial infusion chemotherapy (HAIC) by way of an implanted catheter-port system (CPS). Here we evaluated its physical properties and the outcomes of its clinical use. The GSP vessel-fixing power and its ability to follow a guidewire were determined with a vascular in vitro model, and Student t test was used to determine statistical significance (P < 0.05). A retrospective analysis was performed to evaluate the technical success rate and to identify the clinical complications associated with radiologic CPS implantation with GSP in 65 patients with unresectable hepatic tumors. The mean vessel-fixing power of the GSP (14.4 g) significantly differed from that of a GSP with a cut shape-memory alloy (3.3 g). The mean resistance to following the guidewire displayed by the GSP (88.5 g) was significantly less than that for a 5F W-spiral (106.3 g) or 4F Cobra-type angiographic catheter (117.8 g). The CPS was placed successfully in 64 of 65 cases (98.5%). Hepatic artery occlusion was observed in one case. Occlusion, cracking, and infection of CPS were observed in one, two, and one case, respectively. The GSP is a highly useful indwelling catheter that can be used for HAIC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic and Transport Properties of Mn{sub 2}Ni{sub 1.8}In{sub 0.2} Alloy

The structural, magnetic, and transport properties of the Mn{sub 2}Ni{sub 1.8}In{sub 0.2} alloy have been presented. It was observed to form in tetragonal structure. Multiple magnetic phase transitions have been detected in magnetization data over the temperature range from 2 to 350 K. From the resistivity, ac susceptibility, and heat capacity data, the superconducting transition are observed at T = 5.6 K. The alloy is considered to be one of the potential candidates from the Mn-rich alloys, which has shown both magnetic and superconducting properties, which can be useful from application point of view.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Damping of Lightweight TiNi-Ti{sub 2}Ni Shape Memory Composites for Wide Temperature Range Usage

A bimodal porous TiNi-Ti{sub 2}Ni shape memory alloy composite (SMAC) with 59% porosity was fabricated by sintering Ti-46at.%Ni elemental powders with pore-forming agent. The porous TiNi-Ti{sub 2}Ni SMAC contains two irregular pores of about 400 and 120 μm. We investigated the microstructure and pore morphology correlated with the mechanical properties and damping capacities of the SMAC. Ti{sub 2}Ni intermetallic phases with size of 1-3 μm were homogeneously distributed in the TiNi matrix. The porous TiNi-Ti{sub 2}Ni SMAC exhibits exceptionally high inverse mechanical quality factor (Q{sup −1}) of ~0.25 at < 40 °C, which is among the highest value reported for porous/dense shape memory alloys or composites to best of our knowledge, and it shows very high compressive fracture strain of about 25%. Moreover, the fabricated porous SMAC at relatively low strain amplitude can exhibit considerable high Q{sup −1} of 0.06 ~ 0.11 for a wide range of temperature between − 90 and 200 °C, which is attributed to the stress concentration distribution provided by the bimodal structure of pores and the massive interfaces between pore/matrix and TiNi/Ti{sub 2}Ni. These porous SMACs can be an ideal candidate for using as a lightweight damping material in the energy-saving applications.

36 MATERIALS SCIENCE↗

Atomic Layer-Deposited TiO{sub 2} Coatings on NiTi Surface

NiTi shape-memory alloys may release poisonous Ni ions at the alloys’ surface. In an attempt to prepare a well-performing surface layer on an NiTi sample, the thermally grown TiO{sub 2} layer, which formed during the heat treatment of NiTi, was removed and replaced with a new TiO{sub 2} layer prepared using the atomic layer deposition (ALD) method. Using x-ray photoelectron spectroscopy, it was found that the ALD layer prepared at as low a temperature as 100 °C contained Ti in oxidation states + 4 and + 3. As for static corrosion properties of the ALD-coated NiTi samples, they further improved compared to those covered by thermally grown oxide. The corrosion rate of samples with thermally grown oxide was 1.05 × 10{sup −5} mm/year, whereas the corrosion rate of the ALD-coated samples turned out to be about five times lower. However, cracking of the ALD coating occurred at about 1.5% strain during the superelastic mechanical loading in tension taking place via the propagation of a localized martensite band.

