Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Isotopic response with small scintillator based gamma-ray spectrometers

The intrinsic background of a gamma ray spectrometer is significantly reduced by surrounding the scintillator with a second scintillator. This second (external) scintillator surrounds the first scintillator and has an opening of approximately the same diameter as the smaller central scintillator in the forward direction. The second scintillator is selected to have a higher atomic number, and thus has a larger probability for a Compton scattering interaction than within the inner region. Scattering events that are essentially simultaneous in coincidence to the first and second scintillators, from an electronics perspective, are precluded electronically from the data stream. Thus, only gamma-rays that are wholly contained in the smaller central scintillator are used for analytic purposes.

47 OTHER INSTRUMENTATION↗

Development of scintillation materials for medical imaging and other applications

Scintillation materials that produce pulses of visible light in response to the absorption of energetic photons, neutrons, and charged particles, are widely used in various applications that require the detection of radiation. The discovery and development of new scintillators has accelerated in recent years, due in large part to their importance in medical imaging as well as in security and high energy physics applications. Better understanding of fundamental scintillation mechanisms as well as the roles played by defects and impurities have aided the development of new high performance scintillators for both gamma-ray and neutron detection. Although single crystals continue to dominate gamma-ray based imaging techniques, composite materials and transparent optical ceramics potentially offer advantages in terms of both synthesis processes and scintillation performance. A number of promising scintillator candidates have been identified during the last few years, and several are currently being actively developed for commercial production. Purification and control of raw materials and cost effective crystal growth processes can present significant challenges to the development of practical new scintillation materials.

36 MATERIALS SCIENCE↗

Noble gas excimer scintillation following neutron capture in boron thin films

Far-ultraviolet scintillation signals have been measured in heavy noble gases (argon, krypton, xenon) following boron-neutron capture ({sup 10}B(n,α){sup 7}Li) in {sup 10}B thin films. The observed scintillation yields are comparable to the yields from some liquid and solid neutron scintillators. At noble gas pressures of 107 kPa, the number of photons produced per neutron absorbed following irradiation of a 1200 nm thick {sup 10}B film was 14 000 for xenon, 11 000 for krypton, and 6000 for argon. The absolute scintillation yields from the experimental configuration were calculated using data from (1) experimental irradiations, (2) thin-film characterizations, (3) photomultiplier tube calibrations, and (4) photon collection modeling. Both the boron films and the photomultiplier tube were characterized at the National Institute of Standards and Technology. Monte Carlo modeling of the reaction cell provided estimates of the photon collection efficiency and the transport behavior of {sup 10}B(n,α){sup 7}Li reaction products escaping the thin films. Scintillation yields increased with gas pressure due to increased ionization and excitation densities of the gases from the {sup 10}B(n,α){sup 7}Li reaction products, increased frequency of three-body, excimer-forming collisions, and reduced photon emission volumes (i.e., larger solid angle) at higher pressures. Yields decreased for thicker {sup 10}B thin films due to higher average energy loss of the {sup 10}B(n,α){sup 7}Li reaction products escaping the films. The relative standard uncertainties in the measurements were determined to lie between 14% and 16%. The observed scintillation signal demonstrates that noble gas excimer scintillation is promising for use in practical neutron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

On optical properties and scintillation performance of emerging Ga 2 O 3 : Crystal growth, emission mechanisms and doping strategies

As an emerging ultra-wide bandgap compound semiconductor, Ga 2 O 3 has attracted rapidly growing interest due to its unique physical properties for harsh condition applications. Compared to Ga 2 O 3 ’s electrical-characteristic based uses, such as power electronics, photodetectors and solar cells, a much less explored area for Ga 2 O 3 is its promising optical properties and its related scintillation capabilities. Undoped Ga 2 O 3 is a strong scintillator with excellent scintillation characteristics such as fast decay constants and encouraging light yield which is comparable to that of the classic Bi 4 Ge 3 O 12 (BGO) scintillator. The scintillation capability of Ga 2 O 3 can be precisely tuned via a series of approaches including systematic crystal growth control, post-growth annealing, targeted doping, and optimization of operation temperature. Here we summarize exciting progress of Ga 2 O 3 scintillators which have been pursued over the past few years. Our efforts cover a series of growth techniques of Ga 2 O 3 materials as well as discussion of emission mechanisms. Here we dedicate a targeted portion toward the doping strategies to improve the performance of Ga 2 O 3 . A detailed analysis is provided to compare the impact of different dopants. Through these efforts, we hope to provide useful perspectives to help accelerate the development of high performance Ga 2 O 3 scintillators.