36 MATERIALS SCIENCE↗

Compressive Deformation Behavior of Open-Cell Cu-Zn-Al Alloy Foam Made Through P/M Route Using Mechanically Alloyed Powder

Cu-Zn-Al foams of varying porosity fractions using mechanical alloyed powder have been made through powder metallurgy route. Here, NH{sub 4} (HCO{sub 3}) was used as a space holder. Mechanically alloyed Cu-Zn-Al is made using a planetary ball mill taking the ratio of Cu/Zn/Al = 70:25:5 (by weight ratio). The ball/powder ratios were varied in the four ranges 10:1, 15:1, 20:1, and 25:1. Green compacts of milled powder and space holder samples were sintered at three stages at three different temperatures 350, 550, and 850 °C for 1 h at each stage. The crystalline size and particle size as a function of ball/powder ratios were examined. The compressive deformation responses of foams are varied with relative density and the ball/powder ratio. The plateau stress and energy absorption of these foams increase with an increase in relative density but decreases with increase in ball/powder ratio, even though crystalline size decreases. This has further been explained on the basis of particle morphology as a function of ball/powder ratio.

36 MATERIALS SCIENCE↗

Microstructures, Martensitic Transformation, and Mechanical Behavior of Rapidly Solidified Ti-Ni-Hf and Ti-Ni-Si Shape Memory Alloys

In this work, the microstructure and mechanical properties of rapidly solidified Ti{sub 50−x/2}Ni{sub 50−x/2}Hf{sub x} (x = 0, 2, 4, 6, 8, 10, and 12 at.%) and Ti{sub 50−y/2}Ni{sub 50−y/2}Si{sub y} (y = 1, 2, 3, 5, 7, and 10 at.%) shape memory alloys (SMAs) were investigated. The sequence of the phase formation and transformations in dependence on the chemical composition is established. Rapidly solidified Ti-Ni-Hf or Ti-Ni-Si SMAs are found to show relatively high yield strength and large ductility for specific Hf or Si concentrations, which is due to the gradual disappearance of the phase transformation from austenite to twinned martensite and the predominance of the phase transformation from twinned martensite to detwinned martensite during deformation as well as to the refinement of dendrites and the precipitation of brittle intermetallic compounds.

36 MATERIALS SCIENCE↗

Fabrication and Properties of Composite Artificial Muscles Based on Nylon and a Shape Memory Alloy

This paper focuses on the design, fabrication and investigation of the mechanical properties of new artificial muscles formed by twisting and annealing. The artificial muscles designed by twisting nylon have become a popular topic in the field of smart materials due to their high mechanical performance with a large deformation and power density. However, the complexity of the heating and cooling system required to control the nylon muscle is a disadvantage, so we have proposed a composite artificial muscle for providing a direct electricity-driven actuation by integrating nylon and a shape memory alloy (SMA). In this paper, the design and fabrication process of these composite artificial muscles are introduced before their mechanical properties, which include the deformation, stiffness, load and response, are investigated. The results show that these composite artificial muscles that integrate nylon and a SMA provide better mechanical properties and yield up to a 44.1% deformation and 3.43 N driving forces. The good performance and direct electro-thermal actuation make these composite muscles ideal for driving robots in a method similar to human muscles.

36 MATERIALS SCIENCE↗

Experimental Validation of Numerical Simulations of a New-Generation NiTi Endodontic File Under Bending

The superelasticity of NiTi shape memory alloy has been used in endodontics since the 1990s. To study the mechanical behavior of endodontic instruments, a traditional approach consists in experimental investigations. However, finite element analysis constitutes another way to assess their mechanical behavior and to facilitate their design. The main aim of this study is to compare experimental and numerical bending results on different structures (NiTi wire, spreader, and instruments) to estimate the reliability of the finite element simulations. These investigations were carried out as follows. Firstly, experimental material parameters identification was performed using NiTi wires. These parameters were implemented in an appropriate NiTi model. Bending was numerically applied to the meshed structures generated by the finite element method. Experimental tests were performed on real structures under bending, with exactly the same loading, in order to compare experimental and numerical results. These results were in good agreement for each of the considered structures. This enabled the validation of the simulation results and the use of simulations to design new endodontic instruments.

36 MATERIALS SCIENCE↗

Stability of Phase Transformation Temperatures During Cycling of Ti-15.8Nb-4.94Al-0.06Sc Shape Memory Alloy

The active ω phase formation decreases the martensitic transformation temperatures sharply and can even suppress the martensitic transformation during thermal cycling in Ti-Nb-based alloys. No ω phase is observed in the present Ti-15.8Nb-4.94Al-0.06Sc alloy when it is annealed at 650 °C for 4 h or subsequently aged at 200 and 250 °C for 2 h. The exclusion of ω phase remarkably improves the stability of phase transformation temperatures during thermal cycling. The martensitic transformation start temperature of the present alloy decreases by 30 °C but tends to be stable gradually during the 20 thermal cycles, owing to the saturation of lattice defects.

36 MATERIALS SCIENCE↗

Superelasticity by reversible variant reorientation in a Ni-Mn-Ga microwire with bamboo grains

The link between microstructure and mechanical properties is investigated for a superelastic Ni–Mn–Ga microwire with 226 μm diameter, created by solidification via the Taylor method. The wire, which consists of bamboo grains with tetragonal martensite matrix and coarse γ precipitates, exhibits fully reversible superelastic behavior up to 4% tensile strain. Upon multiple tensile load–unload cycles, reproducible stress fluctuations of ~3 MPa are measured on the loading superelastic stress plateau of ~50 MPa. During cycles at various temperatures spanning -70 to 55 °C, the plateau stress decreases from 58 to 48 MPa near linearly with increasing temperature. Based on in situ synchrotron X-ray diffraction measurements, we conclude that this superelastic behavior is due to reversible martensite variants reorientation (i.e., reversible twinning) with lattice rotation of ~13°. The reproducible stress plateau fluctuations are assigned to reversible twinning at well-defined locations along the wire. The strain recovery during unloading is attributed to reverse twinning, driven by the internal stress generated on loading between the elastic γ precipitates and the twinning martensite matrix. Lastly, the temperature dependence of the twining stress on loading is related to the change in tetragonality of the martensite, as measured by X-ray diffraction.

36 MATERIALS SCIENCE↗

Acoustic emission analysis of cyclically loaded superelastic shape memory alloy fiber reinforced mortar beams

Superelastic shape memory alloys (SMAs) are metallic alloys that can recover their nonlinear deformations upon unloading. The use of SMAs in cementitious composites as fibers can enable crack recovery and re-centering capabilities. In this study, the crack recovery characteristics of SMA fiber reinforced mortar specimens subjected to flexural cyclic loading are studied through acoustic emission analysis. SMA fiber reinforced mortar specimens with fiber volume ratios of 0.3%, 0.5% and 1.0% are tested under cyclic flexural loads. Acoustic emissions (AE) signals are captured and analyzed to characterize the crack formation and crack width development at each cycle of loading. In addition, the crack width propagation of the specimens is monitored by Digital Image Correlation measurement system and is used as a basis in AE analyses. Results show that the SMA fiber reinforced mortars exhibit considerable re-centering and crack recovery characteristics at large deformation amplitudes.

36 MATERIALS SCIENCE↗

Use of time history speckle pattern and pulsed photoacoustic techniques to detect the self-accommodating transformation in a Cu-Al-Ni shape memory alloy

Continuous and pulsed electromagnetic radiation was used to detect the self-accommodation mechanism on a polycrystalline Cu-13.83 wt.%Al-2.34 wt.%Ni shape memory alloy. Rectangular samples of this alloy were mechanically polished to observe the austenite and martensite phases. The samples were cooled in liquid nitrogen prior to the experiments to obtain the martensite phase. Using a dynamic speckle technique with a continuous wave laser we obtained the time history of the speckle pattern image and monitored the surface changes caused by the self-accommodation mechanism during the inverse (martensitic to austenitic) transformation. Using a photoacoustic technique based on a pulsed laser source it was also possible to detect the self-accommodation phenomena in a bulk sample. For comparison purposes, we used differential scanning calorimetry (DSC) to detect the critical temperatures of transformation and use these as reference to evaluate the performance of the optical and photoacoustical techniques. In all cases, the same range of temperature was obtained during the inverse transformation. From these results, we conclude that time history speckle pattern (THSP) and pulsed photoacoustic are complementary techniques; they are non-destructive and useful to detect surface and bulk martensitic transformation induced by a temperature change.

36 MATERIALS SCIENCE↗

Simultaneous probing of phase transformations in Ni-Ti thin film shape memory alloy by synchrotron radiation-based X-ray diffraction and electrical resistivity

Nickel–Titanium (Ni–Ti) thin film shape memory alloys (SMAs) have been widely projected as novel materials which can be utilized in microdevices. Characterization of their physical properties and its correlation with phase transformations has been a challenging issue. In the present study, X-ray beam diffraction has been utilized to obtain the structural information at different temperatures while cooling. Simultaneously, electrical resistivity (ER) was measured in the phase transformation temperature range. The variation of ER and integral area of the individual diffraction peaks of the different phases as a function of temperature have been compared. A mismatch between the conventional interpretation of ER variation and the results of the XRD data has been clearly identified. - Highlights: ► Phase transformation characterization of Ni–Ti thin film SMA has been carried out. ► Simultaneous monitoring of the XRD and ER with temperature is performed. ► The variation of ER and integral area of the diffraction peaks have been compared. ► A shift of the transformation temperatures obtained by two techniques is discussed.

36 MATERIALS SCIENCE↗