36 MATERIALS SCIENCE↗

Scintillator light yield measurements with waveform digitizers

The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only proportional to the amount of scintillation light if the temporal shape of the scintillation pulse is independent of the amount of energy deposited. Finally, this is not the case for scintillation pulses resulting from fast neutron interactions in organic scintillators. Authors measuring proton light yield should therefore report pulse integral values and ensure that the integration length is long enough to capture most of the scintillation light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗

Final Report: Development of High Light Output Plastic Scintillating and Wavelength-Shifting Fibers

Scintillating plastic optical fibers have increasingly been used as radiation detectors in nuclear and high energy physics research since they were first made in 1965. It is proposed to make fibers which are at least a factor of 2 brighter and thereby improve detection efficiency, spatial resolution and energy resolution. When radiation strikes existing plastic scintillator only the singlet excited states rather than the triplet excited states are used to produce scintillation light. This means only 25% of the deposited energy is available to produce scintillation light. Utilization of phosphorescent molecules should therefore drastically improve the light output. This process has been called “triplet harvesting” and has been successfully demonstrated in improving the light output of “Organic Light Emitting Diodes, OLEDs”. The objective of this proposal is to produce a bright scintillating fiber using triplet harvesting and a light output time constant of a few nanoseconds. In addition, an increase in the light containment will be achieved by using a new low refractive index cladding material. In Phase 1, polystyrene plastic material will be used. Organo-metallic phosphorescent and conventional dyes will be dissolved in the plastic to demonstrate both the desired brightness and fast decay time. Photophysical properties will be measured. Scintillating fiber will be made. Commercial benefits of this new material include providing improved detection of rare events such as the HIGGS BOSON at the billion dollar high energy facilities. and monitoring stored radioactive material. The new material will also play an important role in making improved imaging detection facilities for protecting civilians and facilities against CBRN-E threats. In addition, the resolution will be improved for medical brachytherapy. The results of selected organic dyes dissolved in a polystyrene matrix performing as scintillating samples are presented. The proposed organo-metallic phosphorescent dyes were not used due to lengthy synthesis times and cost. Rather, an attempt was made to harvest triplet energy from polystyrene using appropriately wavelength-matched dyes. Samples studied include films and blocks. Fibers were not manufactured as a suitable set of dyes was not determined.

07 ISOTOPE AND RADIATION SOURCES↗

The observation of scintillation in a hydrated inorganic compound: CeCl3 6H2O

We have recently reported the discovery of a new family of rare-earth metal-organic single-crystal scintillators based on Ce3+ as the activator ion. Starting with the CeCl3(CH3OH)4 prototype, this family of scintillators has recently been extended to include complex metal-organic adducts produced by reacting CeCl3 with heavier organics (e.g., isomers of propanol and butanol). Some of these new rare-earth metal-organic materials incorporated waters of hydration in their structures, and the observation of scintillation in these hydrated compounds was an original finding for any solid scintillator. In the present work, we now report what is apparently the initial observation of gamma-ray-excited scintillation in an inorganic hydrated material, namely single-crystal monoclinic CeCl3 6H2O. This observation shows that the mechanisms of the various scintillation energy-transfer processes are not blocked by the presence of waters of hydration in an inorganic material and that the observation of scintillation in other hydrated inorganic compounds is not precluded.

Boatner, Lynn A↗

High-resolution x-ray imaging using a structured scintillator

Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 10: Towards LET detection: A study on the effects of scintillator doping

Purpose: In radiotherapy, the amount of radiation delivered is determined by optimizing the amount of absorbed dose to the tumor. Dose does not always correlate well with the actual biological effects of radiation. This work seeks to validate the LET-dependence of doped plastic scintillators for use in a radiation beam quality (LET) detector. Methods: The LET spectrum ([Φ]) can be resolved knowing the measured signals of uniquely LET-dependent detectors, [S], and the response of each LET-dependent detector to specific LETs ([R]), through the relation [Φ]=[S][R]{sup −1}. Plastic scintillator response is intrinsically LET dependent and can be varied via doping. Initial prototype consists of plastic scintillator and glass taper coupled to an optical fiber; components are housed in black acrylic, reducing effect of ambient light. In order to determine [R], the light response matrix, GEANT4.10.1 Monte Carlo (MC) was used. To validate MC, measurements were done using high energy electrons (9,12,15MeV) and orthovoltage x-rays (100,250kV); scintillator signal was normalized to dose measured simultaneously. Results: Stopping power was varied by changing particle type/energy; measurements indicated that as stopping power increased from 1.9 to 6.6MeV/cm, detector response increased by 263% (+/−29.2%) for 5%Pb-doped scintillator (155% in MC); 52% (+/−7.8%) increase observed when undoped scintillator was used (49% in MC). 5%Pb-doped discrepancy (100kV x-rays) is being investigated. Conclusions: This work validates that doping effects LET/energy response of scintillators; an effect that can be utilized for construction of an LET detector.

60 APPLIED LIFE SCIENCES↗